Expanding a case

Post on 24-Mar-2016

214 views 0 download

Tags:

description

This 83 year old male received an implant in first molar site so he would have posterior support once two hopeless teeth would be removed. Well that time has come. 21 and 22 were removed. After initial healing two Nobel Biocare implants were placed in a submerged protocol.

Transcript of Expanding a case

Copyright © 2012 Idondivi, Inc. All rights reserved.

Categories ; Anterior, Posterior, Grafting, Multiple implants,

Nobel Biocare

2 Copyright © 2012 Idondivi, Inc. All rights reserved

Failing teeth with advanced boneloss

3 Copyright © 2012 Idondivi, Inc. All rights reserved

Extraction after creating posterior implant support

4 Copyright © 2012 Idondivi, Inc. All rights reserved

Healing at 3 months , note less density at cuspid site

5 Copyright © 2012 Idondivi, Inc. All rights reserved

Over extended impression acquiring a large part of the edentulous ridge

6 Copyright © 2012 Idondivi, Inc. All rights reserved

BLP locks in the Bucco-lingual position and the shoulder of the implant,a 3.5 mm

implant will be selected

7 Copyright © 2012 Idondivi, Inc. All rights reserved

BLP glued in at premolar site, a 4.3 mm implant will be selected

8 Copyright © 2012 Idondivi, Inc. All rights reserved

The wings are bonded to the vacuform carrier

9 Copyright © 2012 Idondivi, Inc. All rights reserved

The clinical situation, note how the molar implant does create posterior support,

while the anterior situation is under treatment

10 Copyright © 2012 Idondivi, Inc. All rights reserved

The buccal has been cut short for easy flap management

11 Copyright © 2012 Idondivi, Inc. All rights reserved

Drills set at 8.5 mm ( 13 – 3 – 1.5)

12 Copyright © 2012 Idondivi, Inc. All rights reserved

Radiograph shows that an additional 1.5 mm, for 10 mm implants is OK

13 Copyright © 2012 Idondivi, Inc. All rights reserved

Preparation now made for 10 mm implant, note green 1.5 mm flexistop was

removed

14 Copyright © 2012 Idondivi, Inc. All rights reserved

Last drill with additional 3 mm flexistop for stepped back preparation for tapered

implant

15 Copyright © 2012 Idondivi, Inc. All rights reserved

Premolar site is tapped with guided tap from Nobel Biocare

16 Copyright © 2012 Idondivi, Inc. All rights reserved

Bone particles are collected

17 Copyright © 2012 Idondivi, Inc. All rights reserved

Incomplete healing at cuspid site, osteotomies are completed

18 Copyright © 2012 Idondivi, Inc. All rights reserved

Implants are placed

19 Copyright © 2012 Idondivi, Inc. All rights reserved

Final torque, with good initial stability, 3.5 x 10 and 4.3 x 10 Nobel Active

20 Copyright © 2012 Idondivi, Inc. All rights reserved

Buccal defect, although body of implant is within bone contour.

21 Copyright © 2012 Idondivi, Inc. All rights reserved

Bone collected

22 Copyright © 2012 Idondivi, Inc. All rights reserved

Defect is grafted with collected bone particles

23 Copyright © 2012 Idondivi, Inc. All rights reserved

Submerged healing as patient is wearing a stay plate

24 Copyright © 2012 Idondivi, Inc. All rights reserved

Implants placed as planned, submerged healing.