Transcript of CLIMATE ADAPTATION, INNOVATIVE SUDS AND PROTECTION OF HARRESTRUP Å By Sille Lyster Larsen, Grontmij...
- Slide 1
- CLIMATE ADAPTATION, INNOVATIVE SUDS AND PROTECTION OF
HARRESTRUP By Sille Lyster Larsen, Grontmij & Vinni Rnde, MSc
Hydrology, Wageningen UR Retrofitting Baunebakken, Hvidovre 1
- Slide 2
- Hvidovre Introduction 2 2 l/s/ha
- Slide 3
- What was done Increased permeable surface -Hydraulic model
-Calibration with flow and rainfall measurements -Terrain analysis
-Is subsurface flow possible? -Designing the SuDS -Iterative design
process: design and functionality -Public involvement in
Baunebakken -Creating ownership and getting feedback -Cost analysis
-Testing traditional pipes versus SuDS 3
- Slide 4
- Retrofitting the system 4
- Slide 5
- Rain gardens and filter trench 5
- Slide 6
- Design of rain gardens Grundkr 6: Filling material: soil
Drainage: pipe Size: 1,5x1,5m Vegetation: plants Grundkr 8: Filling
material: Top: soil Btm: pebble gravel Drain: gravel spillway Size:
2x2m Vegetation: plants Grundkr 10: Filling material: Top:
soil/stones Btm: pepple gravel Drain: stone well Size: 1,5x2m
Vegetation: grass Grundkr 4: Filling material: soil Drain: pipe and
gravel spillway Size: 1,5x1,5m Vegetation: plants 6
- Slide 7
- Plan view of rain gardens Outlet to sewer network roof 7 Rain
garden
- Slide 8
- Plan view of experimental setup roof Outlet to sewer network
Inlet Location of flow measurements 8 Rain garden roof
- Slide 9
- Method: Irrigation experiment Rainfall events Return period
(year) Duration (min) Climate factor Intensity (L/s/ha) 5101193
10201,43226 Water from fire hydrant was sprayed on the roofs with
flow rates equal to: 9
- Slide 10
- Method: water level measurements soil pebble gravel drain pipe
short piezometer for surface water measurements gravel spillway
long piezometer for water level measure- ments in the bottom 75mm
pipe trench water from roof permeable membrane diver 80cm 10
- Slide 11
- Results: Grundkr 4 -Drain pipe not in use during the 5-year
return period event -Overflow during 10-year return period event
11
- Slide 12
- Results: Grundkr 6 -Overflow during 5- and 10-year return
period events -Lekage to penetrating piezometer error in bottom
water level 12
- Slide 13
- Results: Grundkr 8 -Overflow during 5- and 10-year return
period events -Design error: level of spillway higher than level of
lowest edge of rain garden 13
- Slide 14
- Results: Grundkr 10 -No overflow -OBS: Reduced flow to rain
garden due to overflow of rain gutter 14
- Slide 15
- Summary of results -Volume capacity of rain gardens was far
from reached during a 5- and 10-year return period of 10 and 20 min
duration, respectively. -Infiltration is the limiting factor in
rain gardens with plants Ponding and overflow occurred -Direct
comparison of rain gardens is difficult o uncertainty in flow o
design errors o variation in ratio roof area / rain garden area
15
- Slide 16
- Final design of rain gardens The grass rain garden: -Rain
garden similar to that at Grundkr 10 -Reduction of depth from 80 to
50 cm (decrease of material expenses) The plant rain garden: -Rain
garden similar to that at Grundkr 4 -A drainpipe has been excluded
due to risk of clogging in the long run With these designs the rain
gardens are able to convey a 5-year return period rain of 10 min
duration 16
- Slide 17
- Conclusion -Climate change adaptable system -The required
volume was found through decentralized SuDs elements -Runoff
delayed to 2 L/s/ha protection of Harrestrup -Lower cost than a
traditional pipe design 17
- Slide 18
- Conclusion -The overall design is being implemented and
expected to be completed by August/September 2014 18
- Slide 19
- Thank you 19 -Vinni Rnde, vikar@student.dtu.dk -Sille Larsen,
sll@grontmij.dk