Post on 14-Apr-2015
description
SYSTEMS
www.pbasystems.com.sg
I R O N L E S S L I N E A R M O T O RDX B SERIES
H I G H E S T F O R C Epoint-to-point motion systems
PAGE 02
PBA Systems is an ISO certified company that designs and manufactures motion control products, including linear motor modules, voice coil modules, piezo
stages, large XYZ Theta stages and other special customized solutions.
Founded in 1999, PBA Systems continuously aims for technological breakthroughs and innovations, working to deliver
the best products to our customers while providing excellent service and uncompromising quality standards. For
enquiries on any of our products, email us at sales@pbasystems.com.sg or call us at +65 6576 6767
5 0 1 8 3 5 0 1 5 0 1 8 5 3 8 18
the leader in linear motors
motor modules servo drives motion control cards
software encoders & cables mechanical design& fabrication
+ +
+ + +
= complete solution
PAGE 03
GLOBAL SUPPORT
MAKING IT GOOD & MAKING IT CHEAP
FAST REACTION & SHORT LEAD TIME
PBA SYSTEMS products are well covered with world-wide distrbutors and local offices.
We are vertically integrated with factories in China that supply the motor magnets.South East Asian factories for machining and assembly.
We hold vast stocks of work in progress parts. We are equipped to accomodate highly customised designs.PBA staffs work around the clock to deliver goods on time.
BRANCH OFFICE
DISTRIBUTORS
global locations
USA
India
Israel
ItalySwitzerland
Germany
Korea
IndonesiaSingapore
MalaysiaThailand
Philippines
Taiwan
China
Linear Motors PA R T N U M B E R I N G
PAGE 04
Coil Assembly DX50B – C4 – P – TM – 2.0 – A – FC
Magnet Track
We reserve the right to make technical changes at any time without prior notice
DX Series Part Numbering System
DX50B – TL300 – K2
Remarks: TM – On/Off switch TC – With a simple temperature controller (e.g. Omron), user can read the temperature all the time on a display. User can also set a temperature in
the controller to trigger an output Minimum Bending Radius - 10 times of cable diameter
Motor Model
DX10B DX20B DX30B DX30BT DX50B DX50BT DX65B DX65BT DX90B DX90BT
Motor Coil Size
C1
C2
C3
C4
C5
:
Connection Type S - Series
P - Parallel
Thermal Protection
TM - Thermostat Available as a standard for DX30B, DX30BT, DX50B, DX50BT, DX65B, DX65BT, DX90B, DX95BT (Not available for DX20B)
TC - PT 100 Sensor Available as a standard for DX10B, DX20B (Optional for DX30B, DX30BT, DX50B, DX50BT, DX65B, DX65BT, DX90B, DX90BT)
Cable Length 2.0 m
3.0 m
5.0 m
Cooling Type
Blank - Standard Type (No cooling)
A - Air Cooling
Option #1
FC - Ferrite Core (Standard)
Blank - Without Ferrite Core (Not Recommended)
Option #2
HC - Hall Connector (Standard)
Blank – No HC
– HC
Remarks: Track length in incremental of 60mm
DX B Series
Motor Model
DX10B DX20B DX30B DX30BT DX50B DX50BT DX65B DX65BT DX90B DX90BT
Magnet Track Length
TL180 - 180mm
TL300 - 300mm
TL600 - 600mm
TL900 - 900mm
Magnet Track Length
Blank - No Customization
K1, K2, K3, K4, K5, K6.. - Customized according to customer’s specifications
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 10B • Ironless Motor • Peak force to 63N, Continuous force to 12N • Ideal for high precision/smooth motion
S P E C I F I C A T I O N S
PAGE 05
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
PerformanceUnit DX10B-C1 DX10B-C2 DX10B-C3 DX10B-C4
S S S SPeak Force N 15.8 31.6 47.5 63.3Continuous Force @ 120ºC* N 3.2 6.3 9.5 12.7Peak Power @ 120ºC W 316 631 947 1262Continuous Power @ 120ºC* W 12.6 25.2 37.9 50.5
ElectricalUnit DX10B-C1 DX10B-C2 DX10B-C3 DX10B-C4
S S S SPeak Current Apk 14.01 14.01 14.01 14.01Continuous Current @ 120ºC* Apk 2.80 2.80 2.80 2.80Continuous Stall Current @ 120ºC* Arms 1.98 1.98 1.98 1.98Force Constant N/Apk 1.1 2.3 3.4 4.5Back EMF Constant Vpk/m/s 1.3 2.6 3.9 5.2Coil Resistance L-L @ 25ºC ohm 1.6 3.1 4.7 6.2Coil Resistance L-L @ 120ºC* ohm 2.1 4.3 6.4 8.6Inductance L-L @ 1kHz mH 0.11 0.22 0.33 0.44Motor Constant @ 25ºC* N/√W 1.05 1.48 1.81 2.09Motor Constant @ 120ºC* N/√W 0.89 1.26 1.54 1.78Max. Terminal Voltage Vdc 60 60 60 60
ThermalUnit DX10B-C1 DX10B-C2 DX10B-C3 DX10B-C4
S S S SThermal Resistance @ 120ºC* ºC/W 7.53 3.76 2.51 1.88Max. Coil Temperature ºC 120 120 120 120
MechanicalUnit DX10B-C1 DX10B-C2 DX10B-C3 DX10B-C4
S S S SCoil Weight kg 0.02 0.04 0.06 0.08Coil Length mm 22 43 64 85Attractive Force N 0 0 0 0Electrical Cycle Length mm 21 21 21 21
Notes:1. Apk = 1.414 * Arms; Vpk = 1.414 * Vrms.2. * Ambient temperature 25ºC, natural convection, no heat sink.3. Specifications tolerance – inductance +/-30%, all others +/-10%.4. Peak force and current - 4% duty ratio and 1 second duration.
Highest Force in Compact Size for Point-to-Point Motion Systems
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 10B
S P E C I F I C A T I O N S
PAGE 06
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
DX10B Standard Magnet Track
SIZE TRACK LENGTH TL (mm) WEIGHT (kg) MOUNT HOLE G (ea) MOUNT HOLE H (ea) TL 63 62.7 0.15 2 3 TL 84 83.7 0.20 3 4 TL 105 104.7 0.25 4 5
TRACK WEIGHT = 0.15kg PER 63mm.
DX10B Motor Coil
SIZE COIL LENGTH CL (mm) WEIGHT (kg) MOUNT HOLE E (ea) MOUNT HOLE A (ea) C1 22.0 0.02 4 12.0 C2 43.0 0.04 6 16.0 C3 64.0 0.06 8 16.0
For COOLING OPTIONS, please ask for detail drawing.
85.0 16.0C4 0.08 10
3.5
20.921.0(PITCH)
TRACK LENGTH
42.0
0.3
6.0 3.0 BOTH SIDESG- 3.5 THRU
COMBINE TRACKS
CLEARANCE
21.6
9.7
25.4
36.0
21.6
5.0A(PITCH)
COIL LENGTH
14.0
E-M2.5 5.0
MOTOR CABLE
10.8
13.8521.0(PITCH)
H- M3 THRU'
21.0
Highest Force in Compact Size for Point-to-Point Motion Systems
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 20B • Ironless Motor • Peak force to 229N, Continuous force to 60N • Integrated with Hall Sensor • Ideal for high precision/smooth motion
Notes:1. Apk = 1.414 * Arms; Vpk = 1.414 * Vrms.2. * Ambient temperature 25ºC, natural convection, no heat sink.
4. Specifications tolerance – inductance +/-30%, all others +/-10%.5. Peak force and current - 4% duty ratio and 1 second duration.
PerformanceUnit
S P S P S P S PPeak Force N 92 92 137 137 183 183 229 229Continuous Force @ 120ºC* N 18 18 27 27 37 37 46 46Continuous Force AC @ 120ºC^ N 24 24 36 36 48 48 60 60Peak Power @ 120ºC W 744 744 1116 1116 1488 1488 1860 1860Continuous Power @ 120ºC* W 30 30 45 45 60 60 74 74Continuous Power AC @ 120ºC^ W 50 50 75 75 101 101 126 126
ElectricalUnit
S P S P S P S PPeak Current Apk 10.50 21.00 10.50 21.00 10.50 21.00 10.50 21.00Continuous Current @ 120ºC* Apk 2.10 4.20 2.10 4.20 2.10 4.20 2.10 4.20Continuous Current AC @ 120ºC^ Apk 2.73 5.46 2.73 5.46 2.73 5.46 2.73 5.46Continuous Stall Current @ 120ºC* Arms 1.40 2.80 1.40 2.80 1.40 2.80 1.40 2.80Force Constant N/Apk 8.7 4.4 13.1 6.5 17.4 8.7 21.8 10.9Back EMF Constant Vpk/m/s 10.0 5.0 15.0 7.5 20.1 10.0 25.1 12.5Coil Resistance L-L @ 25ºC ohm 6.5 1.6 9.8 2.4 13.0 3.3 16.3 4.1Coil Resistance L-L @ 120ºC* ohm 9.0 2.2 13.5 3.4 18.0 4.5 22.5 5.6Inductance L-L @ 1kHz mH 1.53 0.38 2.30 0.57 3.06 0.77 3.83 0.96Motor Constant @ 25ºC* N/√W 3.95 3.95 4.84 4.84 5.59 5.59 6.24 6.24Motor Constant @ 120ºC* N/√W 3.36 3.36 4.11 4.11 4.75 4.75 5.31 5.31Max. Terminal Voltage Vdc 400 400 400 400 400 400 400 400
ThermalUnit
S P S P S P S PThermal Resistance @ 120ºC* ºC/W 3.19 3.19 2.13 2.13 1.60 1.60 1.28 1.28Thermal Resistance AC @ 120ºC^ ºC/W 1.89 1.89 1.26 1.26 0.94 0.94 0.76 0.76Max. Coil Temperature ºC 120 120 120 120 120 120 120 120
MechanicalUnit
S P S P S P S PCoil Weight kg 0.11 0.11 0.17 0.17 0.23 0.23 0.28 0.28Coil Weight AC^ kg 0.11 0.11 0.17 0.17 0.23 0.23 0.28 0.28Coil Length mm 61 61 91 91 121 121 151 151Attractive Force N 0 0 0 0 0 0 0 0Electrical Cycle Length mm 30 30 30 30 30 30 30 30
DX20B-C5
DX20B-C5
DX20B-C5
DX20B-C4
DX20B-C4
DX20B-C4
DX20B-C4
DX20B-C2 DX20B-C3
DX20B-C2 DX20B-C3
DX20B-C2 DX20B-C3
DX20B-C2 DX20B-C3
DX20B-C5
S P E C I F I C A T I O N S
PAGE 07
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 20B
S P E C I F I C A T I O N S
PAGE 08
DX20B Standard Magnet Track
SIZE TRACK LENGTH TL (mm) WEIGHT (kg) MOUNT HOLE A (ea) MOUNT HOLE B (ea) TL 120 119.7 0.44 2 2 TL 180 179.7 0.66 3 3 TL 240* 239.7 0.88 4 4 TL 300 299.7 1.10 5 5 TL 360 359.7 1.32 6 6 TL 480 479.7 1.76 8 8
*EX-STOCK LENGTH TRACK WEIGHT = 0.22kg PER 60mm.
For COOLING OPTIONS, please ask for detail drawing.
6.036.573.0
109.5
3.0 M3 6.0-M3 THRU
COIL LENGTH
29.8560.0(PITCH)
4.6
6.0 3.2(BOTH SIDES)-M4 THRU
CABLE OUT
3.037.5
36.573.0
16.6
121.0(C4)
M3 6.0
61.0(C2)91.0(C3)
FLEXIBLE CABLE 3.3 FOR HALLFLEXIBLE CABLE 5.6 FOR POWER0.
02.
37.
510
.5
10.5
0.0
10.6
10.6
0.0
7.9
38.139.151.352.055.6
29.8560.0(PITCH)TRACK LENGTH
-M5 THRU
D-
E
B
A
TL
CL
DX20B Motor Coil
SIZE COIL LENGTH CL (mm) WEIGHT (kg) MOUNT HOLE D (ea) MOUNT HOLE E (ea) C2 61.0 0.11 3 2 C3 91.0 0.17 5 3 C4 121.0 0.23 7 4 C5 151.0 0.28
9 5
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
S P E C I F I C A T I O N S
PAGE 09
DX 30B / DX 30BT • Ironless Motor • Peak force to 724N, Continuous force to 188N • Integrated with Hall Sensor • Ideal for high precision/smooth motion
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
PerformanceUnit DX30BT-C2
S P S P P S PPeak Force N 145 145 289 289 289 434 434Continuous Force @ 120ºC* N 29 29 58 58 58 87 87Continuous Force AC @ 120ºC^ N 38 38 75 75 75 113 113Peak Power @ 120ºC W 695 695 1390 1390 1390 2086 2086Continuous Power @ 120ºC* W 28 28 56 56 56 83 83Continuous Power AC @ 120ºC^ W 47 47 94 94 94 141 141
ElectricalUnit DX30BT-C2
S P S P P S PPeak Current Apk 11.81 23.63 11.81 23.63 47.25 11.81 23.63Continuous Current @ 120ºC* Apk 2.36 4.73 2.36 4.73 9.45 2.36 4.73Continuous Current AC @ 120ºC^ Apk 3.07 6.14 3.07 6.14 12.29 3.07 6.14Continuous Stall Current @ 120ºC* Arms 1.75 3.50 1.75 3.50 7.00 1.75 3.50Force Constant N/Apk 12.3 6.1 24.5 12.3 6.1 36.8 18.4Back EMF Constant Vpk/m/s 14.1 7.0 28.2 14.1 7.0 42.3 21.1Coil Resistance L-L @ 25ºC ohm 4.8 1.2 9.6 2.4 0.6 14.4 3.6Coil Resistance L-L @ 120ºC* ohm 6.6 1.7 13.3 3.3 0.8 19.9 5.0Inductance L-L @ 1kHz mH 3.00 0.75 6.00 1.50 0.38 9.00 2.25Motor Constant @ 25ºC* N/√W 6.46 6.46 9.13 9.13 9.13 11.18 11.18Motor Constant @ 120ºC* N/√W 5.49 5.49 7.76 7.76 7.76 9.51 9.51Max. Terminal Voltage Vdc 400 400 400 400 400 400 400
ThermalUnit DX30BT-C2
S P S P P S PThermal Resistance @ 120ºC* ºC/W 3.42 3.42 1.71 1.71 1.71 1.14 1.14Thermal Resistance AC @ 120ºC^ ºC/W 2.02 2.02 1.01 1.01 1.01 0.67 0.67Max. Coil Temperature ºC 120 120 120 120 120 120 120
MechanicalUnit DX30BT-C2
S P S P P S PCoil Weight kg 0.21 0.21 0.41 0.41 0.43 0.62 0.62Coil Weight AC^ kg 0.23 0.23 0.46 0.46 0.48 0.69 0.69Coil Length mm 61 61 121 121 121 181 181Attractive Force N 0 0 0 0 0 0 0Electrical Cycle Length mm 60 60 60 60 60 60 60
Notes:1. Apk = 1.414 * Arms; Vpk = 1.414 * Vrms.2. * Ambient temperature 25ºC, natural convection, no heat sink.
4. Specifications tolerance – inductance +/-30%, all others +/-10%.5. Peak force and current - 4% duty ratio and 1 second duration.
DX30B-C2 DX30B-C3
DX30B-C1
DX30B-C1
DX30B-C1
DX30B-C1
DX30B-C2 DX30B-C3
DX30B-C2 DX30B-C3
DX30B-C2 DX30B-C3
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
S P E C I F I C A T I O N S
PAGE 10
DX 30B / DX 30BT • Ironless Motor •• Integrated with Hall Sensor • Ideal for high precision/smooth motion
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
Peak force to 724N, Continuous force to 188N
PerformanceUnit DX30BT-C4
S P P S PPeak Force N 579 579 579 724 724Continuous Force @ 120ºC* N 116 116 116 145 145Continuous Force AC @ 120ºC^ N 150 150 150 188 188Peak Power @ 120ºC W 2781 2781 2781 3476 3476Continuous Power @ 120ºC* W 111 111 111 139 139Continuous Power AC @ 120ºC^ W 188 188 188 235 235
ElectricalUnit DX30BT-C4
S P P S PPeak Current Apk 11.81 23.63 47.25 11.81 23.63Continuous Current @ 120ºC* Apk 2.36 4.73 9.45 2.36 4.73Continuous Current AC @ 120ºC^ Apk 3.07 6.14 12.29 3.07 6.14Continuous Stall Current @ 120ºC* Arms 1.75 3.50 7.00 1.75 3.50Force Constant N/Apk 49.0 24.5 12.3 61.3 30.6Back EMF Constant Vpk/m/s 56.4 28.2 14.1 70.4 35.2Coil Resistance L-L @ 25ºC ohm 19.2 4.8 1.2 24.0 6.0Coil Resistance L-L @ 120ºC* ohm 26.6 6.6 1.7 33.2 8.3Inductance L-L @ 1kHz mH 12.00 3.00 0.75 15.00 3.75Motor Constant @ 25ºC* N/√W 12.91 12.91 12.91 14.44 14.44Motor Constant @ 120ºC* N/√W 10.98 10.98 10.98 12.27 12.27Max. Terminal Voltage Vdc 400 400 400 400 400
ThermalUnit DX30BT-C4
S P P S PThermal Resistance @ 120ºC* ºC/W 0.85 0.85 0.85 0.68 0.68Thermal Resistance AC @ 120ºC^ ºC/W 0.51 0.51 0.51 0.40 0.40Max. Coil Temperature ºC 120 120 120 120 120
MechanicalUnit DX30BT-C4
S P P S PCoil Weight kg 0.83 0.83 0.88 1.04 1.04Coil Weight AC^ kg 0.93 0.93 0.97 1.16 1.16Coil Length mm 241 241 241 301 301Attractive Force N 0 0 0 0 0Electrical Cycle Length mm 60 60 60 60 60
Notes:1. Apk = 1.414 * Arms; Vpk = 1.414 * Vrms.2. * Ambient temperature 25ºC, natural convection, no heat sink.
4. Specifications tolerance – inductance +/-30%, all others +/-10%.5. Peak force and current - 4% duty ratio and 1 second duration.
DX30B-C4 DX30B-C5
DX30B-C4 DX30B-C5
DX30B-C4 DX30B-C5
DX30B-C4 DX30B-C5
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 30B / 30BT
S P E C I F I C A T I O N S
PAGE 11
DX30B Standard Magnet Track
SIZE TRACK LENGTH TL (mm) WEIGHT (kg) MOUNT HOLE A (ea) MOUNT HOLE B (ea) TL 120 119.5 1.14 2 2 TL 180 179.5 1.71 3 3 TL 240 239.5 2.28 4 4 TL 300 299.5 2.85 5 5 TL 360 359.5 3.42 6 6 TL 480* 479.5 4.56 8 8
*EX-STOCK LENGTH TRACK WEIGHT = 0.57kg PER 60mm.
DX30B Motor Coil DX30BT Motor Coil
SIZE COIL LENGTH CL (mm)
WEIGHT (kg) WEIGHT (kg) Air Cool
MOUNT HOLE D (ea)
C1 61.0 0.21 0.23 3 C2 121.0 0.41 0.46 7 C3 181.0 0.62 0.69 11 C4 241.0 0.83 0.93 15 C5 301.0 1.04 1.16 19
SIZE COIL LENGTH CL (mm)
WEIGHT (kg) WEIGHT (kg) Air Cool
MOUNT HOLE D (ea)
C2 121.0 0.43 0.48 C4 241.0 0.88 0.97
For COOLING OPTIONS, please ask for detail drawing.
715
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
COIL LENGTH
29.7560.0(PITCH)7.3 6.35(BOTH SIDES)-M5 THRU
4.25
CABLE OUT
28.0
301.0(C5)
-M4 THRU45.530.0(PITCH)
2.5
61.0(C1)121.0(C2)
181.0(C3)
241.0(C4)
0.0
17.5
17.5
13.7
0.0
8.5
50.852.155.261.268.5 (+2.0 for DX 30BT)
0.0
17.8
5
17.8
5
FLEXIBLE CABLE 5.6 FOR POWER
FLEXIBLE CABLE 3.3 FOR HALL
TRACK LENGTH
22.2560.0
-M5 TRHUA
12.035.0
4.5
35.7
20.5
72.6
M5 10.0 FOR AIR INPUT
B
TL
D
CL
AIR COOLED COILSTANDARD COIL
(+2.0 for DX 30BT)
S P E C I F I C A T I O N S
PAGE 12
SYSTEMS M A K E S A D I F F E R E N C Ewww.pbasystems.com.sg
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 50B / 50BT • Ironless Motor • Peak force to 1339N, Continuous force to 348N• Integrated with Hall Sensor • Ideal for high precision/smooth motion
PerformanceUnit DX50BT-C2
S P S P P S PPeak Force N 223 223 446 446 446 669 669Continuous Force @ 120ºC* N 45 45 89 89 89 134 134Continuous Force AC @ 120ºC^ N 58 58 116 116 116 174 174Peak Power @ 120ºC W 751 751 1502 1502 1502 2253 2253Continuous Power @ 120ºC* W 30 30 60 60 60 90 90Continuous Power AC @ 120ºC^ W 51 51 102 102 102 152 152
ElectricalUnit DX50BT-C2
S P S P P S PPeak Current Apk 13.13 26.25 13.13 26.25 52.50 13.13 26.25Continuous Current @ 120ºC* Apk 2.63 5.25 2.63 5.25 10.50 2.63 5.25Continuous Current AC @ 120ºC^ Apk 3.41 6.83 3.41 6.83 13.65 3.41 6.83Continuous Stall Current @ 120ºC* Arms 2.10 4.20 2.10 4.20 8.40 2.10 4.20Force Constant N/Apk 17.0 8.5 34.0 17.0 8.5 51.0 25.5Back EMF Constant Vpk/m/s 19.6 9.8 39.1 19.6 9.8 58.7 29.3Coil Resistance L-L @ 25ºC ohm 4.2 1.1 8.4 2.1 0.5 12.6 3.2Coil Resistance L-L @ 120ºC* ohm 5.8 1.5 11.6 2.9 0.7 17.4 4.4Inductance L-L @ 1kHz mH 3.11 0.78 6.22 1.56 0.39 9.33 2.33Motor Constant @ 25ºC* N/√W 9.58 9.58 13.55 13.55 13.55 16.59 16.59Motor Constant @ 120ºC* N/√W 8.14 8.14 11.51 11.51 11.51 14.10 14.10Max. Terminal Voltage Vdc 400 400 400 400 400 400 400
ThermalUnit DX50BT-C2
S P S P P S PThermal Resistance @ 120ºC* ºC/W 3.16 3.16 1.58 1.58 1.58 1.05 1.05Thermal Resistance AC @ 120ºC^ ºC/W 1.87 1.87 0.94 0.94 0.94 0.62 0.62Max. Coil Temperature ºC 120 120 120 120 120 120 120
MechanicalUnit DX50BT-C2
S P S P P S PCoil Weight kg 0.25 0.25 0.52 0.52 0.54 0.76 0.76Coil Weight AC^ kg 0.28 0.28 0.57 0.57 0.60 0.85 0.85Coil Length mm 61 61 121 121 121 181 181Attractive Force N 0 0 0 0 0 0 0Electrical Cycle Length mm 60 60 60 60 60 60 60
Notes:1. Apk = 1.414 * Arms; Vpk = 1.414 * Vrms.2. * Ambient temperature 25ºC, natural convection, no heat sink.
4. Specifications tolerance – inductance +/-30%, all others +/-10%.5. Peak force and current - 4% duty ratio and 1 second duration.
DX50B-C2 DX50B-C3
DX50B-C1
DX50B-C1
DX50B-C1
DX50B-C1
DX50B-C2 DX50B-C3
DX50B-C2 DX50B-C3
DX50B-C2 DX50B-C3
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
S P E C I F I C A T I O N S
PAGE 13
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 50B / 50BT • Ironless Motor • Peak force to 1339N, Continuous force to 348N• Integrated with Hall Sensor • Ideal for high precision/smooth motion
PerformanceUnit DX50BT-C4 DX50BT-C6
S P P S P PPeak Force N 893 893 893 1116 1116 1339Continuous Force @ 120ºC* N 179 179 179 223 223 268Continuous Force AC @ 120ºC^ N 232 232 232 290 290 348Peak Power @ 120ºC W 3004 3004 3004 3755 3755 4506Continuous Power @ 120ºC* W 120 120 120 150 150 180Continuous Power AC @ 120ºC^ W 203 203 203 254 254 305
ElectricalUnit DX50BT-C4 DX50BT-C6
S P P S P PPeak Current Apk 13.13 26.25 52.50 13.13 26.25 52.50Continuous Current @ 120ºC* Apk 2.63 5.25 10.50 2.63 5.25 10.50Continuous Current AC @ 120ºC^ Apk 3.41 6.83 13.65 3.41 6.83 13.65Continuous Stall Current @ 120ºC* Arms 2.10 4.20 8.40 2.10 4.20 8.40Force Constant N/Apk 68.0 34.0 17.0 85.0 42.5 25.5Back EMF Constant Vpk/m/s 78.2 39.1 19.6 97.8 48.9 29.3Coil Resistance L-L @ 25ºC ohm 16.8 4.2 1.1 21.0 5.3 1.6Coil Resistance L-L @ 120ºC* ohm 23.2 5.8 1.5 29.1 7.3 2.2Inductance L-L @ 1kHz mH 12.44 3.11 0.78 15.55 3.89 1.17Motor Constant @ 25ºC* N/√W 19.16 19.16 19.16 21.42 21.42 23.46Motor Constant @ 120ºC* N/√W 16.28 16.28 16.28 18.21 18.21 19.94Max. Terminal Voltage Vdc 400 400 400 400 400 400
ThermalUnit DX50BT-C4 DX50BT-C6
S P P S P PThermal Resistance @ 120ºC* ºC/W 0.79 0.79 0.79 0.63 0.63 0.53Thermal Resistance AC @ 120ºC^ ºC/W 0.47 0.47 0.47 0.37 0.37 0.31Max. Coil Temperature ºC 120 120 120 120 120 120
MechanicalUnit DX50BT-C4 DX50BT-C6
S P P S P PCoil Weight kg 1.07 1.07 1.05 1.25 1.25 1.58Coil Weight AC^ kg 1.19 1.19 1.17 1.40 1.40 1.75Coil Length mm 241 241 241 301 301 361Attractive Force N 0 0 0 0 0 0Electrical Cycle Length mm 60 60 60 60 60 60
Notes:1. Apk = 1.414 * Arms; Vpk = 1.414 * Vrms.2. * Ambient temperature 25ºC, natural convection, no heat sink.
4. Specifications tolerance – inductance +/-30%, all others +/-10%.5. Peak force and current - 4% duty ratio and 1 second duration.
DX50B-C4 DX50B-C5
DX50B-C4 DX50B-C5
DX50B-C4 DX50B-C5
DX50B-C4 DX50B-C5
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 50B / 50BT
S P E C I F I C A T I O N S
PAGE 14
DX50B Standard Magnet Track
SIZE TRACK LENGTH TL (mm) WEIGHT (kg) MOUNT HOLE A (ea) MOUNT HOLE B (ea) TL 120 119.5 1.73 2 2 TL 180 179.5 2.60 3 3 TL 240 239.5 3.46 4 4 TL 300 299.5 4.33 5 5 TL 360 359.5 5.20 6 6 TL 480* 479.5 6.92 10 10
*EX-STOCK LENGTH TRACK WEIGHT = 0.866kg PER 60mm.
DX50B Motor Coil DX50BT Motor Coil SIZE COIL LENGTH
CL (mm) WEIGHT (kg) WEIGHT (kg)
Air Cool MOUNT
HOLE D (ea) C1 61.0 0.25 0.28 3 C2 121.0 0.52 0.57 7 C3 181.0 0.76 0.85 11 C4 241.0 1.07 1.19 15 C5 301.0 1.25 1.40 19
SIZE COIL LENGTH CL (mm)
WEIGHT (kg) WEIGHT (kg) Air Cool
MOUNT HOLE D (ea)
C2 121.0 0.54 0.60 C4 241.0 1.05 1.17 C6 361.0 1.58 1.75
For COOLING OPTIONS, please ask for detail drawing.
71523
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
COIL LENGTH
6.0
29.7560.0(PITCH)9.0 6.35(BOTH SIDES)
B-M6 THRU'
CABLE OUTCL
6.0
30.0
241.0(C4)
-M4 THRU 30.0(PITCH)
61.0(C1)121.0(C2)181.0(C3)
TRACK LENGTH 29.7560.0(PITCH)
A-M6 THRU'
D
TL
0.0
12.7
76.277.480.086.093.0 (+2.0 for DX 50BT)
0.0
19.1
13.9
19.1
0.0
19.3
5
19.3
5
FLEXIBLE CABLE 3.3 FOR HALL
FLEXIBLE CABLE 5.6 FOR POWER
12.0
38.2
5.0
20.1
97.5
M5 10.0 FOR AIR INPUT
38.7
AIR COOLED COILSTANDARD COIL
(+2.0 for DX 50BT)
40.0
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 65B / 65BT • Ironless Motor • Peak force to 5191N, Continuous force to 1038N • Integrated with Hall Sensor • Ideal for high precision/smooth motion
PerformanceUnit DX65BT-C6
S P S P S P S P S P PPeak Force N 692 692 1038 1038 1384 1384 1730 1730 2077 2077 2077Continuous Force @ 120ºC* N 138 138 208 208 277 277 346 346 415 415 415Continuous Force AC @ 120ºC^ N 173 173 260 260 346 346 415 415 498 498 498Peak Power @ 120ºC W 1951 1951 2927 2927 3902 3902 4878 4878 5854 5854 5854Continuous Power @ 120ºC* W 78 78 117 117 156 156 195 195 234 234 234Continuous Power AC @ 120ºC^ W 122 122 183 183 244 244 281 281 337 337 337
ElectricalUnit DX65BT-C6
S P S P S P S P S P PPeak Current Apk 15.63 31.25 15.63 31.25 15.63 31.25 15.63 31.25 15.63 31.25 62.50Continuous Current @ 120ºC* Apk 3.13 6.25 3.13 6.25 3.13 6.25 3.13 6.25 3.13 6.25 12.50Continuous Current AC @ 120ºC^ Apk 3.91 7.81 3.91 7.81 3.91 7.81 3.75 7.50 3.75 7.50 15.00Continuous Stall Current @ 120ºC* Arms 2.50 5.00 2.50 5.00 2.50 5.00 2.50 5.00 2.50 5.00 10.00Force Constant N/Apk 44.3 22.2 66.5 33.2 88.6 44.3 110.8 55.4 132.9 66.5 33.2Back EMF Constant Vpk/m/s 50.9 25.5 76.4 38.2 101.9 50.9 127.4 63.7 152.8 76.4 38.2Coil Resistance L-L @ 25ºC ohm 7.7 1.9 11.6 2.9 15.4 3.9 19.3 4.8 23.1 5.8 1.4Coil Resistance L-L @ 120ºC* ohm 10.7 2.7 16.0 4.0 21.3 5.3 26.6 6.7 32.0 8.0 2.0Inductance L-L @ 1kHz mH 9.11 2.28 13.67 3.42 18.22 4.56 22.78 5.69 27.33 6.83 1.71Motor Constant @ 25ºC* N/√W 18.4 18.4 22.6 22.6 26.1 26.1 29.1 29.1 31.9 31.9 31.9Motor Constant @ 120ºC* N/√W 15.7 15.7 19.2 19.2 22.2 22.2 24.8 24.8 27.1 27.1 27.1Max. Terminal Voltage Vdc 600 600 600 600 600 600 600 600 600 600 600
ThermalUnit DX65BT-C6
S P S P S P S P S P PThermal Resistance @ 120ºC* ºC/W 1.22 1.22 0.81 0.81 0.61 0.61 0.49 0.49 0.41 0.41 0.41Thermal Resistance AC @ 120ºC^ ºC/W 0.78 0.78 0.52 0.52 0.39 0.39 0.34 0.34 0.28 0.28 0.28Max. Coil Temperature ºC 120 120 120 120 120 120 120 120 120 120 120
MechanicalUnit DX65BT-C6
S P S P S P S P S P PCoil Weight kg 1.05 1.05 1.57 1.57 2.09 2.09 2.61 2.61 3.13 3.13 3.23Coil Weight AC^ kg 1.13 1.13 1.69 1.69 2.25 2.25 2.81 2.81 3.37 3.37 3.47Coil Length mm 121 121 181 181 241 241 301 301 361 361 361Attractive Force N 0 0 0 0 0 0 0 0 0 0 0Electrical Cycle Length mm 60 60 60 60 60 60 60 60 60 60 60
Notes:1. Apk = 1.414 * Arms; Vpk = 1.414 * Vrms.2. * Ambient temperature 25ºC, natural convection, no heat sink.
4. Specifications tolerance – inductance +/-30%, all others +/-10%.5. Peak force and current - 4% duty ratio and 1 second duration.
DX65B-C2 DX65B-C3
DX65B-C2 DX65B-C3
DX65B-C5
DX65B-C5
DX65B-C5
DX65B-C5
DX65B-C2 DX65B-C3
DX65B-C2 DX65B-C3 DX65B-C4
DX65B-C4
DX65B-C4
DX65B-C4 DX65B-C6
DX65B-C6
DX65B-C6
DX65B-C6
S P E C I F I C A T I O N S
PAGE 15
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 65B / 65BT • Ironless Motor • Peak force to 5191N, Continuous force to 1038N • Integrated with Hall Sensor • Ideal for high precision/smooth motion
PerformanceUnit DX65BT-C8 DX65BT-C10 DX65BT-C12 DX65BT-C15
S P P S P P P PPeak Force N 2769 2769 2769 3461 3461 3461 4153 5191Continuous Force @ 120ºC* N 554 554 554 692 692 692 831 1038Continuous Force AC @ 120ºC^ NPeak Power @ 120ºC W 7805 7805 7805 9756 9756 9756 11707 14634Continuous Power @ 120ºC* W 312 312 312 390 390 390 468 585Continuous Power AC @ 120ºC^ W
ElectricalUnit DX65BT-C8 DX65BT-C10 DX65BT-C12 DX65BT-C15
S P P S P P P PPeak Current Apk 15.63 31.25 62.50 15.63 31.25 62.50 62.50 93.75Continuous Current @ 120ºC* Apk 3.13 6.25 12.50 3.13 6.25 12.50 12.50 18.75Continuous Current AC @ 120ºC^ Apk
Continuous Stall Current @ 120ºC* Arms 2.50 5.00 10.00 2.50 5.00 10.00 10.00 15.00Force Constant N/Apk 177.2 88.6 44.3 221.5 110.8 55.4 66.5 55.4Back EMF Constant Vpk/m/s 203.8 101.9 50.9 254.7 127.4 63.7 76.4 63.7Coil Resistance L-L @ 25ºC ohm 30.8 7.7 1.9 38.5 9.6 2.4 2.9 1.6Coil Resistance L-L @ 120ºC* ohm 42.6 10.7 2.7 53.3 13.3 3.3 4.0 2.2Inductance L-L @ 1kHz mH 36.44 9.11 2.28 45.55 11.39 2.85 3.42 1.90Motor Constant @ 25ºC* N/√W 36.9 36.9 36.9 41.2 41.2 41.2 45.2 50.5Motor Constant @ 120ºC* N/√W 31.3 31.3 31.3 35.0 35.0 35.0 38.4 42.9Max. Terminal Voltage Vdc 600 600 600 600 600 600 600 600
ThermalUnit DX65BT-C8 DX65BT-C10 DX65BT-C12 DX65BT-C15
S P P S P P P PThermal Resistance @ 120ºC* ºC/W 0.30 0.30 0.30 0.24 0.24 0.24 0.20 0.16Thermal Resistance AC @ 120ºC^ ºC/WMax. Coil Temperature ºC 120 120 120 120 120 120 120 120
MechanicalUnit DX65BT-C8 DX65BT-C10 DX65BT-C12 DX65BT-C15
S P P S P P P PCoil Weight kg 4.36 4.36 4.43 5.45 5.45 5.54 6.64 8.55Coil Weight AC^ kgCoil Length mm 481 481 481 601 601 601 721 901Attractive Force N 0 0 0 0 0 0 0 0Electrical Cycle Length mm 60 60 60 60 60 60 60 60
Notes:1. Apk = 1.414 * Arms; Vpk = 1.414 * Vrms.2. * Ambient temperature 25ºC, natural convection, no heat sink.
4. Specifications tolerance – inductance +/-30%, all others +/-10%.5. Peak force and current - 4% duty ratio and 1 second duration.
DX65B-C8 DX65B-C10
DX65B-C8 DX65B-C10
DX65B-C8 DX65B-C10
DX65B-C8 DX65B-C10
S P E C I F I C A T I O N S
PAGE 16
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 65B / 65BT
S P E C I F I C A T I O N S
PAGE 17
DX65B Standard Magnet Track
SIZE TRACK LENGTH TL (mm) WEIGHT (kg) MOUNT HOLE A (ea) MOUNT HOLE B (ea) TL 180 179.5 4.50 3 3 TL 240 239.5 6.00 4 4 TL 300 299.5 7.50 5 5 TL 360 359.5 9.00 6 6 TL 600 599.5 15.00 10 10 TL 900* 899.5 22.50 15 15
*EX-STOCK LENGTH TRACK WEIGHT = 1.5kg PER 60mm.
DX65B Motor Coil DX65BT Motor Coil
SIZE COIL LENGTH CL (mm)
WEIGHT (kg) WEIGHT (kg) Air Cool
MOUNT HOLE D (ea)
C2 121.0 1.05 1.13 4 C3 181.0 1.57 1.69 6 C4 241.0 2.09 2.25 8 C5 301.0 2.61 2.81 C6 361.0 3.13 3.37 12 C8 481.0 4.36 16 C10 601.0 5.45 20
SIZE COIL LENGTH CL (mm)
WEIGHT (kg) WEIGHT (kg) Air Cool
MOUNT HOLE D (ea)
C6 361.0 3.23 3.47 C8 481.0 4.43 C10 601.0 5.54 C12 721.0 6.64 C15 901.0 8.55
For COOLING OPTIONS, please ask for detail drawing.
COIL LENGTH
29.7560.0(PITCH)9.0 (BOTH SIDES)-M6 THRU
6.5
CABLE OUT
-M5 THRU
39.0
51.060.0(PITCH)
121.0(C2)181.0(C3)
241.0(C4)
361.0(C6)481.0(C8)
601.0(C10)
50.0
TRACK LENGTH 29.7560.0(PITCH)-M6 THRU
D
CL
TLA
B
0.0
25.0
25.0
0.0
24.5
24.5
016.0
100.0101.4
122.0 (+2.0 for DX 65BT)
18.5
106.9112.0
FLEXIBLE CABLE 5.6 FOR POWER
FLEXIBLE CABLE 3.3 FOR HALL
12.049.0
5.0
25.6
127.
0
50.0
M5 10.0 FOR AIR INPUT
AIR COOLED COILSTANDARD COIL
1216202430
10
(+2.0 for DX 65BT)
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 90B / 90BT • Ironless Motor • Peak force to 5366N, Continuous force to 1073N • Integrated with Hall Sensor • Ideal for high precision/smooth motion
PerformanceUnit DX90BT-C6
S P S P S P S P PPeak Force N 894 894 1342 1342 1789 1789 2683 2683 2683Continuous Force @ 120ºC* N 179 179 268 268 358 358 537 537 537Continuous Force AC @ 120ºC^ N 215 215 322 322 429 429 617 617 617Peak Power @ 120ºC W 2217 2217 3325 3325 4433 4433 6650 6650 6650Continuous Power @ 120ºC* W 89 89 133 133 177 177 266 266 266Continuous Power AC @ 120ºC^ W 128 128 192 192 255 255 352 352 352
ElectricalUnit DX90BT-C6
S P S P S P S P PPeak Current Apk 16.88 33.75 16.88 33.75 16.88 33.75 16.88 33.75 67.50Continuous Current @ 120ºC* Apk 3.38 6.75 3.38 6.75 3.38 6.75 3.38 6.75 13.50Continuous Current AC @ 120ºC^ Apk 4.05 8.10 4.05 8.10 4.05 8.10 3.88 7.76 15.53Continuous Stall Current @ 120ºC* Arms 2.70 5.40 2.70 5.40 2.70 5.40 2.70 5.40 10.80Force Constant N/Apk 53.0 26.5 79.5 39.8 106.0 53.0 159.0 79.5 39.8Back EMF Constant Vpk/m/s 61.0 30.5 91.4 45.7 121.9 61.0 182.9 91.4 45.7Coil Resistance L-L @ 25ºC ohm 7.5 1.9 11.3 2.8 15.0 3.8 22.5 5.6 1.4Coil Resistance L-L @ 120ºC* ohm 10.4 2.6 15.6 3.9 20.8 5.2 31.1 7.8 1.9Inductance L-L @ 1kHz mH 8.51 2.13 12.77 3.19 17.03 4.26 25.54 6.39 1.60Motor Constant @ 25ºC* N/√W 22.3 22.3 27.4 27.4 31.6 31.6 38.7 38.7 38.7Motor Constant @ 120ºC* N/√W 19.0 19.0 23.3 23.3 26.9 26.9 32.9 32.9 32.9Max. Terminal Voltage Vdc 600 600 600 600 600 600 600 600 600
ThermalUnit DX90BT-C6
S P S P S P S P PThermal Resistance @ 120ºC* ºC/W 1.07 1.07 0.71 0.71 0.54 0.54 0.36 0.36 0.36Thermal Resistance AC @ 120ºC^ ºC/W 0.74 0.74 0.50 0.50 0.37 0.37 0.27 0.27 0.27Max. Coil Temperature ºC 120 120 120 120 120 120 120 120 120
MechanicalUnit DX90BT-C6
S P S P S P S P PCoil Weight kg 1.30 1.30 1.95 1.95 2.56 2.56 3.90 3.90 4.00Coil Weight AC^ kg 1.39 1.39 2.08 2.08 2.74 2.74 4.16 4.16 4.27Coil Length mm 121 121 181 181 241 241 361 361 361Attractive Force N 0 0 0 0 0 0 0 0 0Electrical Cycle Length mm 60 60 60 60 60 60 60 60 60
Notes:1. Apk = 1.414 * Arms; Vpk = 1.414 * Vrms.2. * Ambient temperature 25ºC, natural convection, no heat sink.
4. Specifications tolerance – inductance +/-30%, all others +/-10%.5. Peak force and current - 4% duty ratio and 1 second duration.
DX90B-C2 DX90B-C3
DX90B-C2 DX90B-C3
DX90B-C2 DX90B-C3
DX90B-C2 DX90B-C3
DX90B-C4
DX90B-C6
DX90B-C6DX90B-C4
DX90B-C4
DX90B-C4
DX90B-C6
DX90B-C6
S P E C I F I C A T I O N S
PAGE 18
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
S P E C I F I C A T I O N S
PAGE 19
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 90B / 90BT • Ironless Motor • Peak force to 5366N, Continuous force to 1073N • Integrated with Hall Sensor • Ideal for high precision/smooth motion
PerformanceUnit DX90BT-C8 DX90BT-C10 DX90BT-C12
S P P S P P PPeak Force N 3578 3578 3578 4472 4472 4472 5366Continuous Force @ 120ºC* N 716 716 716 894 894 894 1073Continuous Force AC @ 120ºC^ NPeak Power @ 120ºC W 8867 8867 8867 11084 11084 11084 13300Continuous Power @ 120ºC* W 355 355 355 443 443 443 532Continuous Power AC @ 120ºC^ W
ElectricalUnit DX90BT-C8 DX90BT-C10 DX90BT-C12
S P P S P P PPeak Current Apk 16.88 33.75 67.50 16.88 33.75 67.50 67.50Continuous Current @ 120ºC* Apk 3.38 6.75 13.50 3.38 6.75 13.50 13.50Continuous Current AC @ 120ºC^ Apk
Continuous Stall Current @ 120ºC* Arms 2.70 5.40 10.80 2.70 5.40 10.80 10.80Force Constant N/Apk 212.0 106.0 53.0 265.0 132.5 66.3 79.5Back EMF Constant Vpk/m/s 243.8 121.9 61.0 304.8 152.4 76.2 91.4Coil Resistance L-L @ 25ºC ohm 30.0 7.5 1.9 37.5 9.4 2.3 2.8Coil Resistance L-L @ 120ºC* ohm 41.5 10.4 2.6 51.9 13.0 3.2 3.9Inductance L-L @ 1kHz mH 34.06 8.51 2.13 42.57 10.64 2.66 3.19Motor Constant @ 25ºC* N/√W 44.7 44.7 44.7 50.0 50.0 50.0 54.7Motor Constant @ 120ºC* N/√W 38.0 38.0 38.0 42.5 42.5 42.5 46.5Max. Terminal Voltage Vdc 600 600 600 600 600 600 600
ThermalUnit DX90BT-C8 DX90BT-C10 DX90BT-C12
S P P S P P PThermal Resistance @ 120ºC* ºC/W 0.27 0.27 0.27 0.21 0.21 0.21 0.18Thermal Resistance AC @ 120ºC^ ºC/WMax. Coil Temperature ºC 120 120 120 120 120 120 120
MechanicalUnit DX90BT-C8 DX90BT-C10 DX90BT-C12
S P P S P P PCoil Weight kg 5.17 5.17 5.31 6.46 6.46 6.63 7.96Coil Weight AC^ kgCoil Length mm 481 481 481 601 601 601 721Attractive Force N 0 0 0 0 0 0 0Electrical Cycle Length mm 60 60 60 60 60 60 60
Notes:1. Apk = 1.414 * Arms; Vpk = 1.414 * Vrms.2. * Ambient temperature 25ºC, natural convection, no heat sink.
4. Specifications tolerance – inductance +/-30%, all others +/-10%.5. Peak force and current - 4% duty ratio and 1 second duration.
DX90B-C8 DX90B-C10
DX90B-C8 DX90B-C10
DX90B-C8 DX90B-C10
DX90B-C8 DX90B-C10
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
DX 90B / 90BT
S P E C I F I C A T I O N S
PAGE 20
DX90B Standard Magnet Track
SIZE TRACK LENGTH TL (mm) WEIGHT (kg) MOUNT HOLE A (ea) MOUNT HOLE B (ea) TL 240 239.5 8.50 4 4 TL 300 299.5 10.50 5 5 TL 360 359.5 12.50 6 6 TL 600 599.5 21.00 10 10 TL 900 899.5 31.50 15 15
TRACK WEIGHT = 2.1kg PER 60mm.
DX90B Motor Coil DX90BT Motor Coil
SIZE COIL LENGTH CL (mm)
WEIGHT (kg) WEIGHT (kg) Air Cool
MOUNT HOLE D (ea)
C2 121.0 1.30 1.39 4 C3 181.0 1.95 2.08 6 C4 241.0 2.56 2.74 8 C6 361.0 3.90 4.16 12 C8 481.0 5.17 16 C10 601.0 6.46 20
SIZE COIL LENGTH CL (mm)
WEIGHT (kg) WEIGHT (kg) Air Cool
MOUNT HOLE D (ea)
C6 361.0 4.00 4.27 C8 481.0 5.31 C10 601.0 6.63 C12 721.0 7.96
For COOLING OPTIONS, please ask for detail drawing.
12162024
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Highest Force in Compact Size for Point-to-Point Motion Systems
COIL LENGTH
29.7560.0(PITCH)10.5 10.0(BOTH SIDES)
M8 THRU
9.5
CABLE OUT
TRACK LENGTH 29.7560.0(PITCH)
M8 THRU
42.0
M5 THRU
601.0(C10)
51.060.0(PITCH)
241.0(C4)
481.0(C8)
361.0(C6)
121.0(C2)181.0(C3)
D-
CL
TL
A-
B-
0.0
26.0
18.5
26.0
0.0
27.0
27.0
0.0
19.0
125.0126.4133.9139.9148.0 (+2.0 for DX 90BT)
FLEXIBLE CABLE 5.6 FOR POWER
FLEXIBLE CABLE 3.3 FOR HALL
11.0
5.0
52.0
26.6
153.
0
M5 10.0 FOR AIR INPUT
54.0
AIR COOLED COILSTANDARD COIL
(+2.0 for DX 90BT)
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
PAGE 21
M A N U A L S I Z I N G O F L I N E A R S E R V O M O T O R
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
PAGE 22
M A N U A L S I Z I N G O F L I N E A R S E R V O M O T O R
99N
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
DX B Series Linear Motors
PAGE 23
P B A S Y S T E M S L I N E A R M O T O R S I Z E R S O F T WA R E
PBA Systems Motor Sizer Software is available to assist in the calculation and selection. Please contact PBA Systems for more information.
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
For individual motion profile
For multiple motion profiles
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
PAGE 24
M A N U A L S I Z I N G O F D I G I T A L S E R V O D R I V E
K
K
Lpeak
L vpeak
vpeak
K
K
K
K
K
K
max
vmax maxv maximumspeed of
max
from
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
PAGE 25
Connection Diagram for Digital Pulse and Direction Command Control
Connection Diagram for Analog Current Command Control
Note: Please contact PBA Systems for wiring diagrams.
DigitalServoDrive
Motion Control Card( analog current command ) DX/EX/LMS/CVCA
Hall & EncoderFeedback
Motor Power
Voltage
Analog I/P
Auxi
liary
Feed
back
Mai
nFe
edba
ck
TerminalsBoard
BufferedEncoder
Digital I/O
Digital I /O
Main Power
Control PowerCable
SplitterBoard
DigitalServoDrive
Pulse Generating Card DX/EX/LMS/CVCA
Hall & EncoderFeedback
Motor PowerPulseTrain
SplittedEncoder
Auxil
iary
Fe
edba
ck
Main FeedbackDigital I/O
Digital I/OMain Power
Control Power
TerminalsBoard
Cable
C O N N E C T I O N D I A G R A M S
(digital P&D command)
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
DX B Series Linear Motors
PAGE 26
C O N N E C T I O N S F O R M O T O R P H A S E S , H A L L - E F F E C T D E V I C E S & T H E R M O S T A T
Connection for Motor Phases
Motor Phase 1, M1 (Pink and Yellow)
Motor Phase 2, M2 (Blue and Green)
Motor Phase 3, M3 (Black and Brown)
Protective Earth, PE (Yellow)
Connection for Hall-effect Devices
Male D-SUB9 Pins Connector
0Vdc – Pin 5 (Black)
+5Vdc – Pin 4 (Red)
Hc – Pin 3 (Blue)
Hb – Pin 2 (Green)
Ha – Pin 1 (White)
Connection for Thermostat (NC switch & opens at 90°C or 100°C)
The lead wires are found together with the motor lead cables as shown:
• Thermostat is basically a contact switch. • Thermistor (PT100) requires a temperature controller unit OR analog inputs on motion controller to
monitor the temperature feedback. User has to ensure that the thermal protection devices are wired to appropriate electronics to ensure that the motor power cutoff is active when temperature reaches its allowable limit. The temperature in which the thermostat is active is shown as below:
Model Thermal device type Thermostat (NC) opens at DX10B PT100 See Note 1 DX20B PT100 See Note 1 DX30B Thermostat 90°C DX50B Thermostat 90°C DX65B Thermostat 100°C DX90B Thermostat 100°C
Note 1: • Programmable on temperature controller or analog inputs on motion controller. • Monitor cutoff temperature setting should be set to trigger at maximum 120°C to prevent damage to the coil.
Model Thermal device type Thermostat (NC) opens at EX40 PT100 See Note 1 EX60 PT100 See Note 1 EX90 PT100 See Note 1
Lead 1 (Orange)
Lead 2 (Orange/Black)
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
We reserve the right to make technical changes at any time without prior notice
DX B Series Linear Motors
PAGE 27
S A M P L E A P P L I C A T I O N S O F D D L M O T O R S XY Table = HSHP* point-to-point motion for vision inspection system.
• Cross rollers are used with customized moving magnet linear servo motors.
XY Stage = HSHP* point-to-point motion for pick & place system.
• Cross rollers are used with customized hybrid ironless linear servo motors.
• Distributed multi-axis controller is used for Cartesian motion control system.
* HSHP = High Speed High Precision
T-gantry = HSHP* contouring motion for 3D pick & place system.
M A K E S A D I F F E R E N C Ew w w. p b a s y s t e m s . c o m . s g
Catalogue PBA Systems 050713Every care has been taken to ensure the correctness of the information contained in the book but no liability can be accepted for any errors or omissions.Copyright reserved. This book or parts thereof may not be reproduced without our permission.
PBA GROUP
Manufacturing Plants
USA
KOREA
ISRAEL
SWITZERLAND
CHINA
TAIWAN
GERMANY
ITALY
DISTRIBUTORSPBA (S) Pte LtdHeadquartersAddress: PBA Building, 505 Yishun Industrial Park A, Singapore 768733Tel: +(65) 6576-6766Fax: +(65) 6576-6765Email: enquiries@pba.com.sgWebsite: www.pba.com.sg
PBA Solutions Pte LtdAddress: PBA Building, 505 Yishun Industrial Park A, Singapore 768733Tel: +(65) 6576-6776Fax: +(65) 6576-6765Email: enquiry@pbasolutions.comWebsite: www.pbasolutions.com
PBA Systems Pte Ltd (601191)Address: PBA Building, 505 Yishun Industrial Park A, Singapore 768733Tel: +(65) 6576-6767Fax: +(65) 6484-6768Email: sales@pbasystems.com.sgWebsite: www.pbasystems.com.sg
PBA Technology Pte Ltd (QA251)Address: PBA Building, 505 Yishun Industrial Park A, Singapore 768733Tel: +(65) 6576-6760Fax: +(65) 6576-6761Email: enquiry@pbatechnology.comWebsite: www.pbatechnology.com
PBA Spindles Pte LtdAddress: PBA Building, 505 Yishun Industrial Park A, Singapore 768733Tel: +(65) 6576-6778Fax: +(65) 6576-6782Email: sales@pba-spindles.com Website: www.pba-spindles.com
PM-PBA Pte LtdAddress: PBA Building, 505 Yishun Industrial Park A, Singapore 768733Tel: +(65) 6576-6766Fax: +(65) 6576-6765Email: pm-pba@pba.com.sg
SINGAPORE MALAYSIAPBA Industries (M) Sdn BhdAddress: No 12A, Ground Floor Aked Esplanad, Jalan 14/155BBukit JalilKuala Lumpur, Malaysia 57000 Tel: +(60) 03-8993-9101 / 9102 / 9103Fax: +(60) 03-8993-9106Email: malaysia@pbagroup.net
PBA System (M) Sdn BhdAddress: No 12A, Ground Floor Aked Esplanad, Jalan 14/155BBukit JalilKuala Lumpur, Malaysia 57000 Tel: +(60) 03-8993-9105Fax: +(60) 03-8993-9106Email: malaysia@pbagroup.net
PBA Industries (PG) Sdn BhdAddress: 17-2-5, Bayan Point,Medan Kampung Relau,Penang, Malaysia 11900Tel: +(60) 04-6427915 / 6452916Fax: +(60) 04-6447434Email: inquiries@pbaindustries.com.my
PBA Advantech (M) Sdn BhdAddress: No 26 & 28, Jalan PTP 1/4, Taman Perindustrian Tasik Perdana, Puchong, Selangor 47120 Tel: +(60) 03-8993-9101 / 9102 / 9103Email: malaysia@pbagroup.net
PBA (S) Pte LtdPhilippines Rep Office:Address: PBA Building, 505 Yishun Industrial Park A, Singapore 768733Tel: +(65) 6576-6766Fax: +(65) 6576-6765Email: info@pbagroup.netWebsite: www.pbagroup.net
PHILIPPINES
TAIWAN
THAILANDPBA Systems (Thailand) Co., Ltd.Address: 234/118, Asok-Dindaeng Road, Huakwang, Bangkapi, Bangkok, Thailand 10310Tel: +(66) 2-641-4522 / 641-4523Fax: +(66) 2-614-4400 E-mail: support@pbathailand.com
International Magnetics Technology Co., LtdAddress: Nongkhae Industrial Estate10/19 Soi SRDI Moo4,Tambon Kokyae, Amphur Nongkae,Saraburi, Thailand 18230Tel: +(66) 3-637-4024
新加坡商立狄線性馬達有限公司地址: 臺北市民權西路35號6樓之2Address: 6-2 FL No. 35, Min Chuan West Road, Taipei, Taiwan 104Tel: +(886) 2-2599-3558Fax: +(886) 2-2599-3042HP: +(886) 982-090-501 / +(886) 938-030-774 Email: pba.taiwan@pbagroup.net
PBA Systems Pte LtdAddress: Ace Hitech City 2-1504, 775, Gyeongin-Ro, Yeongdeungpo-Gu, Seoul, South KoreaTel: +(82) 2-3439-0070 / 71 / 72 / 73 / 74Fax: +(82) 2-3439-0080Email: hs.cho@pbasystems.com.sg
KOREA
CHINASales Office 销售办事处:立狄线性马达(深圳)有限公司PBA Linear Motor Co. Ltd.宝安42区兴华一路华创达中心商务大厦A栋407-A42 Xinghua Road, HuaChuangDa Central Business Building,Block A, 407-ABaoan District, Shenzhen, China 518000Tel:+(86) 755-216-77507Fax:+(86) 755-216-77506
Representative Office 代表机构:新加坡碧绿威私人有限公司深圳代表处宝安42区兴华一路华创达中心商务大厦A栋407-B42 Xinghua Road, HuaChuangDa Central Business Building,Block A, 407-BBaoan District, Shenzhen, China 518000Tel:+(86) 755-216-77507Fax:+(86) 755-216-77506
Indonesia Rep: Mr. Raya TjendrawasiH/P: +(62) 816-4846-547Email: rayac@cbn.net.id
INDONESIA
INDIA
PBA (India) Engineering Services and Supplies Private LimitedAddress: 503, 5th Floor Shivai Plaza, Marol, Andheri East, Mumbai, India 400 059Tel: +(91) 22-401-58381Fax: +(91) 22-401-58389 Email: pbain@pbatechnology.com