Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0...

Post on 08-Jun-2021

1 views 0 download

Transcript of Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0...

Dryvit’s HDCITM ProgramHigh Durability Continuous Insulation

Overview

1. Over 30 years in Canada2. Dryvit is sustainable3. Dryvit’s HDCITM Program

High Durability Continuous Insulation

4. Durability proven with CCMC/ULC-S7165. Also fire resistance – testing & listing at ITS6. Most thermally efficient to meet energy code 7. Summary

� In your next specification, here’s what to include…� Good performance hinges on…

Chateau Lake Louise

Dryvit is Sustainable…Embodied Energy

National Institute of Standards & Technology – BEES v4.0

Gre

enes

t

Dryvit is Sustainable…CO2 Emissions

National Institute of Standards & Technology – BEES v4.0

Gre

enes

t

Dryvit’s HDCITM Program…High Durability Continuous Insulation

� 20 Year warranty including substrate moisture protection

� Panzer® 20 & Corner� Industry 1st: impact

resistance warranty� Can be specified for

all Outsulation®

� Outsulation Plus� Outsulation MD� Outsulation PD

Dryvit is…Impact Resistant

4.3 6.0 12.0 15.0+4.3 20.5+4.3(ounces/yd 2)

Inch-pounds

Panzer®

Impact Resistance Guide

MESH TYPE MESH WEIGHT RECOMMENDED LOCATIONS

Standard Mesh 4.3 oz/yd 2 Walls in general service (not readily accessible to pedestrians & maintenance)

Standard Plus 6.0 oz/yd 2 Walls in general service and areas with infrequent access to maintenance

Intermediate 12.0 oz/yd 2 Balcony wall areas, or walls with medium maintenance access

Panzer 15 + Standard

Mesh

15.0 oz/yd 2

+ 4.3 oz/yd2Grade level (within 4 - 8 ft.) with light to medium to heavy pedestrian traffic

Panzer 20 + Standard

Mesh

20.5 oz/yd 2

+ 4.3 oz/yd2Heavy duty reinforcing for walls with medium to heavy pedestrian traffic

Panzer 20 + Standard

MeshHDCITM Panzer Corner & Panzer 20 for

100% of walls.

New Construction

Panelization

Panelization

OVERCladding

RECladding

Dryvit has…CCMC Approval

� Registered since 1998…

� Basis for ULC-S716 Standards

� Adopted by NBC and OBC in 2015

Dryvit has…Fire Testing

Outsulation System(Plus/MD/PD)

Nominal EIFS R-Value Estimated Assembly Value

2” EPS 7.6 9.93” EPS 11.4 13.64” EPS 15.2 17.25” EPS 19.0 20.96” EPS 22.8 24.6

Nominal 3-5/8” Steel Stud Wall – ½” Glass Mat Faced S heathing, Interior ½” Drywall, No Stud Cavity Insulation

Dryvit is…The Most Thermally Efficient

SummaryDryvit Outsulation ®

�Smallest carbon footprint…�+30 years history in Canada �CCMC registered since 1998�Fire testing for noncombustible

construction�Aesthetic versatility unlike no other�HDCITM = 20 Year Warranty +

Impact Resistance

HDCITM in your next specification…

� After specifying Outsulation® Plus, MD, or PD, specify Dryvit’s HDCITM , as follows:� “Dryvit HDCI with Panzer 20 and Panzer Corner

are required for 100% of the wall areas.”� “System manufacturer shall provide a 20 year

warranty, including provisions to repair impact damage through the EIFS lamina, and moisture protection of the substrate.”

EASY!

Good Service Life Hinges on…

� Critical details (design):� Panelization = engineered cladding� High impact resistance = HDCITM

� Stain resistance – detail for rain deflection

� Quality control (construction):� Dryvit requires “Contractor Agreements ”

signatory to Dryvit’s specs & details� Dryvit tech -support during construction

� Maintenance (what & when)� DryvitCARE & maintenance guide

Design Flexibility

Dryvit’s HDCITM ProgramHigh Durability Continuous Insulation

1-800-263-3308www.dryvit.ca