ExpertiseIn this swiftly changing, technology driven industry, plenty of companies are forced
to react to remain relevant. At Geist, we stay ahead of our competition by constantly,
actively evolving to meet the demands of our customers. Through technical expertise
and skilled engineering, we provide leading-edge products and comprehensive
solutions for our trailblazing customers.
PartnershipTop to bottom at Geist, every employee is ready and eager to help solve our customers’
problems. Accessible and responsive, our team is committed to delivering exceptional
personal service and support every day — fulfi lling our mission of providing a premier
customer experience.
TailoredGeist has been customizing cost-effective solutions for clients for more than 60 years.
It’s part of our culture. Every customer offers unique challenges and opportunities. We
are committed to quickly meet each specifi c customer need with technological savvy
and unbeatable detail.
QualityWe are dedicated to developing the highest performing products and solutions in the
industry. From hand-soldered connections in our power strips, to enterprise level DCiM
systems, we consistently exceed our customer’s expectations.
Geist Americas
1821 Yolande AveLincoln, NE 68521 USA1.800.432.3219 or1.402.474.3400www.geistglobal.com
Geist DCiM2290 E Prospect Rd.Ft. Collins, CO 80525877.449.4150
Geist Europe
Unit 1, The Monarch Centre, Venture Way,Priorswood, Taunton,Somerset, TA2 8DE UK+44 (0) 1823 275100www.geisteurope.com
Geist Asia
ChinaTiley Plaza, Unit #2808,No. 195 Haide 3 RoadNanshan,ShenzhenGuangdong ProvinceP.R. ChinaPostal Code: 518000Tel: +86.755.86639505www.geistglobal.com
Geist Asia
Hong KongTel: +852 90361927Email: salesasia@geistglobal.comwww.geistglobal.com
800.432.3219 geistglobal.com
Containment – the key to effi cient cooling
Data centers that rely on simple hot/cold aisle methods over-cool
nearly 2.5 times to compensate for the mixing of hot and cold air.
• New server designs exhaust air in excess of 140˚F leading to
very hot aisles and challenging working conditions
• On average, 60% of available cooling is wasted due to bypass
and re-circulation airfl ow
• Air is supplied well below ASHRAE temp limits to address hot air
contamination and attempt to control temperature at rack intake
• Despite gross over-cooling, 10% of racks experience hot spots
Without heat containment, hot air mixes with cold leading to gross over-cooling.
Reference: ASHRAE Journal Article - Designing Better Data Centers, 12/07
EPA - Uptime Institute conference material
Studies show 250% over-cooling required when hot air is uncontrolled.
The Value of containment cooling
By containing and directing heat, the Geist cooling method
maximizes effi ciency while easily maintaining an ideal temperature
throughout the data center.
• Contains and evacuates 100% of the heat - no heat mixing with
the cooling simplifi es the cooling circuit
• Heat exhaust direct from the cabinets eliminates cool air bypass
• Maximizes chiller plant effi ciency with highest possible return air
temperatures
• Expertly manufactured chimneys and rack enclosures eliminate
makeshift solutions like vinyl plastic sheeting
• Maintains a perfectly controlled and consistent IT environment
Stabilize IT intake air temperature to within a few degrees of the supply air temperature
at all points in the data center. Full heat return - cool air bypass eliminated.
Geist manufactured chimneys and enclosures capture hot air and expel it beyond the
cold air surrounding the cabinet rows.
Containment Cooling
Maximize IT density and lower operating costs by relentlessly
controlling hot air; automated feedback cuts total fan energy 40%.
Active Cabinet or Row Containment MethodGeist’s cooling philosophy centers on two critical components
1) containing heat, 2) expelling heat directly to the CRAC units.
This two-step focus maintains the ideal temperature for data
center equipment. The first step is addressed by Geist’s expertly
manufactured chimneys and enclosures. The second step relies
on sophisticated temperature and pressure sensors to control
fan speeds and exhaust hot air through the chimneys at the
most efficient rate. The combination of hot air containment and
intelligently controlled fan speed creates a consistent climate
controlled environment in the data center and within the cabinet
rows.
• Hot aisle/cold aisle layout eliminated
- With hot air contained, data center room becomes a comfort
aisle for ideal working conditions
- Eliminates hot air mixing, wrap around heating and hot spots
- Bypass eliminated, 100% use of cooled air
• No row based cooling units to take up fl oor space
• Complete hot air separation enables highest CRAC/CRAH return
air temperatures
• Actively balances return air fl ow with cabinet supply requirements
• Eliminates raised fl oor pressure balancing issues
• Suitable for slab or raised-fl oor environments
• 1:1 air fl ow balance makes cooling over-provision unnecessary
• Allows for more densely populated cabinets
With hot air contained, data center room maintains a “comfort” temperature for working conditions. Hot air separation enables highest CRAC/CRAH return air temperatures.
Sophisticated temperature and pressure sensors control redundant fan
speeds to exhaust hot air through the chimneys at the most efficient rate. Plug and play fan units make for easy installation and maintenance.
+1.402.474.3400geistglobal.com
Common PlenumWith Geist’s customizable cooling components, a common air
plenum can be created across multiple cabinets. The common
plenum then allows multiple Geist cooling units to work in
concert by utilizing the IP network. This approach provides
scalability as required and lowers the total cost of deployment.
Plenum components allow Geist cooling units to be installed
every 6 inches. This fl exible system placement avoids overhead
obstructions such as cable trays.
Load Sharing• Multiple systems work together to share cabinet loads
• Operational redundancy increases as systems work in concert
• In the event of utility failure, heat continues to be exhausted by
the Geist cooling unit connected to your UPS
Automated Control• Automated load balancing eliminates micromanaging airfl ow
requirements
• Automatic notifi cation of system threshold breach via email or SNMP
• Environmental conditions monitored and reported automatically
• Geist’s Environet software aggregates total air fl ow load and automates
defi ning total air fl ow requirements, allowing lowered air fl ow across the
data center, saving 40% fan energy.
Scalable Capacity• System capacity automatically scales as loads are added or removed
• Automated load sharing returns all heat directly to return air plenum
• High density loads can be directly coupled for single cabinet isolation
• Load sharing leads to lower cost per deployed kW, allowing all fans
to run at energy effi cient speeds
4 kW
5 kW
4 kW
6 kW
8 kW
8 kW
9 kW
8 kW
EC-30 EC-30 EC-30
58% 58% 58%
52 52 kWkW
TotalTotal
RACK TRANSITION PLENUM
10 kW
9 kW
10 kW
12 kW
10 kW
10 kW
10 kW
15 kW
EC-30 EC-30 EC-30
57% 57% 57%
86 86 kWkW
TotalTotal
EC-30
57% 57%
EC-30
A common air plenum across cabinets allows multiple Geist cooling units to work in
concert utilizing the IP network to communicate as one unit. Optional placement of
Geist cooling units, avoids overhead obstructions such as cable trays.
Multiple layers of system redundancy increase as systems work in concert.
Multiple systems work together to share cabinet loads.
Passive Containment
Headline needed ----------------------------------
With the Geist passive containment option, every cabinet can
be appropriately controlled. Low density cabinets can take
advantage of the passive chimney system but can be easily
upgraded as they mature and loads begin to increase. Our
solution grows and adjusts to the data center’s needs. You can
feel confi dent that you are not limiting your cabinet’s capacity due
to reaching the limits of the passive option.
To maintain proper air fl ow and prevent air recirculation, Geist
offers a variety of cabinet blanking panels. A rack without
proper blanking panels can result in thermal damage due to
improper cooling as well as excessive energy consumption
and an increased carbon footprint. Each Geist blanking panel
is engineered with an overlapping lip for an improved seal to
prevent hot air from escaping to the front of the cabinet.
Blanking Panels Block unnecessary mixing of hot and cold air.
A
3UCMRS
2URS
1UBPSKO
1UBP2UBP
3UBP
5UBP
4UWR
DETAIL A
PANELS OVERLAPFOR IMPROVED SEAL
800.432.3219 geistglobal.com
Management Software
Maximize cooling oversight and control with software
management solutions.
RacknetThe Racknet product line provides a comprehensive set of
products for managing rack level data and white space with a
single point of integration. The intuitive interface allows for easy drag
and drop confi gurations, giving complete in-house customization
capability. This comprehensive product line auto-discovers SNMP
devices, making installation and set-up fast and simple. The
aggregated results collected across your facilities provide a holistic
view of your enterprise effi ciency.
• Racknet-Aggregator (Racknet-A) : Racknet-A connects to GNET
via 48 network ports to collect critical data from Geist products.
Data can then be accessed easily from one location.
• Racknet-Aggregator Server (Racknet-AS) : Racknet-AS
includes the full-feature set of the Racknet product line. It can
be used with third party equipment, has 48 network port console
for direct connection and includes full customization capabilities.
• Racknet-Server (Racknet-S) : Racknet-S gathers data from
Geist products and third-party equipment. It also allows
users to fully customize graphics and collections.
EnvironetEnvironet is a highly customizable, fully scalable system with
a single point of access for all your monitoring needs. Geist
provides monitoring, trending, alarming and custom views of up
to tens of thousands of monitored data points. The aggregated
results are collected across your facilities and presented through
a visually rich graphical user interface.
Whether you have a single location or multiple locations around
the globe, Environet lets you monitor all your mission critical
components from anywhere. Using Environet’s drill-down
capabilities, you can track statuses of an enterprise, drill into an
individual facility, or view a single point of information all within the
same application.
Environet integrates with numerous communication protocols
allowing the system to work effi ciently with existing equipment.
Support for a wide variety of manufacturers makes it easy to
integrate with your facility.
Eliminate network switch heat related failures by
strategically targeting the problem area.
Network Switch Cooling
Geist’s switch cooling product line allows network switches to
breathe cool air regardless of where they are mounted in the rack.
Mounting switches in the back of the cabinet does allow for more
convenient cabling connections. The trade-off is that the switch is
fed air that has already been pre-heated by the servers.
The Geist network switch cooling products are available in a wide
range of confi gurations and rack space sizes. Designed to work
with 1U to 9U devices and beyond, having the ability to channel
air to every kind of intake / exhaust confi guration imaginable such
as side in - rear out, front in - side out, rear in - front out. Geist’s network switch cooling units move cool air from the cabinet front
to the rear mounted switches to eliminate heat related switch failures.
NETWORK SWITCH
2 BUILT IN FANS
Designed to eliminate compounded heating of intake air for
Cisco 6509 and Nexus 7018 switches that are arranged in a
row layout, the GSA9 directs the hot air into the hot aisle where it
can be properly handled. With no active components, the GSA9
unit elegantly redirects the heated air away from the systems that
depend on a cool air supply to run reliably and effi ciently. This
simple design is the perfect answer to protect the high dollar
investment.
2 BUILT IN
FANS
NETWORK SWITCH
GSA2-004
GSA9-001
GSA2-002
NETWORK SWITCH
GSA1-001