Post on 14-Jul-2020
CO SeriesDoor Template Index
Cylindrical Lock
(Wood Door) CO-CY Cylindrical CO-100 Template - CO101
(Metal Door) CO-CY Cylindrical CO-100 Template - CO102
(Wood Door) CO-CY Cylindrical CO-200/250 Template - CO201
(Metal Door) CO-CY Cylindrical CO-200/250 Template - CO202
Mortise Lock
(Wood Door) CO-MS Mortise CO-100 Template - CO103
(Metal Door) CO-MS Mortise CO-100 Template - CO104
(Wood Door) CO-MS Mortise CO-200/250 Template - CO203
(Metal Door) CO-MS Mortise CO-200/250 Template - CO204
Mortise Deadbolt Lock
(Wood Door) CO-MD Mortise Deadbolt CO-100/200/250 Template - CO105
(Metal Door) CO-MD Mortise Deadbolt CO-100/200/250 Template - CO106
993R/S Rim & Surface Vertical Exit Device Trim
(Wood Door) CO-993R/S Exit Device CO-100/200/250 Template - CO107
(Metal Door) CO-993R/S Exit Device CO-100/200/250 Template - CO108
993M Mortise Exit Device Trim
(Wood Door) CO-993M Exit Device CO-100/200/250 Template - CO109
(Metal Door) CO-993M Exit Device CO-100/200/250 Template - CO110
993R Concealed Vertical Exit Device Trim
(Metal Door) CO-993R Exit Device CO-100/200/250 Template - CO112
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO101 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
1" (25)Dia. Hole⁵⁄₁₆" (8)
⁵⁄₁₆" (8)
¹⁄₈" (4)Pilot Hole
in two places
1⁵⁄₈"(41)
2¹⁄₈" (54)Dia. Hole
2¹⁄₄"(57)
1¹⁄₈"(29)
DoorThickness
CL
CL
CL
⁵⁄₃₂" (4)
Bevel ¹⁄₈" in 2" (3 in 51)
2³⁄₄" (70)
⁵⁄₈" (16) Dia. HoleShown from Inside(always to the right of center line whenviewed from interior)
6¹⁄₄"(159)
¹⁹⁄₃₂"(15)
⁷⁄₁₆" (11)Dia. Throughin two places
CL
6⁹⁄₃₂"(160)
2⁹⁄₃₂"(58)
1⁹⁄₆₄"(29)
For Strike dimensions, see Templates J918, J919, J928, and J929
2.750" (70) 2.750" (70)
Door edge forLH/LHR door(bevel direction will change)
Door edge forRH/RHR door
(bevel direction will change)
IMPORTANT - It is critical to identify the interior and exterior sides of door in order to correctly locate the ⁵⁄₈" hole
CO101
CO-SeriesModel CO-100-CYDoor Type: Wood or Composite, Flat or Beveled Conforms to ANSI BHMA A156.115-WDoor Thickness: 1C\,” (35 mm) – 2C\v” (70 mm)Faceplate: Square Corner, 1Z\,” (29 mm) wideBacksets: 2C\v” (70 mm), 2C\,” (60 mm), 3C\v” (95 mm), 5C\v” (146 mm)
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO102 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
CO102
1.000" (25)Dia. Hole.313" (8)
.313" (8)
.125" (4)Pilot Hole
in two places
1.625"(41)
2.125" (54)Dia. Hole
2.250"(57)
1.125"(29)
DoorThickness
CL
CL
CL
CL
6.250"(159)
.438" (11)Dia. HoleOutside onlyin two places
.625" (16) Dia. HoleOutside Only(always to the left of center line whenviewed from exterior) .625" (16) Dia. Hole
Inside only
2.280"(58)
1.140"(29)
.060"(1.5)
.261" (6)Dia. Hole Inside Onlyin two places
6.289"(160)
.590"(15)
.156" (4) ±.005
Bevel .125" in 2"(3 in 51)
1.313"(33)
1.313"(33)CL
CL
2.750" (70) 2.750" (70)
For Strike dimensions, see Templates J918, J919, J928, and J929
Door edge forLH/LHR door(bevel direction will change)
Door edge forRH/RHR door
(bevel direction will change)
IMPORTANT - It is critical to identify the interior and exterior sides of door in order to correctly locate the .625" holes
CO-SeriesModel CO-100-CYDoor Type: Metal, Flat or Beveled Conforms to ANSI/BHMA A156.115Door Thickness: 1C\,” (35 mm) – 2C\v” (70 mm)Faceplate: Square Corner, 1Z\,” (29 mm) wideBacksets: 2C\v” (70 mm), 2C\,” (60 mm), 3C\v” (95 mm), 5C\v” (146 mm)
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO103 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
CO103
CL
Outside of LH Door Inside of LH DoorDoor Edge
CL
CL
2¹⁄₈" (54)Dia. Hole
1²³⁄₃₂"(44)
2³⁄₄" (70) Door Thickness
CL
CL
1¹⁄₄" (32) or1¹⁄₁₆" (27)
4"(102)
4"(102)
Armor Front
³⁄₈"(10)
CL
Strike
of Lock
Strike
#12 - 24 WMSin two places
2"(51)
6¹⁄₄"(159)
6⁹⁄₃₂"(160)
1⁹⁄₆₄"(29)
1¹³⁄₆₄"(30.5)
1¹³⁄₆₄"(30.5)
⁷⁄₁₆" (11) Dia. HoleThrough in two places
1⁹⁄₆₄"(29)
¹⁹⁄₃₂" (15)
⁹⁄₁₆"(14)Dia. Hole1⁵⁄₈"(41)
Deepin 2 places
⁷⁄₃₂"(6) Dia. Hole
in 2 places
For Mortise Case Dimensions, see Template L1For Mortise Strike Dimensions, see Templates J918, J919, and J557
Left Hand (LH) Door Shown
⁵⁄₈" (16) Dia. HoleShown from Inside
(always to the right of center line when
viewed from interior)
IMPORTANT - It is critical to identify the interior and
exterior sides of door in order to correctly locate the ⁵⁄₈" hole
CO-SeriesModel CO-100-MSDoor Type: Wood or Composite, Flat or Beveled Conforms to ANSI BHMA A156.115-WDoor Thickness: 1C\,” (35 mm) – 2C\v” (70 mm)Faceplate: Square Corner, 1Z\zn” (27 mm) or 1Z\v” (32 mm) wideBacksets: 2C\v” (70 mm)
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO104 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
CO104
Outside of LH Door Inside of LH DoorDoor Edge
CL
2.125" (54)Dia. Hole
CL
CL1.719"(44)
1.250" (32) or1.063" (27)
4.000"(102)
4.000"(102)
Armor Front
.375"(10)
CL
Strike
of Lock
Strike
#12 - 24 WMSin two places
2.000"(51)
6.250"(159)
6.289"(160)
1.14"(29)
1.14"(29)
1.20"(30.5)
1.20"(30.5)
.438" (11)Dia. Hole
Outside Onlyin four places
CL
.261" (6) Dia. Hole
in four places
.590"(15)
.625" (16) Dia. HoleOutside OnlyShown from outside(always to the left of center line whenviewed from exterior)
.060" (1.5)
.625" (16) Dia. HoleInside Only
For Mortise Case Dimensions, see Template L1For Mortise Strike Dimensions, see Templates J918, J919, and J557Left Hand (LH) Door Shown
2.750" (70)
IMPORTANT - It is critical to identify the interior and exterior sides of door in order to correctly locate the .625" holes
CO-SeriesModel CO-100-MSDoor Type: Metal, Flat or Beveled Conforms to ANSI/BHMA A156.115 Door Thickness: 1C\,” (35 mm) – 2C\v” (70 mm)Faceplate: Square Corner, 1Z\zn” (27 mm) or 1Z\v” (32 mm) wideBacksets: 2C\v” (70 mm)
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO105 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
CO105
CL
Outside of LH Door Inside of LH DoorDoor Edge
CL
B
CL
2¹⁄₈" (54)Dia. Hole
1²³⁄₃₂"(44)
2³⁄₄" (70) Door Thickness
C
CL
CL
1¹⁄₄" (32) or1¹⁄₁₆" (27)
4"(102)
4"(102)
Armor Front
³⁄₈"(10)
CL
Strike
A
of Lock
Strike
#12 - 24 WMSin two places
⁵⁄₈" (16)Dia. Hole1¹⁄₄" (32)
Deep
2²³⁄₃₂"(18)
2"(51)
6¹⁄₄"(159)
6⁹⁄₃₂"(160)
1⁹⁄₆₄"(29)
1¹³⁄₆₄"(30.5)
1¹³⁄₆₄"(30.5)
⁷⁄₁₆" (11) Dia. HoleThrough in two places
1⁹⁄₆₄"(29)
¹⁹⁄₃₂" (15)
⁹⁄₁₆"(14)Dia. Hole1⁵⁄₈"(41)
Deepin 2 places
⁷⁄₃₂"(6) Dia. Hole
in 2 places
For Mortise Case Dimensions, see Template L1For Mortise Strike Dimensions, see Templates J918, J919, and J557
Left Hand (LH) Door Shown
⁵⁄₈" (16) Dia. ThroughShown from Inside(always to the right of center line whenviewed from interior)
IMPORTANT - It is critical to identify the interior and exterior sides of door in order to correctly locate the ⁵⁄₈" hole
CO-SeriesModels CO-100/200/250-MDDoor Type: Wood or Composite, Flat or Beveled Conforms to ANSI BHMA A156.115-WDoor Thickness: 1C\,” (35 mm) – 2C\v” (70 mm)Faceplate: Square Corner, 1Z\zn” (27 mm) or 1Z\v” (32 mm) wideBacksets: 2C\v” (70 mm)
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO106 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
CO106
Outside of LH Door Inside of LH DoorDoor Edge
CL
2.125" (54)Dia. Hole
2.750" (70) Door Thickness
CL
CL1.719"(44)
1.250" (32) or1.063" (27)
4.000"(102)
4.000"(102)
Armor Front
.375"(10)
CL
Strike
of Lock
Strike
#12 - 24 WMSin two places
2.000"(51)
6.250"(159)
6.289"(160)
1.14"(29)
1.14"(29)
1.20"(30.5)
1.20"(30.5)
.438" (11) Dia. HoleOutside Onlyin four places
CL
.625" (16)Dia. Hole
InsideOnly
2.718"(18)
.261" (6) Dia. Hole
in four places
.590"(15)
.625" (16)Dia. HoleOutsideOnly
.060" (1.5)
.625" (16) Dia. HoleInside Only
For Mortise Case Dimensions, see Template L1For Mortise Strike Dimensions, see Templates J918, J919, and J557
Left Hand (LH) Door Shown
.625" (16) Dia. HoleOutside OnlyShown from outside(always to the left of center line whenviewed from exterior)
IMPORTANT - It is critical to identify the interior and exterior sides of door in order to correctly locate the .625" holes
CO-SeriesModels CO-100/200/250-MDDoor Type: Metal, Flat or Beveled Conforms to ANSI/BHMA A156.115 Door Thickness: 1C\,” (35 mm) – 2C\v” (70 mm)Faceplate: Square Corner, 1Z\zn” (27 mm) or 1Z\v” (32 mm) wideBacksets: 2C\v” (70 mm)
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO107 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
CO107
Note 1:For Backset, See Applicable Von Duprin 98-R/99-R, 9827/9927, 22-R, or 2227 Series Exit Device Template.
Outside of LHR Door(Pull Side)
Inside of LHR Door(Push Side)
Door Edge
CL
Door Thickness
2¹⁄₈” (54)Dia. Hole(NL Input)
²¹⁄₃₂"(17)
6¹⁸⁄₃₂"(166)
⁵⁄₈" (16)Dia. Hole1¹⁄₄" (32)
Deep
⁵⁄₈" (16)Dia. Hole1¹⁄₄" (32)
Deep
CLof Device
CLof Device
¹⁄₂" (13) Dia.Angled Hole toConnect Holes
Backset(See Note 1)
Left Hand Reverse (LHR) Door Shown
of Device
CL
¹⁹⁄₃₂" (15)Always to the Right of the Center Line
¹⁹⁄₃₂" (15)Always to the Left of the Center Line
6¹⁄₁₆"(154)
98/99 Exit Device Holes in 4 places
for Reference Only
⁹⁄₁₆"(14) Dia. Hole1⁵⁄₈"(41) Deep
in 2 places
¹⁄₄"(6) Dia. Hole
in 2 places
¹⁄₄"(6) Dia. Hole
in 2 places
⁵⁄₃₂" (4) Dia. Hole 1" (25) Deepin 2 places
14¹¹⁄₃₂"(364)
6¹⁄₄"(159)
1⁹⁄₆₄"(29)
1⁹⁄₆₄"(29)
1⁹⁄₆₄"(29)
1⁹⁄₆₄"(29)
1¹³⁄₆₄"(30)
1¹³⁄₆₄"(30)
⁹⁄₁₆"(14) Dia. Hole
in 2 places
CO-SeriesModels CO-100/200/250-993R/SDoor Type: Wood Exit Devices: Rim, Surface VerticalDoor Thickness: 1C\v” (44 mm) – 2C\v” (70 mm)Faceplate: NoneBacksets: Various
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO108 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
CO108
Note 1:For Backset, See Applicable Von Duprin 98-R/99-R, 9827/9927, 22-R, or 2227 Series Exit Device Template.
A
CL
B
Door Thickness
2.125” (54)Dia. Hole(NL Input)
.650"(17)
6.555"(166)
.625" (16)Dia. Hole
.625" (16)Dia. Hole
CLof Device
CLof Device
Backset(See Note 1)
Left Hand Reverse (LHR) Door Shown
of Device
CL
.590" (15)Always to the Right of the Center Line
.590" (15)Always to the Left of the Center Line
6.070"(154)
98/99 Exit Device Holes
in 4 places for Reference Only
.563" (14) Dia. Hole in 2 places
.261" (6) Dia. Hole
in 2 places
.261" (6) Dia. Hole
in 2 places
#25 Drill#10-24 Tapin 2 places
14.337"(364)
6.250"(159)
C
1.140"(29)
1.140"(29)
1.140"(29)
1.140"(29)
1.200"(30)
1.200"(30)
.563" (14) Dia. Hole
in 2 places
Outside of LHR Door(Pull Side)
Inside of LHR Door(Push Side)
Door Edge
CO-SeriesModels CO-100/200/250-993R/SDoor Type: Metal Exit Devices: Rim, Surface VerticalDoor Thickness: 1C\v” (44 mm) – 2C\v” (70 mm)Faceplate: NoneBacksets: Various
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO109 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
CO109
CL
Door Thickness
2¹⁄₈” (54)Dia. Hole(NL Input)
²¹⁄₃₂"(17)
6¹⁸⁄₃₂"(166)
⁵⁄₈" (16)Dia. Hole1¹⁄₄" (32)
Deep
⁵⁄₈" (16)Dia. Hole1¹⁄₄" (32)
Deep
CLof Device
CLof Device
¹⁄₂" (13) Dia.Angled Hole toConnect Holes
¹⁹⁄₃₂" (15)Always to the Right of the Center Line
¹⁹⁄₃₂" (15)Always to the Left of the Center Line
See Note 1 ¹⁄₄"(6)
Dia. Hole in 2 places
¹⁄₄"(6) Dia. Hole
in 2 places
⁵⁄₃₂" (4) Dia. Hole 1" (25) Deepin 2 places
14¹¹⁄₃₂"(364)
6¹⁄₄"(159)
1⁹⁄₆₄"(29)
1⁹⁄₆₄"(29)
1⁹⁄₆₄"(29)
1⁹⁄₆₄"(29)
1¹³⁄₆₄"(30)
1¹³⁄₆₄"(30)
⁹⁄₁₆"(14) Dia. Hole
in 2 places
of DeviceCLCL
¹¹⁄₃₂"(9)
1³⁄₈"(35)
Note 1:For Mortise Lock and Mortise Exit Device PreparationSee Von Duprin 98/9975 Series Templates
See Note 1
2³⁄₄" (70)
of Mortise Lock
Outside of LHR Door(Pull Side)
Inside of LHR Door(Push Side)
Door Edge
6¹⁄₁₆"(154)
⁹⁄₁₆"(14) Dia. Hole1⁵⁄₈"(41) Deep
in 2 places
Left Hand Reverse (LHR) Door Shown
CO-SeriesModels CO-100/200/250-993MDoor Type: Wood Exit Devices: MortiseDoor Thickness: 1C\v” (44 mm) – 2C\v” (70 mm)Faceplate: NoneBacksets: Various
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO110 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
CO110
A
CL
B
Door Thickness
2.125” (54)Dia. Hole(NL Input)
.650"(17)
6.555"(166)
.625" (16)Dia. Hole
.625" (16)Dia. Hole
CLof Device
CLof Device
Left Hand Reverse (LHR) Door Shown
.590" (15)Always to the Right of the Center Line
.590" (15)Always to the Left of the Center Line
98/99 Exit Device Holes in 4 places
for Reference Only .563"(14) Dia. Hole
in 2 places
.261" (6) Dia. Hole
in 2 places
.261" (6) Dia. Hole
in 2 places
.159" (4) Dia. Hole in 2 places
14.337"(364)
6.250"(159)
C
1.140"(29)
1.140"(29)
1.140"(29)
1.140"(29)
1.200"(30)
1.200"(30)
.563" (14) Dia. Hole
in 2 places
of DeviceCLCL
.344"(9)
1.375"(35)
Note 1:For Mortise Lock and Mortise Exit Device PreparationSee Von Duprin 98/9975 Series Templates
See Note 1
2.750" (70)
of Mortise Lock
Outside of LHR Door(Pull Side)
Inside of LHR Door(Push Side)
Door Edge
6.070"(154)
CO-SeriesModels CO-100/200/250-993MDoor Type: Metal Exit Devices: MortiseDoor Thickness: 1C\v” (44 mm) – 2C\v” (70 mm)Faceplate: NoneBacksets: Various
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO112 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
CO112
.750" (19)Dia. Hole
Outside of LHR Door(Pull Side)
Inside of LHR Door(Push Side)
Door Edge
CL
Door Thickness
2.125” (54)Dia. Hole(NL Input)
.650"(17)
6.555"(166)
.625" (16)Dia. Hole
.625" (16)Dia. Hole
CLof Device
CLof Device
Backset(See Note 1)
of Device
CL
.590" (15)Always to the Right of the Center Line
.590" (15)Always to the Left of the Center Line
98/99 Exit Device Holes in 4 places
for Reference Only
.563"(14) Dia. Hole
.261" (6) Dia. Hole
in 2 places
.261" (6) Dia. Hole
in 2 places
14.337"(364)
6.250"(159)
1.140"(29)
1.140"(29)
1.140"(29)
1.140"(29)
1.200"(30)
1.200"(30)
.563"(14) Dia. Hole
in 2 places
Left Hand Reverse (LHR) Door Shown
Note 1:For backset and exit device cutouts, see Von Duprin 9847/9947 series exit device templates.
#25 Drill#10-24 Tapin 2 places
6.070"(154)
CO-SeriesModels CO-100/200/250-993RDoor Type: Metal Exit Devices: Concealed VerticalDoor Thickness: 1C\v” (44 mm) – 2C\v” (70 mm)Faceplate: NoneBacksets: Various
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO201 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
1" (25)Dia. Hole⁵⁄₁₆" (8)
⁵⁄₁₆" (8)
¹⁄₈" (4)Pilot Hole
in two places
1⁵⁄₈"(41)
2¹⁄₈" (54)Dia. Hole
2¹⁄₄"(57)
1¹⁄₈"(29)
CL
CL
CL
¹⁄₂" (13)Dia. Hole
x1¹⁄₄" DeepInside only(for DPS*)
⁵⁄₈" (16) Dia. HoleShown from Inside(always to the right of center line whenviewed from interior)
6¹⁄₄"(159)
¹⁹⁄₃₂" (15)⁷⁄₁₆" (11)
Dia. Throughin two places
6⁹⁄₃₂"(160)
2⁹⁄₃₂"(58)
1⁹⁄₆₄"(29)
For Strike dimensions, see Templates J918, J919, J928, and J929
2.750" (70) 2.750" (70)
Door edge forLH/LHR door(bevel direction will change)
Door edge forRH/RHR door
(bevel direction will change)
*DPS only required for 40 Function (Privacy)
IMPORTANT - It is critical to identify the interior and exterior sides of door in order to correctly locate the ⁵⁄₈" hole
DoorThickness
⁵⁄₃₂" (4)
Bevel ¹⁄₈" in 2" (3 in 51)
CL
Backset
6⁵⁄₈"(168)
³⁄₄" (19) Dia. Holex 1¹⁄₂" (38) Deep
(for DPS*) ³⁄₈" (10)Dia. Hole in center
of door at45 degree angle
(Connects DPS* Holes)If larger backset, modify
angle accordingly
3⁵⁵⁄₆₄"(98)
CO201
CO-SeriesModels CO-200/250-CYDoor Type: Wood or Composite, Flat or Beveled Conforms to ANSI BHMA A156.115-WDoor Thickness: 1C\,” (35 mm) – 2C\v” (70 mm)Faceplate: Square Corner, 1Z\,” (29 mm) wideBacksets: 2C\v” (70 mm), 2C\,” (60 mm), 3C\v” (95 mm), 5C\v” (146 mm)
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO202 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
CO202
1.000" (25)Dia. Hole.313" (8)
.313" (8)
.125" (4)Pilot Hole
in two places
1.625"(41)
2.125" (54)Dia. Hole
2.250"(57)
1.125"(29)
DoorThickness
CL
CL
CL
BA
CL
6.250"(159).500" (13)
Dia. HoleInside only(for DPS*)
.438" (11)Dia. HoleOutside onlyin two places
.625" (16) Dia. HoleOutside Only(always to the left of center line whenviewed from exterior) .625" (16) Dia. Hole
Inside only
2.280"(58)
1.140"(29)
.060"(1.5)
.261" (6)Dia. Hole Inside Onlyin two places
6.289"(160)
.590"(15)
.156" (4) ±.005
Bevel .125" in 2"(3 in 51)
C
1.313"(33)
1.313"(33)CL
CL
2.750" (70) 2.750" (70)
For Strike dimensions, see Templates J918, J919, J928, and J929
.750" (19)Dia. Hole(for DPS*)
6.625"(168)
Door edge forLH/LHR door(bevel direction will change)
Door edge forRH/RHR door
(bevel direction will change)
*DPS only required for 40 Function (Privacy)
IMPORTANT - It is critical to identify the interior and exterior sides of door in order to correctly locate the .625" holes
3.859"(98)
CO-SeriesModels CO-200/250-CYDoor Type: Metal, Flat or Beveled Conforms to ANSI/BHMA A156.115Door Thickness: 1C\,” (35 mm) – 2C\v” (70 mm)Faceplate: Square Corner, 1Z\,” (29 mm) wideBacksets: 2C\v” (70 mm), 2C\,” (60 mm), 3C\v” (95 mm), 5C\v” (146 mm)
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO203 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
CO203
CL
Outside of LH Door Inside of LH DoorDoor Edge
CL
CL
2¹⁄₈" (54)Dia. Hole
³⁄₄" (19)Dia. Hole(for DPS*)
3⁵⁵⁄₆₄"(98)
1²³⁄₃₂"(44)
2³⁄₄" (70)
CL
CL
1¹⁄₄" (32) or1¹⁄₁₆" (27)
4"(102)
4"(102)
Armor Front
³⁄₈"(10)
CL
Strike
of Lock
Strike
#12 - 24 WMSin two places
2"(51)
6¹⁄₄"(159)
6⁹⁄₃₂"(160)
1⁹⁄₆₄"(29)
1¹³⁄₆₄"(30.5)
1¹³⁄₆₄"(30.5)
1⁹⁄₆₄"(29)
¹⁹⁄₃₂" (15)
⁹⁄₁₆"(14)Dia. Hole1⁵⁄₈"(41)
Deepin 2 places
⁷⁄₃₂" (6) Dia. Hole
in 2 places
For Mortise Case Dimensions, see Template L1For Mortise Strike Dimensions, see TemplatesJ918, J919, and J557Left Hand (LH) Door Shown
⁵⁄₈" (16) Dia. Hole Shown frominside (always to the right of center line when viewed from interior)
*DPS only required for 40 Function (Privacy)
IMPORTANT - It is critical to identify the interior and exterior sides of door in order to correctly locate the ⁵⁄₈" hole
³⁄₄" (19) Dia. Hole x 1¹⁄₂" (38) Deep (for DPS*)
7"(178)
⁷⁄₁₆" (11) Dia. HoleThroughin two places
*³⁄₈" (10)Dia. Hole in center
of door at45 degree angle
(DPS wiring clearancechannel)
CO-SeriesModels CO-200/250-MSDoor Type: Wood or Composite, Flat or Beveled Conforms to ANSI BHMA A156.115-WDoor Thickness: 1C\,” (35 mm) – 2C\v” (70 mm)Faceplate: Square Corner, 1Z\zn” (27 mm) or 1Z\v” (32 mm) wideBacksets: 2C\v” (70 mm)
Dimensions shown in parentheses () are in millimeters.
© 2017 AllegionCO204 Rev. 05/14www.allegion.com/us
Door preparation template
Return to Index
CO204
Outside of LH Door Inside of LH DoorDoor Edge
CL
2.125" (54)Dia. Hole
.750" (19)Dia. Hole(for DPS*)
3.859"(98)
CL
CL1.719"(44)
1.250" (32) or1.063" (27)
4.000"(102)
4.000"(102)
Armor Front
.375"(10)
CL
Strike
of Lock
Strike
#12 - 24 WMSin two places
2.000"(51)
6.250"(159)
6.289"(160)
1.14"(29)
1.14"(29)
1.20"(30.5)
1.20"(30.5)
.438" (11)Dia. Hole
Outside Onlyin four places
CL
.261" (6) Dia. Hole
in four places
.590"(15)
.625" (16) Dia. HoleOutside OnlyShown from outside(always to the left of center line whenviewed from exterior)
.060" (1.5)
.625" (16) Dia. HoleInside Only
For Mortise Case Dimensions, see Template L1For Mortise Strike Dimensions, see Templates J918, J919, and J557Left Hand (LH) Door Shown
.750" (19)Dia. Hole(for DPS*)
7.000"(178)
2.750" (70)
*DPS only required for 40 Function (Privacy)
IMPORTANT - It is critical to identify the interior and exterior sides of door in order to correctly locate the .625" holes
CO-SeriesModels CO-200/250-MSDoor Type: Metal, Flat or Beveled Conforms to ANSI/BHMA A156.115 Door Thickness: 1C\,” (35 mm) – 2C\v” (70 mm)Faceplate: Square Corner, 1Z\zn” (27 mm) or 1Z\v” (32 mm) wideBacksets: 2C\v” (70 mm)