Case study - Morocco solar system · Thermal driven Separation Processes Case study of Memsys Solar...

Post on 26-Jan-2020

3 views 0 download

Transcript of Case study - Morocco solar system · Thermal driven Separation Processes Case study of Memsys Solar...

Thermal driven

Separation

Processes

Case study of Memsys Solar

Desalination System in Morocco

Memsys Water Technologies GmbH

Fuggerstraße 33, 86830 Schwabmünchen, Germany

+49 (0) 823 2807 9549

+65 91011205

Contact@memsys.eu

Kui.zhao@memsy.eu

2www.memsys.eu

Location and partner

Location: Ben Guerir, Moroco

Partner: Green energy park, Morocco,

http://www.greenenergypark.ma/

Memsys solar system

3www.memsys.eu

System layout

PV cells

� House�

4www.memsys.eu

Inside the “House”

RO system

with

pretreatment

Memsys

system

5www.memsys.eu

Memsys system

memsys

• 4 effect;

• 6.4 m2 membrane area;

• 20~50 l/h distillate water;

• Operating temperature 75~80 oC�

6www.memsys.eu

Process diagram

PV: 64 m2, 10 kW

MemsysRO

500 L

water

tank

Solar collector: 30

m2, 15 kW, 90 oC

RO brine,

1.5 m3/h

Product clean water,

7.8~8 m3/h

Final brine to discharge,

1~1.2 m3/h

Underground

water, 9 m3/h

0.3~0.5 m3/h7.5 m3/h

Container

(modified)

7www.memsys.eu

Operation data

• Solar heating temperature to

memsys is depended on the

weather;

• In a normal day in March, we can

get ave. 70 oC hot water to run

the MD system;

• The memsys system can produce

25~40 l/h distillate water;