Consciousness monitoring by Wael Nasri

Post on 17-Jul-2015

90 views 0 download

Transcript of Consciousness monitoring by Wael Nasri

Wael nasri

Product&therapy spiclest Wael Nasri 1

BIS monitoring provides additional information for the

anesthesia provider by directly measuring the effects of anesthesia on your patient.

Wael Nasri 2

Overview of the TechnologyDemonstrated BenefitsClinical Applications & Special Considerations

Wael Nasri 3

Key points to remember “Remember Red”

Wael Nasri 4

BIS BackgroundTraditional Measures for Anesthesia Titration

BIS Range Guidelines

Wael Nasri 5

10+ years development cycleFirst to market a direct measure of

anesthetic effectStatistically derived from EEGLinear across EEG statesCorrelated with hypnotic endpointsPatient / drug independent

Rampil, I, Anesthesiology, Oct. 1998. Wael Nasri 6

Designed for the anesthesia providerEase of Sensor Application Processing Speed + Data presentation

Measures the effects of anesthetics in the brainEndpoint: hypnosis / consciousnessPatient & drug* independentNo calibration or baseline

Wael Nasri 7

Hemodynamic ResponsesEnd Tidal Agent MonitoringExpectations of Standard Dosages

Healthy Middle Aged MalesVariance in Metabolic & Clearance of DrugsEffects of Combined Drugs

Wael Nasri 8

Balance of Anesthesia

Analgesia Muscle Relaxation

Consciousness / HypnosisBIS

Train of FourAutonomic & Somatic Responses Wael Nasri 9

BIS

100

70

60

40

0

HYPNOTIC STATE

AWAKE / LIGHT TO MODERATE SEDATION

LIGHT HYPNOTIC STATE

Low Probability of Explicit Recall <70

MODERATE HYPNOTIC STATE

Low Probability of Consciousness <60

DEEP HYPNOTIC STATEEEG SUPPRESSIONWael Nasri 10

Less drug utilization Faster wake-up and extubation More alert and oriented patients in

PACUEarlier discharge from PACU Facilitates PACU Phase I bypassReduced PONVMonitor for risk of awareness

Wael Nasri 11

A Propofol

B Propofol

C Sevoflurane

D Desflurane

E Isoflurane

F Isoflurane

G Isoflurane

H Isoflurane

I Propofol

Reduction in Amount of AnestheticUsed in BIS Monitored Group

Ineffective: Recall Inadequate Anesthesia

Excessive: Cardiovascular Effects Prolonged Emergence Recovery Increased Drug Use $

AWAKE

FLAT LINE EEG

Optimal DepthOptimal Depthof Unconsciousnessof Unconsciousness

BIS

IN

DE

X

Awake

Light/Moderate Sedation

Deep Sedation

General Anesthesia

Deep Hypnotic State

Flat Line EEG

70

60

40

0

100

Wael Nasri 13

50

60

70

80

PRE BIS POST BIS

•Length of PACU StayLength of PACU Stay

BIS Patients Discharged 16% Faster

•N=2659N=2659 •N=2505N=2505

0

2

4

6

8

Prior to BIS Use BIS Use

PO

NV

% 6.2%

2.8%

PONV reduced>50% when BIS wasused in ambulatoryanesthesia

Intraoperative patient assessmentPatient-based titration of anesthetic agents

Reduces anesthetic drug utilization Improves specificity of drug selection

Perioperative ImprovementsFaster, more consistent emergence / extubationHigher-quality recovery / more alert patients

Effective monitor for the risk of awareness

Wael Nasri 16

BIS Applicable CasesSpecial Considerations

Sensor PlacementArtifactsPatient Movement

Wael Nasri 17

General Surgery Cardiac Surgery Out Patient Surgery MAC with Sedation

Special Procedures ICU Patients

Wael Nasri 18

Adoption Profile (“Learning Curve”)20-30 cases: Concept, Confidence, Clinical ToolReflect, not Direct, Anesthesia Care

The BIS Monitor doesn’t improve the anesthetic course / recovery doesn’t “prevent” awareness

The BIS Monitor Provides new information / perspective

Interpretation, Assessment Anesthesia Plan Agents, Doses, Timing

Wael Nasri 19

Sensor acquisition Signal Quality EMG / Artifacts Patient Movement Analgesic Vs. Hypnotic State

Wael Nasri 20

Most critical component of system!

Dual-position versatility

right or left application

Peel-place- and-press convenience

Designed to fit any adult patient

Single point monitor connection

Apply sensor on forehead at angle Circle #1: Centered, 2 inches above

nose Circle #4: Above/Adjacent to eyebrow Circle #3: Either temple between corner

of eye and hairline

Press edges of sensor Circle all 4 elements

Press each circle for 5 seconds Use fingertip Press firmly

2 Inches

Wael Nasri 23

Indicates quality of EEG signalDisplayed from 0 - 100%% of good data throughout prior 60

secondsAveraged information

Wael Nasri 24

What are they?signals generated from sources other than the

patient’s EEGexamples: bovie or noise from unshielded

equipmentBIS usually filters these out

examples: eye blinks, eye movement

Wael Nasri 25

Arises from muscle activityMore prominent as patient lightens from

anesthesiaEMG may bias the BIS to a higher value

Could be artifact or real - indicates need for troubleshooting

Increasing analgesic and/or hypnotic can reduce EMG

Wael Nasri 26

Patient Movement Analgesic Vs. Hypnotic State

Wael Nasri 27

BRAINConsciousnessMemory Function

SPINAL CORDReflex MovementAnalgesia

Eger, et al. Anesth Analg 1997;84:915-8

Dose-Response

Drug-Drug Interactions

Patient-Surgery-Response

Wael Nasri 29

BIS is not an anesthetic depth measureInformation about your patient to help in

your clinical decision-making processUse in conjunction with traditional

monitoringReliance on the BIS alone for

intraoperative anesthetic management is not recommended

Wael Nasri 30

More PatientsMore BISMore Confidence

Wael Nasri 31

Wael Nasri 32