Post on 23-Apr-2018
Dräger Zeus® Infinity® EmpoweredAnaesthesia Workstations
The Dräger Zeus® Infinity® Empowered (IE) combines ease of use withinnovative technology. Taking the anaesthesia process well beyondpresent frontiers, the Zeus® IE represents a technological milestonewhich gives you an outstanding system integration and workflow control.The Dräger Zeus® IE lets you concentrate on your patient, not on yourworkstation.
Benefits
02 | Dräger Zeus® Infinity® Empowered
High level of integration
Zeus IE has a pioneering role when it comes to system integration. You can set and monitor via the 20"graphical user interface the ventilation, fresh-gas delivery and agent dosing. The layout can be customised todisplay the optional integrated patient monitoring data and integrated SmartPilot View which calculates thedepth of anaesthesia in a split screen. All the information needed to make decisions is available at a glance,thus helping you to improve workflow efficiency.
Smart support
The Zeus IE offers you assistance and decision-supporting software technologies which can supportyour workflow and help to improve the quality of care. The new optional ventilation assistance systemSmart Ventilation Control (SVC) is a clinical-knowledge based assistance system which adapts ventilationto physiology from intubation until extubation. You just set a clinical target (e.g. Encourage SpontaneousBreathing) and SVC will adjust automatically the ventilation parameters (e.g. inspiratory pressure and breathingfrequency) to achieve the targeted ventilation.
Furthermore, the optionally integrated SmartPilot View, a software to visualise and predict the anaesthesia level,enables you to see instantly the combined effect of volatile agent and opioids. The “what-if function” shows youthe calculated effect of a volatile agent setting even before the setting is confirmed.
Uncompromised ventilation quality
The Zeus IE offers high ventilation quality in the OR on ICU level and can be used for patients of all agesand acuity levels. The innovative blower-driven ventilation technology can provide practically unlimited flow,regardless of ventilation mode. The blower unit TurboVent2 enables spontaneous breathing on both pressurelevels (real BiPAP ventilation). The availabilty of CPAP in Man/Spont mode and active PEEP regulation keepseven the lungs of obese patients and critically ill lungs open.
Enhanced workflow
Functional ergonomics further serve to streamline your workflow. The Zeus IE fits perfectly to almost everyOR layout, as it can be operated from both sides and the monitors can be positioned accordingly. The timer-controlled automatic self-test contributes to overall workflow efficiency. In addition, the Zeus IE can seamlesslytransfer data to IT solutions and Electronic Medical Record Keeping Systems. As data protection becomesmore and more important for the hospitals, the cyber security of Zeus IE is being enhanced with the newsotfware 2.0.
Increased efficiency
The dosing principle of the Zeus IE, Target Controlled Anaesthesia (TCA), aims at maximising efficieny andease of use. Based on the set target concentration of FiO2 and expiratory anaesthetic agent, Zeus IE deliversthe required amount of oxygen and volatile agent. Due to the fact that Zeus IE works as a closed system, no
Benefits
Dräger Zeus® Infinity® Empowered | 03
gas is wasted during wash-in and steady state. That means that Zeus IE delivers exactly the amount of gaswhich is metabolised by the patient. Because it saves gases and anaesthetic agent, the Zeus IE is an efficiencydriver and reduces the amount of greenhouse gases produced by your hospital.
System Components
MT-
3911
-200
8
DIVA
Together with the unique ventilation technology of Zeus® IE, the directinjection volatile agent dosing module DIVA, is the main componentwhich maximizes the efficieny of Target Controlled Anaesthesia. Thefilling level of the DIVA dosing module can be displayed on the Zeus® IEscreen. Filling level alarms remind you to refill the DIVA dosing modulein time.
D-1
9739
-200
9
Infinity® Acute Care System
Transform your clinical workflow with Infinity® Acute Care System. Itsmultiparameter monitor integrates with its networked medical-gradeworkstation, giving you real-time vital signs, access to clinical hospitalsystems and data management applications for a comprehensive rangeof patient information and powerful analysis tools at the point-of-care.
System Components
04 | Dräger Zeus® Infinity® Empowered
D-9
003-
2016
IV Pumps
The Zeus® IE offers ergonomic mounting solutions for intravenousinfusion pumps. The data of the most common types of IV pumps maybe transferred to the integrated SmartPilot® View. Thus, you receivehelpful information about drug dosage and the prediction of anaestheticeffect on your main screen.
D-7
321-
2011
Blower Unit TurboVent2
The blower unit TurboVent2 is the source for the outstanding ventilationperformance of the Zeus® IE. In addition, it can easily be removed fromthe device and without further dismantling it can be autoclaved. Finally,the minimal system volume of the TurboVent2 accelerates the wash-inand wash-out of anaesthetic agent into the breathing system.
Accessories
D-4
2848
-201
2
WaterLock® 2
Perfect protection for precise gas measurement. Dräger WaterLock® 2safely stops water from getting into the multi-gas sensor. The membranetechnology developed by Dräger for the WaterLock® 2 stops anybacteria or germs from getting into the gas measurement system.The WaterLock® 2 is also safe and simple to empty – with a furtheradvantage in handling and hygiene.
Accessories
Dräger Zeus® Infinity® Empowered | 05
MT-
1998
-200
8
Drägersorb® 800+ – Soda Lime
Soda lime is essential for CO2 absorption in inhalation anaesthesiamachines with rebreathing systems.
D-7
156-
2010
Dräger VentStar® Anaesthesia Breathing Circuits
Dräger VentStar® Anaesthesia Breathing circuits are high qualitydisposable hoses for different applications and different patient groups.The breathing circuits are tested and approved with the Zeus® IE toensure the optimal performance of the combination. Due to the factthat the Zeus® IE is able to create a circular flow through the breathinghoses, changes in the gas concentration settings arrives the patientfaster. Therefore, the Zeus® IE makes it possible to use pediatric hosesalso for neonatal patients.
Related Products
MT-
2077
-200
8
Innovian® Solution Suite
Innovian Solution Suite is a web-based IT solution that supports clinicalworkflow across the perioperative and critical care environments. Tightlyintegrated with Dräger monitoring, ventilation and anaesthesia solutions,Innovian simplifies patient documentation, supports clinical decision-making, and provides data access anywhere via the hospital network.
Related Products
06 | Dräger Zeus® Infinity® Empowered
D-3
5833
-201
5
Workplace Infrastructure & Planning
Zeus® IE is also offered as a ceiling variant according to your operatingroom layout. In combination with our expertise in complex processesand our advanced workplace designs, we work with you to develop thebest concept. This way, we can offer tailored, flexible future-orientedsolutions.
Technical Data
Dräger Zeus® Infinity® Empowered | 07
Gas deliveryModes of operation Fresh-gas control, auto control with insp. O2 control
Fresh-gas flow 0.25 – 18 L/min (fresh-gas control);0 – 18 L/min (auto control);closed system mode (uptake)
O2 control 21 – 100% (in fresh-gas control with AIR); Oxygen RatioController
Carrier gases N2O and Air
O2 flush > 35 L/min
O2 safety flow 0 – 12 L/min
Auxiliary O2 flow tube 0 – 16 L/min (e.g. for regional anaesthesia)
External fresh-gas outlet Optional
Anaesthetic agent delivery DIVA (Direct Injection of Volatile Agents)*Mode of operation of DIVA modules Fresh-gas control, auto control with expiratory agent control
(2 plug-in slots for ISO, SEV, DES)Max. filling volume 315 mLDelivery range: Fresh-gas control (fresh-gas settings) ISO: 0 – 5 kPa; SEV: 0 – 8 kPa; DES: 0 – 18 kPaDelivery range: Auto control (expiratory agent settings) ISO: 0 – 2.5 kPa; SEV: 0 – 5 kPa; DES: 0 – 12 kPa
Ventilator “TurboVent 2”Electronically controlled and electrically driven blower, open for spontaneous breathingModes of operation Man/Spon (with availability of CPAP); Volume Control (VC);
VC-Autoflow; Pressure Control (PC); Synchronization for VC-Autoflow and PC; CPAP Pressure Support; Pause
Ventilation assistance system Smart Ventilation Control (SVC) (optional)Tidal volume 20 – 1,500 mL (volume mode)Application range Neonates, children, adultsInspiration pressure Pinsp PEEP – 70 hPaPressure support above PEEP (PSupp) 0 – 70 hPaBreathing frequency 3 – 80 L/minInspiratory time 0.2 – 10 s; (I:E 4:1 – 1:4)Pressure rise time (slope) 0 – 2 sInspiratory flow 0 – 180 L/minPressure limitation Pmax 8 – 70 hPaPEEP / CPAP 0 – 35 hPa / 0 – 10 hPa (Man/Spont)Flow trigger 0.3 – 15 L/minSystem leakage tightness < 100 mL at 20 hPa (automatic measurement in system test)Volume of soda lime canister 1.5 l
MonitoringTouchscreen 20" colour; Display of up to 8 waveforms with mini trends; intelligent alarm management; central alarm display;comprehensive browser-based help system; monitoring of inspiratory and expiratory concentrations of O2, N2O, CO2 as well as volatile
agents; age- and altitude-corrected xMAC value; minute volume, tidal volume, breathing frequency; Peak, Plateau, Mean and PEEPbreathing pressures; compliance and resistance (with trend); MVxCO2-trend
Waveforms of CO2, O2, volatile agents, breathing pressure, inspiratory and expiratory flow or volume; virtual flow tubes; pressure-
volume (PV) or flow-volume (FV) loop; gas and volatile agent consumption actual/summarised; O2 uptake; graphical trend with cursor;
tabular trend with time filter; DIVA filling level; gas supply pressures; battery status
Integrated SmartPilot® View (optional)
Left part of the Zeus IE screen can be configured to display SmartPilot® View. SmartPilot® View calculates and displays the anaesthesiaeffects of volatile and intravenous drugs based on pharmacodynamic and pharmacokinetic models.
Technical Data
08 | Dräger Zeus® Infinity® Empowered
Not all products, features, or services are for sale in all countries.Mentioned Trademarks are only registered in certain countries and not necessarily in the countryin which this material is released. Go to www.draeger.com/trademarks to find the current status.
CORPORATE HEADQUARTERSDrägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, Germanywww.draeger.com
Manufacturer:Drägerwerk AG & Co. KGaAMoislinger Allee 53-5523558 Lübeck, Germany
REGION DACHDrägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 2080info@draeger.com
REGION EUROPEDrägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 2080info@draeger.com
REGION MIDDLE EAST, AFRICADrägerwerk AG & Co. KGaABranch OfficeP.O. Box 505108Dubai, United Arab EmiratesTel +971 4 4294 600Fax +971 4 4294 699contactuae@draeger.com
REGION ASIA PACIFICDraeger Singapore Pte. Ltd.25 International Business Park#04-20/21 German CentreSingapore 609916Tel +65 6308 9400Fax +65 6308 9401asia.pacific@draeger.com
REGION CENTRALAND SOUTH AMERICADräger Panama ComercialS. de R.L.Complejo Business Park,V tower, 10th floorPanama CityTel +507 377 9100Fax +507 377 9130contactcsa@draeger.com
CANADADraeger Medical Canada Inc.2425 Skymark Avenue, Unit 1Mississauga, Ontario, L4W 4Y6Tel +1 905 212 6600Toll-free +1 866 343 2273Fax +1 905 212 6601Canada.support@draeger.com
Locate your Regional SalesRepresentative at:www.draeger.com/contact
90 7
1 24
7 |
16.1
2-2
| H
Q |
PP
| S
ubje
ct to
mod
ifica
tions
| ©
201
6 D
räge
rwer
k AG
& C
o. K
GaA
* not included in standard configuration. They have to be ordered seperately.
Patient monitoring (optional)ECG (6 lead); adjustable Multilead ST-segment analysis incl. alarm; non-invasive blood pressure (single, interval, continuous,venostasis); invasive blood pressure (max. 10 channels); cardiac output incl. haemodynamic calculations; pulse oximetry withplethysmogram; temperature measurement (2x), e.g. TCore; neuro muscular transmission (NMT); anaesthesia effect monitoring (BISx)
GeneralData exchange up to 6 USB portsSerial interface 2 x RS232Ethernet interface (1) For access to hospital network, network printer, or remote
inspectionEthernet interface (2) For access to hospital network printer, or remote inspectionEthernet interface (3) Infinity network connectionPower supply 100 – 240 V, 45 – 65 HzBattery backup Min. 30, typically 90 minutesDimensions (H x W x D) 165 x 110 x 70 cmWeight 185 kg incl. 1 DIVA module