Data_sheet_NL_50_125-2%2c2-2-05

Post on 18-Jan-2016

1 views 0 download

description

pump selection

Transcript of Data_sheet_NL_50_125-2%2c2-2-05

  • 73,9%

    71,4%73%

    Eff. 76,9%

    75,3%

    67,9%

    Application range

    Head

    Shaft power P2

    NPSH-values

    Hydraulic efficiency

    H / ft

    0

    10

    20

    30

    40

    50

    60

    70

    p / psi

    0

    5

    10

    15

    20

    25

    30

    P / hp

    2

    NPSH / ft

    10

    Q / US g.p.m.0 40 80 120 160 200 240

    / %

    0

    40

    - 5,512

    - 5,118

    - 4,724

    - 4,331

    - 3,937

    - 4,567 A1

    50 21,37

    1,987

    4,011

    110

    68,94

    Duty chart Single head pump

    248 F-4 F

    Information for order placements

    Port to Port

    Motor protection

    Efficiency

    IE2Motor efficiency level

    Minimum Efficiency Index (MEI)

    Fluid temperature

    Max. operating pressure

    0,83Power factor

    FInsulation class

    4,01 ftNPSH

    4109040

    2,95 hp

    68,94 %

    1,99 hp

    IP 55

    4,58 A

    207,2 lb

    50,00 ft

    110,00 US g.p.m.

    0,00 ft/s

    61,54 lb/ft

    131,00 F

    Water

    50,00 ft

    110,00 US g.p.m.

    Materials

    Weight approx.

    Pipe connection on the pressure side

    Pipe connection on the suction side

    Fitting dimensions

    Permitted voltage tolerance

    Degree of protection

    Rated current

    Mains connection

    Max. speed

    Rated power P2

    Motordata per Motor/Pump

    Max. environmental temperature

    Item number

    NL 50/125-2,2-2-05

    Glanded standard pump

    Product data

    Hydraulic efficiency

    Shaft power P2

    Head

    Flow

    Hydraulic data (Duty point)

    Kin. viscosity

    Density

    Fluid temperature

    Media

    Head

    Flow

    Requested data

    +

    AQ1EGG

    X30Cr13

    EN-GJL-250

    EN-GJL-250

    EN-GJL-250

    Lantern

    Mechanical seal

    Pump shaft

    Impeller

    Pump housing

    50% / 75% / 100%

    232,1 psi

    2900 rpm

    ...

    Impeller size 4,567

    A 3 15/16 H3 8 7/16 L3 124 5/8

    B2 14 3/16 H4 14 3/4 L4 33 11/16

    B3 12 5/8 L 306 7/8 S4 3/4

    DN1 2 9/16 L1 32 11/16 S1 6 11/16

    DN2 1 15/16 L2 5 11/16 X 1/8

    0.40

    10 %

    yes

    3~ 400 V / 50 Hz

    DN 65, PN 16

    DN 50, PN 16

    104 F

    Dimensions inch

    80,5 %/ 82,9 %/ 83,2 %

    Glanded standard pump

    Technical data

    NL 50/125-2,2-2-05

    Project name

    Project ID

    Installation location

    Untitled project 2015-02-25 12:25:22.999

    2015-02-25Date

    Contact

    Contact

    Phone

    E-mail

    Phone

    E-mail

    Customer

    Subject to change 1 / 1Pages

    Software version 4.1.5 - 2015/02/19 (Build 772)

    Data version 23.01.2015

  • Water (100%); 131 F; 61,54 lb/ft; 5,455E-6 ft/sPower data referred to:

    Operating data

    73,9%

    71,4%

    73%

    Eff. 76,9%

    75,3%

    67,9%

    Application range

    Head

    Shaft power P2

    NPSH-values

    Hydraulic efficiency

    H / ft

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    50

    55

    60

    65

    70

    75

    80

    p / psi

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    P / hp

    1

    2

    3

    4

    5

    NPSH / ft

    4

    8

    12

    16

    20

    Q / US g.p.m.0 20 40 60 80 100 120 140 160 180 200 220 240 260 280

    / %

    0

    10

    20

    30

    40

    50

    60

    - 5,512

    - 5,118

    - 4,724

    - 4,331

    - 3,937

    - 4,567

    A1

    50 21,37

    1,987

    4,011

    110

    68,94

    Speed

    2900 rpm

    Frequency Duty point Suction port Discharge port

    50 Hz Q = 110,00 US g.p.m. 50,00 ftH = DN 50DN 65

    Glanded standard pump

    Hydraulic data

    NL 50/125-2,2-2-05

    Project name

    Project ID

    Installation location

    Untitled project 2015-02-25 12:25:22.999

    2015-02-25Date

    Contact

    Contact

    Phone

    E-mail

    Phone

    E-mail

    Customer

    Subject to change 1 / 1Pages

    Software version 4.1.5 - 2015/02/19 (Build 772)

    Data version 23.01.2015

  • Standard

    Suction side

    Discharge side

    Dimensions inch

    A 3 15/16 L1 32 11/16

    B2 14 3/16 L2 5 11/16

    B3 12 5/8 L3 124 5/8

    DN1 2 9/16 L4 33 11/16

    DN2 1 15/16 S4 3/4

    H3 8 7/16 S1 6 11/16

    H4 14 3/4 X 1/8

    L 306 7/8

    DN 65, PN 16

    DN 50, PN 16

    2015-02-25Date

    Contact

    Contact

    Phone

    E-mail

    Phone

    E-mail

    Customer

    Subject to change 1 / 1Pages

    Software version 4.1.5 - 2015/02/19 (Build 772)

    Data version 23.01.2015

    Glanded standard pump

    Dimensions

    NL 50/125-2,2-2-05

    Project name

    Project ID

    Installation location

    Untitled project 2015-02-25 12:25:22.999