Control EquipmentElbow Type Speed Controllers (with quick joint) SC7 ……VK4
Biaxial Rotation Type Speed Controllers (with quick joint) SC73 …VK8
Inline Speed Controllers SC9
Elbow Type Speed Controllers SC8
Speed Controllers SC5
Speed Controllers SC6
Speed Controllers SC
Speed Controller Mufflers SM1
Plug Silencers PSA
Silencers SA2
Silencers SA
Muffle Cleaners MFC2
Check Valves CV1
Shuttle Valves SV1
Quick Exhaust Valves QV2
Pilot Check Valves PCV
………………………………VK12
………………………VK14
…………………………………………VK16
…………………………………………VK18
……………………………………………VK20
………………………………VK22
………………………………………………VK23
……………………………………………………VK24
………………………………………………………VK25
…………………………………………VK26
………………………………………………VK28
………………………………………………VK29
……………………………………VK30
………………………………………VK32
2VK
3VK
Control Equipment
Product OutlineControl Equipment Product Outline Control EquipmentControl Equipm
ent
Modelnumber
Applicable tube O.D (mm)Page
SC710-*
SC711-*
SC712-*
SC713-*
SC714-*
Port size
M5×0.8
R1/8
R1/4
R3/8
R1/2
φ12φ10φ8φ6φ4Model
SC7Elbow Type
Speed Controllers(with quick joint)
SC-8
SC-10
SC-15
SC-20
SC-25
SCSpeed Controllers
SC730-*
SC731-*
SC732-*
SC733-*
M5×0.8
R1/8
R1/4
R3/8
SC73Biaxial Rotation TypeSpeed Controllers(with quick joint)
SC900-04
SC900-06
SC900-08
SC9Inline
Speed Controllers
SC800
SC801
SC802
SC803
SC8Elbow Type
Speed Controllers
SC501(P)
SC502
SC503
SC504
SC5Speed Controllers
SC602
SC603
SC604
SC6Speed Controllers
Modelnumber
Port sizePageR1/8M5 R1/4 R3/8 R1/2 R3/4 R1Model
VK4
VK4
VK4
VK4
VK4
VK8
VK8
VK8
VK8
VK12
VK12
VK12
VK14
VK14
VK14
VK14
VK16
VK16
VK16
VK16
VK18
VK18
VK18
VK20
VK20
VK20
VK20
VK20
SM100
SM101
SM102
SM103
SM104
SM106
SM108
SM1Speed Controller
Mufflers
VK22
VK22
VK22
VK22
VK22
VK22
VK22
Modelnumber
Port sizePageR1/8M5 R1/4 R3/8 R1/2 R3/4 R1 R1 1/2 R2Model
PSA101
PSA102
PSA103
PSAPlug Silencers
VK23
VK23
VK23
SA-5
SA-6
SA-8
SA-10
SA-15
SA-20
SA-25
SASilencers
VK25
VK25
VK25
VK25
VK25
VK25
VK25
SA2Silencers
SA2-M5
SA2-06
SA2-08
SA2-10
VK24
VK24
VK24
VK24
CV101
CV102
CV103
CV104
CV106
CV108
CV1Check Valves
VK28
VK28
VK28
VK28
VK28
VK28
SV1Shuttle Valves
SV101
SV102
VK29
VK29
QV2-8
QV2-10
QV2-15
QV2-20
QV2-25
QV2Quick Exhaust
Valves
VK30
VK30
VK30
VK30
VK30
PCV-02
PCV-03
PCV-04
PCV-06
PCV-10
PCVPilot CheckValves
VK32
VK32
VK32
VK32
VK32
Note) The connecting ports of the SA2 silencers and pilot check valves have G threads.
MFC2Muffle Cleaners VK26
4VK
5VKElbow Type Speed Controllers (with quick joint)
Port Size: M5×0.8・R1/8・R1/4・R3/8・R1/2SC7 Elbow Type Speed Controllers (with quick joint)Port Size: M5×0.8・R1/8・R1/4・R3/8・R1/2 SC7
Control Equipm
ent SC7SC7 Control Equipment
Meter-out
Meter-in
JIS symbol
Sectional Drawing
ItemModel number
Port size
Working fluid
Working pressure range
Proof test pressure
Working temperature range
Recommended tube
Effectivesectionalarea*Flow rate
Metered flow
Free flow
Metered flow
Free flow
SC710-
M5×0.8
1.5
1.4
75
70
Air0.1 to 1 MPa
1.5 MPa
0406 SC711-04
4.5
4.5
230
230
SC711-
4.6
4.5
240
230
0608 SC712-
R1/4
9.5
9.1
490
470
060810
SC713-
R3/8
23.1
16.5
1190
850
0810 SC714-12
R1/2
24.2
22.1
1250
1140
R1/8
This drawing shows the structure for meter-out control.In the case of meter-in control, the umbrella-shaped seal isinstalled in the inverse direction.
Port size
0
1
2
M5×0.8
R1/8
R1/4
Applicable tube OD
Model Number
Explanation of Symbols
When placing an order, specify the model number shown below.
SC71 1 - 04 - 1
04
06
08
4mm
6mm
8mm
3
4
R3/8
R1/2
10
12
10mm
12mm
Metering type
0
1
Meter-out
Meter-in
●With needle stopper when fully opened
●Nylon tube for N2 Series●Urethane tube for U2/TE Series
V seal(HNBR)
Release sleeve(PBT)
*Collar (brass)Lock ring (stainless steel)Back ring (polyacetal)
*Metallic body (brass)●Threaded portion subjected to sealing treatment
Umbrella-shaped seal(HNBR)
O-ring(NBR)
Plastic body(PBT)
●Good response under low pressure
*Handle (brass)
Tube
Lock nut (aluminum)
Ⓐ
Free flowMetered flow
Free flowMetered flow
Ⓑ
Ⓑ
Meteringtype
Meter-out Meter-inLock nut color: Aluminum color Lock nut color: Red (alumite treatment)
+5 to +60℃Nylon tube (N2 Series)
Urethane tube (U2/TE Series)
●Flow rate at a primary pressure of 0.5 MPa and at 20℃●The effective sectional area is calculated from the flow rate.●For the working pressure range and working temperature range, see the specifications for the tube.
●M5 type is provided with a gasket (SPCC+NBR).
Method of controlling exhaust flow rate from pneumatic actuator
Method of controlling supply air flow rate to pneumatic actuator
●The *-marked parts in the above figure are plated with electroless nickel.
*Needle (brass)
Needle O-ring(NBR)
*Check valve (brass)
Ⓐ
Ⓑ
Ⓐ
Notes)
mm2
ℓ/min(ANR)
Speed controllers ensuring tubingdirection in 360° and havingjoint for quick tube connection●The rotary body enables to connect a tube in any direction in 360°.●Two types of control, meter-out control and meter-in control.●Easy installation, no spanner needed.●Sealing treatment on the taper thread provides no sealing work. (M5 ports are sealed with gaskets.)●The needle does not come off even if it is fully opened.●All brass parts are plated with electroless nickel.
Ⓐ
Ⓑ
Ⓐ
Ⓑ
❸
❸
❶
❶
❷
❷
Specifications
Flow Characteristic CurvesSC710-04-* SC730-04-*SC710-06-* SC730-06-*
SC711-06-* SC731-06-*SC711-08-* SC731-08-*
SC711-04-*SC731-04-*
SC712-06-* SC732-06-*SC712-08-* SC732-08-*SC712-10-* SC732-10-*
SC713-08-* SC733-08-*SC713-10-* SC733-10-*
SC714-12-*
0.9 MPa
0.7 MPa
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
0
20
40
60
80
100
120
140
150
100
50
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8
0.9 MPa
0.7 MPa
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
0
50
100
150
200
250
300
400
350
50100150200250300350400450
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8 9 10 11
0.9 MPa
0.7 MPa
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
050100150200250300
400450500
350
50100150200250300350400450
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8 9 10 11
0.9 MPa
0.7 MPa
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.80.9
0100200300400500600
8009001000
700
100200300400500600700800900
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8 9 10 11
0.9 MPa
0.7 MPa
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
0
2004006008001000
140016001800
1200
200
400
600
800
1000
1200
1400
1600
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8 9 10 15111213 14
0.9 MPa
0.7 MPa
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
0
500
1000
2000
2500
1500
200400600800100012001400
2000
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8 9 10 15111213 14
16001800
■Metered flow ■Metered flow ■Metered flow
■Free flow ■Free flow ■Free flow
■Metered flow ■Metered flow ■Metered flow
■Free flow ■Free flow ■Free flow
6VK Elbow Type Speed Controllers (with quick joint)
Port Size: M5×0.8・R1/8・R1/4・R3/8・R1/2SC7SC7 Control Equipment
Unit: mm
CAD/DATAis available.SPEED CONTROLLER/TSC71
aA
M5×0.8
L2
M
N
H×φ
L1
φ2
φ8
With gasket
F
D1T
D
4
L3
K
Dimensional Table: Elbow type
Modelnumber
Symbol Port size
T
Weight
(g)
ApplicabletubeOD
aPositionof gauge
plane
FTubefittinglength
L1
SC710−04−
SC710−06−
SC711−04−
SC711−06−
SC711−08−
SC712−06−
SC712−08−
SC712−10−
SC713−08−
SC713−10−
SC714−12−
φ4
φ6
φ4
φ6
φ8
φ6
φ8
φ10
φ8
φ10
φ12
φ10
φ10
φ13
φ13
φ13
φ13
φ13
φ13
φ16
φ16
φ20
φ8
φ8
φ10
φ10
φ10
φ10
φ10
φ10
φ13
φ13
φ16
φ9.7
φ9.7
φ13.5
φ13.5
φ13.5
φ19.4
φ19.4
φ19.4
φ24
φ24
φ28
19.5
20.5
22.5
22.5
24
24.5
26
29
28
31
34.5
L2
11
11
18
18
18
23.5
23.5
23.5
25
25
27
L3K
Fullyclosed
Fullyopen
24.5
25.5
29.7
29.7
31.2
34.2
35.7
38.7
40
43
48.5
A N M D1
φ9.7
φ12.5
φ9.7
φ12.5
φ14.5
φ12.5
φ14.5
φ17.5
φ14.5
φ17.5
φ20
D
4
4
10
10
10
14
14
14
14.5
14.5
16.5
-
-
3.97
3.97
3.97
6.01
6.01
6.01
6.35
6.35
8.16
13.5
15
13.5
15
16
15
16
19
16
19
20
8×φ9
8×φ9
13×φ14
13×φ14
13×φ14
17×φ18.3
17×φ18.3
17×φ18.3
21×φ22.6
21×φ22.6
24×φ26
10
11
26
27
29
51
52
55
84
87
131
29
29
41
41
41
48.5
48.5
48.5
51.5
51.5
55
32
32
46
46
46
55
55
55
59
59
63
0101010101010101010101
R1/8
R1/4
R3/8
R1/2
●Meter-out: 0 Meter-in: 1
M5×0.8
H×φWidth across
flats×max OD
SC7
8VK
9VKBiaxial Rotation Type Speed Controllers (with quick joint)
Port Size: M5×0.8・R1/8・R1/4・R3/8SC73 Biaxial Rotation Type Speed Controllers (with quick joint)Port Size: M5×0.8・R1/8・R1/4・R3/8 SC73
Control Equipm
ent SC73
SC73 Control Equipment
Speed controllers ensuring three-dimensional piping and having jointfor quick tube connection●The tube direction can be adjusted freely in the three-dimensional directions.●Two types of control, meter-out control and meter-in control.●Easy installation, no spanner needed.●Sealing treatment on the taper thread provides no sealing work.●The needle does not come off even if it is fully opened.●All brass parts are plated with electroless nickel.
Ⓐ
Ⓑ
Ⓐ
Ⓑ
❸❶ ❷
Ⓑ
Ⓑ
Ⓐ
Ⓐ
Ⓑ
Ⓐ
Metering typeMeter-out Meter-inMe
tered flow
Free flow
Metered flow
Free flow
V seal (HNBR)
*Blank (brass)
Speed controller case (PBT)
Case O-ring (NBR)
*Check valve (brass)
Release sleeve(PBT)
*Collar (brass)Lock ring (stainless steel)Back ring (polyacetal)
*Metallic body (brass)Threaded portion subjected tosealing treatment
O-ring(NBR)
Plastic body(PBT)
Umbrella-shaped seal(HNBR)●Good response under low pressure
Tube
Lock nut(aluminum)
0
1
M5×0.8
R1/8
SC73 1 - 06 - 0
04
06
4mm
6mm
2
3
R1/4
R3/8
08
10
8mm
10mm
0
1
Specifications
ItemModel number
1.5
1.4
75
70
Air
0.1 to 1 MPa
1.5 MPa
SC731-04SC730- SC731-
4.5
4.5
230
230
0608
0406 SC732-
4.6
4.5
240
230
060810
SC733-
R1/4
9.5
9.1
490
470
0810
R3/8
23.1
16.5
1190
850
R1/8M5×0.8
+5 to +60℃
●Nylon tube for N2 Series●Urethane tube for U2/TE Series
*Needle (brass)
Needle O-ring(NBR)
●M5 type is provided with a gasket (SPCC+NBR).
●The *-marked parts in the above figure are plated with electroless nickel.
Meter-out
Meter-in
JIS symbol
Port size
Working fluid
Working pressure range
Proof test pressure
Working temperature range
Recommended tube
Metered flow
Free flow
Metered flow
Free flow
Nylon tube (N2 Series)Urethane tube (U2/TE Series)
●Values at a primary pressure of 0.5 MPa and at 20℃.●The effective sectional area is calculated from the flow rate.●For the working pressure range and working temperature range, see the specifications for the tube.
Notes)
Model NumberWhen placing an order, specify the model number shown below.
❸
❶
❷
Port size
Applicable tube OD
Metering type
Meter-out
Meter-in
Explanation of Symbols
Sectional Drawing This drawing shows the structure for meter-out control.In the case of meter-in control, the umbrella-shaped seal isinstalled in the inverse direction.
●With needle stopper when fullyopened
Handle (brass)
Lock nut color: Aluminum color
Lock nut color: Red (alumite treatment)
Method of controlling exhaust flow rate from pneumatic actuator
Method of controlling supply air flow rate to pneumatic actuator
Effectivesectionalarea mm2
*Flow rateℓ/min(ANR)
Flow Characteristic CurvesSC710-04-* SC730-04-*SC710-06-* SC730-06-*
SC711-06-* SC731-06-*SC711-08-* SC731-08-*
SC711-04-*SC731-04-*
SC712-06-* SC732-06-*SC712-08-* SC732-08-*SC712-10-* SC732-10-*
SC713-08-* SC733-08-*SC713-10-* SC733-10-*
0.9 MPa
0.7 MPa
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
0
20
40
60
80
100
120
140
150
100
50
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8
0.9 MPa
0.7 MPa
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
0
50
100
150
200
250
300
400
350
50100150200250300350400450
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8 9 10 11
0.9 MPa
0.7 MPa
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
050100150200250300
400450500
350
50100150200250300350400450
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8 9 10 11
0.9 MPa
0.7 MPa
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.80.9
0100200300400500600
8009001000
700
100200300400500600700800900
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8 9 10 11
0.9 MPa
0.7 MPa
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
0
2004006008001000
140016001800
1200
200
400
600
800
1000
1200
1400
1600
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8 9 10 15111213 14
■Metered flow ■Metered flow ■Metered flow
■Free flow ■Free flow ■Free flow
■Metered flow ■Metered flow
■Free flow ■Free flow
10VK Biaxial Rotation Type Speed Controllers (with quick joint)
Port Size: M5×0.8・R1/8・R1/4・R3/8SC73SC73 Control Equipment
Unit: mm
CAD/DATAis available.SPEED CONTROLLER/TSC73
M
D1
N D
L1
aA
L2
F
D2L4
M5×0.8
H×φ
φ2
φ8
With gasket
T
4
L3
K
Dimensional Table: Biaxial rotation type
SC730-04-
SC730-06-
SC731-04-
SC731-06-
SC731-08-
SC732-06-
SC732-08-
SC732-10-
SC733-08-
SC733-10-
φ4
φ6
φ4
φ6
φ8
φ6
φ8
φ10
φ8
φ10
φ10
φ10
φ13
φ13
φ13
φ13
φ13
φ13
φ16
φ16
φ5
φ5
φ10
φ10
φ10
φ10
φ10
φ10
φ13
φ13
φ9.7
φ12.5
φ9.7
φ12.5
φ14.5
φ12.5
φ14.5
φ17.5
φ14.5
φ17.5
12
12
14
14
16
17
18.5
19.5
22
22
11
11
18
18
18
23.5
23.5
23.5
25
25
30.5
31.5
37.5
38.0
42.0
43.5
47.5
52.5
51.0
54.0
24.5
24.5
29
29
33
34
38
40.5
45
45
φ9.7
φ9.7
φ14.4
φ14.4
φ14.4
φ19.4
φ19.4
φ19.4
φ24
φ24
φ9.7
φ9.7
φ9.7
φ9.7
φ14.4
φ9.7
φ14.4
φ19.4
φ19.4
φ19.4
4
4
10
10
10
14
14
14
14.5
14.5
-
-
3.97
3.97
3.97
6.01
6.01
6.01
6.35
6.35
13.5
15
13.5
15
16
15
16
19
16
19
12
12
29
31
34
55
59
65
93
97
29
29
41
41
41
48.5
48.5
48.5
51.5
51.5
32
32
46
46
46
55
55
55
59
59
01010101010101010101
R1/8
R1/4
R3/8
●Meter-out: 0 Meter-in: 1
M5×0.8
Modelnumber
SymbolPort size
T
Weight
(g)
ApplicabletubeOD
L1 L2 L3 L4K
Fullyclosed
Fullyopen
A N M D1 D2D
8×φ9
8×φ9
13×φ14
13×φ14
13×φ14
17×φ18.3
17×φ18.3
17×φ18.3
21×φ22.6
21×φ22.6
H×φWidth acrossflats×
max OD
aPositionof gaugeplane
FTubefittinglength
SC73
12VK
13VK
SC9 Control Equipment C
ontrol Equipment SC9
Inline Speed Controllers Inline Speed ControllersSC9 SC9Unit: mm
CAD/DATAis available.SPEED CONTROLLER/TSC9
Built-in quick jointin port●Suitable for speed control of actuators.●The controllers can be attached directly to tubes without joints.●Several speed controllers can be combined in the shape of a manifold with the aid of fittings.●The controllers can be installed vertically with the brackets.●All brass parts are plated with electroless nickel. Ⓐ Ⓑ
❹❸
12❼❽
❾10
1314
❶
❷❺
11
❻
❶❷❸❹❺❻❼❽❾1011121314
ⒶⒷ
Sectional Drawing
ConnectingpinBracket
Specifications
1.5
1.4
75
70
SC900−04 SC900−06 SC900−08
4.5
4.5
230
230
9.5
9.1
490
470
11 32 48
Applicable tube OD
●Body type
■Controller only
SC900 - 06 - B
04
06
08
4mm
6mm
8mm
Accessories
Blank
B
Without bracket
With bracket
❷Accessories❶Applicable tube OD
■Manifold
SC900 - 04❶Applicable tube ODSeries
●Bracket symbol SZZ
Note) The brackets come two to a set.
BRK 04Bracket size04: For SC900-0406: For SC900-0608: For SC900-08
●Symbol of connecting pin SZZ
Note) The pins come ten to a set.SC900-06 and SC900-08cannot be connected.
HPN 04Connecting pin size04: For SC900-0406: For SC900-06 or 08
Name MaterialNo.
Parts List
*Handle
*Needle
Lock nut
*Metallic body
Plastic body
Umbrella-shaped seal
Back ring
Lock ring
*Collar
Release sleeve
V seal
Needle O-ring
*Check valve
O-ring
Brass
Brass
Aluminum
Brass
PBT
HNBR
Polyacetal
Stainless steel
Brass
PBT
HNBR
NBR
Brass
NBR
Example of manifold connection
(With 4 connecting pins)
The *-marked parts are plated with electroless nickel.
Explanation of Symbols
JIS symbol
Item
Model number
Air0.1 to 1 MPa
1.5 MPa
+5 to +60℃
Working fluid
Working pressure range
Proof test pressure
Working temperature range
Weight
Metered flow
Free flow
Metered flow
Free flow
g
●Values at a primary pressure of 0.5 MPa and at 20℃.●The effective sectional area is calculated from the flow rate.●For the working pressure range and working temperature range, see the specifications for the tube.
Notes)
Model NumberWhen placing an order, specify the model number shown below.
❶
❷
Effectivesectionalarea
*Flow rate
mm2
ℓ/min(ANR)
H
G
J
K
S
2×2ーSS
2ーTT
T
UF
L
D
M
N
O
E
P
Flow Characteristic CurvesSC900-04 SC900-06 SC900-08■Metered flow ■Metered flow ■Metered flow
■Free flow ■Free flow ■Free flow
Dimensional TableApplicable
tubeOD
FTubefittinglength
D
SC900-04
SC900-06
SC900-08
φ4
φ6
φ8
9.7
12.5
14.5
10.5
15
17.5
13.5
15
16
E G
6.5
9
10.5
6
8
9
H
18
25.5
29.5
26
38
41.5
28.5
43
47
JK
L
40
47
55
M
5
10
10
N
8
13
13
O
14
20
22
P
20
28
30
S
23.5
28
30.5
SS
φ5
φ5
φ5
φ3.2
φ4.2
φ4.2
T
33.5
38
40.5
TT U
10
14
14
0.9 MPa
0.7 MPa
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
0
20
40
60
80
100
120
140
150
100
50
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8
0.9 MPa
0.7 MPa
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
0
50
100
150
200
250
300
400
350
50
100
150
200
250
300
350
400
450
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8 9 10 11
0.9 MPa
0.7 MPa
0.5 MPa
0.3 MPa
0.1 MPa
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
0100200300400500600
8009001000
700
100
200
300
400
500
600
700
800
900
0
1 2 3 4Number of needle rotation
Pressure MPa
5 6 7 8 9 1011
Modelnumber
Symbol
Fullyclosed
Fullyopen
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
SC9
14VK
15VK
SC8 Control Equipment C
ontrol Equipment SC8
Unit: mmSpeed ControllerPort Size: M5×0.8・R1/8・R1/4・R3/8
Speed ControllerPort Size: M5×0.8・R1/8・R1/4・R3/8SC8 SC8
CAD/DATAis available.SPEED CONTROLLER/TSC8
Meter-out
Meter-in
JIS symbol
Compact type controllerswhich can be installeddirectly on cylinders●The rotary body enables to connect a tube in any direction in 360°.●Two types of control, meter-out control and meter-in control.●Compact.●The round knob ensures easy fine adjustments of flow rate.●The needle does not come off even if it is fully opened.
Ⓐ
Ⓑ
Ⓐ
Ⓑ
Ⓐ
Ⓑ
Sectional Drawings
Gasket
Adjusting cover (brass)(with needle stopper whenfully opened)
Body (brass)(nickel-plated)
Body (brass)(nickel-plated)
O-ring(NBR)O-ring(NBR)
Check seal(NBR)
Needle guide (brass)(nickel-plated)
Needle (stainless steel)
Adjustment handle (brass)
Lock nut (brass)●Meter-out type (plated)●Meter-in type (brass color)
(nickel-plated)
O-ring(NBR)O-ring(NBR)O-ring(NBR)
Check seal(NBR)
Needle guide (brass)(nickel-plated)
Needle (stainless steel)(with needle stopper whenfully opened)
Adjustment handle (brass)
Lock nut (aluminum)●Meter-out type (aluminum color)●Meter-in type (red, alumite treatment)
Port size
0
1
M5×0.8
R1/8
Model Number When placing an order, specifythe model number shown below.
SC80 1 - 0
2
3
R1/4
R3/8
Metering type
0
1
Meter-out
Meter-in
Specifications
M5×0.8
1.3
1.4
85
95
Air
+5 to +60℃
SC800 SC801
R1/8
3.8
4.5
250
300
SC803
R3/8
14.8
14.2
960
920
SC802
R1/4
8.3
8.8
540
580
20 40 16590
*Flow rate at primary pressure of 0.5 MPa
0.05 to 1 MPa
1.5 MPa1.05 MPa
0.05 to 0.7 MPa
Free flowMetered flow
Free flowMetered flow
Metering typeMeter-out Meter-in
Lock nut color: Nickel-plated(SC800-0)Aluminum color(SC801-0・SC802-0・SC803-0)
Lock nut color: Brass color(SC800-1)Red(SC801-1・SC802-1・SC803-1)
●SC800 ●SC801 to 803
The above figures show the internal structure of the meter-out type controllers.
Explanation of Symbols
Item
Model number
Port size
Working fluid
Working pressure range
Proof test pressure
Working temperature range
Weight
Metered flow
Free flow
Metered flow
Free flow
Ⓐ
Ⓑ
Ⓐ
Ⓑ
Ⓐ
Ⓑ
Method of controlling exhaust flow rate from pneumatic actuator
Method of controlling supply air flow rate to pneumatic actuator
g
Effectivesectionalarea
*Flow rate
mm2
ℓ/min(ANR)
●Flow rate at a primary pressure of 0.5 MPa and at 20℃
Note)
❶ ❷
❶
❷
Dimensional Table
Modelnumber
SymbolA
SC801
SC802
SC803
16
21
24
18
23.5
26.5
DC
8
11.5
12
R1/8
R1/4
R3/8
Rc1/8
Rc1/4
Rc3/8
Port size E
Port size G
23
30.5
36
F
41
48.5
55
46
55
63.5
BFully
closedFullyopen
H
14
19
24
Flow Characteristic Curves (metered flow) Flow CharacteristicCurves (free flow)SC800 SC801
SC802 SC803
0Number of needle rotation
Number of needle rotation
1
20
40
60
80
100
120
2 3 4 5 6 7 8 9
0.7 MPa
0.5 MPa
0.3 MPa
0Number of needle rotation
Number of needle rotation
1
50
100
150
200
250
300
350
2 3 4 5 6 7 8 9 10
0.7 MPa
0.5 MPa
0.3 MPa
0 1
100
200300
400500
700
600
2 3 4 5 6 7 8 9 10 11 12 13 14
0.7 MPa
0.5 MPa
0.3 MPa
0 1100200300400500
700800900100011001200
600
2 3 4 5 6 7 8 9 10 111213141516
0.7 MPa
0.5 MPa
0.3 MPa
0Pressure MPa
0.1
1200
1100
1000
900
800
700
600
500
400
300
200
100
0.2 0.3 0.4 0.5 0.6 0.7
SC803
SC802
SC801
SC800
φ8 10φ9.6
15
4
14
M5×0.8
M5×0.8depth 4
34(39)
9.5
F H
G
E
D
C
B
A
SC8
●SC800
●The parenthesized values are the dimensions in the fully open state.●SC800 has a gasket.
●SC801 to 803
Ⓐ
Ⓑ
Ⓐ
Ⓑ
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
16VK
17VK
SC5 Control Equipment C
ontrol Equipment SC5
Speed ControllerPort Size: Rc1/8・Rc1/4・Rc3/8・Rc1/2
Speed ControllerPort Size: Rc1/8・Rc1/4・Rc3/8・Rc1/2SC5 SC5Unit: mm
JIS symbol
Suitable for actuatorspeed control●Light and compact.●Easy fine adjustments of flow rate.●The round knob ensures easy adjustments of flow rate.●Stackable. (SC501)●Panel-mountable. (SC501-P)
Ⓐ Ⓑ
Sectional Drawings
Specifications
Item
Port size
Working fluid
Working pressure range
Proof test pressure
Working temperature range
Weight
Metered flow
Free flow
Metered flow
Free flow
Air
1.5 MPa
0 to +60℃ (No freezing)
SC501(Stacking type)
SC501P(Panel-mounting type)
Rc1/8
2.4
4.3
180
320
0.02 to 1 MPa
SC502
Rc1/4
12
19
800
1200
SC503
Rc3/8
28
45
1800
3000
SC504
Rc1/2
28
60
1800
4000
50 60 170 410 390
0.1 to 1 MPa
Model Number When placing an order, specify the model number shown below.
SC5 01 PSeries
Port size01: Rc1/8
Installing methodNo symbol: Stacking typeP: Panel-mounting type
SC5 03
Series
Port size02: Rc1/403: Rc3/804: Rc1/2
Body
Spring
Needle
End plug
Poppet
Handle(plastic)Lock nut
Body(zinc alloy die-cast)
Poppet(NBR)
O-ring(NBR)
O-ring(NBR)
Needle guide (brass)
Panel nut (brass)
Spring (stainless steel)
Needle (brass)
Adjustment handle (brass)
Lock nut (brass)
●SC501 ●SC502・503・504
Note) Flow rate at primary pressure of 0.5 MPa
Model number
mm2
Effective sectionalarea
Note) Flow rateℓ/min(ANR)
BB
AA
g
102319
20
2ーφ4.3(Mounting holes)
28
152ーRc1/8
47
CD
E
MAXB
F
A
t
10
3
23
102
19
20
2ーφ4.3(Mounting holes)
28
15
φ10.5
2ーRc1/8
48(53)
The parenthesized values are the dimensions in the fully open state.
Plate thickness:When double nut is used:
t=3.2 maxWhen single nut is used:
t=6 max
Dimension of panel mounting hole
Metered Flow Characteristic CurvesFree FlowCharacteristic Curves
SC501・SC501P SC503 SC501・SC501P
SC502 SC504
0Number of needle rotation1 2 3 4 5 6
50
100
150
200
7 8 9 10 (Fully open)
0.5 MPa
0.4 MPa
0.3 MPa
0.1 MPa
0.2 MPa
0Number of needle rotation
1 2 3 4 5 6
20040060080010001200140016001800
7 8 9 10 11 (Fully open)
0.5 MPa
0.4 MPa
0.3 MPa
0.1 MPa
0.2 MPa
0Pressure MPa
0.1
50
100
150
200
250
0.2 0.3 0.4 0.5 0.6 0.7
0Number of needle rotation1 2 3 4 5 6
100200300400500600700
7 8 (Fully open)
0.5 MPa
0.4 MPa
0.3 MPa
0.1 MPa
0.2 MPa
0Number of needle rotation1 2 3 4 5 6
20040060080010001200140016001800
7 8 9 10 (Fully open)
0.5 MPa
0.4 MPa
0.3 MPa
0.1 MPa
0.2 MPa
SC502・503・504
0 1Pressure MPa
1000
2000
3000
4000
0.2 0.4 0.6 0.8
SC504
SC503
SC502
Dimensional TableSymbol SC502
A
B
C
D
E
F
Rc1/4
80
45
24
23
22
SC504
Rc1/2
91
63
32
26
22
Rc3/8
91
63
32
26
22
SC503
SC5
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
●SC501P (Panel-mounting type)
●SC501(Stacking type) ●SC502・503・504
ⒶⒷ
ⒶⒷ
ⒶⒷ
Modelnumber
18VK
19VK
SC6 Control Equipment C
ontrol Equipment SC6
Speed ControllerPort Size: Rc1/4・Rc3/8・Rc1/2
Speed ControllerPort Size: Rc1/4・Rc3/8・Rc1/2SC6 SC6Unit: mm
JIS symbol
Suitable for actuatorspeed control●Light and compact.●The controllers can be mounted on panels and stacked as well as connected directly to pneumatic actuators.●Stable fine adjustments can be made in a low flow rate range.
Sectional Drawing
Body
Spring Needle
Poppet
Handle
Lock nut
Specifications
Item
Model number
Air
0.05 to 1 MPa
1.5 MPa
0 to +60℃ (No freezing)
SC602
Rc1/4
7.1
31
470
2000
SC603
Rc3/8
7.1
49
470
3200
SC604
Rc1/2
7.5
53
500
3500
190 180 230
SC6 03
Series
Port size02: Rc1/403: Rc3/804: Rc1/2
●Flow rate at a primary pressure of 0.5 MPa and at 20℃
Ⓐ Ⓑ
Port size
Working fluid
Working pressure range
Proof test pressure
Working temperature range
Weight
Metered flow
Free flow
Metered flow
Free flow
Note)
Model NumberWhen placing an order, specify the model number shown below.
ⒶⒷ
Effectivesectionalarea
Note) Flow rate
mm2
g
ℓ/min(ANR)
3
4
Max. mountablepanel thicknessWith washer: 5Without washer: 8
2ーφ4.5(Mounting holes)
M18×1.5
F
C
5
E
13
MAXB
G
D
A
φ16
Dimensional TableSC602
A
B
C
D
E
F
G
Rc1/4
82
62
27
41.5
33
17
SC604
Rc1/2
84
74
32
43.5
38
19
Rc3/8
82
62
27
41.5
33
17
SC603
Metered Flow Characteristic Curves Free Flow Characteristic CurvesSC602・SC603 SC602・SC603・SC604
SC604
0Number of needle rotation
1 2 3 4 5 6
100
200
300
400
500
600
7 8 9 10
0.5 MPa
0.4 MPa0.3 MPa
0.1 MPa
0.2 MPa
0Number of needle rotation
1 2 3 4 5 6
100
200
300
400
500
600
7 8 9 10
0.5 MPa
0.4 MPa0.3 MPa
0.1 MPa
0.2 MPa
0Pressure MPa
0.2 0.4 0.6 0.8 1.0
1000
2000
3000
4000
5000
6000SC604
SC603
SC602
SC6
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
SymbolModelnumber
20VK
21VK
SC Control Equipment C
ontrol Equipment SC
Speed ControllerPort Size: Rc1/4・Rc3/8・Rc1/2・Rc3/4・Rc1
Speed ControllerPort Size: Rc1/4・Rc3/8・Rc1/2・Rc3/4・Rc1SC SCUnit: mm
JIS symbol
Sectional Drawing
SC-15
Series
Port size8: Rc1/4 20: Rc3/410: Rc3/8 25: Rc115: Rc1/2
Specifications
Item
Port size
Metered flow
Free flow
Model number
Air
0.05 to 1 MPa
1 MPa
1.5 MPa
+5 to +60℃
SC−8
Rc1/4
37.7
37.7
4200
SC−15
Rc1/2
115.2
137.4
8000
SC−20
Rc3/4
146.2
159.5
16000
SC−25
Rc1
186.1
186.1
20000
SC−10
Rc3/8
47.0
45.2
5700
200 200 400 700400
Name MaterialNo.
Parts List
BodyNeedleValveValve springBushHandleLock nutCover
Aluminum alloy die-castStainless steelCopper alloy/nitrile rubberStainless steelCopper alloyAluminum alloySteel materialAluminum alloy die-cast
Free flow
Metered flow
●Flow rate at a primary pressure of 0.5 MPa and at 20℃●Note that the controllers can cause vibration noise depending on the operating conditions (when they are used at 0.05 MPa or less, the pipes on the upstream and downstream sides are excessively throttled, or the differential pressure is low).
Note) Flow rate
Working fluid
Working pressure range
Max. working pressure
Proof test pressure
Working temperature range
Weight g
Model NumberWhen placing an order, specify the model number shown below. ❻
❼
❷
❶
❸❹
❽
Notes)
❺
❶❷❸❹❺❻❼❽
Effectivesectionalarea mm2
ℓ/min(ANR)
Suitable for actuatorspeed control●The controller mounted between cylinder and selector valve ensures easy cylinder speed adjustment.●As the flow line is widely opened, the check valve is forcibly opened. The flow rate can be adjusted in a wide range by operating the valve from the fully closed state to the fully open state.
Ⓐ Ⓑ
Ⓐ Ⓑ
B
C
A D
Dimensional TableSC−8 SC−10 SC−15 SC−20 SC−25
Port size
A
B
C
D
Rc1/4
71
27
83
32
Rc1/2
90
40
110
44
Rc3/8
71
27
83
32
Rc3/4
90
40
110
44
Rc1
112
47
132
50
Flow Characteristic CurvesSC-8 SC-15 SC-25
0 2 4 6 8 10
1000
2000
3000
4000
Number of needle rotation
0.3 MPa
0.5 MPa0.7 MPa
SC-10 SC-20
0 3 6 9 12
2500
5000
7500
Number of needle rotation
0.3 MPa
0.5 MPa0.7 MPa
0 3 6 9 12
5000
10000
15000
20000
Number of needle rotation
0.3 MPa
0.7 MPa 0.5 MPa
0 2 4 6 8 10
1500
3000
4500
6000
Number of needle rotation
0 3 6 9 12
5000
10000
15000
Number of needle rotation
0.3 MPa
0.7 MPa 0.5 MPa
SC-8 to 25
0.5 MPa0.7 MPa
0.3 MPa
Ⓐ Ⓑ
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
Flow rate ℓ/min(ANR)
SymbolModelnumber
22VK
23VK
SM1 Control Equipment C
ontrol Equipment PSA
Speed Controller Muffl erPort Size: M5×0.8・R1/8・R1/4・R3/8・R1/2・R3/4・R1
Plug SilencerPort Size: R1/8・R1/4・R3/8SM1 PSA
JIS symbol
Sectional Drawings
Dimensional Drawings
C
BB
B
HSA
L N
Port size Valve
Needle valve
Closed
Open
BodyMuffler
Specifications
Air
0 to +80℃ (No freezing)
SM100
M5×0.8
4
SM101
R1/8
11
SM102
R1/4
16
SM103
R3/8
20
SM104
R1/2
45
SM106
R3/4
60
SM108
R1
60
5 20 30 40 70 120 220
0 to 1 MPa
1.5 MPa
0 to 0.7 MPa
1.05 MPa
Dimensional Table
Modelnumber
SymbolA
SM100
SM101
SM102
SM103
SM104
SM106
SM108
4
8.5
12
12
16
18
19
Portsize
M5×0.8
R1/8
R1/4
R3/8
R1/2
R3/4
R1
8
12
14
17
22
27
36
5.5
8
10
10
10
10
13
B BB C(approx.)
9
13.8
16.2
19.6
25.4
31.0
41.0
2
3.2
3.6
3.6
3.6
3.6
5
H
18
25
30
30
37
43
46
6
13
16.5
16.5
18.5
22
22
3.5
6
6
6
6
8
7.5
LN
max minS
14
16.5
18
18
21
25
27
SM1 01
Series
Port size00:M5×0.8 01:Rc1/8 02:Rc1/403:Rc3/8 04:Rc1/2 06:Rc3/408:Rc1
Name Material
Sintered alloy
No.
❶
❷
❸
Qty.
1
1
1
Parts List
Body
Muffler
SM100:BrassSM101 to SM108: Rolled steel for general structureSM100:BrassSM101 to SM108: Carbon steel for machine structural use
Unit: mm
Needlealve
Silencer and throttle valveare integrated.Use for actuator speedcontrol and absorption ofexhaust sound.●The exhaust flow rate can be controlled in the range from 0 to 100%.●Cost effective, combination of silencer and throttle valve.
❸ ❶
❷
Item
Port size
Effective sectional area mm2 (In fully open state)
Working fluid
Working pressure range
Proof test pressure
Working temperature range
Weight
Model number
Model NumberWhen placing an order, specify the model number shown below.
g
JIS symbol
Suitable for reducingexhaust sound ofpneumatic equipment●More compact than existing silencers.●Excellent effect in absorbing sound.●Sound reduction of 15 dB or more.●Plug size not requiring a large installation space.●Small, light and low-cost.
Sectional Drawings
B A
C
Specifications
Resin
Resin
2.5
160
20
PSA101
General steel material
Sintered alloy
5
300
20
1 MPa
PSA102
General steel material
Sintered alloy
9
550
15
PSA103
-20 to +60 -20 to +80
Note 1) Flow rate at pressure of0.5 MPa
Note 2) Sound deadening effectat max. flow rate
Note 3) No freezing
Dimensional TableModelnumber
Symbol AC
PSA101
PSA102
PSA103
7
9
10
R1/8
R1/4
R3/8
5
6
8
B
Name MaterialNo. Qty.
1
1
Parts List
Body
Element
Resin
Resin
1
1
1
Body
Element
Set ring
Parts List
Dimensional Drawings
PSA 1 01
Series
Port size
01
02
03
R1/8
R1/4
R3/8
(Note) Sales unit: 5 pcs.
PSA101
PSA102103
Unit: mm
Item
Mat
eria
l
Body
Element
Effective sectional area
Note 1) Max. flow rate ℓ/min(ANR)Note 2) Sound deadening effect
Max. working pressure
Note 3) Working temperature range
Model number
℃
dB
mm2
Name MaterialNo. Qty.
❶ ❷
❶
❷
❸
❶
❷
❸
❶ ❷
Model NumberWhen placing an order, specify the model number shown below.
Stainlesssteel
General steelmaterialSinteredalloy
24VK
25VK
SA2 Control Equipment C
ontrol Equipment SA
SilencerPort Size: M5×0.8・G1/8・G1/4・G3/8
SilencerPort Size: M5×0.8・R1/8・R1/4・R3/8・R1/2・R3/4・R1SA2 SA
JIS symbol
Suitable for reducingexhaust sound ofpneumatic equipment●Excellent effect in absorbing sound.●Since the main body is made of a plastic, it is light and low-cost.●G threaded slim type.
Dimensional Drawings
Specifications
1 MPa
SA2−10SA2−08SA2−06SA2−M5
G3/8G1/4G1/8M5×0.8
20 dB (A) or more
5530156
6321
Dimensional TableModelnumber
Symbol A
SA2−M5
SA2−06
SA2−08
SA2−10
23
34
42.5
67.5
Port size
M5×0.8
G1/8
G1/4
G3/8
φ6.5
φ12.5
φ15.5
φ18.5
19
28
35.5
56
B C E
4
6
7
11.5
Unit: mm
Port size
B
A
E C
mm2
g
Model NumberWhen placing an order, specify the model number shown below.
SA2-06
Series
Port size
M5
06
08
10
M5×0.8
G1/8
G1/4
G3/8
Model number
Item
Port size
Sound deadening effect
Max. working pressure
Effective sectional area
Weight
JIS symbol
Suitable for reducingexhaust sound ofpneumatic equipment●Excellent effect in absorbing sound.●Since the main body is made of a plastic, it is light and low-cost.
Dimensional Drawings
8
7 1224
18
E C GA
B F
Port size
Port size
F CDEA
B
Specifications
0.7 MPa
20 dB (A) or more
1 MPa
SA−5 SA−6 SA−8 SA−10 SA−15 SA−20 SA−25
M5×0.8 R1/8 R1/4 R3/8 R1/2 R3/4 R1
6 15 35 55 90 235
2.5 4 10 12 27
165
57 93
Dimensional TableA
SA−6
SA−8
SA−10
SA−15
SA−20
SA−25
43
52
63
74
100
120
Port size
R1/8
R1/4
R3/8
R1/2
R3/4
R1
φ16
φ21.5
φ25
φ31
φ40
φ48
32
39
48
56
70
86
B C D
−
−
−
−
14
15
8
10
11
14
16
19
E
11
14
14
19
32
36
F
3
3
4
4
−
−
G
●SA-5
●SA-6 to 15
●SA-20・25
Unit: mm
mm2
g
Model NumberWhen placing an order, specify the model number shown below.
Modelnumber
Symbol
SA-20
Series
Port size
5
6
8
10
15
20
25
M5
R1/8
R1/4
R3/8
R1/2
R3/4
R1
Model number
Item
Port size
Sound deadening effect
Max. working pressure
Effective sectional area
Weight
26VK
27VK
MFC2 Control Equipment C
ontrol Equipment MFC2
Muffl e CleanerPort Size: Rc3/8・Rc3/4・Rc1・Rc11/2・Rc2
Muffl e CleanerPort Size: Rc3/8・Rc3/4・Rc1・Rc11/2・Rc2MFC2 MFC2Unit: mm
JIS symbol
The muffle cleanerabsorbs exhaust noiseand completelyseparates oil mist torealize more comfortableworking environment.
Air consumption ℓ/min(ANR)
Cylinder speed mm/s
450
1000
1600
3000
5618
6400
9000
10500
0 300 600 900
MFC2-10
MFC2-20
MFC2-25
MFC2-40
MFC2-50
φ300
φ250
φ200
φ180
φ160
φ140
φ125
φ100
φ80
φ63
φ40
Model Number When placing an order, specify the model number shown below.
MFC2-10-B
❶Port size ❷Accessory
Port size
Accessory
10
20
25
Blank
40
50
Rc11/2
Rc2
Rc3/8
Rc3/4
Rc1
Without bracket B With bracket
Model Selection Chart
3/8
35
450
32
0.28
3/4
105
1,600
28
0.56
1
160
3,000
32
+5 to +60℃
0.75
99.9%
11/2
350
6,400
23
1.3
2
585
10,500
22
1.8
Specifications
Series
Example: Port size Rc3/8, with bracketMFC2-10-B
MFC2−10 MFC2−20 MFC2−25 MFC2−40 MFC2−50
Select a muffle cleaner based on the air consumption on the circuit to be used.①Calculate the amount of air consumed by the actuators which operate simultaneously. When the piping capacity between the selector valve and actuators is large, add the capacity.②Multiply the calculated air consumption by 1.4, and select a model having a max. throughput flow rate higher than the obtained value.The chart shows the values obtained by multiplying the air consumption of pneumatic cylinders by 1.4. Use the chart for selecting a model.
Model selecting procedures
Example of calculationConditions
Cylinder air consumption
Working pressure: 0.5 MPa (gauge pressure)Cylinder bore: φ180Driving speed: 450 mm/s
Based on the calculated value, select MFC2-40 (max. throughput of 6400 Nℓ/min).
π4 ×18
2×45×60×0.601× × =57241.40.101
11000 Nℓ/min
Cylinderpistonarea (cm²)
speed(m/s)
Absolutepressure (MPa)
Explanation of Symbols
Item
Port size
Weight
Oil mist recovery efficiency
Modelnumber
Rc
mm2
ℓ/min(ANR)
dB
kg
●The sound deadening effect refers to the difference between the sound generated from the orifice when exhaust is fed at the max. throughput flow rate at a pressure of 0.5 MPa and the sound generated when the muffle cleaner is installed under the same conditions (1 m from the sound source).
❶
❷
Max. throughputflow rateSound deadeningeffectWorking temperaturerange
Effectivesectional area
B
A
E3ーRS
G1/4
W
X
UL
B13ーφR
φE
V
2ーφZ
Y
B
φT
Flow Characteristic Curves Application Example
Accessory SZZB: Bracket(with 3 mounting screws)
●When MFC2-20 is used at 1600 ℓ/min (ANR),the back pressure is 0.05 MPa.
The muffle cleaner has two functions: it removes oil content from actuators, valves and compressed air and absorbs exhaust sound.When exhaust is concentrated as shown above, the working environment can be made cleaner.
0.02
0.040.050.06
0.08
0.10
0 200 500 1000 2000 500010000
Bac
k pr
essu
re MPa
Flow rate ℓ/min(ANR)
MFC2-10
MFC2-20
MFC2-25
MFC2-40
MFC2-50
Cylinder A
Cylinder B
Dimensional TableA
77
102
117
137
152
B
119
169
198
258
315
R
M4×0.7 depth 8
M5×0.8 depth 10
M5×0.8 depth 10
M6×1 depth 10
M6×1 depth 10
S
Rc3/8
Rc3/4
Rc1
Rc11/2
Rc2
E
φ30
φ44
φ48
φ66
φ76
MFC2−10
MFC2−20
MFC2−25
MFC2−40
MFC2−50
Dimensional Table of BracketsApplicablemodel
B
50
70
70
100
100
B1
32
46
50
70
80
L
64
82
92
115
127
R
4.5
5.5
5.5
7
7
T
18
29
37
50
62
U
44
54
62
74
80
V
20
20
20
25
25
W
30
30
30
35
35
X
2.3
3.2
3.2
4
4
Y
30
40
40
70
70
Z
7
7
7
9
9
E
30
44
48
66
76
MFC2−10
MFC2−20
MFC2−25
MFC2−40
MFC2−50
MFC2Mounting bracket
Modelnumber
Symbol Symbol
28VK
29VK
CV1 Control Equipment C
ontrol Equipment SV1
Check ValvePort Size: Rc1/8・Rc1/4・Rc3/8・Rc1/2・Rc3/4・Rc1
Shuttle ValvePort Size: Rc1/8・Rc1/4CV1 SV1
JIS symbol
ⒶⒷ
ⒶⒷ ⒶⒷ
The valves feedcompressed air onlyin one direction anddo not feed it to theopposite side.●Small-sized valves capable of feeding air at a large flow rate.●Applicable to non-corrosive gases and low-viscosity liquids.
Sectional Drawings
Dimensional Drawings
CV101 to 102 CV103 to 108
CV101 to 102 CV103 to 108
Body(aluminum alloy)
Body(brass)
Poppet(nitrile rubber)
Poppet(plastic)
Spring(stainless steel)
Spring(stainless steel)
B
C
2ーA
2ーA
B
C
D
Specifications
Item
Port size
Effective sectional area
Note 1) Flow rate
Note 2) Working fluid
Working pressure range
Proof test pressure
Cracking pressure
Working temperature range
Lubrication
Weight
Model number
Air, non-corrosive gases, and hydraulic fluids having viscosity of 250×10−3 m2/s or less
1.6 MPa
0 to +80℃ (No freezing)
Unnecessary (but possible)
CV101
Rc1/8
16
1000
CV102
Rc1/4
19
1200
CV103
Rc3/8
57
3700
CV104
Rc1/2
75
4900
CV106
Rc3/4
138
9100
CV108
Rc1
225
14900
30 30 210 210 290 500
0.02 to 1 MPa0.05 to 1 MPa
0.02 MPa or less0.05 MPa or less
Parts ListModel number
Symbol B
CV101
CV102
CV103
CV104
CV106
CV108
40
45
58
58
64.5
80
A
Rc1/8
Rc1/4
Rc3/8
Rc1/2
Rc3/4
Rc1
17
17
φ31
φ31
φ40
φ49
−
−
24
27
33
40
C D
CV1 03
Series
Port size01: Rc1/8 02: Rc1/4 03: Rc3/804: Rc1/2 06: Rc3/4 08: Rc1
Unit: mm
mm2
g
ℓ/min(ANR)
Model NumberWhen placing an order, specify the model number shown below.
Ⓑ Ⓐ Ⓑ Ⓐ
Note 1) Flow rate at0.5 MPa
Note 2) The working fluid must not affect the internal rubber (nitrile rubber).
JIS symbol
The valves have twosupply ports. Air fedfrom any of thedirections Ⓐ and Ⓑcan be used as output.●Small and light.●Simple structure and long life.●Reliable operation at low pressure and at low flow rate.
Ⓐ Ⓑ
Ⓐ Ⓑ
Ⓐ Ⓑ
Ⓒ
Ⓒ
Ⓒ
Sectional Drawing
Dimensional Drawings
Body(aluminum alloy)
Valve element
D
H
EC
F
B2ーφG
(Mounting holes)
3ーA
Specifications
Air
0.05 to 1 MPa
1.5 MPa
0 to +80℃ (No freezing)
Unnecessary (but possible)
SV101
Rc1/8
8
600
SV102
Rc1/4
12
1200
60 80
Dimensional TableB
SV101
SV102
40
45
C
28
35
D
20
20
E
23
27
F
24
24
G
5.5
5.5
H
10
10
A
Rc1/8
Rc1/4
SV1 02
Series
Port size01: Rc1/802: Rc1/4
Unit: mm
Note 1) Flow rate at0.5 MPa
Item
Port size
Effective sectional area
Note 1) Flow rate
Working fluid
Working pressure range
Proof test pressure
Working temperature range
Lubrication
Weight
Model number
mm2
g
ℓ/min(ANR)
Model NumberWhen placing an order, specify the model number shown below.
Model numberSymbol
30VK
31VK
QV2 Control Equipment C
ontrol Equipment QV2
Quick Exhaust ValvePort Size: Rc1/4・Rc3/8・Rc1/2・Rc3/4・Rc1
Quick Exhaust ValvePort Size: Rc1/4・Rc3/8・Rc1/2・Rc3/4・Rc1QV2 QV2Unit: mm
EXHIN
OUT
JIS symbol
Useful for increasingactuator speed●Excellent responsibility.●Large exhaust flow rate.●Excellent durability.●Maintainable in piped state.
Sectional Drawing
EXH
Cover(aluminum alloy)
Cylinder(aluminum alloy)
Seal plate(nitrile rubber)
IN
OUT
Specifications
Air
0.2 to 1 MPa
1 MPa
+5 to +60℃
QV2−8
IN
OUT
IN↓
OUT
OUT↓
EXH
EXH
Rc1/4
32
140 140 320 800 800
34
Rc3/8
QV2−10
IN
OUT
IN↓
OUT
OUT↓
EXH
EXH
Rc3/8
47 53
Rc3/8
QV2−15
IN
OUT
IN↓
OUT
OUT↓
EXH
EXH
Rc1/2
70 110
Rc1/2
QV2−20
IN
OUT
IN↓
OUT
OUT↓
EXH
EXH
Rc3/4
110 210
Rc1
QV2−25
IN
OUT
IN↓
OUT
OUT↓
EXH
EXH
Rc1
120 230
Rc1
QV2-8
Series
Port size(IN・OUT)8: Rc1/4 10:Rc3/8 15:Rc1/2
20: Rc3/4 25:Rc1
Item
Port size
Effective sectional area
Working fluid
Working pressure range
Max. working pressure
Working temperature range
Weight
Model number
mm2
g
Model NumberWhen placing an order, specify the model number shown below.
B
AD
F
G
E
C
EXH
OUT
IN
Dimensional Table
Model number
QV2−8
QV2−10
QV2−15
QV2−20
QV2−25
IN OUT EXH
Port size Rc Major dimensions
1/4
3/8
1/2
3/4
1
1/4
3/8
1/2
3/4
1
3/8
3/8
1/2
1
1
A
50
50
67
85
85
B
43
43
53
70
70
C
56
56
73
105
105
φ43
φ43
φ51
φ72
φ72
28
28
40
50
50
34
34
41
61
61
24
24
30
46
46
D E F G
QV2
32VK
33VK
PCV Control Equipment C
ontrol Equipment PCV
Pilot Check ValvePort Size: G1/4・G3/8・G1/2・G3/4・G1
Pilot Check ValvePort Size: G1/4・G3/8・G1/2・G3/4・G1PCV PCVUnit: mm
P
A・RF
JIS symbol
The plot check valvescan stop any actuatorhalfway.●The fluid is shut at the actuator connecting port, and leakage between directional control valve and actuator does not affect the operation.●Although the pilot check valves are pneumatic devices, they can be used on hydraulic systems.●The valve element consisting of a poppet valve and a spool valve operates smoothly and does not leak.
Connecting Circuits
Model Number
Specifications
Air or hydraulic fluids having viscosity of 250×10-3 m2/s or less(Viscosity must be 250×10-3 m2/s or less at the actual min. temperature.)
PCV−02
G1/4
G1/8
10
25
PCV−03
G3/8
G1/4
32
90
PCV−04
G1/2
G1/4
36
100
PCV−06
G3/4
G1/4
160
450
PCV−10
G1
G1/4
190
540
300 800 800 2100 2100
P
A・RF
PP RR
FFA
Pilot check valve
A
PP RR
FFA
Pilot check valve
A
PCV-02
Series
Port size02: G1/4 03: G3/8 04: G1/206: G3/4 10: G1
●When actuator is operated byair pressure
●When actuator is operated by pressuretransmitter (air-oil converter)
Port A: Connected to selector valvePort P: Connected to actuatorPort R: Connected to mating check valvePort F: From mating check valve
Pressuretransmitter
●Max. flow rate when hydraulic fluid having viscosity of25×10-3 m2/s is usedItem
Port size
Effective sectional area
Max. flow rate
Working fluid
Working pressure range
Working temperature range
Cracking pressure
Weight
Body
Pilot
Model number
0.2 to 1 MPa
+5 to +60℃
0.03 MPa
mm2
ℓ/min(ANR)
g
When placing an order, specify the model number shown below.
F
Port A
Port P
Port R
Port F
F
(Only on PCV-06 and 10,port F is eccentrically positioned.)
DG
EL
JK
B
M
W
N
3-Q
M 12
H
PCV-03
MADE IN JAPAN
0.2-1MPa
P
A・RF
##################
P
R
Dimensional TableModel
number Port A
PCV−02
PCV−03
PCV−04
PCV−06
PCV−10
G1/4
G3/8
G1/2
G3/4
G1
G1/4
G3/8
G1/2
G3/4
G1
Port P Port R
G1/8
G1/4
G1/4
G1/4
G1/4
G1/8
G1/4
G1/4
G1/4
G1/4
Port F B
30
40
60
14.2
17.2
40.5
D
27
39
60
E
25.7
37.3
70.5
G
41
42
64
H
12.7
21.3
40.5
J
24.2
37.3
70.5
K
64.2
94.2
143
55
70
114
φ5.5
φ5.8
φ9
74
93
137
L
38
48
70
M N Q W
Port size Dimensions of major parts
PCV-02 PCV-03・04 PCV-06・10
A
P
R
F
AP
R
F
A
P
R
F
A
❾12
111313
❽
14
❷
❼❶❺10
❹
❸
❷
12
11
❼
13
❽
❻
❾
❶
❺
10
❹14❸
12❼❾
13
❽❻
❶
10
❺
❹14❸
❶❷❸❹❺❻❼
❽❾1011121314
NameBodyPlatePlateBushSpindlePistonDisk
JointSpringRingLeaf springSealSealLip seal
Aluminum alloy ーAluminum alloyCopper alloyStainless steel ー ー
Aluminum alloyStainless steelAluminum alloyStainless steelNitrile rubberNitrile rubberNitrile rubber
MaterialNo.
Parts ListName MaterialNo.
Note) The parts with“-”shown in the material column vary in material according to the valve type.
PCV
Sectional Drawings
❻
34VK
PCV Control Equipment
Pilot Check ValvePort Size: G1/4・G3/8・G1/2・G3/4・G1PCV
(Output)
(When discharging)
(Retention)
F
A
R
P
F
P
R
A
F
A
R
P
Flow Rate vs Pressure Drop Curves
Principle of Operation
PCV-02 PCV-04 PCV-10
PCV-03 PCV-06
0 10 20 30
0.3
0.6
0.9
Flow rate ℓ/min Flow rate ℓ/min
Flow rate ℓ/min Flow rate ℓ/min
Flow rate ℓ/min0 25 50 100
0.3
0.6
0.9
75 0 100 200 400
0.3
0.6
0.9
600300 500
0 25 50 100
0.3
0.6
0.9
75 0 200100 400
0.3
0.6
0.9
300 500
P
A・RF
The curves are based on thedata obtained when hydraulicoil of 25×10-3 m2/s was used.
Free flow in valveReverse flow
Pressure MPa
Pressure MPa
Pressure MPa
Pressure MPa
Pressure MPa
When a fluid is fed to the port A, the spindle is pressed down, and the fluid is output to the port P and the port R.When the supply to the port A is stopped, the output to the port R is stopped, and, at the same time, the spindle is pushed up by the spring force to retain the pressure at the port P.When the pilot signal is supplied to the port F, the piston presses down the spindle to discharge the pressure at the port P.