EDX-10A SeriesCompact Recording System
Compact, lightweight, with a simple configuration, all channels simultaneous 20kHz high-speed sampling (for 4 channels)
A unit controls a measuring unit and performs the control with PC via USB interface.●When a single unit,measurement channel is 4.●With 4 measuring units, measurements of 16 channels possible (Use of 2 or more measuring units requires an
optional AC adapter. )
SpecificationsInterface : USB2.0 compliant Connector configuration: USB standard B receptacleNumber of Installed Measuring Units : Max. 4 (16CH)Sampling Frequency : 1Hz~ 20kHz (1 to 4CH) 1Hz~10kHz : 1~8CH 1Hz~5kHz : 1~16CH 1/2/5 series All channels simultaneous samplingOperating Temperature Range : 0 to +40°CPower Supply : DC5V If 1 measuring unit, power supplied by PC USB port For 2 or more units, power is supplied by AC adapterCurrent Consumption : 140mA or less (DC5V)Weight : Approx. 170gDimensions : 84.0mm (W)×26.6mm (H) ×84.0mm (D) (not including protrusions)EMC Directive : EN61326-1(Class A)RoHS Directive : EN50581
■Control unit EDX-10A
The EDX-10A series compact recording system is measuring instruments that measure simply by being connected to a PC using the USB interface. There are three types of measuring unit; the EDX-11A that measure with strain gage type transducers, pressure, displacement, etc. The EDX-12A that measure voltage, and the EDX-13A that measure temperature with a thermocouple. As single unit can be powered by USB interface,a separate power supply is unnecessary.With stacked connection,a synchronization cable is unnecessary,it realized wiring-saving.A single unit enables 4 channel measurement,can be expanded up to 16 channels, which suitable for small-scale measurement.
●On a single unit,power supply from USB on PC is possible
●When a single unit,measurement channel is 4. And with 4 units, measurement of 16 channels is possible (Use of 2 or more measuring units requires an optional AC adapter.)
●With stacked connection, a synchronization cable is unnecessary,it realized wiring-saving.
●When a single unit,max sampling frequency at 4ch is 20kHz.
●Compact, lightweight●Simple connection using USB interface●The standard accessory,DCS-100A dynamic
data acquisition software,makes it easier data monitoring or acquisition.
●Data will be recorded as KS2, which is Kyowa standard file format.The optional data analysis software DAS-200A can read them.
●Sensors can be easily connected with one-touch input cable or connectors.
Dynamic data acquisition software DCS-100A (CD-ROM), USB cable N-38 (1 m), Ground wire P-72 (5 m),Rubber foot (8 pieces/sheet), Manual (Japanese/English in the CD-ROM)
AC adapter UN310-0515
Standard Accessories
Optional Accessories
Strain Gages
Encapsulated Strain Gages
Load Cells
Pressure Transducers
Acceleration Transducers
Torque Transducers
Displacement Transducers
thermocouple
Voltage
3-62
3-62
DATA RECORDERS/AN
ALYZERS
Sensor to recommend
A unit using direct current bridge excitation method to measure strain. ●When a single unit, measurement channel is 4.●By connecting to control unit, measurement is
possible
■Strain measuring unit EDX-11A
A unit for measuring voltage.
The thermocouple measuring unit is designed to measure temperature.
●With 1 measuring unit, measurement of 4 channels is possible●By connecting to control unit, measurement is
possible
Specifications
Specifications
■Voltage measuring unit EDX-12A
Input adapter UI-51A
Terminal box 1piece, Screwdriver 1piece
BNC input cable U-125(30 cm)Bridge box coupling cable U-126 (50 cm)One-touch type input adapter UI-52AInput Connector Set EDX10-DSUB
Standard Accessories
Standard Accessories
Optional Accessories
Specifications
Strain input cable U-124 (30 cm)
Bridge box coupling cable U-126 (50 cm)Input adapter UI-51AOne-touch type input adapter UI-52ABridge adapter for quarter bridge system UI-53A-120/350Bridge adapter for quarter bridge system UI-54A-120/350One-touch type input adapter UI-55AInput Connector Set EDX10-DSUB
Standard Accessories
Optional Accessories
■Thermocouple measuring unit EDX-13A
*The measurement accuracy does not reflect the accuracy of the internal reference contact compensator and thermocouple.
−200.0~ +1370.0°C
−200.0~ +400.0°C
−200.0~ +1200.0°C
−200.0~ +1300.0°C
0.1°C
−200.0~−100.0°C or less−100.0~+1370.0°C
−200.0~−100.0°C or less−100.0~+400.0°C
−200.0~−100.0°C or less−100.0~+1200.0°C
−200.0~−100.0°C or less−100.0~+1300.0°C
±(0.2%rdg +0.6°C)±(0.1%rdg +0.4°C)
±1.0°C 〔Input terminal temperature at equilibrium〕 〔Ambient temperature range: 25±10°C〕*Mount the EDX-13A on the bottom when using it with measuring units other than the EDX-13A.±2.0°C 〔Input terminal temperature in equilibrium〕
For temperatures other than those inthe ambient temperature and operatingtemperature ranges described above
±(0.2%rdg +0.6°C)±(0.1%rdg +0.4°C)
±(0.2%rdg +0.6°C)±(0.1%rdg +0.4°C)
±(0.2%rdg +0.6°C)±(0.1%rdg +0.4°C)
K
T
J
N
Type Measurement Range Resolution Measurement Accuracy Accuracy of internal reference contact compensator
Object to Be Measured : VoltageNo. of Input Channels : 4 (single end)Measurement Range : 10V, 50V (2 ranges)Range Accuracy : Each range within ±0.3%FSNonlinearity : Within ±0.1%FSAD Resolution : 24 bitFrequency Response Range : DC to 2kHzLow Pass Filter : Cutoff frequency: Low (100Hz), High (2kHz) 2nd Order ButterworthOperating Temperature Range : 0 to +40°CInput Connector : D-sub 37 pin connectorPower Supply : DC5V supplied by control unitCurrent Consumption : 110mA or less (DC5V)Weight : Approx. 150gDimensions : 84.0mm (W)×26.6mm (H) ×84.0mm (D) (not including protrusions)EMC Directive : EN61326-1(Class A)RoHS Directive : EN50581
Object to Be Measured : ThermocoupleNo. of Input Channels : 4 Applicable sensors : K, T, J, N (Resistance of thermocouple: 1kΩ or less) (See the table below for details about the temperature measurement range, etc.)Check function : Burnout check.AD Resolution : 24 bitsSampling System : ScanningInside Samping frequency : Approx. 0.5Hz, Approx. 2.0HzInput Connector : Threaded connection type terminal boxCurrent Consumption : 120mA or less (DC5V)Weight : Approx. 130gDimensions : 84.0mm (W)×26.6mm (H) ×84.0mm (D) (not including protrusions)EMC Directive : EN61326-1(Class A)RoHS Directive : EN50581
Object to Be Measured : Strain gage transducer, strain gage (bridge box used)No. of Input Channels : 4Measurement Range : 10000, 50000μm/m (2 range)Applicable Bridge Resistance : 120Ω~1kΩBridge Excitation : DC2VGage Factor : 2.00 fixedRange Accuracy : Each range within ±0.3%FSNonlinearity : Within ±0.1%FSAD Resolution : 24 bitFrequency Response Range : DC to 2kHzLow Pass Filter : Cutoff frequency: Low (100Hz), High (2kHz) 2nd Order ButterworthOperating Temperature Range : 0 to +40°CInput Connector : D-sub 37 pin connectorPower Supply : DC5V supplied by control unitCurrent Consumption : 180mA or less (120Ω load with all channels connected, at power source DC5V)Weight : Approx. 150gDimensions : 84.0mm (W)×26.6mm (H) ×84.0mm (D) (not including protrusions)EMC Directive : EN61326-1(Class A)RoHS Directive : EN50581
Strain Gages
Encapsulated Strain Gages
Load Cells
Pressure Transducers
Acceleration Transducers
Torque Transducers
Displacement Transducers
thermocouple
Voltage
3-63
3-63
DATA RECORDERS/AN
ALYZERS
Sensor to recommend
●DCS-100A software specifications (standard accessory)・Display of measurement data as numerical values or as various
graphs is possible ・Control of Kyowa measurement devices possible ・Direct saving of measurement data on PC hard disk possible・Data processing and analysis software (optional) can be started
from the tool bar
Number of Connected Measuring Units : Max. 4 (Max. 16CH)Interface : USBCollection : Measurement data is saved on the PC hard disk (Saved as KS2 file)Channel Conditions : Measurement ON/OFF, mode, range, low pass filter, correction coefficient, offset, unit, CH name, measurement range, number of digits after decimal point, rated capacity, rated output, maximum check value, minimum check value, (selection of arbitrary display items possible)Sampling Frequency : 1 to 20kHz (1/2/5 series) *Limitations exist depending on measurement channelMeasurement Mode : Manual, manual (specified amount of collection data), interval, analog triggerManual Measurement : Measurement is made from a press of the REC button to a press of the STOP button or to completion of recording to the preset number of measurements. Interval Measurement : Measurement is made automatically at preset intervals from the preset starting time.Analog Trigger Measurement : Start/stop recordig based upon specified trigger conditions (Trigger level value fixed) End trigger : Settings possible Delay : For both start/stop, maximum 262,144 data items/1CH Delay differs depending on the number of measurement channels Trigger channel : Arbitrary 1 channel Trigger level : Set depending on physical quantity Trigger slope : Start-up/shutdownStatic Measurement : Each time collection starts, measurement data processed as a moving average appended to the CSV format file and saved. *Available when the measurement mode is manual or intervalRepeat Collection : for long-duration calculation, this saves to KS2 file at specified quantities of data (specified periods) *Available when the measurement mode is manual (specified amount of collection data)Environment Settings Hardware configuration settings : Connected units, configuration of equipment name Configuration of device names connected to EDX-10A possible Reading of hardware configuration from EDX-10A possible Data file automatic conversion : At the end of measurement, automatically converts the file (CSV format, XLS format, XLSX format, RPCⅢ format). Arbitrary unit settings : The user can register 3 types of unit types from those that can be setMonitor Screen Y-Time graph : The X axis is the time axis, and the Y axis is the measured physical display, and display of a maximum 16 channels is possible Display of 1 to 4 graphs on 1 screen is possible Y-Time (DIV) graph : The X axis is the time axis, and the Y axis is the physical quantity, and display of a maximum 16 channels is possible Different to the time series graph above, the displayed channels 0 point position can be changed to an arbitrary point on the Y axis parting line. X-Y graph : Graph display for both the X/Y axis using arbitrary 8 channel combinations is possible Bar graph : Display of a maximum of 32 channels on 1 graph is possible. Display of 1 to 4 graphs on 1 screen possible. Peak hold ON/OFF (numerical value display possible) Bar meter : Display of an arbitrary channel horizontally or vertically is possible Circular meter : Display of an arbitrary channel with the Circular meter is possible
Numerical value display : Arbitrary 1 channel display, arbitrary 16 channel display (Maximum and minimum value displays possible only in arbitrary 1CH display) Screen display colors : Arbitrary change of graph units possible Title, label : Arbitrary setting of title and X/Y axis labels possible Simultaneous display items : numerical value display: 32, various graphs: 32 With numerical value display and graph display, display of up to 64 items possible (including screen/numerical value display items displayed on the data playback display) (*) Display of the maximum numbers may not be possible, depending on the PC CPU speed and memory capacity. Data File Save format : Saved in the Kyowa standard file format (indicated below as KS2). Save destination : On PC hard diskData Reproduction Y-Time graph : The X axis is the time axis, and the Y axis is the measured physical display, and display of a maximum 16 channels is possible. Display of 1 to 4 graphs on 1 screen possible Y-Time (DIV) graph : The X axis is the time axis, and the Y axis is the physical quantity, and display of a maximum 16 channels is possible Different to the time series graph above, the displayed channels 0 point position can be changed to an arbitrary point on the Y axis parting line. X-Y graph : Graph display for both the X/Y axis using arbitrary 8 channel combinations is possible Numerical value display : List display Screen display colors : Arbitrary change of graph units possible Title, label : Arbitrary setting of title and X/Y axis labels possible Cursor display : Cursor location engineering value numerical value display Simultaneous display items : numerical value display: 32, various graphs: 32 With numerical value display and graph display, display of up to 64 items possible (including graph display displayed on monitor screen/numerical value display items) (*) Display of the maximum numbers may not be possible, depending on the PC CPU speed and memory capacity. Display possible data file size : Data file size that can be displayed at one time in the graph/numerical value display is max. 10MB. If 10Mbytes is exceeded, then by setting the display range, display of an arbitrary range of 10MB of data is possible. File conversion : Arbitrary range or channel file clipping, CSV file conversion, Excel format conversion, and RPCⅢ format conversion are possibleOperating Environment : OS : Windows XP, Windows Vista, Windows 7 Japanese/English, 32/64 bit support (If OS is Windows XP, only 32 bit is supported) *If 64 bit OS, operate in WOW64 Operates using WOW64 (Windows 32-bit On Windows 64-bit) CPU : Pentium4 2GHz or better (If OS is Windows XP, PentiumⅢ1GHz equivalent or better) Memory : 2GB or more (If OS is Windows XP, 1GB or more) Display : Resolution: 1024×768 dots or more HDD : At installation, 20MB+measurement data storage space
Strain Gages
Encapsulated Strain Gages
Load Cells
Pressure Transducers
Acceleration Transducers
Torque Transducers
Displacement Transducers
thermocouple
Voltage
3-64
3-64
DATA RECORDERS/AN
ALYZERS
Sensor to recommend
■Dimensions
EDX-10A
8426
.6
84
5980
21.6
EDX-11A
59
8426
.6
84
80
21.6
3.5
EDX-12A EDX-13A
59
8426
.6
84
80
21.6
3.5
598426
.630
.1
84
21.6
(93)
(Terminal box attachment)
■(EDX-11A for optional) Input adaptor UI-51A
■(EDX-11A/12A for optional) One-touch type input adaptor UI-52A
●For strain gage tranceducers (bared at the tip). Mounted on a strain measuring unit.●For voltage input(bared signal line at the tip). Mounted on a strain measuring unit.
●For strain gage tranceducers (bared at the tip). Mounted on a strain measuring unit.
■(EDX-11A for optional) Bridge adapter for quarter bridge system UI-53A-120(For 120Ω) UI-53A-350(For 350Ω)
●Mounted on a strain measuring unit.●Quarter bridge system, 2-/3-wire strain gage is connected directly to the main body.
EDX-10A SeriesRecommended
products for combination
→ 4-9
Data Analysis Software DAS-200A
■(EDX-11A for optional) Bridge adapter for quarter bridge system UI-54A-120(For 120Ω) UI-54A-350(For 350Ω)
■(EDX-11A for optional) One-touch type input adapter UI-55A
*Applicable Standard EMC Directive EN61326-1(Class A) RoHS Directive EN50581
●Marking correspondence*●Mounted on a strain measuring unit.●Quarter bridge system, 2-/3-wire
strain gage is connected directly to the main body.
●Mounted on a strain measuring unit.●Strain gage and strain gage transducer of full
bridge system connected to body directly.
→ 3-88
Bridge box DB-120V-4E/ETDB-350V-4E/ET
Strain Gages
Encapsulated Strain Gages
Load Cells
Pressure Transducers
Acceleration Transducers
Torque Transducers
Displacement Transducers
thermocouple
Voltage