Post on 25-Sep-2020
Alarm (Visual and Audible) - Standard : 30ea - Option : Max. 90ea
The purpose of a bridge navigational watch alarm system(BNWAS) is to monitor bridgeactivity and detect operator disability which could lead to marine accidents. The system monitors the awareness of the officer of the watch(OOW) and automaticallyalerts the captain or another qualified OOW if for any reason the OOW becomes incapableof performing the OOW's duties. Additionally, the BNWAS may provide the OOW with a means of calling for immediate assistance if required.The BNWAS should be operational whenever the ship's heading or track control systemis engaged, unless inhabited by the captain.
User-friendlyDimmer controlEmergency call facilityTimer displayMotion sensor with infrared and microwave detection Auto-run input(Auto pilot)Main supply DC24V or AC220V
BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM
HBN - 117
System Feature
SYSTEM
ALARM STAGE
BRIDGE VISUAL
BRIDGE AUDIO
OFFICER CALL
CREW CALL
T I M E R
OFFICER
RUNOFF AUTO
SECOND
MINUTE
DC POWER
AC POWER
FAIL ALARM
RST
HBN - 117 Bridge Navigational Watch Alarm System
CREW
DIMMER / SET
MIN/
SECRST RST
RESET(mode)
EM'CY CALLEM'CY CALLEM'CY CALL
BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM
Captain
HBN - 117 SYSTEM DIAGRAM
Auto pilotAC
DCAMS
Motion sensorMotion sensor(BNP-720)(BNP-710)
C / Officer
2nd / Officer
Officer Deck
W/H
RESET
DIMMER
BNP-710 BNWAS
BNP-720 BNWAS
DIMMER
RESET
12min(3~12)
15sec
15sec
90sec(90~180)
3rd STAGE REMOTE AUDIBLE ALARM (CREW CALL)2nd STAGE REMOTE AUDIBLE ALARM (OFFICER CALL)1st STAGE REMOTE AUDIBLE ALARM (BRIDGE)
VISUAL INDICATOR (RESET SWITCH FLICKER)
TIME CHART
Crew Deck 1
(BNP-740) (BNP-741)
BNWAS BNWASBNWAS BNWAS
3rd / Officer
BNWAS BNWASBNWAS
Crew Deck 2
J.B
J.B
POWER SUPPLY HPS - 100B ( 24V,3A )
AC
DC
-Option-
J.B
BNWAS
SYSTEM
ALARM STAGE
BRIDGE VISUAL
BRIDGE AUDIO
OFFICER CALL
CREW CALL
T I M E R
OFFICER
RUNOFF AUTO
SECOND
MINUTE
DC POWER
AC POWER
FAIL ALARM
RST
HBN - 117 Bridge Navigational Watch Alarm System
CREW
DIMMER / SET
MIN/
SECRST RST
RESET(mode)
EM'CY CALLEM'CY CALLEM'CY CALL
BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM
HBN - 117 Detail of Devices
Model MAIN (HBN - 117)
Power Source
Dimension / Weight
ConsumptionW/H In / Output
MainEm'cy
AC100 ~ 220VDC24V
Max. 1.2AMax. 4 port (Reset, Visual, Audible Alarm)
Officer Output Max. 2 portCrew Output Max. 2 port
Motion Sensor Max. 2 portAuto Run Max. 4 port (Normal Open or Normal Close, $--HTD)
W270 X H188 X D110, 3kgNMEA Output $BNALR (IEC-61162-1, RS-422 / 4,800bps or 38,400bps)Fault Output Max. 2 port (Normal Open or Normal Close)
Desk type Wall type
W210 X H145 X D105, 2kg
DIMENSIONSOUND LEVEL
DC24V, Max 20mAPOWER SOURCE DC24V, Max 70mA
85dB/m,var.volume & tone
120W X 80H X 70D0.5kg 0.1kg
80W X 80H X 57D
85dB/m
DC24V, Max 30mA
BNP - 710F
Reset,Visual Alarm
BNP - 720F BNP - 730FMODEL
0.5kgWEIGHT80W X 120H X 70D
ALARM UNITRESET
DIMMER
BNP-710 BNWAS
BNP - 750A/R (IP65)
0.2kg / 0.15kg80W X 80H X 73D / 25
85dB/m
DC24V, Max 30mA / Max 15mA
BNP-720 BNWAS
DIMMER
RESET
BNWAS BNWAS
MODEL
DC24V, Max 30mA
80W X 80H X 58.7D0.15kg0.8kg
120W X 80H X 80D
DC24V, Max 70mAPOWER SOURCE DC24V, Max 20mA
SOUND LEVELDIMENSION 80W X 120H X 80D
WEIGHT 0.8kg
ALARM UNIT
BNP - 710 BNP - 720 BNP - 730
85dB/m, var. vol & tone 85 dB/m
BNWAS
DISCRIPTION Reset,Visual,Audible Alarm Audible Alarm Reset,Visual,Audible Alarm
Reset,Visual Alarm Reset,Visual,Audible Alarm Audible Alarm DISCRIPTION
SYSTEM
ALARM STAGE
BRIDGE VISUAL
BRIDGE AUDIO
OFFICER CALL
CREW CALL
T I M E R
OFFICER
RUNOFF AUTO
SECOND
MINUTE
DC POWER
AC POWER
FAIL ALARM
RST
HBN - 117 Bridge Navigational Watch Alarm System
CREW
DIMMER / SET
MIN/
SECRST RST
RESET(mode)
EM'CY CALLEM'CY CALLEM'CY CALL