Brain magnetic resonance imaging with contrast dependent on blood oxygenation

Post on 31-Dec-2015

27 views 2 download

Tags:

description

Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Ogawa et al. PNAS (1990) 87 :9868. Introduction. Blood oxygenation level dependent (BOLD) contrast recently discovered Two previous Ogawa et al. papers, also 1990 - PowerPoint PPT Presentation

Transcript of Brain magnetic resonance imaging with contrast dependent on blood oxygenation

Brain magnetic resonance imaging with contrast dependent on blood

oxygenationOgawa et al.

PNAS (1990) 87:9868

Introduction

• Blood oxygenation level dependent (BOLD) contrast recently discovered– Two previous Ogawa et al. papers, also 1990

• Deoxyhemoglobin decreases proton signal in gradient-echo MRI

• Its paramagnetic effect is “felt” beyond the blood vessel

• Note the difference between BOLD contrast and BOLD signal:– BOLD contrast ∝ 1 / [O2]– BOLD signal ∝ [O2]

Effect of CO2

(a) 100% O2

(b) 90% O2 / 10% CO2

CO2 increased blood flow from 0.4 to 1.7 cm/sec, reducing contrast despite decreased inspired O2.

Effect of insulin & hypoglycemia

(a) blood glucose > 20 mg /dl(b) blood glucose < 20 mg / dl(c) rescue after injecting mannose

Flow increased from 0.4-0.6 to 0.7-1.1 cm/sec. Reduced metabolism likely contributes to contrast changes.

Effect of anaesthesia

(a) 0.75% halothane(b) 3% halothane(c) 100% N2

Blood flow decreased from 0.25 (a) to 0.12 cm/sec (b).Contrast changes mostly due to reduced O2 metabolism.

Simulation of BOLD contrast

(a) Simulated contrast(b) Signal intensity profile (anoxic brain)

BOLD contrast changes within physiological ranges of venous [O2]

Conclusions

• BOLD contrast depends on supply and demand– Contrast changes in the presence and

absence of blood flow changes

• Estimated detectable change in blood oxygenation = 20%

• BOLD MRI predicted to complement PET– Deoxyhemoglobin is an intrinsic contrast

agent– Good time resolution

Questions

• What was the n?• Are these effects reliable across animals?• Why is contrast greater in 2a vs. 3c?• How does presaturation recovery work?• Is BOLD contrast really not observed in

spin-echo imaging? (See introduction)• What vessel sizes contribute most to the

BOLD effect in humans? (Ogawa et al. ’93)