Factsheet CucorAl - Aluminum Cladded Copper Wire for Power ... · Aluminum Cladded Copper Wire for...

Post on 19-Apr-2020

21 views 1 download

Transcript of Factsheet CucorAl - Aluminum Cladded Copper Wire for Power ... · Aluminum Cladded Copper Wire for...

Recommended Technical Data of

Diameter Microns (µm) 200 300 350 400 450 500

Mils 8 12 14 16 18 20

Elongation (%) > 15 > 15 > 15 > 15 > 15 > 15

Breaking Load (cN) 400 1000 1400 2000 2600 3200

- 700 - 1400 - 2000 - 2600 - 3300 - 4000

For other diameters, please contact Heraeus Bonding Wires sales representative.

Aluminum Cladded Copper Wire for Power Application

The CucorAl bonding wire is a composite wire type with a coppercore and aluminum coating. Thematerial mix of aluminum and copper provides excellent electricaland mechanical properties.This is reflected by the long-termbehavior during both passive tem-perature cycling tests and especiallyactive power cycling tests – in comparison to pure Al material.The copper proportion of this thickwire is between 60 – 70 percent byvolume. The provided diametersrange from 200 µm until 500 µm.

This wire type can be applied onboth, diodes and on IGBTs. The goodbondability of the wire is achievedby the softness of the aluminumcoating. At the same time, the copper core provides excellent elec-trical and thermal properties.

Furthermore, the Al/Cu structureenables reliable bonding windowswithout changing the chip metal-lization. Additionally, the CucorAl bonding wire has been designed tobe used with conventional bondingequipment.

BenefitsSoftness and good bondingcharacteristicsIncreased reliability compared to standard aluminum materialCompatibility with standard bonding and standard chip technologySuperior electrical and thermal capabilitiesOutstanding power cycling performance

Power Cycling Lifetime as a Function of �Tj

1E+8

1E+7

1E+6

1E+5

1E+440 60 80 100 120 140 160

Cycles of Failure

x 3.7

CucorAl

40 C...150 C

40 C...175 C

80 C...150 C Al a.r. = 0.33

x 7-8

x 22

Cross section of am 300 µm Al/Cu wire bond

60,00

50,00

40,00

30,00

20,00

10,00

0,00200 300 400 500

Diameter [µm]

Fuse

Cur

rent

[A]

CucorAlStandard Al Wire

Loop Lenght: 20 mmRamp: 0.2 A/s

Fatigue Behavior in Micromechanical Cycling Test

Publication on PCIM 2012, R. Schmidt et al.

Bonding Window

Bond Power*Bond Force (g) Bond Time (ms)*Bond Force (g)

120

105

90

75

60

100

80

60

40

400 500 600 700 800

Bond Time (ms)*Bond Power

60 75 90 105 120

100

80

60

40

400 500 600 700 800

Shearforce (cN)< 890

890 – 972972 – 10541054 – 11361136 – 12181218 – 13001300 – 13821382 – 14641464 – 15461546 – 16281628 – 1710

> 1710

1

0,1

1E+3

2,5

x 1E

+3

5 E+

3

1E+4

2,5

E+4

5 E+

4

7,5

E+4

E+5

No. of Cycles [N]

Manson-Coffin Relation

Standard Al Wire 300 µmCucorAl Wire 300 µm

Plas

tic S

train

[arb

itrar

y uni

ts]

Manson-Coffin Relation1

Plas

tic S

train

[arb

itrar

y uni

ts]

CucorAl Wire 300 µmStandard Al Wire 300 µm

1E+4

5 E+

3

2,5

x 1E

+3

1E+3

0,1

Plas

tic S

train

[arb

itrar

y uni

ts]

No. of Cycles [N]

E+5

7,5

E+4

5 E+

4

2,5

E+4

Fusing Current

The

data

giv

en h

ere

is v

alid

. We

rese

rve

the

right

to m

ake

tech

nica

l alte

ratio

ns.

Heraeus ElectronicsHeraeus Deutschland GmbH & Co. KG Heraeusstraße 12-1463450 Hanau, Germanywww.heraeus-electronics.com

AmericasPhone +1 610 825 6050 electronics.americas@heraeus.com

Asia PacificPhone +65 6571 7677 electronics.apac@heraeus.com

ChinaPhone +86 21 3357 5457 electronics.china@heraeus.com

Europe, Middle East and Africa Phone +49 6181 35 3069

+49 6181 35 3627 electronics.emea@heraeus.com

The descriptions and engineering data shown here have been compiled by Heraeus using commonly-accepted procedures, in conjunction with modern testing equipment, and have been compiled as according to the latest factual knowledge in our possession. The information was up-to date on the date this document was printed (latest versions can always be supplied upon request). Although the data is considered accurate, we cannot guarantee accuracy, the results obtained from its use, or any patent infringement resulting from its use (unless this is contractually and explicitly agreed in writing, in advance). The data is supplied on the condition that the user shall conduct tests to determine materials suitability for particular application.

N, L

ayou

t:dat

agra

phis

,Wie

sbad

en-H

ET16

007-05

16-1