ENGINES. VEHICLE / HEAVY EQUIPMENT SAFETY INSPECTION CHECKLIST OF 296.

Post on 01-Jan-2016

224 views 5 download

Tags:

Transcript of ENGINES. VEHICLE / HEAVY EQUIPMENT SAFETY INSPECTION CHECKLIST OF 296.

ENGINES

VEHICLE /HEAVY

EQUIPMENTSAFETY

INSPECTIONCHECKLIST

OF 296

ADDITIONAL FORMS

ADDITIONAL FORMS

TYPE 3 4 5 6 7

PUMP CAP.

GPM 150 50 50 50 10

PSI 250 100 100 100 100

TANK CAP

MIN. GAL. 500 750 400 150 50

MAX. GAL. 1500 1500 749 399 200

1” HOSE

¾” INSIDE DIA. 100 FT 100 FT 100 FT 100 FT

1 ½” HOSE 1000 FT 300 FT 300 FT 300 FT

1 “ HOSE 500 FT 300 FT 300 FT 300 FT 200 FT

¾” HOSE 300 FT 300 FT 300 FT 300 FT

PUMP & ROLL YES YES YES YES

FOAM PROP. SYS. YES YES YES YES

MAX. GVWR (lbs) 26,000 19,500

PERSONNEL 3 3 3 3 2

MINIMUM STDS FOR ENGINES

EQUIPMENT REQUIREMENTS

Shall not exceed manufactures GVWR.

Shall not exceed manufactures GAWR.

Vehicle weighed:Fully loadedFull of fuel including any extra fuel cansFull of waterAdd 250 lbs per person

Four wheel drive:Type 6 – RequiredType 3,4,&5 - Optional

Tires:Load ratingAll season or mud & snow treadMinimum tread depthsSpare tire

BACKUP ALARM

RADIO’S

www.fireradios.net

VEHICLE MARKINGS

COMPANYNAME

#33

CHAINSAW

CHAINSAW INSPECTION FORM

HOSE REEL

REELTEX HOSE

BAFFLING

TANK SECUREMENT

Foam Capabilities:

Required on all engines

3 Types

Manually Regulated Proportioning SystemAutomatic Regulating Proportioning SystemCompressed air foam system (CAFS)

Minimum 5 gallons foam

MANUALLY REGULATED PROPORTIONING SYSTEM

A proportioning system that requires manual adjustment to maintain the proportioning ratio when there is a change of flow or pressure through the foam proportioner.

Typical manually regulated foam systems include:Suction side proportionerIn-line eductorAround-the- Pump Proportioner Direct injection manually regulated proportioners

Examples:Blizzard WizardScotty Foam InductorFoam Flo

AROUND THE PUMP

AUTOMATIC REGULATING PROPORTIONING SYSTEM

A proportioning system that automatically adjusts foam the flow of foam concentrate into the water stream to maintain the desired proportioning ratio.

These automatic adjustments are made based on changes in water flow or conductivity.

Examples:Foam Pro 1601/2001Robwen 500Darley Fast-foam SystemAqui 1.5/2.5 Foam System

AUTOMATIC REGULATINGPROPORTIONING SYSTEM

COMPRESSED AIR FOAM SYSTEM

COMPRESSED AIR FOAM SYSTEM

PUMPS

Discharge Press.Gauge 1 ½” Discharge

Drafting

PUMPS

Pressure ReliefValve

Positive Displacement

Pump

PUMP TEST KIT

NH NPSHNATIONAL HOSE NATIONAL PIPE STRAIGHT HOSE

GARDEN HOSE

PERSONAL PROTECTIVE EQUIPMENT

Fire shelters

Nomex Shirt & Pants

Hardhat

Gloves

Boots

OTHER PERSONAL EQUIPMENTREQUIRED

Eye Protection

Hearing Protection

Headlamp

Line Gear