Post on 03-Jan-2016
description
Olympus NDT Canada 505, boul. du Parc-Technologique Tel. : (418) 872-1155 Québec (Québec) G1P 4S9 Fax. : (418) 872-5431 Canada Web site : www.olympusndt.com
EDDY CURRENT: ECT EXTENDED ASME CALIBRATION TUBE
RECOMMENDED CALIBRATION TUBES
The CT02 ECT calibration tube below provides every defect that is required to perform a good ECT calibration and build strong phase-to-depth curves. In fact, this tube is not only conforming to the ASME standards. In addition, it also provides wall thinning defects in order to help users to perform a more accurate calibration.
ARTIFICIAL DEFECT PARAMETERS IN FUNCTION OF TUBE WT AND OD
Defect Depth (%WT) Diameter Defect Depth (%WT) Diameter
GR10 10 % (internal) - H80 80 % 0.078”
GR20 20 % - H60 60% 0.125”
GR40 40 % - H40 40% 0.188”
GR60 60 % - H20 20% 0.188” (4 holes)
H100a Thru If OD>0.75”, 0.067” Else: 0.052”
H100b Thru If OD>0.75”, 0.125” Else: 0.078”
VARIABLE CHART IN FUNCTION OF TUBE OD
Variable Value
Variable Value
Variable Value
in mm in mm in mm
A 1.25” 32mm D 3.00” 76mm TL 20.50” 521mm
B 1.50” 38mm GLa 1/16” 1.6mm SP_OD OD + 3/4" OD + 19mm
C 3.50” 89mm GLb 1/2" 13mm SP_TCK 3/8” 10mm
GR10 GR20 H100a H80 H60 H40 H20 H100b GR40 GR60
SP01-XXX
GR10
(internal) GR20 H100a H80 H60 H40 H20 H100b GR40 GR60
DIFF (pits)
ABS (wall thinning)