Post on 15-Aug-2020
www.behringersystems.com Phone: (973)948-0226 sales@behringersystems.com
Applications• Filtering fluids while transferring to reservoirs
• Conditioning already in-service fluids to prolong fluid life
• Removing water contamination (free water) in systems
• Supplemental filtration in systems where additional filtration may be required at times
• Servicing fleet equipment
Features• Rugged heavy-duty frame is designed for rigorous use. High-quality powder coating protects steel
frame from weathering.
• Oversized solid rubber (never flat) tires make transporting easy and efficient. Heavy-duty wheels have
greasable bearings.
• Industrial-grade gear pump is rugged and durable. Flow rate is 10 GPM.
• Single phase motor, 115V/230V, 8.4/4.2 amps.
• Heavy duty On/Off switch with 8-foot electrical cord.
• Rated for hydraulic and lube oils with viscosities up to 220 cSt (1000 SSU).
• Durable 32” long zinc-plated steel wands are strong and resist breaking compared to competitor
brands.
• Clear flexible kink-resistant hoses help protect pump. 8' Hoses installed using safe and strong 2-Ear
clamps are standard.
• 2-stage filtration (in series) gives longer filter element life and time between service intervals.
• Visual gauges tell you when each filter needs changing. Separate gauges for each filter maximizes
each filter's life.
• Pump bypass loop prevents system damage due to over-pressurization.
**1 Viscosity range is recommended based on the suction hoses and pump capacity. As fluids heat or
cool, their viscosity will change. Please ensure that the fluid viscosity is in the working range of the unit.
Fluid must be checked to determine that viscosity is not to exceed 220 cSt. For fluids with higher viscos-
ity, please consult Behringer for application assistance.
FC Series Portable Filter Carts
For Hydraulic and Lube Oils
Performance:Temperature: 150°F
Flows: 10 gpmViscosity Range*1: Up to 220 cSt (1000 SSU)
Flow Rate: 10 gpm (37.5 lpm)
www.behringersystems.com Phone: (973)948-0226 sales@behringersystems.com
Features and Benefits:
www.behringersystems.com Phone: (973)948-0226 sales@behringersystems.com
Recommended Operating ConditionsType: FC Series Filter Cart
Temperature Range*2: 32°F to 150°F (0°C to 65°C)
Pump Bypass: 87 psid (6 bar)
Materials of ConstructionCart: Powder coated welded steel frame
Wands: 32” long electro-zinc plated steel
Hoses: Clear flexible kink-resistant suction hoses
Wheels: Solid rubber with greasable bearings
Filtration Unit SpecificationsType: Dual (inline) Behringer spin-on
Filter Heads: Cast aluminum
Gauges: Tri-color pressure gauges
Filter Bypass: 25 psid (1.7 bar)
Filter Elements: High-efficiency absolute rated
or water-removal spin-on style
elements
Filtration Ratings: 1, 3, 6, 12, 25μm Bx =200
(Bx[c] =1000)
10μm nominal + water-removal
Electric Motor SpecificationsMotor Voltage: 115/230V single phase, 8.4/4.2 amps, 60Hz
50Hz Option: 115/230V single phase, 8.4/4.2 amps, 50Hz
Unit Weight
Approx. Weight: 140 lbs (63.5 kgs)
*2 Max operating temperature is dependant upon the standard nitrile (Buna) seals. Other seal materials
are available for different operating temperatures and fluid types. Please consult Behringer for proper ap-
plication of seal materials. Please also note that temperature will affect the viscosity of the fluid.
Sizing and Duration
In order to properly condition fluid in your reservoir, we
recommend turning the reservoir over approx. 7 times to
ensure that all the fluid has been passed through the filter
once.1 To achieve this, you can use the following formula
to determine how long to run the filter cart.
Flow rate (10 GPM) _________________ = Service Time (Minutes)
Reservoir Size x 7
For a 100 gallon reservoir, the formula would be:
100 gallons x 7_____________ = 70 Minutes
10 GPM
Using this formula achieves single-pass filtration. If you
want to condition fluid further, you can multiply the
service time by the number of passes you would like to
achieve. For example, for 2-pass filtration you would
multiply 70 minutes x 2 and that yields a 140 minute run
time for 2-pass filtration on a 100 gallon reservoir. Notes:1. 7- time reservoir turnover is as recommended by Noria Corporation
www.behringersystems.com Phone: (973)948-0226 sales@behringersystems.com
__ FC __ __ __ - __ / __ - __ Table 1 Table 2 Table 3 Table 4 Table 5 Table 6Table 5
BS0128 __-__ 38 __ Table 3 Table 5
Replacement Elements
Table 6