Demystifying Testing Standards C t B ildi F dCommon to Building Facades

John Runkle, P.E.

Director Forensic ServicesDirector, Forensic Services

Architectural Testing, Inc. Architectural Testing

Learning Objectives

• Understand laboratory and field test standards related to building envelope performance.related to building envelope performance.

• Identify and manage risks that could impact the test results.

• Learn the benefits and limitations of laboratory testing with respect to actual field performance.

D l d t di f h t l t th b t• Develop an understanding of how to select the best performance predictors for future projects.

2

Function of Facades• Aesthetically pleasing• Provide environmental separationp

– Air Barrier– Vapor Barrier– Drainage Layer– Thermal Layer– Acoustical BoundaryAcoustical Boundary– Withstand Structural

Loads

Façade Aesthetics Testing

3

ASTM G 155

4

ASTM D 2244Standard Test Method for Calculation of Color Differences from Instrumentally Measured Color Coordinates

ASTM C 1185

5

Façade Air Leakage Testing

ASTM E 2178

6

ASTM E 2357 AssemblyASTM E 2357 Assembly

Post Applied Brick Ties

7

© Retro-Specs Consultants

ASTM E 1186

8

ASTM E 1186

ASTM

E 1186

9

ASTM E 1186

ASTM E 1186

10

11

12

13

14

15

© Retro-Specs Consultants

ASTM E 779

16

ASTM E 1186

AAMA 101 Testing

17

ASTM E 283

ASTM E 783

18

ASTM E 783

ASTM E 783

19

Problem - Extraneous Air Flow

Continuous mullions in a curtain wall

SolutionSeal off any areas that are not intended to be included in the test with spray foam, p yduct tape, butyl tape, plastic, or sealant.

20

Problem - Qualitative or Quantitative Test Method?

SolutionCustomize testing protocol to meet the project budget and project team needs.p j g p j

21

Problem – Limited access Limited budget

SolutionConsider infra-red thermography

Discontinuous air barrier at roof soffit allowing escape of warm, moist air from natatorium

22

Façade Water Testing

AAMA 101 Testing

23

ASTM E 331

ASTM E 547

24

AAMA 501.1

AAMA 501.1

25

AAMA 501.1

AAMA 501.2

26

Problem - Lack of Access -Exterior

• Tare Applicationpp

• Specimen Inspection

• Spray Rack

Attachment

Solutions

• Excluding tare is acceptable if total air flow is equal to or less than window allowable flow, qelse interior tare is an option.

• Mirrors are an option if specimen contains operable windows.

• Hanging a spray rack carefully from an openHanging a spray rack carefully from an open area above specimen.

27

Solutions

Static vs. dynamic differential pressurep

28

Static or Dynamic Pressure Differential?

Static Air Pressure Differential?

29

Static Air Pressure Differential

Section at window sill

Dynamic Air Pressure Differential?

AAMA 501.1

30

Dynamic Air Pressure Differential

Section at window sill

Interior or Exterior Chamber?

Brick Mass Wall

31

Brick Mass Wall

Vacuum

Brick Veneer Cavity Wall

32

Brick Veneer Cavity Wall

Vacuum

33

Problem – Inadequate Water Pressure

Solutions

34

Problem: Definition of Water Leakage

35

Water penetration within innermost plane passing per AAMA 502-02, 502-08; however, failing the less than ½ ounce requirement per AAMA 503-03

ASTM E 2273

36

ASTM C 1715

Test DurationIf possible, complete test to identify all leaks

Leak #1 Leak #4

Leak #2Leak #3

37

Test Duration?

38

How long would you test these substrates?

39

NFRC 102 / AAMA 1503

NFRC 102 / AAMA 1503

40

Condensation Resistance

41

AAMA 501.5

AAMA 501.5

42

CondensationResistanceResistance

CondensationResistance

43

44

NFRC 100 (U-factor), 200 (SHGC), 500 (CRF)

45

FAÇADE ACOUSTICAL TESTING

46

ASTM E 90

Acoustical Testing

47

Outdoor SPL Measurements

ASTM E 966

48

Façade Structural Testing

ASTM E 330Structural Loading

49

Miami, Dade Co nt FLCounty – FL

Product Approval

50

D.O.D.

51

ASTM D 4541, ASTM E 488

52

53

Is Tomorrow’s Mold … Energy?

Façade Energy Components

• U-Factor

• Air Infiltration

• Solar Heat Gain

54

Solar Heat Gain

SHGCT ittTransmittanceReflectanceAbsorbtanceEmittance

Existing/Original Window and Facade

55

Cold Chamber

Typical Cold Chamber Set-up

56

Existing/Original Window and Interior

Warm Chamber with Controls

57

New Window

New Window, Sealants, and Flashing

58

Cold Chamber

Typical Cold Chamber Set-up

59

New Window and Interior Sealant

Warm Chamber with Controls

60

Field U-factor Tests Results

U-factor Original

U-factorReplacement

Difference in U-factor

Calculating Energy Savings

SHGC Air LeakageU-factor

Energy Savings or Loss

61

Questions?Questions?

Comments?

Insults?

John Runkle, P.E.Architectural Testing, Inc.jrunkle@archtest.com

Façade Material Property Testing

62

ASTM D 4114

Durability / Design Life

63

Durability / Design Life

Durability / Design Life

64

ASTM E 576

65

66