Case study U-Value of barrel vault ceiling Reflexy Nederland

Post on 08-Mar-2016

218 views 2 download

Tags:

description

 

Transcript of Case study U-Value of barrel vault ceiling Reflexy Nederland

Aerogel Composite Improves U-Value of Barrel Vault Ceiling

Floor to ceiling height conserved in museum

C A S E S T U D Y

Location: Imperial War Museum, London Fabrication Partner: The Proctor Group

Provide ceiling insulation for Barrel Vault area of Imperial War Museum in London. This area was overheating in the summer and very cold in the winter.Improve u-value to below 0.2W/m2K, while not reducing the floor to ceiling height.

The Proctor Group installed 20 mm of its Spacetherm blanket insulation on the ceiling. Spacetherm is a composite of Spaceloft® insulation and fibrous matting. It has a thermal conductivity of only 0.013W/mk, enabling high thermal performance in a thin, flexible blanket.

Spacetherm achieved a u-value of 0.18W/m2K, which exceeded the specification.Spacetherm’s 20 mm thickness barely reduced the floor to ceiling height.

••

••

CHALLENGES

DETAILS

SOLUTIONS

BENEFITS

Aspen Aerogels, Inc.30 Forbes Road, Building BNorthborough, MA 01532USA

Aspen Aerogels and Spaceloft are registered trademarks of Aspen Aerogels, Inc.© 2011 Aspen Aerogels, Inc.

REV 1.0

Phone:Fax:E-Mail:Web:

508.691.1111508.691.1200info@aerogel.comwww.aerogel.com

Spaceloft - High Performance Insulation for Building Envelopes