Post on 07-Oct-2020
www.okayapower.com
Salient Features
In order to ful�ll ECO Friendly and Long life reliable battery packs, we have designed robust batteries with Intelligent BMS based on Lithium Ion Chemistry.
Okaya Lithium batteries are committed to deliver world class High Performance Lithium ION Battery Packs for EV & Smart Mobility.
We offer Lithium Batteries which are produced under stringent quality controls at origin of manufacturing & thereafter goes through high standard QC before reaching our customers.
Designed with high Cycle Life>2000 cycles
In House Capability of designing, robust BMS
Fast Charging
GPS Feature (Optional)
Easy replacement
More Mileage
Plug & Play
High Efficiency
Maintenance Free
Installation Flexibility
Longer Warranty
Reliable Product with PAN India Foot prints
Light Weight
Eco -Friendly
CAN Communicational(Optional)
Boost your Vehicle
with Okaya Lithium
Applications
e-Scooter e-Bike
Lithium Ferro Phospahate / NCM 2-Wheeler Battery
TM
Web: www.okayapower.com
Okaya Power Pvt. Ltd.D - 8, Udyog Nagar, Rohtak Road, New Delhi - 110 041 (India) Tel No: +91 11 49803300Email: myemail@okayapowerltd.com
OKY/MKTG/00072/VER01/020519
TM
Subject to change without prior notice
Technical Speci�cations
TM
Eco-FriendlyRecyclable(Return used Batteries)
www.okayapower.com
*T&C Apply (for details please refer warranty card)
E-Rickshaw batteries
lithium Ferro phosphate
SHTNOW M6I 3TH
*
NEW
WARRANTY
40 to 160Ah
OKAYA POWER PVT. LTD.D-8, Udyog Nagar, Rohtak Road, New Delhi - 110041
Call: 9818909090| Email: helpline@okayapowerltd.com | Missed Call Service: +91 93131 41414 | SMS: +91 74001 40440
Lithium Ferro Phosphate E-Rickshaw Batteries
Technical Specifications
TM
Long life | True capacity guaranteed | Efficient Battery Management System | High frequency operations IP65 enclosure | Extendable backup.
Salient Features
*Subject to change without prior intimation
*Batteries are customized as per application
OKY/MKTG/00001/130519
LF51040E LF51080E LF51086E LF51100E LF51160E LF60092E LF60140E
(51.2V-40AH (51.2V-80AH) (51.2V-86AH) (51.2V-100AH) (51.2V-160AH) (60V-92AH) (60V-140AH)
Chemistry LFP LFP LFP LFP LFP LFP LFP
Capacity (AH) 40 80 86 100 160 92 140
Number of cell in series 16 16 16 16 16 19 19
Number of cell in parallel 7 1 1 1 2 1 2
Total number of cells 112 16 16 16 32 19 38
Nominal voltage (V) 51.2 51.2 51.2 51.2 51.2 60 60
Pack (KWH) 2 4.1 4.4 5.1 8.2 5.5 8.4
BMS type
Operating voltage range (V) 45 ~ 58 45 ~ 58 45 ~ 58 45 ~ 58 45 ~ 58 54V ~69V 54V ~69V
Charging mode CC/CV CC/CV CC/CV CC/CV CC/CV CC/CV CC/CV
Recommended charging voltage (V) 54.7 58.4 58.4 58.4 58.4 69 69
Standard Discharging current (Amp) 30A (Max.) 50A (Max.) 50A (Max.) 100A (Max.) 100A (Max.) 60A (Max.) 100A (Max.)
Pulsed Discharge current (Amp) 60A 100A 100A 312A 300A 100A 312A
Standard Charging current (Amp) 15A 30A 30A 30A 30A 27A 27A
Cell low cut protection level (V)
Cell low cut protection recovery level (V)
Cell high cut protection level (V)
Cell high cut protection recovery level(V)
Bleeding start voltage level (V)
Bleeding current (mA)
Over temperature protection in discharging mode
Over temperature protection recovery in discharging
mode
Over temperature protection in charging mode
Over temperature protection recovery in charging
mode
Cell over voltage protection
Cell under voltage protection
Charging over current protection
Discharging over current protection
Output short circuit protection
Cell temperature protection in discharging mode
Maximum working temperature
Storage temperature
Warranty Cycle life @ 80 DOD%
Module dimension (LXWXH) (in mm) 330x320x181 490x285x230 590x350x210 500x282x242 644x300x255 545x418x190 680x325x265
Cabinet design
RS485/CAN
Battery Weight Net Weight (Kg) Approx. 25.00 34.70 50.40 50.40 67.50 56.50 82.00
ICAT Approval Status
Power connector
Protections
Temperature
Characteristics
Mechanical characteristics
General
Characteristics
Model Name
Electrical
Characteristics
PCM
70°C + 5°C
65°C + 5°C
65°C + 5°C
55°C + 5°C
2.7
3
3.75
3.6
3.5
70°C + 5°C
YES
YesNA
Optional in SBMS
YES
YES
YES
YES
YES
-0ᴼC to +60ᴼC
-0ᴼC to +60ᴼC
3 Years
IP65
Anderson Connector (SB-50/SB-75)
Nominal Voltage 12.8V 12.8V 12.8V 12.8V
Ah Capacity 40 Ah 80 Ah 100 Ah 120 Ah
Wh Capacity 512 Wh 1024 Wh 1280 Wh 1536 Wh
Recommended charging current 10A (Max) 20A (Max) 30A (Max) 35A (Max)
Recommended charging voltage 14.6V ± 0.2V 14.6V ± 0.2V 14.6V ± 0.2V 14.6V ± 0.2V
Cell Balancing Yes Yes Yes Yes
Discharge Current 15A max. 20A max. 20A max. 20A max.
Recommended Operating Range 10V-14.8V ± 0.2V 10V-14.8V ± 0.2V 10V-14.8V ± 0.2V 10V-14.8V ± 0.2V
Operating Temperature 0 To 50 degree Celsius 0 To 50 degree Celsius 0 To 50 degree Celsius 0 To 50 degree Celsius
Storage Temperature -10 to 45 degree Celsius -10 to 45 degree Celsius -10 to 45 degree Celsius -10 to 45 degree Celsius
Output Humidity 0 - 90% Rh non condensing 0 - 90% Rh non condensing 0 - 90% Rh non condensing 0 - 90% Rh non condensing
BMS Feature
Cycle Life(full charge to full discharge @ 25 deg C
Battery Warranty
Voltage Range
Configuration
Protection against Deep Discharge & Over Charge, Cell Balancing, Short Circuit & Temperature Compensation
>2500 at 100% DOD
5 Years*
10V - 14.8V ± 0.2
Series & Parallel combination
Nominal Voltage 12.8V 12.8V 12.8V 12.8V
Ah Capacity 12.5 Ah 15Ah 20 Ah 30 Ah
Wh Capacity 160 Wh 192 Wh 256 Wh 384 Wh
Recommended charging current 5A (Max) 10A (Max) 10A (Max) 10A (Max)
Recommended charging voltage 14.6V ± 0.2V 14.6V ± 0.2V 14.6V ± 0.2V 14.6V ± 0.2V
Cell Balancing Yes Yes Yes Yes
Discharge Current 5A max. 5A max. 10A max. 15A max.
Recommended Operating Range 10V-14.8V ± 0.2V 10V-14.8V ± 0.2V 10V-14.8V ± 0.2V 10V-14.8V ± 0.2V
Operating Temperature 0 To 50 degree Celsius 0 To 50 degree Celsius 0 To 50 degree Celsius 0 To 50 degree Celsius
Storage Temperature -10 to 45 degree Celsius -10 to 45 degree Celsius -10 to 45 degree Celsius -10 to 45 degree Celsius
Output Humidity 0 - 90% Rh non condensing 0 - 90% Rh non condensing 0 - 90% Rh non condensing 0 - 90% Rh non condensing
BMS Feature
Cycle Life(full charge to full discharge @ 25 deg C
Battery Warranty
Voltage Range
Configuration
Protection against Deep Discharge & Over Charge, Cell Balancing, Short Circuit & Temperature Compensation
>2500 at 100% DOD
5 Years*
10V - 14.8V ± 0.2
Series & Parallel combination
OKY/MKTG/LITHIUM_SOLAR/LFT/V01/100220
www.okayapower.com
BATTERY SWAPPING STATION
01 06
02 07
03 08
04 09
05 10
BATTERY SWAPPING STATION
BMS Docking, RealizeBattery Management
System
LED Indicatoravailable on EachSwapping Cabinet
Real Time Monitoringof Charging Current
and Voltage
Compact andcontemporary design.
IndependentlyHigh Temperature
Smoke alarm Sensoralong with each
Swapping Cabinet.
IntelligentTemperature Controland Heat Dissipation.
Intelligent
IOT product.
AutomaticFire detection
with AutomaticFire extinguisher
Power Overload,Short Circuit &
Leakage Protection.
KAYA Battery Swapping Station is one of the best
Ocharging solution available. It can deploy charging
network rapidly and effectively providing high power
charging station for 2W and 3W electric vehicles. It has
durable, robust and all weather suitable enclosure for indoor
and outdoor use. It is applicable for Highway, Public parking
station, bus station and corporate parking places.01 06
02 07
03 08
04 09
05 10
Input Parameters(AC) Output Power ( DC) Prameters
Number of Battery Slots
Total Output Power
Output Voltage Per slot
Max Current Per slot
Current accuracy
Voltage accuracy
Steady ow accuracy
Impulse current
Static Voltage Regulation
Output protection
10
1350 Watt at Each Battery Slot
40-60 V DC
Upto 20A Per Battery Slot
�30A�≤±0.3A
≤±0.1
≤±1%
≤120% Rated input current
Static +/-0.5% and Dynamic +/- 5%
Overvoltage Shutdown, Overload fold back , Over temp Shut off, Short circuit.
Input Power
Frequency
Maximum Load Capacity
THD
Power Factor
Efciency
Input Cables
Protection
230V +/- 15%
45Hz -66Hz
<17000 W
<5%
> 0.98 ( Full Load)
>95%
3 wire AC system (1 phase + N + PE)
Ip54, Circuit Breakers of Appropriate Capacity, Surge Protection , Leakage current protection , Galvanic Isolation
01 06
02 07
03 08
04 09
05 10
01 06
02 07
03 08
04 09
05 10
BATTERY SWAPPING STATION
Environment Parameters Output Power ( DC) Prameters
Onboard Modem or LAN ( Telematics for remote monitoring )
Central Managing System ( CMS) Based Monitoring
User Authentication
Communication
Yes
"Yes ( Over the Air updates Preferred- Under Development) Parameters to be MonitoredFor Each Battery Slot1) SOC2) Max & Min Temperature of the cell3) Max & Min Cell Voltage4) Energy consumed5) Time remaining for charging6) Total time taken for charging for each charging event7) LED indications for battery status a) Red ( Blinking) - Error b) Yellow ( Blinking) - Battery charging c) Green - Charging completedOverall Parameters for chargers1) Overall energy consumed by charger ( Each minute)2) Energy consumed by Chilling system ( Each Minute)3) Overall energy pumped in batteries ( Each Slot and event)4) Overall Charger Health monitoring and alerts in case of deviations”
Pre-Assigned Login Credentials, RFID (Optional)
Battery to Charger/Swapping Station- CAN 2.0
Ambient Temperature
Storage Temperature
Altitude
Humidity
Acoustic Noise
Upto 55 deg C ( linear derating from 55 deg to 75 Deg Celcius)
-20 Deg C to Upto 80 deg C
< 2000m
5% to 95% RH Non Condensing
< 65 dba
AlarmsAC input Abnormal
Communication Fail
AC Over/Under Voltage
Rectier Ok/ Fail
DC Output Over /Under Voltage
Temp Shut Off
Electric leakage protection
Auto power off (APO) upon fully charged on each slot
No-load APO, Over current protection
Auto recovery upon failure
Available
Available
Available
Available
Available
Available
Available
Available
Available
Available
Extra Features
Battery Slots Placement
Separate Flap for each of the battery slot
Locking Mechanism for each battery slot
Cooling Systems for Battery
Compartment
AC energy meter
Unique identier for the charging station
Regulation Requirements
Serviceability
Fire Safety
Warranty
10 Nos One side Access while Service Access from the Back Side Panel
without creating fatigue and inconvenience
Yes
Manual - with Self locking Feature
Forced Air Cooling
Available (accuracy +/- 0.50%)
Yes( A separate ID is provided )
AIS-138(Draft) Electric Vehicle Conductive AC charging system-ARAI ( Except
for the charger connector standard)
Charger will be repiared in less than 24 hours from the fault reporting.
Charger will be able to removed easily and cables unplugged easily.
Fire detection and alarm ( Fire suppression system preffred Optional )
Min 1 Years
:
:
:
:
:
:
:
:
:
:
:
01 06
02 07
03 08
04 09
05 10
01 06
02 07
03 08
04 09
05 10
Call: 9818909090 | Email: helpline@okayapowerltd.com Missed Call Service: +91 93131 41414 | SMS: +91 74001 40440
OKAYA POWER PVT. LTD.
D-8 Udyog Nagar, Rohtak Road, New Delhi - 110041, India
01 06
02 07
03 08
04 09
05 10
www.okayapower.com
Boost your Vehicle
with Okaya Lithium
TM
EV Battery 51.8V 38.4Ah Li- ion Battery
Key Features
Seamless Integration with our cloud platform for remote
AIS048 Certified battery
Specially Design for Swapping battery experience
NCM Cells for High Energy Density & High Cycle Life
Intelligent Charging algorithm to enhance battery life
Compatible with most existing 2-Wheelers
CAN Enabled For Vehicle Controller & Charging
Communication needs
Performance
Safety First with multi Level Protection Features
High Energy Density- Upto 230 W/h/I
Peak Power tolerance of 3Kw for 10 Sec
In built Intelligent Battery Management for Heat rain, Sun - (Water
Proof IP65 Cabinet)
Unibody Aluminium Extrusion designed for Superior Thermal
Performance
Minimal Self -Discharge at 3% per month
Web: www.okayapower.com
Okaya Power Pvt. Ltd.D - 8, Udyog Nagar, Rohtak Road, New Delhi - 110 041 (India) Tel No: +91 11 49803300Email: myemail@okayapowerltd.com
OKY/MKTG/VER01/181219
TM
Battery pack
Chemistry
Rated Energy
Specific Energy
Volumetric Energy
Estimated Life (at 85% DOD 35°C)
Nominal Voltage
Charge Current (AMP)
Nominal Charging Time Discharge Current
Peak Discharge Current (AMP)
Discharge Current Rate
Efficiency
Connector Type
Operating Temperature
Cabinet IP
Humidity (Non-Condensing)
Dimension(WxDxH)
Weight in Kg
Cooling
EMI/EMC
Safety
Communication Interface
Transportation
38 AH
NMC
Optional Blue Tooth for mobile Application
Dashboard Showing Real Time battery Data.
20 A (Nominal)
0-95%
0°C to 45°C Charge & -20°C to 60°C Discharge
>97%
51.8VDC
35 A (Nominal)
1,100 CYCLES
13.9 KG
Passive
IP65
CAN Bus For Vehicle Controller & Swapping
Charging Station.
IEC EN 61000-4-2 to 6
UN38.3
65A (for 10 Sec)
Anderson Connector SBX-75
Optional 4G/2G Telematics Card for getting Real
Time Battery Performance Data & Remote
Programming Capability.
230.1 WH/I
2 hours
148.2 wh/kg
200X180X250(MM)
2.0 KWH (0.2C,100% DOD AT 25 °C)
AIS048, Ul1642
Protections
General
Characteristics
Electrical
Characteristics
Mechanical
Characteristics
Temperature
Characteristics
Subject to change without prior notice.
Technical Specifications