D etector of the reactor A nti N eutrino based on S olid-state plastic S cintillator (DANSS)

Post on 24-Feb-2016

28 views 0 download

Tags:

description

Inaugural Conference of ICISE “Windows on the Universe” Quy Nhon 13/08/2013. Sensitivity of the DANSS detector to short range neutrino oscillations. M.Danilov Representing the DANSS Collaboration (ITEP (Moscow) & JINR(Dubna)). - PowerPoint PPT Presentation

Transcript of D etector of the reactor A nti N eutrino based on S olid-state plastic S cintillator (DANSS)

Detector of the reactor AntiNeutrino based on Solid-state plastic Scintillator

(DANSS)

M.Danilov

Representing the DANSS Collaboration (ITEP (Moscow) & JINR(Dubna))

Inaugural Conference of ICISE“Windows on the Universe”Quy Nhon 13/08/2013

Sensitivity of the DANSS detector to short range neutrino oscillations

There are several ~3σ indications of 4th neutrino

LSND, MiniBoone: νe appearanceSAGE and GALEX νe deficitReactor νe deficit

Indication of a sterile neutrino Δm2 ~ 1 eV2

Sin22θ14 ~ 0.17=> Short range neutrino oscillations

DANSS Goals

Cosmic muon veto (PS plates)

Sensitive volume ~ 1m3

(2500 PS strips)

Cu frames (inner partof passive -shielding)

Pb (external part of passive -shielding)

CH2 + B (n-shielding)

Reactor monitoring using neutrinos: 1. to measure the thermal reactor power with accuracy of 1.5% per day; 2. to define the fuel composition and amount of the produced 239Pu with accuracy of 6% in 10 days of measurements;

Search for short range neutrino oscillations

DANSS Parameters:IBD detection efficiency ~70%

ν counting rate up to 10000/day

Background rate ~1%

Distance to reactor core(center to center) 9.7-12.2m (change in 5min)

Energy resolution ~20% at 1MeV

Total weight – 13t + lifting gear

PMT

PMT

64 W LS fibers

X-ModuleY-Module

32 MPPC

64 W LS fibers

32 MPPC

0.15 0.30

40

1000

10

Each scintillator strip is read out individually by a Silicon Photo Multiplier (SiPM) via a WLS fiber.Sensitivity is ~15 p.e./MeVLight attenuation ~20%/m

• 50 strips are combined into a Module which is also read out by a small PMT (via 2 additional WLS fibers per strip).Sensitivity is ~10 p.e./MeV

• The frame of a Module is made of radio-pure electrolytic copper and thus shields the sensitive part against insufficiently pure components of front-end electronics placed outside the frame.

Gd-containinglight-reflecting

coating~6mg/cm2

glueWLS--fiber○1.2 mm

PS

X-plane

Y-planeCopperframes

View of a Module (under construction).

DANSS Design

SiPMs (CPTA, Moscow)

Handling is much safer (non-flammable, non-caustic) Þ no restrictions to move the detector very close to the reactor core Þ higher neutrino flux => better sensitivity.

High segmentation (2500 strips) => space information Þ better IBD signature => stronger BG suppression.Þ possibility of continuose calibration with cosmics for every strip PS is not doped with Gd, but interleaved with it Þ better stability of the scintillator.

Dual readout with SiPM and usual PMT => better control of systematic

Detector on movable platform under reactor => better control of systematic low cosmic background

DANSS advantages

DANSS disadvantagesWorse energy resolution in comparison with liquid scintillator

Relatively large number of readout channels

0.0

6.6

10.7

19.6

h

Reservoirs withTechnological liquids~ 60 mwe

Core:h =3.5m = 3.12m

DANSS on a movableplatform with a lifting gearDetector distance from reactor core 9.7-12.2 m(center to center)

Typical reactor buildingwith WWER-10003 GW thermal power238U + (3.5-5)% 235U5*1013 ν/s/cm2 @10m

DANSS position under WWER-1000 reactor at Kalinin NPP

Calibration r/a source:

60Co 22Na 137Cs

248Cm ~3 n

A small prototype - “DANSSino”

50+50=100 strips20 cm 20 cm 100 cm1/25 of the DANSS40 kg (movable)2 PMT (X odd, Y even) No SiPM readout

Purpose:• Study of background

conditions• Tests of shielding efficiency • Measurements of trigger

rates

0 50 100 150 200 250 300 350 400 450 500 550 6000

100

200

300

400

500

Cs13722 Na

60 Co

BG Detected Energy [QDC-channels]

Arb.u.

Properties:ν p e+ n (Inverse Beta Decay) Efficiency e+ (Prompt) - 47% (E>1MeV) Efficiency n (Delayed) – 28% (E>1 MeV)

Background under reactor is order of magnitude lower than on surface

Heavy material shielding increases muon induced IBD background (and IBD detection efficiency)

Reactor power

Reactor power

Rate of neutrino-like events detected per day

Rate of neutrino-like events detected per day

Clear correlation between reactor power and DANSSino counting rate

Raw counting rates during reactor ON and OFF periodsNo change inside shielding!

Thermal neutrons inside shielding

(Hz)

Spectrum simulated for

235U fission

Background subtracted rate of neutrino-like events / 0.5 MeV / day

EnergyMeV

Neutrino rate ~ MC expectations

0 5 10 15 20 25 30 35

2

3

456789

2

3

456

1

10

True IBD

Random -n

-induced

248Cm

Delayed signal time distribution for different types of events

T μsec

Comparison of counting rates for reactor On and OFF periods for different selection criteria

Evidence for neutrino detection (~70/day) with S/B~ 1

DANSSino confirmed DANSS design parameters Reliable estimates of DANSS sensitivity

The role of the source dimensions

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 300.83

0.84

0.85

0.86

0.87

0.88

0.89

0.90

0.91

0.92

0.93

0.94

0.95

0.96

0.97

0.98

0.99

1.00

Ep = 3.5-4.5 M eV

Reactor - Detector distance [m]

Point-like reactor

Flat-burning reactorReal reactor ВВЭР-1000 (h=3.50 m d=3.12 m)

Δm2 = 2 eV2

Sin22θ14 = 0.17

Large size of reactor core smears oscillationsbut not too much!

Ratio of positron spectra at 11m and 9.7m for Δm2 =2eV2, Sin22θ14=0.2 (errors correspond to 8 months of running)

R

E [MeV]

Distortions are perfectly seen

ВВЭР-1000

СМ-3 Small core100MW Reactor

Sensitivity estimates (shape only) for 1 year (without systematics)

Most interesting parameter space is well covered

Summary

Details can be found in arXiv:1305.3350 [physics.ins-det]

High granularity, good stability, very low background, high neutrino flux and changeable distance to reactor coreshould allow DANSS to study the most interesting parameter region ofpossible oscillations to the 4th neutrino.

DANSS design parameters have been confirmed by the DANSSino results

In spite of a small size (4% of DANSS), non perfect shielding and μ vetoDANSSino detected about 70 events/day with S/B ~ 1.

DANSS data taking will start in 2014

Backup slides

Reactor - Detector distance [m]

Neutrino Intensity (relative to 1/R^2)

0.85

0.86

0.87

0.88

0.89

0.90

0.91

0.92

0.93

0.94

0.95

0.96

0.97

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30

Ep = 1.5-2.5 MeVEp = 2.5-3.5 MeVEp = 3.5-4.5 MeVEp = 4.5-5.5 MeV

Ep = 0.5-1.5 MeV

Energy of the positron detected:

MC example:

sin2(2θ) = 0.17

m2 = 2 eV2

0.87

0.88

0.89

0.90

0.91

0.92

0.93

9.8 10.0 10.2 10.4 10.6 10.8 11.0 11.2 11.4 11.6 11.8 12.0 12.2

Ep = 0.5-1.5 MeV

Ep = 1.5-2.5 MeVEp = 2.5-3.5 MeV

Ep = 3.5-4.5 MeV

Ep = 4.5-5.5 MeV

Reactor - Detector distance [m ]

close to the ce iling on the floor

Zoom of oscillation curves in the measured range