Casing Beads for Stucco/Plaster - Plastic Components · Casing Beads for Stucco/Plaster 3.5"...

Post on 27-Jun-2020

3 views 0 download

Transcript of Casing Beads for Stucco/Plaster - Plastic Components · Casing Beads for Stucco/Plaster 3.5"...

9051 NW 97th Terrace. Miami, FL 33178 800.327.7077 • Fax 305.887.2452 • www.plasticomponents.com©2006_REV 2020 Plastic Components Inc.

Insta

llatio

n In

stru

ctions

Arched Casing BeadUncut, the arched casing bead canbe used for straight and standardstucco casing bead applications. To install

1 Cut the pre-slotted flange to convert this stucco casing bead into an arched casing bead.2 Attach to the substrate with approved fasteners, construction adhesive or tie wire to the lath as specified by the architect, ASTM C1063, ASTM C926 and ASTM D1784, local building code, and industry standards.

Casing Beads for Stucco/Plaster

3.5" Foundation Casing BeadUse at the stem wall/foundation lineto control moisture penetration.

To install

1 Attach to the substrate with the flange overlapping and extending below the stem wall/foundation line.2 Install the moisture barrier and lath so that they overlap the top of the casing bead flange.

Plastic Components’ CasingBeads create a termination point inmany areas when applying exteriorcoating materials. They protect thecoating with a straight, rustproof,high-impact resistant edge. Casingbeads are versatile components thatcan be used on walls to create aes-thetically shaped details anddesigns, such as bands and archesaround windows and doors.

Available in sizes to create stuccoground thicknesses from 1/4 inch (6 mm) to 2 inches (51 mm).

To install1 Cut the casing bead to length to fit the designed detail.2 Attach to the substrate with approved fasteners, construction adhesive or tie wire to the lath as specified by the architect, ASTM C1063, ASTM C926 and ASTM D1784, local building code, and industry standards.3 Use a plumb line or level to check and maintain a straight line application during attachment. Shim as necessary to maintain a continuous straight edge.4 Moisture barrier shall be specified and installed per the design professional.

Wall

Foundation

Pre-slotted Flanges

Casing Bead

MoistureBarrier

Self-furredULTRA-LATH®

Caulk all butt joints, intersections and ends at time of installation using an elastomeric sealant such as Plastic Components’ Ultra-Tech™ (PC-ULTW).