By: Jim WilliamsPresident

Arizona Superior Coatings

P.O. Box 385Vail, AZ85641

(520) 647 - 7672jim@arizonasuperiorcoatings.comwww.arizonasuperiorcoatings.com

SUPER THERM®

SP SEAL COAT

HSC 1000™ (hot surface coat)

iSTUCCO SYSTEM

SUPER THERM®Thermal Barrier Ceramic Coating

SUPER THERM® is a ceramic based, water borne, thermal barrier coating that is designed to block and reflect heat that increases energy and maintenance cost. As the only ceramic coating developed in cooperation with NASA, SUPER THERM® is the most effective, durable, and long lasting ceramic coating on the market.

30%

It has 4 unique ceramic compounds which :

Block 95% of Solar Heat

Insulate

Heat Sources from the Sun

57%

3%

40% Infrared

Ultraviolet

Visable Light

99.5% Infrared

99% Ultraviole

t

92% Visible Light

Properties of Cool Roofing Materials

Definitions

• Solar Reflectivity– Amount of incoming solar energy a material reflects (usually in %)

• Emissivity– Amount of energy a material emits due to its own heat and

temperature (usually in %)

roof

sunreflected emitted

• Fear of glare Super Therm® produces diffused

reflections, not secular reflections

secular diffuse

14

Nippon Paint Factory Roof Insulation

Heat Loss Captured by Infrared Camera BEFORE

Application of Super Therm®

15

Residential HomeLittle Rock, Arkansas

UNIQUE CERAMIC COMPOSITION

Blend of four different ceramics that block all windows of heat transfer.

Other ceramic coatings only contain glass hollow spheres that reflect visual light when clean but absorb and transfer other windows of heat.

Only ceramic coating rated as an insulator by BOCA (Us Building Code).

Includes various resins, including urethanes for durability and longevity.

Rain Moisture Humidity

Protection from the elements

Dampens sound waves

Super Therm™

68% reduction

Super Therm® is rated as a true insulator by BOCA (US Building Code)

R19 equivalent rating

Super Therm™= 6” – 8”

10 mil dry

ASHRAE 90.1 CODE COMLIANCE

TESTING REQUIRED TO PROVE THE RE VALUE

A. ASTM C 236-89 “ Standard Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box.”

B. ASTM 1269 “Differential Scanning Calorimeter”

ASTM E 1461-92 “Thermal Diffusivity.”

Super Therm® has a “U” ( Thermal Flow) Value of 0.052.

Super Therm® is (1/RE) = 0.052 Thermal Flow. ASHRAE 90.1 Compliance Varrience cannot exceed 0.061 for Thermal Flow.

Super Therm® falls within the ASHRAE 90.1 Compliance Rating and is acceptable.

Class A Fire Rating

Super Therm™

Prevents Mold and Mildew

USDA Approved

Certified Water Barrier (ASTM D 7088, ASTM D 6904)

Super Therm™

Environmentally Friendly (24 grams per liter VOC)

Very Long Life Expectancy

20 Years

Extraordinary elasticity

Passed ASTM E1737

Roof Insulation

Topside Underside

Concrete Insulation

walls floors

Sound proofing

Ice Machines Elevators

Building Envelope

Air Conditioning & Ducting

AC Units AC Ducting

39

Before Super Therm® Application Saw

Tooth Section Built 1937

After Super Therm® Application

187,000 Sq.Ft. of Metal and 82,000 Sq.Ft. of Tar & Gravel

Chicago Bridge & Iron Company

Beaumont, Texas

40

Nissan Motor Co. Ltd.Yokahama, Japan

200,000 Sq. Meters

BeforBeforee

AfteAfterr

Tucson Intl. Airport Tucson, AZ

Super Therm® was applied toCentral PlantWest ConcourseEast ConcourseWash BaysNote:A power wash and thorough

cleaning was performed on all roof tops prior to application

Tucson International Airport

August 2009 Savings = $22,144Chris Wilt - Senior Director Facility Development

RESIDENTIAL HOME TUCSON, AZ

Super Therm® was applied toRoof TopFront Porch CoverBack Patio CoverSP Seal Coat was used on

all water channels and crickets

All penetrations were sealed prior to Super Therm®

70 degrees

77 degrees

BEFORE CIRCLE K TUSCON, AZ

AFTER CIRCLE K TUCSON, AZ

TRUMP INTERNATIONAL FT. LAUDERDALE, FL

Super Therm® was applied toConcrete ceiling of lobbyConcrete ceiling of parking

structure under air conditioned space

SANTA ROSA DUNES PENSACOLA, FL

48

Bel-Air Condos in Austin, Texas

SPI iStucco™ System

Thermal Scan BEFORE iStucco™ System

iSTUCCO System Before

Ceramic Stucco Application

iStucco After Super Therm®

Frito Lay Trailer, KY Trailer

Irvington Elementary School, KY

55

Apartent Buildings And HotelIn Munich Germany

56

Residential HomeLas Vegas, Nevada

Approved and accepted with Energy Star for saving energy.

ASTM E 903-96 Reflectivity=80%Only 1% Reduction in Reflectivity over 3

Years (3% over 10 years)

ENERGY STAR Program

B 117/D 1654 450 Hour Salt Spray (Fog) – Passed

C 177 thermal conductivity testing – PassedC 236 (C236-89(1993)el) – Passed, our

performed fiberglass by 148%.– Standard Test Method for Steady-State Thermal

Performance of Building Assemblies by means of Guarded Hot Box. Testing for measuring R-values.

C 411 High – Temperature Surface Performance – Passed

D 412 Tensile strength – Passed– .041 thickness = 13,248 psi

ASTM Testing

ASTM Testing cont’d…

D 522 – Passed– Resistance to cracking on metal or rubber type

materials. 1” (25mm)bend. ¼”(96mm)bendD 1653 Water Vapor Permeability – PassedD 1654 Salt spray (fog/weathering) – Passed –

2000 hoursD 3273-82T D 3274 – Passed

– Resistance to fungal growth or soil and dirt accumulation on paint film. Excellent (8 out of 9)

D 4060 Abrasion Resistance – PassedE 84 Flame Spread / Smoke Developed – Passed

– Class “A” Rating (or Class “1” or Class “I”)

ASTM Testing cont’d…

E84-89a Flame spread / Smoke Developed – Passed – “0” development– Flame Index “0”. Smoke Index “0”

E96 water vapor transmission – Passed – less than .01 E 96 water vapor transmission – Passed – less than .01 E 903-96 Reflectance – Passed E 119 Structural Steel Fire curve – Passed – 25 minutes E 1269 Thermal penetration through a substrate by

differential scanning calorimeter – Passed – blocking 99% of heat BTU conduction – TPRL

ASTM Testing cont’d…

E 1461-92 Laser flash technique conductivity diffusivity – Passed

VTEC Laboratories review of test results – Letter stating RE19

TPRL lab test results show a bare metal plate allowing 367.20 BTU heat conduction. SUPER THERM® coated on metal plate allowed only 3.99 BTU heat gain. A 99% reduction in heat transfer after applying only one coat of SUPER THERM ® on test plate.

G53 exposure to UV, elevated temperature and humidity - Passed

ICC Approval (International Code Councel) 0104

Passed – ID #21-25Council that formally consolidates approvals

for BOCA (Building Officials Code Administrators)– Section 723.2 Exposed installations, Thermal insulation– Section 723.3 Concealed installations, Thermal

insulation– Section 803.2 Classification, Interior finish– 1998 International Mechanical Code– Section 604.3 Coverings and Linings, Insulation

ICBO (International Conference of Building Officials)

Passed ASTM E 84 For Flame SpreadPassed ASTM C 411 for High Temperature for

Surface PerformancePassed ASTM C 177 for Thermal Conductivity

(*SUPER THERM Specific)

NASA

NHB 8060.1B/C Test 1 Flammability testing – Passed

“0” Burn, Class “A” rating – PassedNHB 8060.1C, Test 7 Toxic Off gassing –

Passed“K” no Toxic off gassing – Passed“K” Rating for toxicity – PassedTests performed at Marshall Space Flight

Center

Key Endorsements

USDA• Passed

– Environmentally safe and safe for use around animals– Approved for incidental food contact– Letter of Written Certification as Accepted by USDA from Manufacturer

Underwriters Laboratory Inc.• Approved

Factory Mutual Approval• Passed - E - 108 Flame Spread over pitched roofing• Tested and Approved for Roofing and all other Applications

California Cool Roof Program• California Building Energy Efficiency Standards

Florida Cool Roof Rebate Program• State approval for energy rebate

Next Steps:

1. Call me directly: (520) 647 – 7672

2. Go to our website at: www.arizonasuperiorcoatings.com

3. Fill out the questionnaire and we will get back to you

Arizona Superior Coatings LLC.

Corporate Office / ApplicatorP.O. Box 385, Vail, AZ 85641

Office 520-647-7672Sales – Jim Williams, John Montano, Frank Tainatongo,

Doug Alley: Superior Performance Coatings, Inc.Phone  (520) 647 - 7672

 Email: jim@arizonasuperiorcoatings.comWebsite: www.arizonasuperiorcoatings.com