Post on 19-Nov-2021
17501296.06.08.13
Directional control valves DN 10 directly actuatedInterface to DIN 24 340 and ISO 4401 (CETOP03)
PN [pmax.] = 350 bar
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
No dynamic seals
Delay of switching time by exchangeable nozzle
Optional: without manual override
Wet type solenoid with pressure-tight core tube
Easy replacement of solenoids. Solenoids with pressure-tight core tube (tube secured to valve body by means of central thread).
Valves with Viton seals standard
Coils designed for DC voltage. AC operation via connector equipped with rectiier
General parameters
Designation: Directional control valve
Symbol:See type survey or type key
Design: Spool-type valve
Type of mounting: Flange
Line connection: Subplate
Mounting position: Preferably horizontal
Weight of valve with: 1 actuator [kg]: 6.5 2 actuators [kg]: 7.3
Weight of subplat.: G 1/2 [kg]: 2 G 3/4 [kg]: 3.4
Ambient temperature range Ju [°C]:-20 to +50
Size: DN 10
MTTFd [years]:150
Technical dataHydraulic parameters
Operating pressure pemax. [bar]at port P, A, B:up to 350 at port T: up to 210
Pressure luid temperature Ju max. [°C]:+70
Viscosity range: n [mm2/s]:12 to 500
Flow Qmax [l/min]:See characteristic curves
Filtration: Oil purity class to ISO 4406: 18/15
Further parameters
Manual override: Standard
Switching times, approx. [ms]: ton: 70 to 95 toff: 40 to 80
Number of switchings/h, approx.: 15000
Rated voltage connector input UN [V]: Standard voltages: VH 10 VH11 (VH 13) (VH 12) 24 DC 230 AC 40...60 Hz +5%/-10% +5%/-10%
Further voltages: VH10 VH11* 12 DC 24 DC 48 DC 98 DC 110 AC 110 DC 125 DC 185 DC 205 DC 230 AC 220 DC 230 DC
* via connector rectiier
Power consumption P20 [W]: 42
Duty cycle [%]:100
Degree of protection for solenoid and electrical connection to DIN 40050: IP 65
2
Directional control valves DN 10
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501296.06.08.13
Type survey (standard versions)
Symbol Symbol-No. Overlap Voltage Type Cat. No.
0011) + VDC24V
VAC230
S10VH10 G 001 001 5 O VS10VH13 G 001 001 5 O V
S10VH11 G 001 001 5 O VS10VH12 G 001 001 5 O V
5204867.7908.024005204956.7908.02400
5204941.7908.205005205522.7908.20500
003 - VDC24V
VAC230
S10VH10 G 003 001 5 O VS10VH13 G 003 001 5 O V
S10VH11 G 003 001 5 O VS10VH12 G 003 001 5 O V
5204869.7908.024005205414.7908.02400
5204940.7908.205005205578.7908.20500
020 + VDC24V
VAC230
S10VH10 G 020 001 5 O VS10VH13 G 020 001 5 O V
S10VH11 G 020 001 5 O VS10VH12 G 020 001 5 O V
5204820.7908.024005204957.7908.02400
5204961.7908.205005205391.7908.20500
019 + VDC24V
VAC230
S10VH10 G 019 001 5 M V S10VH13 G 019 001 5 M V
S10VH11 G 019 001 5 M VS10VH12 G 019 001 5 M V
5204963.7908.024005205349.7908.02400
5204964.7908.205005205412.7908.20500
008 + VDC24V
VAC230
S10VH10 G 008 001 5 O VS10VH13 G 008 001 5 O VS10VH11 G 008 001 5 O VS10VH12 G 008 001 5 O V
5204819.7908.024005204958.7908.02400
5204962.7908.205005205368.7908.20500
009 + VDC24V
VAC230
S10VH10 G 009 001 5 O VS10VH13 G 009 001 5 O V
S10VH11 G 009 001 5 O VS10VH12 G 009 001 5 O V
5204927.7908.02400 5204959.7908.02400
5204943.7908.205005205389.7908.20500
013 - VDC24V
VAC230
S10VH10 G 013 001 5 O VS10VH13 G 013 001 5 O V
S10VH11 G 013 001 5 O VS10VH12 G 013 001 5 O V
5204933.7908.024005204960.7908.02400
5204949.7908.20500 5205390.7908.20500
1) Port T of these 3/2 directional control valves is used as leak oil connection.
Connecting plate
Typ Best.-Nr.
G 1/2 P S 10 G 4 001 2 O O 1065184
G 3/4 P S 10 G 5 001 2 O O 1065185
Ordering
The units are designated by their type number. The composition of this number can be drawn from the type code. The standard ver- sions are listed in the type survey. When ordering any of the stan- dard versions, please state type number as well as catalog number to preclude possible misinterpretations.Further valve versions can be composed via combination of types - order numbers on request.
Flanged valves are provided with O-rings and connector. Subplate and mounting screws must be ordered separately.
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501296.06.08.13 3
Directional control valves DN 10
Type key
Directional control valve
S 10 ... ... G ... 001 5 ... ...
1 2 3 4 5 6
1 Actuation: V – Without manual override VH – With manual override
2 Electrical 10 – Connector Pg 11 connection: 11 – Connector Pg 11
with rectiier insert on plug 12 – Connector Pg 11
with rectiier insert and function indicator on plug
13 – Connector Pg 11 with function indicator on plug
3 Symbol: – Standard symbols see page 2 – Extra symbols see below
5 Additional data: O – Standard design M1) – Mechanical detent C2) – Switching delay by means of nozzle
6 Sealing material: V – FKM (e.g. Viton)
3 Symbol:
Subplate
P S 10 G ... 001 2 O O
1
1 Line connection: 4 – G 1/2 (internal thread 5 – G 3/4 to DIN ISO 228/1)
1) Only 2-position valves are available with detent.2) Port T of valves with a delayed switching time has to be pressurized with
approx. 5 bar.3) Port T of these 3/2-way valves is to be used as leak oil connection.
Extrasymbols
Symbol No.
Overlap Extrasymbols
Symbol No.
Overlap Extrasymbols
Symbol No.
Overlap
002 - 016 - 086 +
087 - 023 - 088 +
004 + 025 + 097 +
005 + 031 3) - 231 -
094 + 033 - 146 -
010 + 038 + 153 -
007 + 039 + 183 +
011 - 043 + 198 +
153 - 044 3) - 223 +
090 - 045 - 188 -
017
Further symbols on request!
4
Directional control valves DN 10
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501296.06.08.13
Ordering example
Directional control valve:Type No.:S 10 VH 10 G 001 001 5 O VCat. No.:5204867.7908.024.00
Wanted: 4/3 directional control valve DN 10, 24 VDC, solenoid with plug, symbol 001, along with corresponding subplate G 1/2.
Subplate:Type No.:P S 10 G 4 001 2 O OCat. No.:1065184
Mounting screws:(4 pcs. required) Socket-head screw:(M 6 x 60 DIN 912-10.9)Cat. No.:0700416
Design Actuation Mounting Line connection
The directional control valves are electromagnetically operated, with spring return for the standard valves. The piston of valves with mechanical detent remains in energized position even if de-energized.
The design is based upon the 5-chamber system. A spool of hardened steel slides in a housing made of high- strength cast-iron. Therefore the units are suitable for rough operating conditions and guarantee reliable switching, even with long rest periods.
The units are bolted on sub- plates and sealed by O-rings.
Subplate, interface to DIN 24340-A10 and ISO 4401-AC-05-4-A (CETOP05).
Dimensional drawings
Directional control valve
S 10 V ...S 10 VH ...
Interface S10 to DIN 24340-A10 and ISO 4401
Surface of counterpart Rz max. 4
Coil rotatable by 90°
Tightening torquemax. 6 Nm
4/3-directional control valve
SW 27 tightening torque max. 50 Nm
Manual override only S10 VH ...
Connector 10, 11, 12 and 13
solenoid “a”
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501296.06.08.13 5
Directional control valves DN 10
Dimensional drawings
Directional control valve
S 10 V ... M ...S 10 VH ... M ...
Subplate with interface according to DIN 24 340-A 10 and ISO 4401-AC-05-4-A
G 1/2
G 3/4
solenoid “a” solenoid “b”
Aperture for connection in control panel Position: centrical to plate
Aperture for connection in control panel
6
Directional control valves DN 10
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501296.06.08.13
Characteristic curves
Flow curves Q = f(∆p)
Symbol P-A P-B A-T B-T P-T
001 6 6 - - -
003 6 6 4 4 -
008 6 6 5 5 -
009 6 6 3 3 -
013 4 4 3 2 1
019 6 6 4 4 -
020 6 6 4 4 -
Flow direction
Power limits
Symbol Characteristic curve
001 1
003 4
008 5
009 2
013 3
019 5
020 5
Maximum values determined with solenoid in warmed-up condition and at an undervoltage of 10%.Fluid passing in two directions (from P to A and B to T).If one port is closed, a reduced breaking capacity must be taken into consideration.A reduced breaking capacity must also be taken into consideration for valve types with switching delay (nozzle).
J = 50oC
υ = 28 mm2/s
J = 50oC
υ = 28 mm2/s
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501296.06.08.13 7
Directional control valves DN 10
Spare parts drawings
S 10 V ... S 10 VH ...
S 10 V ... MS 10 VH ... M
with mechanical detent
S 10 V ... C ...S 10 VH ... C ...
Switching time delay with nozzle
Spare parts kit
0618648, containing:5 x O-ring (FKM 80) ref. 0701623 (part 1)2 x O-ring (NBR 70) ref. 0656606 (part 2)2 x O-ring (NBR 70) ref. 0701266 (part 3)
Sealings are exclusively available as spare parts kit.
Repairs and maintenance must only be carried out by the valve manufacturer or authorized personnel.
for 4/3 - directional valve
8
Directional control valves DN 10
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501296.06.08.13
Electrical spare parts
Electrical connection, Symbol 10 Cat. No.
Connector Pg 11 (Operating voltage: 0...300 V DC)
0570275
Electrical connection, Symbol 11 Cat. No.
Connector Pg 11 with rectiier (Operating voltages: 15...250 V AC or10...250 V DC)
0570819
Electrical connection, Symbol 12 Cat. No.
Connector Pg 11 with rectiier and indicator (Operating voltages: 80...130 VAC or 100...130 V DC)
Connector Pg 11 with rectiier and indicator (Operating voltages: 150...250 V AC or 135...250 V DC)
0588568
0571502
Electrical connection, Symbol 13 Cat. No.
Connector Pg 11 with indicator (Operating voltages: 24 V DC)
Connector Pg 11 with indicator (Operating voltages: 90...130 V DC)
Connector Pg 11 with indicator (Operating voltages: 150...250 V DC)
0570818
0570816
0570817
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501296.06.08.13 9
Directional control valves DN 10
HERION Systemtechnik GmbHUntere Talstraße 6571263 Weil der StadtTel.: +49 (0) 7033/3018-0Fax: +49 (0) 7033/3018-10info@herion-systemtechnik.dewww.herion-systemtechnik.de
A subsidiary of the Norgren and IMI group of companies
Distribution and Service
• in 75 countries through the Norgren service network
HERION SystemtechnikSales Partners
ChinaESTUN INDUSTRIAL AUTOMATION CO., LTS155,Jiangjun Road, Jiangning Economical & TechnicalDevelopment Zone, Nanjing, 211100 P.R.C.Tel.: +86-25-52785915E-Mail: info@estun.comwww.estun.com
JapanRiken Optech Corporation2-6-9, Higashi Ohi, Shinagawa-ku,Tokyo 140-8533Tel.: +81 3 34748602E-Mail: contact@rikenoptech.comwww.rikenoptech.com
KoreaCHUNGWOO CO., LTD.# 416-4 DokjeongriJanganmyun HwaseongsiKyungkido, KoreaTel.: +82 (0)31 351-5340E-Mail: blueox2@unitel.co.krwww.chungwooco.co.kr
SpainEUROTECH SYSTEMS, S.L.Av. Can LLuch, 2508690 SANTA COLOMA DE CERVELLOTel: +34 93 634 0101E-Mail: eurotech@eurotechsys.comwww.eurotechsys.com
South AfricaErnest Lowe ELCOPneumatic & Hydraulic Automation Solutions6, Skew Road, Boksburg North 1459,Gauteng, South AfricaTel.: +27 (11) 898-6600E-Mail: corporate@elco.co.zawww.elco.co.za
TaiwanFull Life Trading Co., Ltd.16F-4, No.2, Jian Ba Rd. Chung Ho CityTaipei County, Taiwan 23562Tel.: +886-2-82261860E-Mail: sales-dept@fulllifetrading.comwww.fulllifetrading.com
TurkeyPower Pnomatik Proses A. SNecatibey Cad. No:44/2KaraköyÝstanbul 34420Tel.: +90 212 2938870E-Mail: info@powerpnomatik.comwww.powerpnomatik.com
Directional Control Valve
NG10 offering a range of
actuation modes
Direct control
Mounting plate with hole patterns to DIN 24 340 and ISO 4401 7503313.06.06.09
DesignThe control valve is constructed according to the5-chamber system and is designed to operate as agate valve. The hardened steel pistons are housed ina high-strength cast iron hydraulic unit. This allows theequipment to be deployed in tough operating condi-tions.
Actuation modesThe directional control valves can be operated hydrauli-cally, pneumatically, mechanically or by spring action,as required
MountingThe equipment is clamped to a mounting plate. Thehydraulic seals are provided by O-rings.
Network connectionMounting plate with hole patterns to DIN 24 340-A10and ISO 4401-AC-05-4-A.
Description (standard unit)
Classification
Directional control valve
1 mode of actuation: N – pneumatic 1)
Y – hydraulicR – roller tappet actuatedH – manually actuated
2 Electricalconnections: 00 – actuation without
electrical connection
3 Symbols: See equipmentspecifications
4 Runner: 001 – Standard design
5 Design class: 5 – centrally-clamped
6 Additional data: O – standard model
M – mechanical lockingmechanism
7 Seal material: V – FKM (e.g. Viton)1) Units with electro-pneumatic actuation can be provided on request.
• Excellent piston guidance (5-chamber design)providing trouble-free operation even where the unit isinactive for long periods.
• Valves normally fitted with Viton seals
Main features
HERION Systemtechnik GmbHUntere Talstraße 65
71263 Weil der Stadt (Merklingen)
Tel.: +49 (0) 70 33/30 18-0
Fax: +49 (0) 70 33/30 18-10
www.herion-systemtechnik.de
info@herion-systemtechnik.de
Subplate
P S 10 G ... 001 ... O O
1 2
S 10 ... ... G ... ... ... ...
1 2 3 4,5 6 7
1 Networkconnections: 400 - G 1/2 (internal threads
500 - G 3/4 to DIN ISO228/1)
3 Design class: 200
Notes:
1. on 2-way valves, mechanical locking is available for
all modes of actuation except roller tappet (R)
2. on 3-way valves, mechanical locking is only available
on manually-actuated units
Typ designation N 00 Y 00 R 00 H 00
General specifications
Unit designation Directional control valve
Symbol See equipment specification
Model type Gate valve
Type of mounting Flange
Network connections Mounting plate
Mounting position Preferably horizontal
Unit mass 1 type of operation [kg] 6.1 6.1 6.5 6.8
2 type of operation 6.5 6.5 - -
Mass of associated parts G 1/2 [kg] 2
G 3/4 3.4
Environmental temperature
range ϑu [°C] -20 to +50
Nominal diameter NG 10
Hydraulic specifications
Operating pressure range pe max. [bar]
at ports P, A, B to 315
at port T to 100 to 160 to 10 to 160
Hydraulic fluid temperature ϑm max. [°C] +70
Viscosity range ν [mm2/s] 12 to 500
Flow rate Qmax. [l/min] See characteristic curves 140 140
Filtration Oil cleanliness standard to ISO 4406: 18/15
Additional specifications
Manual auxiliary operation none -
Control pressure range pst [bar] 41) to 10 5 to 315 -
Control volume Vst [cm3] 5 1.2 -
Switching time ca. [ms] Dependent on Dependent on Dependent on -
te air flow air flow oil flow
ta
Actuating force Fb [N] - 270 35
2 7503313.06.06.09Subject to alteration
Specifications according to VDI 3267
1) min. Control pressure, pst 2.5 bar with zero pressure at port T
37503313.06.06.09 Subject to alteration
Flow rates Qmax for pneumatic and hydraulic actuation
Flow curves
Symbol
001
003
008
009
011
013
019
020
038
6
1
1
1
1
3
1
1
1
6
1
1
1
1
3
1
1
1
-
3
5
4
3
2
3
3
3
-
3
5
4
3
7
3
3
3
-
-
-
-
2 1)
8
-
-
-
Flow direction
P-A P-B A-T B-T P-T
Symbol Characteristic curves
001
003
008
009
011
013
019
020
038
2
4
1
3
4
5
1
1
1
The valve can be operated in two directions(P-A and B-T).Switching performance will be reduced where portsare blocked (additional data on symbol switchingperformance available on request).
Ordering Sample Order
The units are distinguished by a classification system.The designation of each classification group is shown inthe key. Standard models are described in the equip-ment specifications. The order number should be givenin addition to the classification number when orderingstandard models. Classification groups can be combi-ned to allow additional equipment designs to be provi-ded. These units are assigned an order number by thefactory, which is stated in the order confirmation docu-ment. O-rings are included in orders for units with connectingflanges.Mounting plates and attachment screws must beordered separately
4/3 way directional control valve NG 10, with manualoperation and mechanical locking, symbol 008 andassociated mounting plate G 1 /2
Directional control valve:Classification: S 10 H 00 G 008 001 5 M VOrder number: 5205051
Mounting plate:Classification: P S 10 G 4 001 2 O OOrder number: 1065184
Attachment screws: (for 4 attachment points)Zylinderschraube: (M 6 x 60 DIN 912-10.9)Order number: 0700416
Performance thresholds
1) 1)Direction of flow is P-A-B-T when Symbol 011 is in Position 0.
4 7503313.06.06.09Subject to alteration
Equipment specification (standard unit specification)
1) T ports on 3/2 directional control valves must be used as the oil overflow connection.Note: further symbol specifications are available on request.
Symbol Mode ofactuation
Switchover
SymbolNo
Network connections Classification Order No
Valve
0011)
003
020
019
009
008
013
011
020
019
009
011
+
-
+
+
+
+
-
-
+
+
+
-
pneu-matic
Hydraulic
S 10 N 00 G 001 001 5 O V
S 10 N 00 G 003 001 5 O V
S 10 N 00 G 020 001 5 O V
S 10 N 00 G 019 001 5 M V
S 10 N 00 G 009 001 5 O V
S 10 N 00 G 008 001 5 O V
S 10 N 00 G 013 001 5 O V
S 10 N 00 G 011 001 5 O V
S 10 Y 00 G 020 001 5 O V
S 10 Y 00 G 019 001 5 M V
S 10 Y 00 G 009 001 5 O V
S 10 Y 00 G 011 001 5 O V
5205178
5205119
5205073
5205072
5205120
5205250
5205231
5205151
5205060
5205067
5205212
5205061
Mounting plate G 1/2P S 10 G 4 001 2 O OOrder number:1065184
Mounting plate G 3/4P S 10 G 5 001 2 O OOrder number:1065185
Mounting plate G 1/2P S 10 G 4 001 2 O OOrder number:1065184
Mounting plate G 3/4P S 10 G 5 001 2 O OOrder number:1065185
0011)
005
020
+
+
+
Rollertappetactuated
S 10 R 00 G 001 001 5 O V
S 10 R 00 G 005 001 5 O V
S 10 R 00 G 020 001 5 O V
5205081
5205284
5205247
Mounting plateG 1/2P S 10 G 4 001 2 O OOrder number:1065184
Mounting plate G 3/4P S 10 G 5 001 2 O OOrder number:1065185
57503313.06.06.09 Subject to alteration
Equipment specification (standard unit specification)
Symbol Mode ofactuation
Switch-over
SymbolNo.
Network connections Classification Order No..
Valve
0011)
020
008
009
013
019
008
009
025
+
+
+
+
-
+
+
+
+
Manually-actuated
S 10 H 00 G 001 001 5 O V
S 10 H 00 G 020 001 5 O V
S 10 H 00 G 008 001 5 O V
S 10 H 00 G 009 001 5 O V
S 10 H 00 G 013 001 5 O V
S 10 H 00 G 019 001 5 M V
S 10 H 00 G 008 001 5 M V
S 10 H 00 G 009 001 5 M V
S 10 H 00 G 025 001 5 M V
5205322
5205047
5205048
5205199
5205049
5205050
5205051
5205290
5205280
Mounting plate G 1/2P S 10 G 4 001 2 O OOrder number:1065184
Mounting plate G 3/4P S 6 G 5 001 2 O OOrder number:1065185
6 7503313.06.06.09Subject to alteration
Directional control valves scale diagrams
S 10 N 00 G
S 10 N 00 G ... Mwith mechanical locking mechanism
connection for
plastic pipe hole pattern to DIN2434 – A10
and ISO 4401
for 4/3 way valve
surface of mating part
Rz max. 4
for 4/3 way valve
77503313.06.06.09 Subject to alteration
Directional control valves scale diagrams
S 10 Y 00 G ...
S 10 Y 00 G ... Mwith mechanical locking mechanism
hole pattern to DIN2434 – A10
and ISO 4401
for 4/3 way valve
surface of mating part
Rz max. 4
for 4/3 way valve
8 7503313.06.06.09Subject to alteration
Directional control valves scale diagrams
S 10 R 00 G ...
hole pattern to DIN2434 – A10
and ISO 4401
4 working stroke
3 overstroke (no working stroke)
roller rotatable
through 90 degrees
surface of mating part
Rz max. 4
97503313.06.06.09 Subject to alteration
Directional control valves scale diagrams
S 10 H 00 G ...
hole pattern to DIN2434 – A10
and ISO 4401
surface of mating part
Rz max. 4
10 7503313.06.06.09Subject to alteration
Dimensional diagrams with mounting plates – hole patterns to DIN 24 340-A 10and ISO 4401-AC-05-4-A
G 1/2
G 3/4
recess in wall, position:
centered on plate
recess in wall
117503313.06.06.09 Subject to alteration
Replacement part diagrams
S 10 N 00 G ...4/2 and 3/2-Way
S 10 N 00 G ... M ...with mechanical lockingmechanism
S 10 Y 00 G ...4/2 and 3/2-Way
S 10 Y 00 G ... M ...with mechanical lockingmechanism
air bleed screw
air bleed screw
for 4/3 way valve
for 4/3 way valve
12 7503313.06.06.09Subject to alteration
S 10 H 00 G ...4/2 and 3/2-Way
S 10 H 00 G ... Mwith mechanicallocking mechanism
S 10 R 00 G ...4/2 and 3/2-Way
Replacement part diagrams
137503313.06.06.09 Subject to alteration
Replacement parts (unit)
No
1
2
3
4
5
6
7
8
8
9
10
11
12
O-ring (12.4 x 1.8)
O-ring (23.5 x 2.6)
Sealing ring (5.7 x 9 x 1)
Lip ring (6 x 12 x 4.2)
Lip ring (32 x 24 x 7)
Cord (3 x 90)
Ball 5
Detent spring
Detent spring
Wiping seal (20 x 28 x 7)
O-ring (39.4 x 2.6)
O-ring (12.4 x 2.6)
Locking screw
5
2
1
1 and 2
1 and 2
1 and 2
-
-
-
-
-
-
-
5
3
1
2
2
2
2
-
1
-
-
-
-
5
2
1
-
-
-
-
-
-
-
1 and 2
-
-
5
3
1
-
-
-
2
-
1
-
2
-
-
5
2
1
1
-
-
-
-
-
1
-
-
-
5
2
1
-
-
-
-
-
-
-
-
2
1
5
2
1
-
-
-
1
1
-
-
-
2
1
0701623
0701650
0660227
0655332
0663875
0655529
0700753
0616017
0616354
0656005
0701660
0701288
0663875
S 10 H 00 G ... M
mech. locking
S 6 H 00 G ...S 10 R 00 G ...S 10 Y 00 G ... M
mech. locking
S 10 Y 00 G ...S 10 N 00 G ... M
mech. locking
S 10 N 00 G ... Order No.Part description
1 set of consumables: 1, 2, 3, 4and 5
1, 2, 3, 4and 5
1, 2, 3and 10
1, 2, 3and 10
1, 2, 3, 4and 9
1, 2, 3, 11and 12
1, 2, 3, 11and 12
-
Replacement parts range
- Cylinder-head screws(M 6 x 60 DIN 912-10.9)
4 4 4 4 4 4 4 0700416
Mounting screws (valve units) tightening torque MA = 13 Nm
17501297.06.11.12
Directional control valves DN 10 directly actuatedwith switching position monitoring
Interface to DIN 24 340 and ISO 4401
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
General parameters
Designation: Directional control valve
Symbol:See type survey
Design: Spool-type valve
Type of mounting: Flange
Line connection: Subplate
Mounting position: Preferably horizontal
Weight of valve with: 1 actuator [kg]: 7.2 2 actuators [kg]: 8.8
Weight of subplat.: G 1/2 [kg]: 2 G 3/4 [kg]: 2.7
Ambient temperature range Ju [°C]:-20 to +50
Size: DN 10
Technical dataHydraulic parameters
Operating pressure pemax. [bar]at port P, A, B:up to 350 at port T (without leakage port): up to 100
at port T: (with leakage port): up to 350
Pressure luid temperature Ju max. [°C]:+70
Viscosity range: n [mm2/s]:12 to 500
Flow Qmax [l/min]:See characteristic curves
Filtration: Oil purity class to ISO 4406: 18/15
Further parameters
PIN assignment for Tuchel-connection:
Valve with 1 solenoid:Solenoid ”a“ at 1 and 2 or Solenoid ”b“ at 3 and 4 Ground wire at
Valve with 2 solenoids:Solenoid ”a“ at 1 and 2 Solenoid ”b“ at 3 and 4 Ground wire at
Switching times t approx. [ms]: ton: 70 ... 95 1) toff: 70 ... 80 1)
(measured at 315 bar, 60 l/min)
Rated voltage UN [V]: Standard voltages: 24 DC ±10% (Further voltages on request)
Power consumption P20 [W]: 36
Duty cycle [%]:100
Degree of protection for solenoid and electrical connection to DIN 40050:IP 54
Maunal override: at type G: yes at type B: no
1) on request
Valves with Viton seals standard
Leakage port on request
Via drain of leakage oil into spring space (additional hole in housing and subplate is needed - not included in international standard subplate) the port T can be pressurized up to p
max, what leads to a
larger range of application.
Signiicantly improved piston guiding through 5-chamber system.This means reliable switching even with long rest periods as well as long service life.
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501297.06.11.122
Directional control valves DN 10
Symbol Symbol- N0.
Code Overlap Dimensional drawing
Electrical connection (solenoid)
Type Cat No.
0015) 039 + 01 No. 10 Connector (Pg 11) to DIN 43650 on solenoid
S10G10 G 001 039 5 O VS10B10 G 001 039 5 O V
5205219.7623.024005205379.7624.02400
003 039 + 01 No. 10 Connector (Pg 11) to DIN 43650 on solenoid
S10G10 G 003 039 5 O V 5205236.7623.02400
020 039 + 01 No. 10 Connector (Pg 11) to DIN 43650 on solenoid
S10G10 G 020 039 5 O VS10B10 G 020 039 5 O V
5205118.7623.024005205210.7624.02400
008 061 + 02 No 56 Connector (Tuchel) at connection box
S10G56 G 008 061 5 O V 5204988.9000.02400 2)
009 061 + 02 No 56 Connector (Tuchel) at connection box
S10G56 G 009 061 5 O V 5204989.9000.02400 2)
013 061 - 02 No 56 Connector (Tuchel) at connection box
S10G56 G 013 061 5 O V S10B56 G 013 061 5 O V
5204990.9000.02400 2)
5204991.9000.02400 3)
020 061 + 05 Electrical connection 51 S10G51 G 020 061 5 O V 5205258.7637.02400
019 061 + 05 Electrical connection 51 S10G51 G 019 061 5 O V 5205126.9000.02400 2)
001 5) 066 + 03 No 56 Connector (Tuchel) at connection box
S10G56 G 001 066 5 O V 5205101.7639.02400
003 066 - 03 No 56 Connector (Tuchel) at connection box
S10G56 G 003 066 5 O V 5205121.7639.02400
020 066 + 03 No 56 Connector (Tuchel) at connection box
S10G56 G 020 066 5 O V 5205192.7639.02400
019 066 + 04 No 56 Connector (Tuchel) at connection box
S10G56 G 019 066 5 M V 5204987.9000.02400 4)
1) For other symbols, see Publication 75032972) Solenoid-Cat.- No. 9000 means: Solenoid a = 7637, Solenoid b = 76013) Solenoid-Cat.- No. 9000 means: Solenoid a = 7638, Solenoid b = 7605
Ordering
The units are designated by their type number. The composition of this number can be drawn from the type code. The standard ver- sions are listed in the type survey. When ordering any of the stan- dard versions, please state type number as well as catalog number to preclude possible misinterpretations.Further valve versions can be composed via combination of types - order numbers on request.
Flanged valves are provided with O-rings. Subplate and mounting screws must be ordered separately.
Type survey (standard versions)
- Voltage VDC- Line connection: subplate G 1/2, P S 10 G 4 001 2 O O, Cat No. 1065184
subplate G 3/4, P S 10 G 5 001 2 O O, Cat No. 1065185- Actuation: solenoid-actuated, dry op. system
4) Solenoid-Cat.- No. 9000 means: Solenoid a = 7639, Solenoid b = 76015) Port T of this 3/2 directional control valves is used as leak oil connection..
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501297.06.11.12 3
Directional control valves DN 10
Type key
Directional control valve
S 10 ... ... G ... ... ... ... ...
1 2 3 4 5 6 7
1 Actuation: G – DC solenoid (with dry operation system) with manual override
B – DC solenoid (with dry operation system) without manual override
2 Electrical connection:
3 Symbol: 020 – See type survey
4 Code: Mechanical end switch 039 – Position monitoring of switching
position directly at spool, 1 end switch.
Electrical connection: Connector, number of pins: 6 + PE
061 – Position monitoring of 3 switching positions at the solenoid, 3 end switches.
Electrical connection: Harting-connector R 15
066 – Position monitoring of 2 switching positions at the
solenoid, 2 end switches. Electrical connection: Connector
5 Engineering version: 5
6 Additional data: O – Standard design M – Mechanical detent
7 Sealing material: V – FKM (e.g. Viton)
Subplate
1 Line connection: 4 – G 1/2 (Internal thread 5 – G 3/4 to DIN ISO 228/1)
2 Code: 001 – Standard design
3 Engineering version: 2
P S 10 G ... ... ... ... O O
1 2 3
Actuation Code No. Description
G, B 10 Connector Pg 11 to DIN 43 650 on solenoid
G, B 51 Connector in connector box
G, B 56 Connector (Tuchel) in connection box
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501297.06.11.124
Directional control valves DN 10
Electrical parameters and pin-plan (inductive proximity switches)
Isolation: Group ”C“ according to VDE 0110
Nominal voltage ~[V]: 250
Continuous current [A]: 6
Contact system: Dual-circuit directional contact with 2 galvanical and thermical separated contact bridges
Switching system: Snap system with friction contacts
Switching force [N] max.: 4,4
Reset force [N] min.:1,3
Duration of bounce(at 10 mm/min contact velocity) [ms]:≤ 1,5Circuit time (at 10 mm/min contact velocity) [ms]:≤ 10
Number of switching max. switching/min: 300mechanical at 1,6 switchings/s: › 50 million switching cycles (VDE 0660 E3)electrical: dependance on load cycles/min
Reproduceability of switching point [μm]: ± 2
Allowable ambient temperature t [oC]: -30 ... +90
Contact material: Fine silver, system gold plated
Contact arrangement normally closed contact: 1 + 2normally open contact: 3 + 4
Code 039Precision switch according to DIN 43 695
Dimensional drawing Pin plan (Hirschmann connector)
Type: VCS
Directional contact: single line
Reset force [N] max: 1.1
Switching force [N] max: 3.3
Allowable ambient temperature t [oC]: -20 ... +85
DC =: Resistive load: 124 V 6 A 125 V 0,5 A 250 V 0,25 A
Inductive load: 124 V 6 A 125 V 0,07 A 250 V 0,03 A
AC ~: Resistive load: 125 V 10 A 250 V 10 A
Inductive load: 124 V 6 A 125 V 0,07 A 250 V 0,03 A
Code 061 and 066Micro switch(mechanical end switch according to DIN 41 635)
Switching performance
Dimensional drawing
1 = common2 = normally closed3 = normally open
Pin plan (switch with Harting-connector R15)Code 061Valve with 3 switching positions 0570722
Pin plan (Hirschmann connector)Code 066Valve with 2 switching positions 0660690
6
5 43
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501297.06.11.12 5
Directional control valves DN 10
Ordering example
Directional control valve::Type No.:S 10 G 10 G 020 039 5 O VCat. No.:5205118.7623.02400
Wanted:4/2 directional control valve DN 10, 24 VDC, connector on solenoid, Symbol 020, along with corresponding subplate.
Subplate:Type No.:P S 10 G 4 001 2 O OCat. No.:1065184
Mounting screws:(4 pcs. required)Socket-head screw:(M 6 x 60 DIN 912-10.9)Cat. No.:0700416
Design Actuation Mounting Line connection
The directional control vlaves are actuated electromagnetically and by means of a spring or operated by hand lever.
These directional control valves are based on the 5-chamber system, and are designed in the form of spool valves. A spool of hardened steel slides in an housing made of high-strength cast iron. Therefore the units are suitable for rough operating conditions. Depending on the design of the device the end switching position of the spool is monitored via inductive or mechanical proximity switches.
The units are bolted on subplates and sealed by O-rings.
Subplate, interface to DIN 24340-A10 and ISO 4401-AC-05-4-A.
Dimensional drawings
01 Code 039: S 10 G, S 10 B, 3/2- and 4/2-directional control valve
03 Code 066: S 10 G, 3/2- and 4/2-directional control valve
02 Code 061: S 10 G, S 10 B, 4/3-directional control valve
04 Code 066: S 10 G with mechanical detent, 4/2-directional control valve
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501297.06.11.126
Directional control valves DN 10
Subplate G 1/2 with hole pattern according to DIN 24 340-A 10 and ISO 4401-AC-05-4-A
Dimensional drawings
05 Code 061: S 10 G, 3/2- and. 4/2-directional control valve 06 Code 061: S 10 G, S 10 B, 4/3-directional control valve
Subplate G 3/4 with hole pattern according to DIN 24 340-A 10 and ISO 4401-AC-05-4-A
Aperture for connection in control panel concentrically position
Aperture for connection in control panel
ca. 369
124
~197
118 ~1
37
197
124
286.9
118
261.
3
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501297.06.11.12 7
Directional control valves DN 10
Characteristic curves
Flow curves Q = f(∆p)
Symbol P-A P-B A-T B-T P-T
001 6 6 - - -
003 1 1 3 3 -
008, 004, 094 1 1 5 5 -
013 3 3 2 7 8
019 1 1 3 3 -
020, 039 1 1 3 3 -
Flow direction
Power limits Qmax:
Symbol Characteristic curve
001 2
003 4
008, 004, 094, 019 1
013, 0220, 039 5
J = 50oC
υ = 28 mm2/s
J = 50oC
υ = 28 mm2/s
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501297.06.11.128
Directional control valves DN 10
Spare parts drawings
Spare parts kit
0701623, containing:5 x O-ring (12,42 x 1,78)
Sealings are exclusively available as spare parts kit.
Repairs and maintenance must only be carried out by the valve manufacturer or authorized personnel.
Electrical spare parts
Electrical connection 10 Cat. No.
Plugform B (black)
0570275
e.g. on solenoid 7637 or 7638 Cat. No.
Connector compl.Number of pins: 7 + PE
0570722
Electrical connection 51 Cat. No.
Connector compl.Number of pins: 7 + PE
0571057
Electrical connection 56 Cat. No.
ConnectorNumber of pins: 6 + PE
Female connectorNumber of pins: 6 + PE
0660690
0660689
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501297.06.11.12 9
Directional control valves DN 10
HERION Systemtechnik GmbHUntere Talstraße 6571263 Weil der StadtTel.: +49 (0) 7033/3018-0Fax: +49 (0) 7033/3018-10info@herion-systemtechnik.dewww.herion-systemtechnik.de
A subsidiary of the Norgren and IMI group of companies
Distribution and Service
• in 75 countries through the Norgren service network
HERION SystemtechnikSales Partners
ChinaESTUN INDUSTRIAL AUTOMATION CO., LTS155,Jiangjun Road, Jiangning Economical & TechnicalDevelopment Zone, Nanjing, 211100 P.R.C.Tel.: +86-25-52785915E-Mail: info@estun.comwww.estun.com
JapanRiken Optech Corporation2-6-9, Higashi Ohi, Shinagawa-ku,Tokyo 140-8533Tel.: +81 3 34748602E-Mail: contact@rikenoptech.comwww.rikenoptech.com
KoreaCHUNGWOO CO., LTD.# 416-4 DokjeongriJanganmyun HwaseongsiKyungkido, KoreaTel.: +82 (0)31 351-5340E-Mail: blueox2@unitel.co.krwww.chungwooco.co.kr
SpainEUROTECH SYSTEMS, S.L.Av. Can LLuch, 2508690 SANTA COLOMA DE CERVELLOTel: +34 93 634 0101E-Mail: eurotech@eurotechsys.comwww.eurotechsys.com
South AfricaErnest Lowe ELCOPneumatic & Hydraulic Automation Solutions6, Skew Road, Boksburg North 1459,Gauteng, South AfricaTel.: +27 (11) 898-6600E-Mail: corporate@elco.co.zawww.elco.co.za
TaiwanFull Life Trading Co., Ltd.16F-4, No.2, Jian Ba Rd. Chung Ho CityTaipei County, Taiwan 23562Tel.: +886-2-82261860E-Mail: sales-dept@fulllifetrading.comwww.fulllifetrading.com
TurkeyPower Pnomatik Proses A. SNecatibey Cad. No:44/2KaraköyÝstanbul 34420Tel.: +90 212 2938870E-Mail: info@powerpnomatik.comwww.powerpnomatik.com
3 Symbol
4 Engineeringversion: 6
5 Additional data: O – Standard designM – Mechanical detent 1)
6 Sealing material: V – Viton
Directional Control Valves
Size 6
direct controlled
Port size G 3/8
PN [pmax.] = 315 bar 7501293.06.02.06
DesignThe design is based upon the 5-chamber-system.A spool of hardened steel slides in a housing made ofhigh-strength cast-iron. The units are therefore suitablefor rough operating conditions.
ActuationThe directional control valves can be actuated eitherelectromagnetically, electropneumatically, hydraulically,pneumatically, mechanically or by spring.
MountingBy means of bolts onto equipment rack, etc., or to pipeline.
Line connectionPort size G 3/8.
Description (standard units)
• Good guidance of the spool (5-chamber system)- this means reliable switching even with long restperiod
• No dynamic seals• Delay of switching time by exchangeable nozzle• Solenoids with pressure-tight core tube (tube secured)
to valve body by means of central thread). No need toopen pressure-tight space when replacing coil
• Valves with Viton seals standard• Coils designed for DC voltage. AC operation via
connector equipped with rectifier• No dynamic seals
Features
HERION Systemtechnik GmbHUntere Talstraße 65
D-71263 Weil der Stadt-Merklingen
Tel.: +49 (0) 70 33/30 18-0
Fax: +49 (0) 70 33/30 18-10
www.herion-systemtechnik.de
info@herion-systemtechnik.de
1 Actuation: VH – DC solenoid, pressure-tightwith manual override
Other actuations e.g. pneumatical hydraulical by rollerlever or by hand on request.
2 Electricalconnection: 00 – Actuation without
electrical connection
10 – Plug socket Pg 11to DIN 43650 on solenoid
11 – Plug socket Pg 11to DIN 43650 on solenoidand incorporated rectifier
13 – Plug socket Pg 11to DIN 43650 on solenoid,plug socket provided withsignal indicator
Symbol Symbol
No.
001 3)
020
019 2)
+
+
+
008
009
013
+
+
-
Over-
lap
Symbol Symbol
No.
Over-
lap
Type code
S 6 ... ... S 3 ... 001 ... ... ...
1 2 3 4 5 6
Directional control valve
1)on request
2)2-position valves available with detent for all types of actutor, except roller tappet
(R). 3-position valve can only be arrested by means of a hand lever.3)
Port T of these 3/2 directional control valves is used as leak oil connection.
Other parameters
Manual override yes
Switching times appr. [ms]
te 50 ... 80
ta 30 ... 55
Approx. number of switchings/h 15 000
Rated voltage UN [V] Standard voltages
(other voltages 24 ± 10 % 230 V/50 Hz
available on request) + 5 / - 10 %
Current draw P20 [W] DC 31
Duty cycle EDrel [%] 100
Degree of protection for solenoid IP 65
and electrical connection to DIN 40 050
Hydraulic parameters
Operating pressure range pe max. [bar]
at port P, A, B ... 315
at port T ... 160
Pressure fluid temperature ϑm max. [°C] + 70
Viscosity range ν [mm2/s] 12 ... 500
Flow Qmax (l/min) See characteristic curve
Filtering Oil class according to
ISO 4406: 18/15
2 7501293.06.02.06Subject to alteration
Type designation (Actuation) VH 10 ... VH 11 ...
General parameters
Designation Directional control valve
Symbol See type survey and type code
Design Spool-type valve
Type of mounting Flange
Line connection Port size
Mounting position Preferably horizontal
Weight 1 actuator [kg] 1.9 1.9
2 actuators 2.7 2.7
Ambient temperature range ϑu [°C] – 20 ... + 50
Size NG 6
Parameters according to VDI 3267
Symbol Characteristic curve
001
008
009
013
019
020
1
3
2
3
3
3
Flow QmaxLimiting values measured with warmsolenoid and 10% low voltage. Valvepassed though in both directions (P-Aand B-T). Blocking of one port lead tolower switching capacities.
Symbol
001
008
009
013
019
020
5
6
5
3
7
7
5
6
5
3
7
7
-
3
4
1
2
2
-
3
4
1
2
2
-
-
-
8
-
-
Flow direction
P-A P-B A-T B-T P-T
Flow resistance
37501293.06.02.06 Subject to alteration
Ordering Example of order
The units are designated by their type number. Thecomposition of this number can be drawn from the typecode. The standard versions are listed in the typesurvey. When ordering any of the standard versions,please state type number as well as catalog number topreclude possible misinterpretations.When inquiring about or ordering units not listed in ourtype survey of this publication, the type number madeup by you by means of the type code, however, will do.The corresponding catalog number will then be statedin our confirmation of order.
Wanted: 4/3-way directional control valve NG 6, 24 VDC. Electrical connection: Plug socket on solenoid,Symbol 008, port size G 3/8.
Directional control valve:Type No.: S 6 VH 10 S3 008 001 6 O VCat. No.: 5201449.7234
Type survey (standard versions)
Sym
bol N
o.
Overlap
Actu
ation
Dim
ensio
nal
dra
win
g
Spare
part
dra
win
g
Voltage
Symbol Electrical
connection
Line connection Type Cat. No.
Valve
Sole-
noid
0011) 01
01
03
02
02
02
01
01
03
02
02
02
020
019
008
009
013
+
+
+
+
+
-
VDC
VAC
VDC
VAC
VDC
VAC
S 6 VH 10 S3 001 001 6 O V
S 6 VH 11 S3 001 001 6 O V
S 6 VH 10 S3 020 001 6 O V
S 6 VH 11 S3 020 001 6 O V
S 6 VH 10 S3 019 001 6 M V
S 6 VH 11 S3 019 001 6 M V
5201501.7234
5201506.7234
5204087.7234
5204088.7234
5201504.7234
5201508.7234
VDC
VAC
S 6 VH 10 S3 008 001 6 O V
S 6 VH 11 S3 008 001 6 O V
5201449.7234
5201509.7234
VDC
VAC
S 6 VH 10 S3 009 001 6 O V
S 6 VH 11 S3 009 001 6 O V
5201502.7234
5201510.7234
VDC
VAC
S 6 VH 10 S3 013 001 6 O V
S 6 VH 11 S3 013 001 6 O V
5201503.7234
5202029.7234
Sole
noid
actu
ate
d p
ressure
tig
ht No. 10:
Plug socket
to DIN
43650
(Pg 11)
on solenoid
or
No. 11:
Plug socket
to DIN
43650
(Pg 11) on
solenoid
with
incorporated
rectifier
G 3/8
1)Port T of these 3/2 directional control valves is used as leak oil connection.
Dimensional drawings
S 6 VH 10S 6 VH 11 01
S 6 VH 10S 6 VH 11 02
S 6 VH 10 ... MS 6 VH 11 ... M 03
El. connection 11 and 13
El. connection 10
Port,
A, P, B and T
appr. 157
appr. 102
appr. 73
4 7501293.06.02.06Subject to alteration
Spare parts drawings
S 6 VH 10S 6 VH 11 01 02
with mechanical detent03
Spare parts (pieces)
Spare part drawing 01 02 03
Part Designation S 6 VH 10 ... S 6 VH ... 013 S 6 VH 10 ... M Cat. No.S 6 VH 11 ...
Electrical spare parts
Electrical connection, Code 10 Cat. No.
Connector:
Design A (grey) 0657859
Design B (black) 0570275
Electrical connection, Code 11 Cat. No.
Connector:
Design A (grey) 0570322
Design B (black) 0570819
Electrical connection, Code 13 Cat. No.
Design A (grey)Connector +lamp
115 to 130 V DC 0570256115 to 160 V AC190 to 130 V AC or 0656553100 to 130 V DC
150 to 250 V AC/DC 0656552
Design B (black)Connector +lamp
115 to 130 V DC 0570818115 to 160 V AC190 to 130 V AC or 0570816100 to 130 V DC
150 to 250 V AC/DC 0570817
1
2
2
3
2
1 or 2
1 or 2(rectifier connector seeelectrical spare parts)
-
2
1 or 2
1
3
2
1
0661476
7234
7234
0660227
O-ring (17 x 2)
DC-solenoid(voltage)
For use of AC voltage:DC-solenoid with rectifierconnector(voltage value is necessary)
Sealing ring 5.7 x 9 x 1
Tightening
torque
5.5 ± 0.5 NmSW 20
Tightening
torque
30 ± 3 Nm
SW 24
Tightening
torque
30 ± 3 Nm
Only symbol 013
SW 24
Tightening
torque
6 ± 1 Nm
SW 4
Tightening
torque
6 ± 1 Nm
SW 4
Tightening
torque
7.6 ± 0.3 Nm
17501294.06.07.13
Directional control valves DN 6 directly actuatedInterface to DIN 24 340 and ISO 4401 (CETOP03)
PN [pmax.] = 350 bar
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
Increased safety through electrical position monitoring
5-chamber system
No dynamic seals
Delay of switching time by exchangeable nozzle (optional)
Pulse mode through mechanical detent (optional)
Wet type solenoid with pressure-tight core tube
Easy replacement of solenoids. Solenoids with pressure-tight core tube (tube secured to valve body by means of central thread).
Valves with Viton seals standard
Coils designed for DC voltage. AC operation via connector equipped with rectiier
General parameters
Designation: Directional control valve
Symbol:See type survey or type key
Design: Spool-type valve
Type of mounting: Flange
Line connection: Subplate
Mounting position: Preferably horizontal
Weight of valve with: 1 actuator [kg]: 2.1 2 actuators [kg]: 3.1
Weight of subplat.: G 1/4 [kg]: 0.7 G 3/8 [kg]: 1
Ambient temperature range Ju [°C]:-20 to +50
Size: DN 6
MTTFd [years]:150
Technical dataHydraulic parameters
Operating pressure pemax. [bar]at port P, A, B:up to 350 at port T: up to 50
Pressure luid temperature Ju max. [°C]:+70
Viscosity range: n [mm2/s]:12 to 500
Flow Qmax [l/min]:See characteristic curves
Filtration: Oil purity class to ISO 4406: 18/15
Further parameters
Standard: with or without manual override
Switching times, approx. [ms]: ton: 50 to 80 toff: 30 to 55
Rated voltage connector input UN [V]: Standard voltages: VH 10 VH11 (VH 13) (VH 12) 24 DC 230 AC 40...60 Hz +5%/-10% +5%/-10%
Further voltages: VH10 VH11* 12 DC 24 DC 48 DC 98 DC 110 AC 110 DC 125 DC 185 DC 205 DC 230 AC 220 DC 230 DC
* via connector rectiier
Power consumption P20 [W]: 31
Duty cycle [%]:100
Degree of protection for solenoid and electrical connection to DIN 40050: IP 65
7501294.06.07.132
Directional control valves DN 6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
Electrical parameters (electronic limit switch)
Wiring diagram Pin assignment limit switch
pnp normally open
pnp-antivalent (optional)antivalent on demand
Electronical limit switch M 12x1:PNP-Schließer (oder antivalent auf Anfrage)
Rated operational voltage UE [V] DC: 24
Supply voltage UB [V] DC: 10 ... 30
Voltage drop Ud at Ie[V]: ≤1,5
Rated operational current Ie[mA]: 200
Protection against polarity reversal: yes
Short circuit protected/overload protected: yes/yes
Load capacitance [µF]: ≤1,0
Degree of protection per IEC 529: IP 68 to BWN Pr. 20 (IP 67 connector kompl.)
Connection: Connector
pressure rated up to [bar]: 50 an aktiver Fläche
Connector type: angle, female, 4-pin
Cable gland: Pg 7, cable ø 4 to 6 mm
Degree of protection: IP 67
Degree of protection: yes (2)- Power on: green- Function: yellow
+ brown
black
- blue
+ brown
- blue
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501294.06.07.13 3
Directional control valves DN 6
Further symbols on demand
Symbol Symbol No.
Overlap Symbol Symbol No.
Overlap Symbol Symbol No.
Overlap
002 - 038 + 117 +
004 + 039 + 153 -
005 + 082 + 159 +
007 + 086 + 172 +
010 + 087 - 174 +
011 - 088 + 198 +
016 + 090 -
025 + 094 +
0313) +
033 -
Type key
Directional control valve
S 6 ... ... G ... ... 6 ... V
1 2 3 4 5 6 7
1 Actuation: VH – DC solenoid with manual override
V – DC solenoid without manual override
2 Electrical connection: 10 – Connector Pg 11
11 – Connector Pg 11 with rectiier insert on plug
13 – Connector Pg 11 with function indicator on solenoid
3 Symbol: – Extra symbols see below – Standard symbols
see page 5 and 6
Subplate
P S 6 G ... ... 2 O O
1 2
1 Line connection: 2 – G 1/4 (internal thread 3 – G 3/8 to DIN ISO 228/1)
2 Code: 024 – G 1/4 001 – G 3/8
1) Only 2-position valves are available with detent.3) Port T of these 3/2-way valves is to be used as leak oil connection.
4 Engineering: – For switching position indicator see next page
6 Additional data: O – Standard design
M1) – Mechanical detent
7 Sealing material: V – FKM (e.g. Viton
7501294.06.07.134
Directional control valves DN 6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
Code No
for 1 switching position indicator for 2 switching position indicator
4/2 Directional control valve
210
Solenoid A de-energizedSolenoid A energized
Side a Side b01
Solenoid at Signal to position switch
244
Solenoid A de-energizedSolenoid A energized
Side a Side bSide a1001
Solenoid atSignal to position
switch
246
Solenoid B de-energizedSolenoid B energized
Side b Side bSide a0110
Solenoid atSignal to position
switch
245
Solenoid A de-energizedSolenoid A energized
Side a Side bSide a0110
Solenoid atSignal to position
switch
247
Solenoid B de-energizedSolenoid B energized
Side b Side bSide a1001
Solenoid atSignal to position
switch
217
Solenoid A de-energizedSolenoid A energized
Side a Side b
10
Solenoid atSignal to position
switch
242
Solenoid B de-energizedSolenoid B energized
Side b Side a01
Solenoid at Signal to position switch
243
Solenoid B de-energizedSolenoid B energized
Side b Side a10
Solenoid at Signal to position switch
4/2 Directional control valve with detent
222
Solenoid A energized (pulse switching)
Solenoid B energized (pulse switching)
Side b Side a10
Solenoid at Signal to position switch
Side a
223
Solenoid A energized (pulse switching)
Solenoid B energized (pulse switching)
Side b Side a01
Solenoid at Signal to position switch
Side a 238
Solenoid A energized (pulse switching)
Solenoid B energized (pulse switching)
Side b Side a Side b1 00 1
Solenoid at Signal to position switch
Side a
4/3 Directional control valve
208Solenoid A + B de-energizedSolenoid A energizedSolenoid B energized
Side b Side b011
Solenoid at Signal to position switch
Side a
248Solenoid A + B de-energizedSolenoid A energizedSolenoid B energized
Side b Side b100
Solenoid at Signal to position switch
Side a 216Solenoid A + B de-energizedSolenoid A energizedSolenoid B energized
Seite b Side b001
Solenoid at Signal to position switch
Side a Side a010
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501294.06.07.13 5
Directional control valves DN 6
Type survey (standard versions)
Further symbols on request.
- Magnet 24VDC (Futher voltages on request)- With manual override > VH- Without manual override > V- Electrical connection, symbol 10 connector 0570275 (Further plugs on demand)- pnp normally open (andere Nährungsschalter - Ausführungen auf Anfrage)- Operating pressure: at port P, A and B : 350 bar- Operating pressure: at port T : 50 bar (210 bar on request)
Symbol Symbol-No. Code Type Cat. No.
001 210
217
S6 VH 10 G 001 210 6OVS6 VH 10 G 001 210 6OV
S6 VH 10 G 001 217 6OVS6 VH 10 G 001 217 6OV
5205076.7234.024.005205350.7238.024.00
on requeston request
001 244
245
S6 VH 10 G 001 244 6OVS6 VH 10 G 001 244 6OV
S6 VH 10 G 001 245 6OVS6 VH 10 G 001 245 6OV
on requeston request
on requeston request
003 210
217
S6 VH 10 G 003 210 6OVS6 VH 10 G 003 210 6OV
S6 VH 10 G 003 217 6OVS6 VH 10 G 003 217 6OV
on requeston request
on request5205517.7238 024.00
003 244
245
S6 VH 10 G 003 244 6OVS6 VH 10 G 003 244 6OV
S6 VH 10 G 003 245 6OVS6 VH 10 G 003 245 6OV
on requeston request
on requeston request
020 210
217
S6 VH 10 G 020 210 6OVS6 VH 10 G 020 210 6OV
S6 VH 10 G 020 217 6OVS6 VH 10 G 020 217 6OV
5205042.7234.024.005205257.7238 024.00
5205045.7234 024.005205375.7238.024.00
020 244
245
S6 VH 10 G 020 244 6OVS6 VH 10 G 020 244 6OV
S6 VH 10 G 020 245 6OVS6 VH 10 G 020 245 6OV
5205662.7234.024.005205661.7238.000.00
on requeston request
Symbol Symbol-No. Code Type Cat. No.
019 222
223
S6 VH 10 G 013 222 6MVS6 VH 10 G 013 222 6MV
S6 VH 10 G 013 223 6MVS6 VH 10 G 013 223 6MV
5205129.7234.024.00on request
5205208.7234.024.00on request
019 238 S6 VH 10 G 019 238 6MVS6 VH 10 G 019 238 6MV
5205659.7234.024.005205660.7238.024.00
4/2 Directional control valves (standard versions)
with mechanical detent
7501294.06.07.136
Directional control valves DN 6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
Further symbols on request.
Symbol Symbol-No. Code Type Cat. No.
008 208
248
S6 VH 10 G 008 208 6OOS6 VH 10 G 008 208 6OO
S6 VH 10 G 008 248 6OVS6 VH 10 G 008 248 6OV
on requeston request
on requeston request
008 216 S6 VH 10 G 008 216 6OVS6 VH 10 G 008 216 6OV
5205196.7234.024.005205467.7238.024.00
009 208
248
S6 VH 10 G 009 208 6OVS6 VH 10 G 009 208 6OV
S6 VH 10 G 009 248 6OVS6 VH 10 G 009 248 6OV
on requeston request
on requeston request
009 216 S6 VH 10 G 009 216 6OVS6 VH 10 G 009 216 6OV
5205365.7234.024.00on request
013 208
248
S6 VH 10 G 013 208 6OVS6 VH 10 G 013 208 6OV
S6 VH 10 G 013 248 6OVS6 VH 10 G 013 248 6OV
on requeston request
on requeston request
013 216 S6 VH 10 G 013 216 6OVS6 VH 10 G 013 216 6OV
5205098.7234.024.005205384.7238.024.00
4/3 Directional control valves (standard versions)
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501294.06.07.13 7
Directional control valves DN 6
Characteristic curves
Flow curves Q = f(∆p)
Symbol P-A P-B A-T B-T P-T
001 7 7 - - -
003 8 8 3 3 -
008 8 8 6 6 -
009 5 5 9 9 -
013 5 5 4 4 2
019 5 5 1 1 -
020 5 5 1 1 -
Flow direction
Power limits
J = 50oC
υ = 28 mm2/s
Symbol Characteristic curve
001 2
003 4
008 1
009 3
013 5
019 1
020 1
Maximum values determined with solenoid in warmed-up condition and at an undervoltage of 10%. Fluid passing in two directions (from P to A and B to T). If one port is closed, a reduced breaking capacity must be taken into consideration. A reduced breaking capacity must also be taken into consideration for valve types with switching delay (nozzle).
J = 50oC
υ = 28 mm2/s
7501294.06.07.138
Directional control valves DN 6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
Ordering
The units are designated by their type number. The composition of this number can be drawn from the type code. The standard ver- sions are listed in the type survey. When ordering any of the stan- dard versions, please state type number as well as catalog number to preclude possible misinterpretations.Further valve versions can be composed via combination of types - order numbers on request.
Flanged valves are provided with O-rings and connector (type 10, 11 and 13). Subplate and mounting screws must be ordered separately.
Ordering example
Directional control valve:Type No.:S 6 VH 10 G 020 236 6 OVCat. No.:5205046.7234.024.00
4/2-directional control valve DN 6, 24 V=, Electrical connection 10, symbol 020, Schaltstellungs-überwachung an A- und B-Seite (code 236), pnp normally open, subplate G1/4.
Subplate:Type No.:P S 6 G 2 024 2 O OCat. No.:1065173
Mounting screws:(4 pcs. required) Socket-head screw:(M 5 x 30 DIN 912-10.9)Cat. No.:0700387
Design Actuation Mounting Line connection
The directional control valves are actuated electro-mechanically or by spring.
The design is based upon the5-chamber system.A spool of hardened steel slidesin a housing made of high-strength cast-iron. Therefore theunits are suitable for roughoperating conditions.The switch contact at the end positions of the spool can be used, for example, for acknow-ledgements in safety circuits
The units are bolted on sub- plates and sealed by O-rings.
Subplate, interface to DIN 24340 - A6 and ISO 4401 - AB - 03 - 4 - A.
244
Solenoid A de-energizedSolenoid A energized
Side a Side bSide a1001
solenoid atSignal to position
switch
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501294.06.07.13 9
Directional control valves DN 6
Spare parts drawings
Directional control valve
S 6 VH 10 ...S 6 VH 11 ...S 6 VH 13 ... code 210, 217
S 6 VH 10 ...S 6 VH 11 ...S 6 VH 13 ... code 246, 247
S 6 VH 10 ...S 6 VH 11 ...S 6 VH 13 ... code 244, 245
S 6 VH 10 ... MS 6 VH 11 ... M S 6 VH 13 ... M code 222, 223
S 6 VH 10 ... S 6 VH 11 ... S 6 VH 13 ... code 242, 243
~110
61 57
78 ~73~178
~93
~3
~110
61 57
ca. 9
3
ca. 3
27 78 73
ca. 208
7501294.06.07.1310
Directional control valves DN 6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
S 6 VH 10 ...S 6 VH 11 ...S 6 VH 13 ... code 216
S 6 VH 10 ...S 6 VH 11 ...S 6 VH 13 ... code 208, 248
S 6 VH 10 ...S 6 VH 11 ...S 6 VH 13 ... code 238
72.7 78 22 37 72.7
311.9
110
61
57
ca. 9
3ca
. 27
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501294.06.07.13 11
Directional control valves DN 6
Dimensional drawings
Subplate mit interface according to DIN 24 340-A 6 and ISO 4401-AB-03-4-A
G 1/4Type: P S 6 G 2 024 2 O OReference: 1065173
G 3/8Type: P S 6 G 3 001 2 O OReference: 1065183
Aperture for connection in control panel
Aperture for connection in control panel
7501294.06.07.1312
Directional control valves DN 6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
Electrical spare parts
Electrical connection, Symbol 10 Cat. No.
Connector Pg 11 (Operating voltage: 0...300 V DC)
0570275
Electrical connection, Symbol 11 Cat. No.
Connector Pg 11 with rectiier (Operating voltages: 15...250 V AC or10...250 V DC)
0570819
Electrical connection, Symbol 12 Cat. No.
Connector Pg 11 with rectiier and indicator (Operating voltages: 80...130 VAC or 100...130 V DC)
Connector Pg 11 with rectiier and indicator (Operating voltages: 150...250 V AC or 135...250 V DC)
0588568
0571502
Electrical connection, Symbol 13 Cat. No.
Connector Pg 11 with indicator (Operating voltages: 24 V DC)
Connector Pg 11 with indicator (Operating voltages: 90...130 V DC)
Connector Pg 11 with indicator (Operating voltages: 150...250 V DC)
0570818
0570816
0570817
Angle plug connectorProximity switch
Cat. No.
0615517
Further spares
Cat. No.
O-ring (9.2 x 1.8) 0701728
O-ring (22 x 1,5) (26.7 x 1.78) on solenoid
Socket-head screw (M5 x 30 DIN 912-10.5) 0700387
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501294.06.07.13 13
Directional control valves DN 6
HERION Systemtechnik GmbHUntere Talstraße 6571263 Weil der StadtTel.: +49 (0) 7033/3018-0Fax: +49 (0) 7033/3018-10info@herion-systemtechnik.dewww.herion-systemtechnik.de
A subsidiary of the Norgren and IMI group of companies
Distribution and Service
• in 75 countries through the Norgren service network
HERION SystemtechnikSales Partners
ChinaESTUN INDUSTRIAL AUTOMATION CO., LTS155,Jiangjun Road, Jiangning Economical & TechnicalDevelopment Zone, Nanjing, 211100 P.R.C.Tel.: +86-25-52785915E-Mail: info@estun.comwww.estun.com
JapanRiken Optech Corporation2-6-9, Higashi Ohi, Shinagawa-ku,Tokyo 140-8533Tel.: +81 3 34748602E-Mail: contact@rikenoptech.comwww.rikenoptech.com
KoreaCHUNGWOO CO., LTD.# 416-4 DokjeongriJanganmyun HwaseongsiKyungkido, KoreaTel.: +82 (0)31 351-5340E-Mail: blueox2@unitel.co.krwww.chungwooco.co.kr
SpainEUROTECH SYSTEMS, S.L.Av. Can LLuch, 2508690 SANTA COLOMA DE CERVELLOTel: +34 93 634 0101E-Mail: eurotech@eurotechsys.comwww.eurotechsys.com
South AfricaErnest Lowe ELCOPneumatic & Hydraulic Automation Solutions6, Skew Road, Boksburg North 1459,Gauteng, South AfricaTel.: +27 (11) 898-6600E-Mail: corporate@elco.co.zawww.elco.co.za
TaiwanFull Life Trading Co., Ltd.16F-4, No.2, Jian Ba Rd. Chung Ho CityTaipei County, Taiwan 23562Tel.: +886-2-82261860E-Mail: sales-dept@fulllifetrading.comwww.fulllifetrading.com
TurkeyPower Pnomatik Proses A. SNecatibey Cad. No:44/2KaraköyÝstanbul 34420Tel.: +90 212 2938870E-Mail: info@powerpnomatik.comwww.powerpnomatik.com
17501292.06.08.13
Directional control valves DN 6 directly actuatedInterface to DIN 24 340 and ISO 4401 (CETOP03)
PN [pmax.] = 350 bar
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
5-chamber system
No dynamic seals
Delay of switching time by exchangeable nozzle (optional)
Pulse mode through mechanical detent (optional)
Wet type solenoid with pressure-tight core tube
Optional: without manual override
Easy replacement of solenoids. Solenoids with pressure-tight core tube (tube secured to valve body by means of central thread). No need to open pressure-tight space when replacing solenoid.
Valves with Viton seals standard
Coils designed for DC voltage. AC operation via connector equipped with rectiier
General parameters
Designation: Directional control valve
Symbol:See type survey or type key
Design: Spool-type valve
Type of mounting: Flange
Line connection: Subplate
Mounting position: Preferably horizontal
Weight of valve with: 1 actuator [kg]: 1.9 2 actuators [kg]: 2.5
Weight of subplat.: G 1/4 [kg]: 0.7 G 3/8 [kg]: 1
Ambient temperature range Ju [°C]:-20 to +50
Size: DN 6
MTTFd [years]:150
Technical dataHydraulic parameters
Operating pressure pemax. [bar]at port P, A, B:up to 350 at port T: up to 210
Pressure luid temperature Ju max. [°C]:+70
Viscosity range: n [mm2/s]:12 to 500
Flow Qmax [l/min]:See characteristic curves
Filtration: Oil purity class to ISO 4406: 18/15
Further parameters
Manual override: Standard
Switching times, approx. [ms]: ton: 50 to 80 toff: 30 to 55
Rated voltage connector input UN [V]: Standard voltages: VH 10 VH11 (VH 13) (VH 12) 24 DC 230 AC 40...60 Hz1) +5%/-10% +5%/-10%
Further voltages: VH10 VH11* 12 DC 24 DC 48 DC 98 DC 110 AC 110 DC 125 DC 185 DC 205 DC 230 AC 220 DC 230 DC
* via connector rectiier
Power consumption P20 [W]: 31
Duty cycle [%]:100
Degree of protection for solenoid and electrical connection to DIN 40050: IP 65
1) when using a DC-type solenoid 205 V with rectiier
7501292.06.08.132
Directional control valves DN 6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
Type survey (standard versions)
Symbol Symbol-No. Overlap Voltage Type Cat. No.
0011) + VDC24V
VAC230
S6VH10 G 001 001 6 O VS6VH13 G 001 001 6 O V
S6VH11 G 001 001 6 O VS6VH12 G 001 001 6 O V
5203939.7234.024005205576.7234.02400
5204084.7234.205005205575.7234.20500
003 - VDC24V
VAC230
S6VH10 G 003 001 6 O VS6VH13 G 003 001 6 O V
S6VH11 G 003 001 6 O VS6VH12 G 003 001 6 O V
5203940.7234.024005205428.7234.02400
5204158.7234.20500 5205570.7234.20500
020 + VDC24V
VAC230
S6VH10 G 020 001 6 O VS6VH13 G 020 001 6 O V
S6VH11 G 020 001 6 O VS6VH12 G 020 001 6 O V
5203941.7234.024005201045.7234.02400
5204082.7234.205005205176.7234.20500
019 + VDC24V
VAC230
S6VH10 G 019 001 6 M VS6VH13 G 019 001 6 M V
S6VH11 G 019 001 6 M VS6VH12 G 019 001 6 M V
5203942.7234.024005201367.7234.02400
5204089.7234.205005205571.7234.20500
008 + VDC24V
VAC230
S6VH10 G 008 001 6 O VS6VH13 G 008 001 6 O VS6VH11 G 008 001 6 O VS6VH12 G 008 001 6 O V
5203943.7234.024005205338.7234.02400
5204092.7234.205005205572.7234.20500
009 + VDC24V
VAC230
S6VH10 G 009 001 6 O VS6VH13 G 009 001 6 O V
S6VH11 G 009 001 6 O VS6VH12 G 009 001 6 O V
5203944.7234.02400 5205344.7234.02400
5204093.7234.205005205174.7234.20500
013 - VDC24V
VAC230
S6VH10 G 013 001 6 O VS6VH13 G 013 001 6 O V
S6VH11 G 013 001 6 O VS6VH12 G 013 001 6 O V
5203945.7234.024005203876.7234.02400
5204094.7234.20500 5205573.7234.20500
1) Port T of these 3/2 directional control valves is used as leak oil connection.
Connecting plate
Type Cat. No.
G 1/4 P S 6 G 2 024 2 O O 1065173
G 3/8 P S 6 G 3 001 2 O O 1065183
Ordering
The units are designated by their type number. The composition of this number can be drawn from the type code. The standard ver- sions are listed in the type survey. When ordering any of the stan- dard versions, please state type number as well as catalog number to preclude possible misinterpretations.Further valve versions can be composed via combination of types - order numbers on request.
Flanged valves are provided with O-rings and connector (type 10 or 11, Page 2). Subplate and mounting screws must be ordered separately.
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501292.06.08.13 3
Directional control valves DN 6
Type key
Directional control valve
S 6 ... ... G ... 001 6 ... V
1 2 3 4
1 Actuation: V – Without manual override VH – With manual override
2 Electrical 10 – Connector Pg 11 connection: 11 – Connector Pg 11
with rectiier insert on solenoid 12 – Connector Pg 11
with rectiier insert and function indicator on solenoid
13 – Connector Pg 11 with function indicator on solenoid
3 Symbol: – Standard symbols see page 2 – Extra symbols see below
4 Additional data: O – Standard design M1) – Mechanical detent C2) – Switching delay by means of nozzle
Extra symbols
Symbol Symbol No.
Overlap Symbol Symbol No.
Overlap Symbol Symbol No.
Overlap
002 - 038 + 117 +
004 + 039 + 153 -
005 + 082 + 159 +
007 + 086 + 172 +
010 + 087 - 174 +
011 - 088 + 198 +
016 + 090 -
025 + 094 +
0313) +
033 -
Weitere Symbole auf Anfrage
Subplate
P S 6 G ... ... 2 O O
1 2
1 Line connection: 2 – G 1/4 (internal thread 3 – G 3/8 to DIN ISO 228/1)
2 Code: 024 – G 1/4 001 – G 3/8
1) Only 2-position valves are available with detent.2) Port T of valves with a delayed switching time has to be pressurized with
approx. 5 bar.3) Port T of these 3/2-way valves is to be used as leak oil connection.
7501292.06.08.134
Directional control valves DN 6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
Ordering example
Directional control valve:Type No.:S 6 VH 10 G 010 001 6 O VCat. No.:5204099723402400
Wanted: 4/3 directional control valve DN 6, 24 VDC, solenoid with plug, symbol 010, along with corresponding subplate G 1/4.
Subplate:Type No.:P S 6 G 2 024 2 O OCat. No.:1065173
Mounting screws:(4 pcs. required) Socket-head screw:(M 5 x 30 DIN 912-10.9)Cat. No.:0700387
Design Actuation Mounting Line connection
The directional control valves are electromagnetically operated, with spring return for the standard valves. The piston of valves with mechanical detent remains in energized position even if de-energized.
The design is based upon the 5-chamber system. A spool of hardened steel slides in a housing made of high- strength cast-iron. Therefore the units are suitable for rough operating conditions and guarantee reliable switching, even with long rest periods.
The units are bolted on sub- plates and sealed by O-rings.
Subplate, interface to DIN 24340-A6 and ISO 4401-AB-03-4-A.
Dimensional drawings
Directional control valve
S 6 V ...S 6 VH ...
Tightening torque max. 30 Nm
Connector 11, 12 and 13
solenoid “a”Interface S6to DIN 24340-A6 and ISO 4401
Surface of counterpartRz max. 4
Coil rotatableby 90°
Tightening torque max. 6 Nm
ManualoverrideonlyS6 VH ...
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501292.06.08.13 5
Directional control valves DN 6
Dimensional drawings
Directional control valve
S 6 V ... M ...S 6 VH ... M ...
Subplate with interface according to DIN 24 340-A 6 and ISO 4401-AB-03-4-A
G 1/4Type: P S 6 G 024 2 O O Reference: 1065173
G 3/8Type: P S 6 G 3 001 2 O O Reference: 1065183
solenoid “a” solenoid “b”
Aperture for connection in control panel
Aperture for connection in control panel
7501292.06.08.136
Directional control valves DN 6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
Characteristic curves
Flow curves Q = f(∆p)
Symbol P-A P-B A-T B-T P-T
001 7 7 - - -
003 8 8 3 3 -
008 8 8 6 6 -
009 5 5 9 9 -
013 5 5 4 4 2
019 5 5 1 1 -
020 5 5 1 1 -
Flow direction
Power limits
J = 50oC
υ = 28 mm2/s
Symbol Characteristic curve
001 2
003 4
008 1
009 3
013 5
019 1
020 1
Maximum values determined with solenoid in warmed-up condition and at an undervoltage of 10%. Fluid passing in two directions (from P to A and B to T). If one port is closed, a reduced breaking capacity must be taken into consideration. A reduced breaking capacity must also be taken into consideration for valve types with switching delay (nozzle).
J = 50oC
υ = 28 mm2/s
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501292.06.08.13 7
Directional control valves DN 6
Spare parts drawings
S 6 V ... S 6 VH ...
S 6 V ... MS 6 VH ... M
with mechanical detent
S 6 V ... C ...S 6 VH ... C ...
Switching time delay with nozzle
Spare parts kit
0615057, containing:4 x O-ring ref. 0701728 Pos. 12 x O-ring ref. 0681632 Pos. 2
Sealings are exclusively available as spare parts kit.
Repairs and maintenance must only be carried out by the valve manufacturer or authorized personnel.
for 3/4 - directional valve
7501292.06.08.138
Directional control valves DN 6
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
Electrical spare parts
Electrical connection, Symbol 10 Cat. No.
Connector Pg 11 (Operating voltage: 0...300 V DC)
0570275
Electrical connection, Symbol 11 Cat. No.
Connector Pg 11 with rectiier (Operating voltages: 15...250 V AC or10...250 V DC)
0570819
Electrical connection, Symbol 12 Cat. No.
Connector Pg 11 with rectiier and indicator (Operating voltages: 80...130 VAC or 100...130 V DC)
Connector Pg 11 with rectiier and indicator (Operating voltages: 150...250 V AC or 135...250 V DC)
0588568
0571502
Electrical connection, Symbol 13 Cat. No.
Connector Pg 11 with indicator (Operating voltages: 24 V DC)
Connector Pg 11 with indicator (Operating voltages: 90...130 V DC)
Connector Pg 11 with indicator (Operating voltages: 150...250 V DC)
0570818
0570816
0570817
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7501292.06.08.13 9
Directional control valves DN 6
HERION Systemtechnik GmbHUntere Talstraße 6571263 Weil der StadtTel.: +49 (0) 7033/3018-0Fax: +49 (0) 7033/3018-10info@herion-systemtechnik.dewww.herion-systemtechnik.de
A subsidiary of the Norgren and IMI group of companies
Distribution and Service
• in 75 countries through the Norgren service network
HERION SystemtechnikSales Partners
ChinaESTUN INDUSTRIAL AUTOMATION CO., LTS155,Jiangjun Road, Jiangning Economical & TechnicalDevelopment Zone, Nanjing, 211100 P.R.C.Tel.: +86-25-52785915E-Mail: info@estun.comwww.estun.com
JapanRiken Optech Corporation2-6-9, Higashi Ohi, Shinagawa-ku,Tokyo 140-8533Tel.: +81 3 34748602E-Mail: contact@rikenoptech.comwww.rikenoptech.com
KoreaCHUNGWOO CO., LTD.# 416-4 DokjeongriJanganmyun HwaseongsiKyungkido, KoreaTel.: +82 (0)31 351-5340E-Mail: blueox2@unitel.co.krwww.chungwooco.co.kr
SpainEUROTECH SYSTEMS, S.L.Av. Can LLuch, 2508690 SANTA COLOMA DE CERVELLOTel: +34 93 634 0101E-Mail: eurotech@eurotechsys.comwww.eurotechsys.com
South AfricaErnest Lowe ELCOPneumatic & Hydraulic Automation Solutions6, Skew Road, Boksburg North 1459,Gauteng, South AfricaTel.: +27 (11) 898-6600E-Mail: corporate@elco.co.zawww.elco.co.za
TaiwanFull Life Trading Co., Ltd.16F-4, No.2, Jian Ba Rd. Chung Ho CityTaipei County, Taiwan 23562Tel.: +886-2-82261860E-Mail: sales-dept@fulllifetrading.comwww.fulllifetrading.com
TurkeyPower Pnomatik Proses A. SNecatibey Cad. No:44/2KaraköyÝstanbul 34420Tel.: +90 212 2938870E-Mail: info@powerpnomatik.comwww.powerpnomatik.com
2/2 and 3/2 Way Size 6
Seat ValvesDirectly operated
Interface and subplate dimensions according to DIN 24340 and ISO
Line connection port size G 3/8"
Cartridge design
PN [pmax.] = 315 bar 7501856.06.12.08
ApplicationDirectional valves are used to influence the flow of oil inhydraulic systems (start, stop and change direction).
DesignThese directional seat valves are designed as poppetvalve. Both the cone and the valve seat are made fromhardened steel, making the units suitable for roughoperating conditions.
ActuationThe directional seat valves are operated by directcurrent solenoids and springs.
MountingThe valves are bolted on subplates and sealed by O-rings. The line connector, subplate and subplatedimensions are according to DIN 24340 and ISO;the threaded connection is G 3/8” (BSP).
Description (standard units)
• Bi-directional flow
• Flow rate up to 20 l/min
• Proven cone seat principle
• High pressure wet-armature solenoid can bechanged without opening the hydraulic system
Characteristics
HERION Systemtechnik GmbHUntere Talstraße 65
D-71263 Weil der Stadt (Merklingen)
Tel.: +49 (0) 70 33/30 18-0
Fax: +49 (0) 70 33/30 18-10
www.herion-systemtechnik.de
info@herion-systemtechnik.de
Type Codes
Directional control valve
S C 6 ... ... ... ... 001 ... O ...
1 2 3 4 5 6
Mounting plate
P S 6 G ... 001 ... O O
1 2
1 Actuation: VH – DC-type solenoid,pressure-tight, with manualoverride
VG – DC-type solenoid,pressure-tight, with manualoverride and rectifier onsolenoid
1) HM – Hand lever with detentdevice
1) N – Pneumatic1) Y – Hydraulic2) V – Without manual override
2 Electricalconnection: 10 – Connector Pg 11 to
DIN 43650 on solenoid
13 – Connector Pg 11 to DIN 43650 on solenoid,plug socket provided withsignal indicator
1 Line connector: 2 – G 1/4 (Internal thread 3 – G 3/8 according to
DIN ISO228/1)
2 Revision: 2
3 Line connector: E – Cartridge design
G – Interface and subplatedimensions according toDIN 24340 and ISO
S3 – Port size G 3/8” (BSP)
4 Symbol: – see Configuration
5 Engineering version: 12 – only 5200454.7060
and 5200890.7060
6 Seal material: O – NBR (e.g. Perbunan)V – FKM (e.g. Viton)
1) Only deliverable on request2) See blind insert (spare part no. 6)
Type Description S C 6 VH 10 G ... S C 6 VH 10 S3 ... S C 6 VH 10 E ...
S C 6 VG 10 G ... S C 6 VG 10 S3 ... S C 6 VG 10 E ...
General parameters
Designation Directional seat valve
Symbol See type survey
Design Poppet valve
Type of mounting Flange
Line connection Subplate
Mounting position any, preverable horizontal
Weight of valve [kg] 1.75 1.65 0.85
Weight of subplate G 1/4” [kg] 0.7
G 3/8” 1.0
Ambient temperature range ϑu [°C] -20 ... +50
Size NG 6
Hydraulic Characteristics
Operating pressure
at port P, A, and T pe max. [bar] ... 315
Pressure fluid temperature ϑm max. [°C] -20 ... +70
Viscosity range ν [mm2/s] 3 ... 300
Flow rate Qmax. [l/min] see characteristic curve
Flow direction any
Further characteristics
Switching times, approx. [ms]
te 60 ... 250 (depends on direction of flow,
ta 10 ... 160 flow rate and pressure)
Number of switchings/h, up to 11 600 at 315 bar
approx. up to 11 000 at 210 bar
Rated voltage UN [V] ±5% Standard voltages:
DC 12; 24; 190
(Special voltages on request) AC 24; 110; 220; 40 ... 60 Hz
Power consumption P20 [W] ( ) 38
Duty rating EDrel [%] 100
Degree of protection for solenoid and
electrical connection to. DIN 40050 IP 65
2 7501856.06.12.08Design subject to change without notice
Parameter to VDI 3267
Characteristic curves
Vp = f (Q)
for symbol 181 cartridge design
37501856.06.12.08 Design subject to change without notice
Ordering Example of order
The units are designated by their type number. Thecomposition of this number can be drawn from the typecode. The standard versions are listed in the typesurvey. When ordering any of the standard versions,please state type number as well as catalog number topreclude possible misinterpretations.When inquiring about ordering units not listed in ourtype survey of thid publication, the type number by youby means of the type code, however, will do. Thecorresponding catalog number will be than stated in ourconfirmation order.Flange valves are provided with O-rings. Subplate andmounting screws must be ordered seperately.
3/2 way directional seat valve size 6, 24 V DC,connector on solenoid, symbol 155, along withcorresponding subplate.
Directional control valve:Type No.: S C 6 VH 10 G 155 001 2 O OCat. No.: 5200454.7060
SubplateType No.: P S 6 G 2 024 2 O OCat. No.: 1065173
Mounting screws: (4pcs. required)Socked- head screw (M 5 x 30 DIN 912-10.9)Cat. No.: 0700387
Configuration (Standard configurations)
Symbol Electricalconnection
SymbolNo.
Line connecton Voltage
Type
Type Order No.:
Valve Solenoid
155
168
155
155
181
Type 10
connector
to DIN
43650
(Pg 11)
mounted
on solenoid
Actuation
solenoid
operated,
pressure -
tight
S C 6 VH 10 G 155 001 2 O OS C 6 VG 10 G 155 001 1 O O
S C 6 VH 10 G 168 001 2 O OS C 6 VG 10 G 168 001 1 O O
S C 6 VH 10 S3 155 001 1 O OS C 6 VG 10 S3 155 001 1 O O
S C 6 V H 10 E 155 001 1 O OS C 6 VG 10 E 155 001 1 O O
S C 6 V H 10 E 181 001 1 O OS C 6 VG 10 E 181 001 1 O O
5200454.70601065096.7061
5200890.70601065097.7061
1065118.70601065120.7061
1065098.70601065099.7061
1065100.70601065101.7061
Flange mounted
Subplate G 1/4"
P S 6 G 2 024 2 O O
Cat. no. 1065173
Subplate G 3/8"
P S 6 G 3 001 2 O O
Cat. no. 1065183
Line connection
Port sizeG 3/8" (BSP)
Cartridge design
Symbol SymbolNo.
Line connecton Voltage
Type
Order No.:
Valve Solenoid
181
182
181
182
168
181
182
Possible switching functions
From symbol 155User to close connection T.
From symbol 168User to close connection T.
From symbol 155User to close connection T.
From symbol 155Supply pressure to be connected toconnection T and load to connection A.User to close connection P.
From symbol 155Supply pressure to be connected toconnection T and output to connection P.Load remains on connection A.
From symbol 155Connection T is not to be opened by theuser.
From symbol 155Input to be connected to connection T andload to connection A. Connection P is not tobe bored out by the user.
5200454.70601065096.7061
5200890.70601065097.7061
1065118.70601065120.7061
1065118.70601065120.7061
1065098.70601065099.7061
1065098.70601065099.7061
1065098.70601065099.7061
Flange mounted
Threaded mounting
Cartridge design
The ’G’ thread code (acc. to DIN ISO 228/1) replaces the ’R’ code (acc. to DIN 259) used up until now.
The following switching functions are achieved by closing the T or P connections or by exchanging the inlet and outlet line connections.
4 7501856.06.12.08Design subject to change without notice
Dimensional Drawings
Directional seat valve S C 6 VH 10 G 155 (168) 001 2 O OS C 6 VG 10 G 155 (168) 001 1 O O
2/2 way seat valve flange mounted3/2 way seat valve flange mounted
Directional seat valve S C 6 VH 10 S3 155 001 2 O OS C 6 VG 10 S3 155 001 1 O O
2/2 way seat valve line port connection manual override
1) with signal indicator in socket: size = 86 mm2) with signal indicator in socket: size = 62 mm
manual override
tightening torque
MA = 7.6 Nm
manual override
57501856.06.12.08 Design subject to change without notice
Dimensional Drawings
Directional seat valve S C 6 VH 10 E 181 001 1 O OS C 6 VG 10 E 181 001 1 O O
2/2 way seat valve cartridge design
Directional seat valve S C 6 VH 10 E 155 001 1 O OS C 6 VG 10 E 155 001 1 O O
3/2 way seat valve cartridge design
1) with signal indicator in socket: size = 86 mm2) with signal indicator in socket: size = 62 mm
manual override
Fee space 150 mmto disassemble
solenoid and valve
24.8+ 1.2 mm stroke
Optional
Flange Y 45
manual override
Fee space 150 mm todisassemble
solenoid and valve
Flange Y 45
6 7501856.06.12.08Design subject to change without notice
Dimensional Drawings
Subplates with interface to DIN 24 340-A 6 and ISO 4401-AB-03-4-AG 1/4"
G 3/8"
Aperture forconnections incontrol panel
Aperture forconnections incontrol panel
77501856.06.12.08 Design subject to change without notice
Spareparts drawings
2/2 way seat valveS C 6 VH 10 E 181 001 2 O OS C 6 VG 10 E 181 001 2 O O
3/2 way seat valveS C 6 VH 10 G 155 001 2 O OS C 6 VG 10 G 155 001 1 O OS C 6 VH 10 G 168 001 2 O OS C 6 VG 10 G 168 001 1 O OS C 6 VH 10 S3 155 001 1 O OS C 6 VG 10 S3 155 001 1 O OS C 6 VH 10 E 155 001 1 O OS C 6 VG 10 E 155 001 1 O O
5 and 6
5 and 6
8 7501856.06.12.08Design subject to change without notice
Individual Spare Parts
Part
1 3/2 way valve insert 1 1 1 - 0724842(complete)
1 2/2 way valve insert -- - - 1 0724843(complete)
2 DC solenoid 1 1 1 1 7060(specify voltage)
2 DC solenoid with rectifier 1 1 1 1 7061(specify voltage)
3 Knurled nut 1 1 1 1 0724844
4 Ring 1 1 1 1 0724845
5 Manual override (complete) 1 1 1 1 0724846
6 Plug 1 1 1 1 0724847
7 Connector 1 1 1 1 0657859
8 O-ring (15.6 x 1.8) 1 1 1 1 0701489
9 O-ring (14 x 1.8) 2 2 2 1 0701488
10 Socket head screw (M 5 x 10) - 4 - - 0700381
10 Socket head screw (M 5 x 20) 4 - 4 4 0700385
11 O-ring (6.1 x 1.8) 1 1 1 1 0701483
12 O-ring (9.2 x 1.8) 3 - - - 0701485
Mounting screws (must be ordered separately)
13 Socket head screws 4 - - - 0700387(M 5 x 30 DIN 912-10.9)
1 Set wearing parts consists of parts 8, 9, 11 and 12.
S C 6 VH 10 G 155
S C 6 VG 10 G 155
S C 6 VH 10 G 168
S C 6 VG 10 G 168
S C 6 VH 10 S3 155
S C 6 VG 10 S3 155
S C 6 VH 10 E 155
S C 6 VG 10 E 155
S C 6 VH 10 E 181
S C 6 VG 10 E 181
Order No.:Description Type
Electrical Spare Parts
Electrical conneciton, Symbol 10 Cat. No.:
Connector:Version A (grey) 0657859
Electrical connection, Symbol 13 Cat. No.:
Connector:Version A (grey) 0657833
Indicator lamp unit
112 to 128 V and ∼ 0659319
190 to 130 V or180 to 130 V ∼ 0659320
180 to 240 V and ∼ 0659321
Directional control Valve
size 25
Pilot operated
Spool type valve
Interface acc. to DIN 24340 and ISO 4401
PN [pmax.] = 315 bar 7501298.06.12.08
DesignThe S 25 type valves are spool type valves available in4/2- and 4/3-way designs. The valves can be used as2- or 3-way designs by closing the appropriate ports.
ActuationPilot operated valves are operated by solenoids. Theauxiliary manual operation is only effective when controlpressure is available.
MountingThe units are bolted on subplates and sealed byO-rings.
Line connectorSubplate, interface to DIN 24340-A25 and ISO 4401-AE-08-4-A.
Description (Standard Appliances)
Type key
1 Actuation: VH – DC-type solenoid,pressure-tight,with manual override
HERION Systemtechnik GmbHUntere Talstraße 65
D-71263 Weil der Stadt (Merklingen)
Tel.: +49 (0) 70 33/30 18-0
Fax: +49 (0) 70 33/30 18-10
www.herion-systemtechnik.de
info@herion-systemtechnik.de
S 25 ... ... ... G ... ... ... ... ...
1 2 3 4 5 6 7 8
Directional valve
2 Control type
Pilot Control oil Control oil Timedinlet X outlet Y settings
17- S 6 internal external none18- S 6 external external none19- S 6 internal external available20- S 6 external external available21- S 6 internal internal none22- S 6 external internal none23- S 6 internal internal available24- S 6 external internal available
3 Electrical connection:
10 - PG 11 socket accordingto DIN 43650 mountedon solenoid
11 - PG 11 socket accordingto DIN 43650 mountedon solenoid withintegrated rectifier
13 - PG11 socket accordingto DIN 43650 mountedon solenoid, signalindicator mounted on socket
2 7501298.06.12.08Design subject to chenge without notice
4 Symbols:
Symbol No. Symbol Overlap
020 +
005 +
019 +
008 +
009 +
010 +
011 1) -
013 1) -
Type key
5 Armature: 001 – Standard configuration
6 Engineering version: 2 – with pilot valve size 6
7 Additional data: O – Standard configurationM – mechanical detend of the
pilot valveR – Pilot cartridge in port
P1) (main valve)E – mechanical detend of the
pilot valve and prechargecartridge valve in P-portfrom main valve
8 Seal material: O – PerbunanV – Viton
Subplate
P S 25 G ... 001 ... O O
1 2
1 Line connector: 6 – G 1"7 – G 1 ¼”8 – G 1 ½”
(Internal threadaccording to DINISO 228/1)
2 Engineering Revision: 2
For the symbols shown:Solenoid operated valve with control pattern 17with hydraulic and direct pneumatic operation.
1) Control patterns 17, 19, 21 and 23 are only possiblein conjunction with symbol 013 with a prechargecartridge valve in P.
37501298.06.12.08 Design subject to chenge without notice
Type designation S 25 VH
General parameters
Designation Directional control valve
Type Spool-type valve
Symbol See type key
Mounting type Flange
Line connector Subplate
Weight of valve [kg]1 actuator 16.6
2 actuators 17.2
Weight of subplate [kg]G 1, G 1 1/4 9.2
G 1 1/2 24.2
Weight ofdouble-throttlenon-return valve [kg] 1.9
Mounting position any
Ambient temperaturerange ϑu [°C] –20 bis +50
Nominal size NG 25
Parameter to VDI 3267
Type designation S 25 VH
Hydraulic parameters
Operating pressurerange p [bar]
X = extern 315
Port P, A, B: X = intern 315
Port T: X = extern 315
Y = intern 100
Control pressure 8to
pSt [bar]1) 315
Control volume VSt [cm3]Symbol020, 019 19,5
005, 008, 009,010, 011, 013 9,7
Temperature of max.pressure medium ϑm [°C] +70
Viscosity range ν [mm2/s] 12 bis 500
Flow valume Q [l/min] see characeristic curves
Electrical parameters
Operation VH
Switching time 2) te [ms] 50(pilot valve) ta [ms] 30
No. of switchings/h approx. 15 000
Rated voltage UN [V] 24
Nennspannungstoleranz VUN Special voltages onrequest(± 10%)
Current P20 [W] 32draw
P20 [VA] ∼ -
Duty cycle EDrel [%] 100
Degree of protection for solenoidand elictrical connection toDIN 40 050 IP 54
Electrical connection see Type keys
Characteristic curves
1) For symbols 011 and 013 the control pressure isachieved by the precharge cartridge valve in P.
2) The main valve switching time is dependant on thecontrol oil supply
Pilot cartridge in P
4 7501298.06.12.08Design subject to chenge without notice
Control modes
Control type: 17
Internal control oil feed:
Port “X“ in subplate closed.
Port “p“ in main valve opened.
External control oil feed:
Port for control oil return in “Y“ in subplate.
Port “t“ in main valve closed.
Control type: 18
External control oil feed:
Port for control oil in “X“ in subplate.
Port “p“ in main valve closed.
External control oil return:
Port for control oil return in “Y“ in subplate.
Port “t“ in main valve closed.
Control type: 19
Switching time settings:
The switching times of the main valve can be
influenced by a double throttle non-return valve,
which throttles the control oil supply.
The switching times are changed with the following
settings:
Throttle 1: from 0 to a
from b to 0
Throttle 2: from 0 to b
from a to 0
Internal contol oil flow
External control oil return
Schema:
Control type: 17
Internal contol oil flow
External control oil return
Comment: control type versions see type key
4/2-
Control
valve
020
4/2-
Control
valve
019
4/3-
Control
valve
008
4/3-
Control
valve
008
4/3-
Control
valve
008
detailed symbol simple symbol
57501298.06.12.08 Design subject to chenge without notice
Ordering Example of order
The units are designated by their type number. Thecomposition of this number can be drawn from the typecode. The standard versions are listed in the typesurvey. When ordering any of the standard versions,please state type number as well as catalog number topreclude possible misinterpretations.When inquiring about ordering units not listed in ourtype survey of thid publication, the type number by youby means of the type code, however, will do. Thecorresponding catalog number will be than stated in ourconfirmation order.Flange valves are provided with O-rings. Subplate andmounting screws must be ordered seperately.
4/3-way NG 25 directional valve, pilot operated;DC 24 V, Electrical connection: Connector on solenoid,symbol 008, internal control oil flow, external control oilreturn, with G 1 1/4" subplate.
Directional control valve:Type description: S 25 VH 17 10 G 008 001 2 O OOrder No.: 5203674.7234
Subplate:Type description: P S 25 G 7 001 2 O OOrder No.: 1065189
Type survey (standard versions
1) Symbols are shown iin operation type: electro-hydraulicwith control type: 17
Sym
bol N
o.
Overlap
Acta
tion
Contr
ol m
ode
Voltage
1) Simplified main
and pilot valve
symbol
Ele
ctr
ical
connection
Lin
e c
on
-
nection
Type Cat No.:
Valve Solenoid
020
17 10
10
10
10
10
10
10
10
10
10
19
17
19
17
19
17
19
17
19
+
019 +
008 +
009 +
013 -
∼
S 25 VH 17 10 G 020 001 2 O OS 25 VH 17 11 G 020 001 2 O O
5203666.72345203667.7234
Pilo
t valv
e:
sole
noid
opera
tion,
pre
ssure
seale
dM
ain
valv
e:
hydra
ulic
Subpla
te:
G 1
Type:
PS
25 G
6 0
01 2
O O
ord
er
no. 1065188
G 1
1/4
Type:
PS
25 G
7 0
01 2
O O
ord
er
no. 1065189
G 1
1/2
Type:
PS
25 G
8 0
01 2
O O
ord
er
no. 1065190
S 25 VH 19 10 G 020 001 2 O OS 25 VH 19 11 G 020 001 2 O O
5203668.72345203669.7234
S 25 VH 17 10 G 019 001 2 M OS 25 VH 17 11 G 019 001 2 M O
5203670.72345204046.7234
S 25 VH 19 10 G 019 001 2 M OS 25 VH 19 11 G 019 001 2 M O
5203672.72345204047.7234
S 25 VH 17 10 G 008 001 2 O OS 25 VH 17 11 G 008 001 2 O O
5203674.72345203675.7234
S 25 VH 19 10 G 008 001 2 O OS 25 VH 19 11 G 008 001 2 O O
5203676.72345203677.7234
S 25 VH 17 10 G 009 001 2 O OS 25 VH 17 11 G 009 001 2 O O
5203678.72345203679.7234
S 25 VH 19 10 G 009 001 2 O OS 25 VH 19 11 G 009 001 2 O O
5203680.72345203681.7234
S 25 VH 17 10 G 013 001 2 R OS 25 VH 17 11 G 013 001 2 R O
5203682.72345203683.7234
S 25 VH 19 10 G 013 001 2 R OS 25 VH 19 11 G 013 001 2 R O
5203684.72345203685.7234
∼
∼
∼
∼
∼
∼
∼
∼
∼
6 7501298.06.12.08Design subject to chenge without notice
Dimensional Drawings
Directional valve: See subplate dimensioned drawing for the dimensions of the connection layout.
Interface S25
DIN 24340 - A 25 and ISO
M 5x30 DIN 912 - 10.9
Tightening torque = 7.6 Nm
M 12x65 DIN 912 - 10.9
Tightening torque = 110 NmPilot valveS6
Main valveS25
El. connection11 and 13
Section A-B
Screw “t” not required for“internal control oil return“version
Screw “p” not required for“internal control oil feed“version
77501298.06.12.08 Design subject to chenge without notice
Dimensional Drawings
Switching times setby double throttlenon-return valveMU 2 S6 ...
Control type19, 20, 23, 24, 29
El. connection11 and 13
M 5x30 DIN 912 - 10.9
Tightening torque = 7.6 Nm
M 12x65 DIN 912 - 10.9
Tightening torque = 110 Nm
8 7501298.06.12.08Design subject to chenge without notice
Dimensional Drawings
Subplate with port arrangement according to DIN 24340-A 25 and ISO 4401-AE-08-4-AG 1 or G 1 1/4
Order no.
1065188
1065189
b1
114
121
b2
26
30
d1
G 1
G 11/4
d2
ø 47
ø 56
h1
19
21
l126
30
G 1 1/2
Cut-out for
connections in
control face
Section A-B
Cut-out for
connections in
control face
Section A-B
97501298.06.12.08 Design subject to chenge without notice
Spare Part Drawings
Pilot valve
S 6...
Main valve
S 25...
Subplate
Section C-D
Check valve cartridge
Oder no.: 0659642
Doppel-Drosselrück-
schlagventil
MU 2 S6 ...
Pilotventil
S 6...
Hauptventil
S 25...
Screw not required for “external
control oil feed“ versionScrew not required for “externalcontrol oil return“ version
Section A-B
M 12x65 DIN 912 - 10.9
Tightening torque = 110 Nm
Throttle 1 Throttle 2
El. connection11 and 13
M 5x70 DIN 912 - 10.9
Tightening torque = 7.6 Nm
10 7501298.06.12.08Design subject to chenge without notice
Spare Part Drawings
008, 009, 010, 011, 012, 013
005
Piston position for spring operation
and for spare parts in relationship to
symbol 020 (compression spring is not
required with symbol 019).
For replacement purchase of:
Directional control valve complete: See type key and order no. on name plate from main valve.
Pilot valve: See type key and order no. on name plate from pilot valve.
117501298.06.12.08 Design subject to chenge without notice
Description
O-ring (26.6 x 3.5)
O-ring (18.6 x 3.5)
O-ring (44.1 x 2.6)
O-ring (12.4 x 1.8)
Compression spring see “Piston stroke for spring operation“ spare part diagram
Plug screw1) Pilot valve complete
O-ring (9.25 x 1.78)
O-ring 16 x 2)
Connector A
Connector B
Double throttle non-return valve complete
O-ring (9.2 x 1.8)
Part
1
2
3
4
5
6
7
8
9
10
11
12
13
Individual Spare Parts
S 25 VH ... Order no.:
0701343
0701338
0701307
0701254
-
0701198
-
0701728
0661476
0657859
0570275
5400060
0701728
S 25 VH ...with double throttlenon-return valve
4
2
2
4
2
1
4
2
1
1
-
-
4
2
2
4
2
1
4
2
1
1
1
4
Socket head screws(M5 x 30 DIN 912-10.9)
4 4 0700387
Mounting screws S 6, Tightening torque = 7,6 Nm
-
Socket head screws(M12 x 65 DIN 912-10.9)
6 6 0700476
Mounting screws S 25, Tightening torque = 110 Nm
Spare part kitsOrder no.
-
1...4, 8...9
0727128
1...4, 8...9, 13
0727128 + 0616660 -
-1 Set of replacement wearing parts consistsof the following:
17500901.06.04.13
Directional control valves DN 16 indirectly actuated, spool type valveInterface to DIN 24 340 and ISO 4401
PN [pmax.] = 350 bar
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
Damped; facilitates smooth shifting partially throttled ensures smooth change over
Low volume design
High power density
Electrical, pneumatic and hydraulic operation
General parameters
Designation: Directional control valve
Symbol:See type key
Design: Spool-type valve
Type of mounting: Flange
Line connection: Subplate
Line connection:any
Weight of valve with: 1 actuator [kg]: 9.7 2 actuators [kg]: 10.3
Weight of subplate: G 3/4 [kg]: 9.0 G 1 [kg]: 9.0
Weight of non-return valve double-throttle [kg]: 1.7
Ambient temperature range Ju [°C]:-20 to +50
Size: DN 16
Technical data nach VDI 3267
Hydraulic parameters
Operating pressure p [bar]X = extern: 350at port P, A, B: X = intern: 350 at port T: X = extern: 350 Y = intern: 160
Control pressure pSt [bar] 2):1) 8,5 to 350
Control volume VSt [cm3]:Symbol 019, 020: 8.4Symbol 008, 009: 4.2 Symbol 013: 4.9
Pressure luid temperature Ju max. [°C]:+70
Viscosity range: n [mm2/s]:12 to 500
Flow Qmax [l/min]:See characteristic curves
Electrical parameters
Actuation: VH
Switching times 3) Pilotventil [ms]: te: 50 ta: 30
Number of switchings/h, approx.: 15000
Rated voltage connector input UN [V]: Standard voltages: 24 DC 230 AC 40...60 Hz +5%/-10% +5%/-10%
Special voltages on request
Power consumption P20 [W]: 31
Duty cycle [%]:100
Degree of protection for solenoid and electrical connection to DIN 40050: IP 65
Electrical connection: See type key
1) VSt min 10 bar for symbol 0132) For symbols 011 and 013 the control
pressure is achieved by the precharge cartridge valve in P.
3) The main valve switching time is dependant on the control oil supply.
2
Directional control valves DN 16
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7500901.06.04.13
Type survey (standard versions)
1) Simpliied main and pilot valve symbol
Symbol-No. Overlap Voltage Type Cat. No.
020 + VDC 24VVAC 230
VDC 24VVAC 230
S 16 VH 17 10 G 020 001 6 O OS 16 VH 17 11 G 020 001 6 O O
S 16 VH 19 10 G 020 001 6 O OS 16 VH 19 11 G 020 001 6 O O
5205590.7234.024005205591.7234.20500
0505592.7234.024005205593.7234.20500
019 + VDC 24VVAC 230
VDC 24VVAC 230
S 16 VH 17 10 G 019 001 6 M O S 16 VH 17 11 G 019 001 6 M O
S 16 VH 19 10 G 019 001 6 M OS 16 VH 19 11 G 019 001 6 M O
5205594.7234.024005205595.7234.20500
5205596.7234.024005205597.7234.20500
008 + VDC 24VVAC 230
VDC 24VVAC 230
S 16 VH 17 10 G 008 001 6 O OS 16 VH 17 11 G 008 001 6 O O
S 16 VH 19 10 G 008 001 6 O OS 16 VH 19 11 G 008 001 6 O O
5205598.7234.024005205599.7234.20500
5205601.7234.024005205602.7234.20500
009 + VDC 24VVAC 230
VDC 24VVAC 230
S 16 VH 17 10 G 009 001 6 O O S 16 VH 17 11 G 009 001 6 O O
S 16 VH 19 10 G 009 001 6 O OS 16 VH 19 11 G 009 001 6 O O
5205603.7234.024005205604.7234.20500
5205605.7234.024005205606.7234.20500
013 - VDC 24VVAC 230
VDC 24VVAC 230
S 16 VH 17 10 G 013 001 6 R OS 16 VH 17 11 G 013 001 6 R O
S 16 VH 19 10 G 013 001 6 R OS 16 VH 19 11 G 013 001 6 R O
5205607.7234.024005205608.7234.20500
5205609.7234.024005205610.7234.20500
1) Symbols are shown in operation type: electro-hydraulic with control type: 17
Connecting plate
Type Cat. No.
G 3/4 P S 16 G 5 001 2 O O 1065186
G 1 P S 16 G 6 001 2 O O 1065187
Ordering
The units are designated by their type number. The composition of this number can be drawn from the type code. The standard ver- sions are listed in the type survey. When ordering any of the stan- dard versions, please state type number as well as catalog number to preclude possible misinterpretations.Further valve versions can be composed via combination of types - order numbers on request.
Flanged valves are provided with O-rings and mounting screws. Subplate must be ordered separately.
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7500901.06.04.13 3
Directional control valves DN 16
Type key
Directional control valve
1 Actuation: VH – DC-type solenoid, pressure-tight, with manual override
Y – Hydraulic
2 Control type:
Subplate
P S 16 G ... 001 ... O O
1 2
1 Line connection: 5 – G 3/4 (internal thread 6 – G 1 to DIN ISO 228/1)
2 Engineering version: 2
For the symbols shown: Solenoid operated valve with control pattern 171) Locking not possible with hydraulic and direct pneumatic operation.2) Control patterns 17, 19, 21 and 23 are only possible in conjunction with
symbol 013 with a precharge cartridge valve in P.
Pilot Control oil- Control oil- Timed inlet X outlet Y settings
17- S 6 internal external none18- S 6 external external none19- S 6 internal external available20- S 6 external external available21- S 6 internal internal none22- S 6 external internal none23- S 6 internal internal available24- S 6 external internal available28- - external external 1) none29- - external external 1) available
with timed settings: double-throttle non-return valve is available for hydraulic directly operated valves as an intermediate plate
1) Y = control oil supply
3 Electrical connection:
00- Operation without electrical connection
10- PG 11 socket according to DIN 43650 mounted on solenoid
11- PG 11 socket according to DIN 43650 mounted on solenoid with integrated rectiier
12- PG 11 socket according to DIN 43650 mounted on solenoid with integrated rectiier signal indicator mounted on socket
13- PG11 socket according to DIN 43650 mounted on solenoid, signal indicator mounted on socket
S 16 ... ... ... G ... 0016 ... ...
1 2 3 4 5 6
Symbol Symbol No.
Overlap
020 +
019 1) +
008 +
009 +
013 2) -
4 Symbol:
5 Additional data: O – Standard design M – mechanical detend of the
pilot valve R – Pilot cartridge in port P 2)
(main valve)
6 Sealing material: O – Perbunan V – Viton
4
Directional control valves DN 16
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7500901.06.04.13
Ordering example
Directional control valve:Type No.:S 16 VH 17 11 G 008 001 6 O OCat. No.:5205599.7234.20500
Directional control valve:Type No.:S 16 VH 17 10 G 008 001 6 O OCat. No.:5205598.7234.02400
4/3-way NG 16 directional valve, pilot operated; AC 230V 50 Hz, Electrical connection: Connector with rectiier on solenoid, symbol 008, internal control oil low, external control oil return, with G 3/4" subplate.
4/3-way NG 16 directional valve, pilot opersted; DC 24V; Electrical connection: Connector with rectiier on solenoid, symbol 008, internal control oil low, external control oil return, with G 3/4" subplate.
Design Actuation Mounting Line connection
Pilot operated valves are preferably operated by solenoids. The auxiliary manual operation is only effec- tive when control pressure is available. Directly opera- ted versions are available for hydraulic and pneumatic operation.
The S 16 type valves are spool type valves available in 4/2- and 4/3-way designs. The valves can be used as 2- or 3-way designs by closing the appropriate ports.
The units are bolted on sub- plates and sealed by O-rings.
Subplate, interface to DIN 24 340-A16 and ISO 4401-AD-07-4-A.
Subplate:Type No.:P S 16 G 5 001 2 O OCat. No.:1065186
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7500901.06.04.13 5
Directional control valves DN 16
Control modes
Control type: 17
Internal control oil feed:Port “X“ in subplate closed. Port “p“ in main valve opened.
External control oil feed:Connector for control oil return in “Y“ in subplate. Port “t“ in main valve closed.
Control type: 18
External control oil feed:Connector for control oil in “X“ in subplate. Port “p“ in main valve closed.
External control oil return:Connector for control oil return in “Y“ in subplate. Port “t“ in main valve closed.
Control type: 19
Switching time settings:The switching times of the main valve can be inluenced by a double throttle non-return valve, which throttles the control oil supply.
The switching times are changed with the following settings:Throttle 1: from 0 to a
from b to 0Throttle 2: from 0 to b
from a to 0Internal control oil low External control oil return
Control type: 28
Direct hydraulic operation. Control oil feed “X“ and “Y“ in the subplate.
4/2- Control valve 020
4/2- Control valve 019
4/3- Control valve 008
4/3- Directional control valve 008
4/3- Control valve 008
4/2- Control valve 020
detailed symbol simple symbol
6
Directional control valves DN 16
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7500901.06.04.13
Dimensional drawings
Directional valve: See subplate dimensioned drawing for the dimensions of the connection layout.
Pilot valve in connection P (depends on symbol and control type)
Interface S 16DIN 24340 - A 16 / ISO 4401
Tightening torque:
M 15 DIN 912 - 10.9 = 7.6 NmM 16 DIN 912 - 10.9 = 13 NmM 10 DIN 912 - 10.9 = 62 Nm
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7500901.06.04.13 7
Directional control valves DN 16
Dimensional drawings
Switching times set by double throttle non-return valve MU 2 S6 ...
Control type 19, 20, 23, 24, 29
8
Directional control valves DN 16
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7500901.06.04.13
Dimensional drawings
Subplate with interface according to DIN 24 340-A 16 and ISO 4401-AD-07-4-A
Cat. No. a b c
10 651 86 G 3/4 ø 41 16.5
10 651 81 G 1 ø 47 18.5
Aperture for connection in control panel
Connection “L“ is only required for valves with switching speed monitoring which are available on request.
Section A-B
8 depth
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7500901.06.04.13 9
Directional control valves DN 16
Characteristic curves
Symbol P-A P-B A-T B-T P-T
020, 019, 008 5 5 5 4 -
013 1 2 3 5 4
009 2 3 3 5 -
10
Directional control valves DN 16
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7500901.06.04.13
Spare parts drawings
Pilot valve
Double throttle non-return valve MU 2 S6 ...
Main valve
Pilot valveS 6 ...
Main valveS 16 ...
Subplate
Part section A-B Part section C-D
Screw not required for “external control oil feed“ version
Electrical connection11 and 13
M 5x70 DIN 912 - 10.9 Tightening torque = 7.6 Nm
Throttle 1 Throttle 2
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7500901.06.04.13 11
Directional control valves DN 16
Spare parts drawings
Part Description S 16 VH S 16 ...
S 16 VH ... S 16 ... with double throttle non-return valve
S 16 Y 2800 Cat. No.
1 O-ring (21.9 x 2.62) 4 4 4 0701292
2 O-ring (10 x 2) 2 2 2 0659116
10 1) Pilot valve complete
11 Double throttle non-return valve complete - 1 - 1065506
11 Connecting valve plate complete - - 1 (P>B) (A>T) 2840093
Spare parts (pieces)
1) Pilot valve complete For 2-position valves with spring = 1 off or S6VH10G0200011OV 5203541.7234.024 return 1 off S6SH11G0200011OV 5204082.7234.209
For 2-position valves with = 1 off or S6VH10G0190011MV 5203942.7234.024 ocking 1 off S6VH11G0190011MV 5204089.7234.205
For 3-position valves with spring = 1 off or S6VH10G0090011OV 5203940.7234.024 return to central 0 position 1 off S6SH11G0090011OV 5204093.7234.203
See 7501292 for spare parts for NG 6 pilot valve.
12
Directional control valves DN 16
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the speciications given in this document.
7500901.06.04.13
HERION Systemtechnik GmbHUntere Talstraße 6571263 Weil der StadtTel.: +49 (0) 7033/3018-0Fax: +49 (0) 7033/3018-10info@herion-systemtechnik.dewww.herion-systemtechnik.de
A subsidiary of the Norgren and IMI group of companies
Distribution and Service
• in 75 countries through the Norgren service network
HERION SystemtechnikSales Partners
ChinaESTUN INDUSTRIAL AUTOMATION CO., LTS155,Jiangjun Road, Jiangning Economical & TechnicalDevelopment Zone, Nanjing, 211100 P.R.C.Tel.: +86-25-52785915E-Mail: info@estun.comwww.estun.com
JapanRiken Optech Corporation2-6-9, Higashi Ohi, Shinagawa-ku,Tokyo 140-8533Tel.: +81 3 34748602E-Mail: contact@rikenoptech.comwww.rikenoptech.com
KoreaCHUNGWOO CO., LTD.# 416-4 DokjeongriJanganmyun HwaseongsiKyungkido, KoreaTel.: +82 (0)31 351-5340E-Mail: blueox2@unitel.co.krwww.chungwooco.co.kr
SpainEUROTECH SYSTEMS, S.L.Av. Can LLuch, 2508690 SANTA COLOMA DE CERVELLOTel: +34 93 634 0101E-Mail: eurotech@eurotechsys.comwww.eurotechsys.com
South AfricaErnest Lowe ELCOPneumatic & Hydraulic Automation Solutions6, Skew Road, Boksburg North 1459,Gauteng, South AfricaTel.: +27 (11) 898-6600E-Mail: corporate@elco.co.zawww.elco.co.za
TaiwanFull Life Trading Co., Ltd.16F-4, No.2, Jian Ba Rd. Chung Ho CityTaipei County, Taiwan 23562Tel.: +886-2-82261860E-Mail: sales-dept@fulllifetrading.comwww.fulllifetrading.com
TurkeyPower Pnomatik Proses A. SNecatibey Cad. No:44/2KaraköyÝstanbul 34420Tel.: +90 212 2938870E-Mail: info@powerpnomatik.comwww.powerpnomatik.com