Fibre Network Solutions Europe - Passcomm · 2018. 10. 4. · Wrapping Tube Water absorbent yarn...

Post on 22-Mar-2021

2 views 0 download

Transcript of Fibre Network Solutions Europe - Passcomm · 2018. 10. 4. · Wrapping Tube Water absorbent yarn...

Fibre Network Solutions EuropeWTC TCO analysis

Ultra-High Density Fibre Cables

Largest 3,456 fibres

Smallest 144 fibres

Todays presentation focus on our 432 fibre cable designs – considered an ‘entry-level’

WTC (wrapping tube cable) comparison analysis

Scope:

To review the Total Cost of Ownership (TCO) benefits of Fujikura’s ultra-high-density

Wrapping Tube Cables (WTC) and innovative Spider Web Ribbon (SWR) fibre

technology compared to traditional Loose Tube designs.

SPIDER WEB RIBBON (SWR)

PROVEN AND ESTABLISHED TECHNOLOGY

Innovative 12 Fibre Ribbon

Jacket (PE)Ripcords

Strength Member (Glass FRP)

Bundle Unit by Bunching Tape

Spider Web Ribbon

with Ringmarking

Water Blocking Tape

Spider web ribbon

Wrapping Tube

Water absorbent yarn

Wrapping Tube Cable Construction (WTC)

PROVEN AND ESTABLISHED TECHNOLOGY

Cable construction is completely dry

reducing cable preparation timeMass fusion splicing of ribbon fibres

Cable Installation

70 % reduction in time 70 % reduction in time

Ribbon Splicing

Increased packing density

432 fibre WTC have smaller diameters

compared to traditional Loose Tube Duct

designs (14.8mm versus >18mm)

Space Efficiency

Alternative Industry Designs

Cable Strike

• Significantly reduced outage time

• Urgent circuits restored quickly

Typical restoration time in hours:

432 Fibre WTC/SWR 4-5

432 Fibre LT Duct 16-20

Significant Operational Savings

ANALYSIS - General Assumptions

• Cable sections typically 2km between joints

• Industry standard joint at both ends

• Installed within sub-duct 20mm (internal diameter)

To demonstrate the benefits of WTC/SWR, we For illustration purposes we have outlined a number of scenarios;

1. 432F WTC to 432F WTC

2. 432F Loose Tube to 432F Loose Tube (conventional design)

3. 432F WTC to 432F Loose Tube x3 144F LT using ribbon splicing

Fujikura 432F WTC to 432F WTC using SWR

FJK 432f WTCFJK 432f WTC FJK 432f WTC

WTC Cable Preparation per joint 1 hour

SWR Splicing (432F = 36 Ribbons) 3 hours

TOTAL TIME (2 joints) 8 HOURS

432F to 432F Loose Tube cable (single fibres)

1 x 432 LT cable

LT Cable Preparation per joint 3 hours

Splicing – single fibre (432) 14 hours

TOTAL TIME (2 joints) 34 HOURS

Customer feedback suggested 41 HOURS

1 x 432 LT cable 1 x 432 LT cable

432F WTC to Multiple LT designs (Ribbon to single fibres)

FJK 432f WTC3 x 144f LT cable

1 x 432f LT cable

WTC Cable Preparation 0.5 hours

LT Cable Preparations 3 hours

Ribbon Preparation 1.5 hours

SWR Splicing 3 hours

TOTAL TIME (2 joints) 16 HOURS

Ribbon Splicing to Individual Fibres

9.7 14.2

18.7 23.3

27.8

54.9

0

10

20

30

40

50

60

288 432 576 720 864 1728

Sp

lici

ng

Tim

e (

Hrs

.)

Fiber Count / Cable

Single fiber splicing

■Single Fiber Loose Tube cable ■SWR/WTC

Ribbon fiber splicing

2.1 2.8 3.5 4.1 4.8 9.0

Estimated Splicing Time Comparison

Dramatic splicing time reduction

Splice Loss

• Total Splices: 432 SWR’s (5,184 individual fibres)

• Environment: Field Conditions

• Average splice loss <0.02dB @ 1550nm

• Average link loss <0.19dB/km @ 1550nm

• Rework <5% fibre (total ribbons)

• No multiple reworks

• Predicted 70R splice loss results consistent with OTDR bi-directional measurements

Fibre management of WTC/SWR in closure

Compatible with industry standard joint closures

WTC Fibre ODF

ODF is designed for use in a Building Entrance Solution for high fibre count Wrapping Tube Cables® (WTC), providing a demarcation point between OSP and ISP cables.

Significant operation benefits

• Small diameter and light weight

• Clean dry cable design (no water blocking gel)

• Manufactured in long lengths for versatility in deployment

• Suitable for mass fusion splicing

Significant cost savings

• 75% overall installation time saving (432F WTC-WTC)

• 35% improved duct efficiency (432F WTC versus 432F LT Duct)

• Substantial operational savings

• Deferred costs (significant)

Benefits Summary

44 (0)20 8240 2000www.Fujikura.co.uk