DG60MI-400The unit has two fuel filtration; one is a fuel filter and the other is a water...

Post on 07-Oct-2020

2 views 0 download

Transcript of DG60MI-400The unit has two fuel filtration; one is a fuel filter and the other is a water...

Specifications

2015© Yamabiko Corporation All rights reserved35 Shin-Ujiagmi, Kita-Hiroshima-Cho, Yamagata-Gun, Hiroshima 731-1597 Japan

http://www.yamabiko-corp.co.jp/shindaiwa_global/ipe/E170309

Diesel Engine Driven Generator DG60MI-400

DG60MI-400

GENERATOR

50

Revolving magnetic field, Brushless 3-Phase Synchronous

400 [200]

3-Phase, 4-Wire

F

Self-Excitation (Brushless)

80

4

Generator Type

Rated Frequency

Rated Output

Rated Voltage

Winding

Power Factor

Insulation Class

Excitation

Number of Poles

BB-4BG1T(ISUZU)4、105(bore) x 125(stroke)mm

Vertical Water-Cooled 4-Cycle Diesel Engine

48.3

Types

Model

Continuous Rated Output

Rated Speed

4.329

Combustion System95D31RBattery

Number of Cylinders

ENGINE

15.4Cooling Water Volume

14.3Lubricant Volume

Diesel Fuel

CD Class

125

Fuel

Lubricant Oil

Fuel Tank Capacity

Full Forced Pressure Feed Type

Electric Start

Lubricating Method

Starting Method

RadiatorCooling Method

UNIT

1320Installed Weight880

1240

1180

Width

Height

Dry Weight2090Length

60

60

Hz

kVA

V

kW 40 48

440 [220]

57.8

18001500min-1

kW

Displacement L

Direct Fuel Injection with Turbo Charger

L

L

50

mm

mm

mm

kg

kg

59*Sound Level@7m distance/No load

dB(A)

Fuel Consumption@3/4 load

L/Hr 8.7*

62*

50Hz60Hz

50Hz60Hz 10.7*

Powered by

*Reference value

*Reference value

2015© Yamabiko Corporation All rights reserved35 Shin-Ujiagmi, Kita-Hiroshima-Cho, Yamagata-Gun, Hiroshima 731-1597 Japan

http://www.yamabiko-corp.co.jp/shindaiwa_global/ipe/

DG60MI−400Control Panel

10. 400/440V Output Lamp

2. Pilot Lamp 3. Earth Leakage Relay 4. Warning Indicators 5. Voltmeter6. Ammeter 7. Frequency Meter8. Circuit Breaker 9. Fuel Gauge

14. Voltage Regulator

16. Starter Switch15. Ammeter Selector

1. Hour Meter

11. Over Load Precaution Lamp 12. Preheat Lamp 13. Water Temperature Gauge

1 2

6

1110

3

5

4

78

9 12

13 14 15 16

FeaturesOver Load Precaution LampDouble Fuel Filtration System

The lamp starts to flash if the output current exceeds 80% of the rated current.

The unit has two fuel filtration; one is a fuel filter and the other isa water separator with enhanced water filtration capability. Elimination of debris such as water, sand, and dust is ensured by double fuel filtration system, and reduces maintenance frequency.

Reliable ISUZU EngineDG60MI-400 is equipped with ISUZU BB4B1T.As ISUZU service network covers the world, it offers extensive services, periodical inspection, and repair.

Diesel Engine Driven Generator

Theft ProtectionSimple Control Panel

Every door can be locked.

As the functions are limited to the minimum necessary levels, arrangement of the control panel is simplified, thereby reducing the risk of an improper operation.

Socket for Industrial UseSocket for industrial use (IP44)*1 , widely used at job site, is equipped as standard. It is ready-to-use for “turn-key” operation. *1 3-Phase round 4 pins(32A)x1  1-Phase round 3 pins (15A) x2

1718

17. Throttle Lever18. Frequency Adjusting Screw

Water Separator

Fuel Filter