Post on 07-Jul-2018
8/18/2019 Bare & Twisted
1/37
8/18/2019 Bare & Twisted
2/37
VIEW OF BARE CONDUCTOR
AAC ALL ALUMINUM CONDUCTOR
AAAC ALL ALUMINUM ALLOY CONDUCTOR
T - AAAC THERMAL RESISTANCE ALL ALUMINUM ALLOY CONDUCTOR
ACSR ALUMINUM CONDUCTOR STEEL REINFORCED
T - ACSR THERMAL RESISTANCE ALUMINUM CONDUCTORSTEEL REINFORCED
ACSR / AS ALUMINUM CONDUCTOR - ALUMINUM CLAD STEELREINFORCED
T - ACSR / AS THERMAL RESISTANCE ALUMINUM CONDUCTOR -ALUMINUM CLAD STEEL REINFORCED
STACIR SUPER THERMAL RESISTANCE - INVAR REINFORCED
STACIR / AW SUPER THERMAL RESISTANCE - ALUMINUM CLADINVAR REINFORCED
ACCR ALUMINUM CONDUCTOR COMPOSITE REINFORCED
ACCC / TW ALUMINUM CONDUCTOR COMPOSITE CORE TRAPEZOIDAL CONCENTRIC-LAY-STRANDED
AAAC - S ALL ALUMINUM ALLOY CONDUCTOR, XLPE INSULATED
CONVERSION TABLE
NF/NFA2X COPPER/ALUMINUM CONDUCTOR, XLPE INSULATED
NFA2X - T ALUMINUM CONDUCTOR, XLPE INSULATED + NEUTRALNEUTRAL MESSENGER
DUPLEX ALUMINUM CONDUCTOR, XLPE INSULATED + NEUTRALNEUTRAL MESSENGER
TRIPLEX ALUMINUM CONDUCTOR, XLPE INSULATED + NEUTRALNEUTRAL MESSENGER
QUADRUPLEX ALUMINUM CONDUCTOR, XLPE INSULATED + NEUTRALNEUTRAL MESSENGER
Table Of Contents
2
3
6
8
9
15
16
22
23
24
25
26
27
28
29
30
34
35
36
8/18/2019 Bare & Twisted
3/37
AAC All Aluminum ConductorAAAC All Aluminum Alloy Conductor
T-AAAC Thermal Resistance All AluminumAlloy Conductor
ACSR 1. All Aluminum Conductor
2. Galvanized Steel Wire
T-ACSR 1. Thermal Resistance AluminumAlloy Conductor
2. Galvanized Steel Wire
STACIR 1. Super Thermal Resistance AluminumAlloy Conductor
2. Galvanized Invar
ACCR 1. Aluminum-Zirconium
2. Galvanized Steel Wire
ACSR / AS 1. All Aluminum Conductor
2. Aluminum - Clad Steel Wire
T-ACSR / AS 1. Thermal Resistance AluminumAlloy Conductor
2. Aluminum - Clad Steel Wire
STACIR / AW 1. Super Thermal Resistance AluminumAlloy Conductor
2. Aluminum - Clad Invar
ACCC / TW 1. Aluminum Conductor
2. High Strength Carbon Fiber
View Of Bare Conductor
1
2
1
2
1
2
8/18/2019 Bare & Twisted
4/37
AAC All Aluminum Conductor
Specification : SPLN 41-6
03
Application : Used for overhead power transmission purpose, medium tension. Overhead system and distribution
network.
Construction
Conductor : Circular stranded All Aluminum Conductor [AAC]
Packing : Drum
pcs
7
7
7
7
19
7
19
19
7
19
19
37
37
1919
61
61
61
61
91
91
91
mm
1.75
2.25
2.50
3.00
1.75
3.25
2.25
2.50
4.25
2.75
3.25
2.25
2.50
3.754.00
2.25
2.50
3.00
3.25
3.00
3.25
3.75
mm
5.25
6.75
7.50
9.00
8.75
9.75
11.25
12.50
12.75
13.75
16.25
15.75
17.50
18.7520.00
20.25
22.50
27.00
29.25
33.00
35.75
41.25
Ω /km
1.7000
1.0290
0.8332
0.5786
0.6295
0.4930
0.3808
0.3084
0.2883
0.2549
0.1825
0.1960
0.1587
0.13710.1205
0.1191
0.0965
0.0670
0.0571
0.0450
0.0384
0.0288
A
150
145
165
205
195
230
270
305
320
345
430
410
470
510555
560
640
805
890
1,030
1,135
1,345
kg
310
490
590
810
835
935
1,040
1,560
1,540
1,890
2,530
2,575
3,110
3,2903,700
4,020
4,850
6,675
7,700
9,960
11,480
14,925
m
10,000
10,000
10,000
10,000
10,000
10,000
5,000
5,000
5,000
5,000
5,000
5,000
5,000
3,0003,000
3,000
3,000
2,000
2,000
1,500
1,000
1,000
Cross Section
Area
Nominal
mm²
16
25
35
50
50
55
70
95
100
120
150
150
185
20024
240
300
400
500
630
800
1.000
Actual
mm²
16.84
27.83
34.36
49.48
45.70
58.07
75.55
93.27
99.30
112.85
157.62
147.11
181.62
209.85238.76
242.54
299.43
431.18
506.04
643.24
754.91
1,005.06
Weight
Approx
kg/km
46
76
94
135
126
159
208
257
272
310
434
406
501
577657
670
827
1,191
1,398
1,782
2,091
2,784
No. of
Wires
Diameter of
Wires
Overall
Diameter
Approx
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
5/3704
Cross Section
Area
No. of
Wires
pcs
7
7
7
7
7
7
7
7
19
7
7
19
19
19
19
19
19
37
19
37
19
19
37
37
3737
61
37
Diameter
of Wires
mm
1.55
1.96
2.47
2.78
3.12
3.50
3.93
4.42
2.91
4.80
4.96
3.01
3.19
3.38
3.45
3.68
3.91
2.88
4.02
2.95
4.12
4.35
3.11
3.23
3.333.37
2.72
3.49
Overall
Diameter
Approx.
mm
4.70
5.90
7.40
8.30
9.40
10.40
11.80
13.30
14.60
14.60
14.90
15.10
16.00
16.90
17.20
18.40
19.60
20.18
20.10
20.66
20.60
21.70
21.80
22.60
23.3023.60
24.50
24.50
Weight
Approx.
kg/km
37
58
93
117
147
186
234
259
349
349
373
373
419
470
489
556
628
667
666
699
698
777
777
838
888908
978
978
DC
Resistance
At 20ºC
Ω /km
2.1710
1.3638
0.8568
0.6804
0.5391
0.4281
0.3392
0.2688
0.2277
0.2275
0.2131
0.2132
0.1895
0.1690
0.1626
0.1431
0.1264
0.1194
0.1194
0.1139
0.1138
0.1023
0.1023
0.0949
0.08950.0875
0.0813
0.0813
Current
Rating
A
90
120
160
185
215
250
290
335
370
370
385
390
420
450
460
500
540
560
560
575
575
615
615
645
670680
715
710
Rated
Ultimated
Strength
kg
254
404
610
726
890
1,121
1,373
1,732
2,101
2,047
2,185
2,180
2,452
2,750
2,858
3,249
3,567
3,922
3,778
4,109
3,963
4,409
4,444
4,790
5,0825,199
5,854
5,592
Standard
Length
m
10,000
10,000
10,000
10,000
10,000
5,000
5,000
5,000
5,000
5,000
5,000
5,000
5,000
5,000
5,000
3,000
3,000
3,000
3,000
3,000
3,000
3,000
3,000
3,000
2,0002,000
2,000
2,000
AWG or
MCM
6
4
2
1
1/0
2/0
3/0
4/0
250.000
250.000
266.800
266.800
300.000
336.400
350.000
397.500
450.000
477.000
477.000
500.000
500.000
556.500
556.500
600.000
636.000650.000
700.000
700.000
mm2
13.29
21.16
33.61
42.38
53.48
67.41
85.03
107.22
126.70
126.72
135.16
135.16
152.00
170.45
177.35
201.41
228.00
241.54
241.67
253.06
253.35
282.00
282.00
304.00
322.25329.35
354.71
354.71
Code
Name
Peachbell
Rose
Iris
Pansy
Poppy
Aster
Phlox
Oxlip
Valerian
Sneezewort
Daisy
Laurel
Peony
Tulip
Daffodil
Canna
Goldentuft
Syringa
Cosmos
Hyacinth
Zinnia
Dahlia
Mistletoe
Meadowsweet
OrchidHeuchera
Flag
Verbena
Application : Used for overhead power transmission purpose, medium tension. Overhead system and distribution
network.
Construction
Conductor : Circular stranded All Aluminum Conductor [AAC]
Packing : Drum
Specification : ASTM B231
AAC All Aluminum Conductor
8/18/2019 Bare & Twisted
6/3705
Application : Used for overhead power transmission purpose, medium tension. Overhead system and distribution
network.
Construction
Conductor : Circular stranded All Aluminum Conductor [AAC]
Packing : Drum
AAC All Aluminum Conductor
Specification : ASTM B 231
Cross Section
Area
pcs
61
37
61
3761
37
61
37
61
37
61
37
61
37
61
61
61
61
61
61
61
61
91
91
91
91
127
127
mm
2.75
3.53
2.82
3.622.90
3.72
3.09
3.96
3.18
4.08
3.25
4.18
3.31
4.24
3.43
3.55
3.67
3.78
3.89
4.00
4.10
4.30
3.76
3.99
4.21
4.42
3.90
4.22
mm
24.80
24.70
25.30
25.3026.10
26.10
27.80
27.70
28.60
28.60
29.30
29.20
29.80
29.70
30.90
32.00
33.00
34.00
35.00
36.00
37.00
38.70
41.40
43.90
46.30
48.60
50.70
54.80
Weight
Approx.
kg/km
1,000
1,000
1,048
1,0481,111
1,111
1,257
1,257
1,333
1,333
1,397
1,397
1,444
1,444
1,555
1,665
1,777
1,888
1,999
2,110
2,222
2,445
2,793
3,174
3,527
3,880
4,232
4,985
Ω /km
0.0795
0.0795
0.0758
0.07580.0715
0.0715
0.0632
0.0632
0.0596
0.0596
0.0569
0.0569
0.0550
0.0551
0.0511
0.0477
0.0447
0.0421
0.0397
0.0376
0.0358
0.0325
0.0288
0.0255
0.0230
0.0209
0.0192
0.0164
A
725
725
745
745770
770
835
835
865
865
890
890
910
910
950
990
1,030
1,070
1,110
1,145
1,180
1,250
1,345
1,440
1,530
1,610
1,690
1,830
kg
5,822
5,721
6,104
5,9966,474
6,356
7,117
6,982
7,547
7,401
7,898
7,757
8,172
8,012
8,802
9,423
10,054
10,363
10,980
11,593
12,192
13,429
15,329
17,250
19,167
21,089
22,758
26,540
m
2,000
2,000
2,000
2,0002,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
AWG or
MCM
715.500
715.500
750.000
750.000795.000
795.000
900.000
900.000
954.000
954.000
1,000.000
1,000.000
1,033.500
1,033.500
1,113.000
1,192.500
1,272.000
1,351.500
1,431.000
1,510.500
1,590.000
1,750.000
2,000.000
2,250.000
2,500.000
2,750.000
3,000.000
3,500.000
mm2
362.58
362.58
380.00
380.00402.84
402.84
456.06
456.06
483.42
483.42
506.71
506.71
523.68
523.68
563.93
604.26
644.51
684.84
725.10
765.35
805.68
886.71
1,013.00
1,140.00
1,267.00
1,393.00
1,520.00
1,773.00
Code
Name
Nasturtium
Violet
Cattail
PetuniaLilac
Arbutus
Snapdragon
Cockscomb
Goldenrod
Magnolia
Camelia
Hawkweed
Larkspur
Bluebell
Marigold
Hawthorn
Narcissus
Columbine
Carnation
Gladiolus
Coreopsis
Jessamine
Cowslip
Sagebrush
Lupine
Bitterroot
Trillium
Bluebonnet
No. of
Wires
Diameter
of Wires
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
7/3706
Application : Used for overhead power transmission purpose, medium tension. Overhead system and distribution
network.
Construction
Conductor : Circular stranded All Aluminum Alloy Conductor [AAAC]
Packing : Drum
AAAC All Aluminum Alloy Conductor
Cross Section Area
Nominal
mm2
16
25
35
50
50
55
70
95
100
120
150
150
185
240240
300
400
500
630
800
1.000
Actual
mm2
16.84
27.83
34.36
49.48
45.70
58.07
75.55
93.27
99.30
112.85
157.62
147.11
181.62
238.76242.54
299.43
431.18
506.04
643.24
754.91
1,005.06
pcs
7
7
7
7
19
7
19
19
7
19
19
37
37
1961
61
61
61
91
91
91
mm
1.75
2.25
2.50
3.00
1.75
3.25
2.25
2.50
4.25
2.75
3.25
2.25
2.50
4.002.25
2.50
3.00
3.25
3.00
3.25
3.75
mm
5.25
6.75
7.50
9.00
8.75
9.75
11.25
12.50
12.75
13.75
16.25
15.75
17.50
20.0020.25
22.50
27.00
29.25
33.00
35.75
41.25
Weight
Approx.
kg/km
46
76
94
135
126
160
208
256
272
310
434
406
501
670657
827
1,191
1,398
1,782
2,091
2,784
Ω /km
1,955
1,183
0,958
0,665
0,724
0,567
0,438
0,355
0,332
0,293
0,210
0,225
0,183
0,1370,139
0,111
0,077
0,066
0,052
0,044
0,033
A
100
135
155
195
185
215
255
290
300
325
405
385
440
525525
605
760
835
965
1,075
1,265
kg
480
790
980
1,410
1,300
1,655
2,150
2,660
2,830
3,220
4,490
4,190
5,175
6,8056,910
8,530
12,290
14,420
18,330
21,515
28,640
m
10,000
10,000
10,000
10,000
10,000
10,000
5,000
5,000
5,000
5,000
5,000
5,000
5,000
3,0003,000
3,000
2,000
2,000
1,500
1,000
1,000
Specification : SPLN 41-8
No. of
Wires
Diameter
of Wires
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
8/3707
Application : Used for overhead power transmission purpose, medium tension. Overhead system and distribution
network.
Construction
Conductor : Circular stranded All Aluminum Aloy Conductor [AAAC]
Packing : Drum
AAAC All Aluminum Aloy Conductor
Specification : ASTM B 399
Cross Section
Area
pcs
7
7
7
77
7
7
19
19
19
19
19
19
37
37
37
37
37
37
37
37
61
61
61
mm
1.55
1.96
2.47
3.123.50
3.93
4.42
2.91
3.19
3.45
3.69
3.91
4.12
3.10
3.23
3.37
3.49
3.62
3.73
3.96
4.18
3.64
3.98
4.30
mm
4.66
5.88
7.42
9.3610.50
11.80
13.25
14.57
15.97
17.25
18.43
19.55
20.60
21.67
22.63
23.58
24.45
25.32
26.14
27.73
29.23
32.72
35.85
38.73
Weight
Approx.
kg/km
37,
59
93
147185
235
296
348
419
490
560
629
699
769
839
909
979
1,049
1,119
1,258
1,399
1,737
2,086
2,434
Ω /km
2.52240
1.58460
0.99550
0.626400.49740
0.39410
0.31230
0.26450
0.22020
0.18900
0.16530
0.14690
0.13230
0.12020
0.11030
0.10160
0.09448
0.08811
0.08268
0.07342
0.06610
0.05292
0.04407
0.03776
A
85
115
150
200235
270
315
350
390
430
470
505
540
575
605
640
670
700
725
785
835
960
1,075
1,180
kg
429
683
1,087
1,7282,077
2,621
3,307
3,962
4,760
5,295
6,054
6,810
7,564
8,529
9,299
9,633
10,361
11,109
11,839
13,333
14,808
18,295
21,965
25.636
m
10,000
10,000
10,000
10,0005,000
5,000
5,000
5,000
5,000
5,000
3,000
3,000
3,000
3,000
3,000
2,000
2,000
2,000
2,000
2,000
2,000
1,500
1,000
1,000
AWG or
MCM
6
4
2
1/02/0
3/0
4/0
250.000
300.000
350.000
400.000
450.000
500.000
550.000
600.000
650.000
700.000
750.000
800.000
900.000
1,000.000
1,250.000
1,500.000
1,750.000
mm2
13.28
21.14
33.65
53.4867.35
85.00
107.26
126.63
152.14
177.28
202.70
228.03
253.30
278.59
303.74
329.64
354.56
380.18
405.13
456.26
506.77
633.04
760.05
887.08
No. of
Wires
Diameter
of Wires
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
9/3708
Application : Used for overhead power transmission purpose, medium tension. Overhead system and distribution
network.
Construction
Conductor : Circular stranded thermal resistance All Aluminum Alloy Conductor (T-AAAC)
Packing : Drum
AAAC All Aluminum Alloy Conductor
Cross Section Area
Nominal
mm2
150
200
240
300
400
510
660
850
980
1,030
1,260
1,600
2,020
2,500
Actual
mm2
152.81
204.29
238.76
297.57
397.83
512.61
655.88
845.12
978.44
1,032.04
1,260.75
1,595.93
2,019.85
2,493.64
pcs
19
19
19
37
37
37
61
61
91
91
91
127
127
127
mm
3.20
3.70
4.00
3.20
3.70
4.20
3.70
4.20
3.70
3.80
4.20
4.00
4.50
5.00
mm
16.00
18.50
20.00
22.40
25.90
29.40
33.30
37.80
40.70
41.80
46.20
52.00
58.50
65.00
Weight
Approx.
kg/km
419
560
655
820
1,097
1,413
1,812
2,334
2,716
2,864
3,449
4,439
5,618
6,936
Ω /km
0.1910
0.1430
0.1220
0.0985
0.0737
0.0571
0.0448
0.0347
0.0302
0.0286
0.0234
0.0186
0.0147
0.0118
A
650
790
897
1,030
1,258
1,491
1,753
2,073
2,272
2,353
2,672
3,225
3,705
4,180
kg
2,270
3,030
3,490
4,430
5,890
7,460
9,720
12,300
14,500
15,320
18,350
23,320
29,490
36,350
m
5,000
5,000
3,000
3,000
2,000
2,000
1,500
1,000
1,000
1,000
500
500
500
300
Specification : JEC 197
No. of
Wires
Diameter
of Wires
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
10/37
ACSR Aluminum Conductor Steel Reinforced
Specification : SPLN 41-7
09
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of galvanized steel and the outer layer or layers of aluminum.
Packing : Drum
Cross Section Area No. / Diameter of Wires
Nominal
Al / St
mm²
16 / 2.5
25 / 4
35 / 6
44 / 32
50 / 8
50 / 30
70 / 12
95 / 15
95 / 55
105 / 75
120 / 20
120 / 70
125 / 30
150 / 25 170 / 40
185 / 30
210 / 35
210 / 50
230 / 30
Steel
mm²
2.54
3.98
5.73
31.67
8.04
29.85
11.40
15.33
56.30
75.55
19.85
71.25
29.85
24.25 40.08
29.85
34.09
49.48
29.85
Aluminum
mm²
15.27
23.86
34.35
43.98
48.25
51.17
69.89
94.39
96.51
105.67
121.57
122.15
127.92
148.86171.77
183.78
209.10
212.06
230.91
pcs / mm
6 / 1.80
6 / 2.25
6 / 2.70
14 / 2.00
6 / 3.20
12 / 2.33
26 / 1.85
26 / 2.15
12 / 3.20
14 / 3.10
26 / 2.44
12 / 3.60
30 / 2.33
26 / 2.70 30 / 2.70
26 / 3.00
26 / 3.20
30 / 3.00
24 / 3.50
pcs / mm
1 / 1.80
1 / 2.25
1 / 2.70
7 / 2.40
1 / 3.20
7 / 2.33
7 / 1.44
7 / 1.67
7 / 3.20
19 / 2.25
7 / 1.90
7 / 3.60
7 / 2.33
7 / 2.107 / 2.70
7 / 2.33
7 / 2.49
7 / 3.00
7 / 2.33
mm
5.40
6.80
8.10
11.20
9.60
11.70
11.70
13.60
16.00
17.50
15.50
18.00
16.30
17.1018.90
19.00
20.30
21.00
21.00
Weight
Approx
kg/km
62
97
140
372
196
378
284
383
712
908
494
915
593
604 796
745
848
982
873
Ω /km
1.87900
1.20300
0.835300.65730
0.59460
0.56440
0.41300
0.30580
0.29920
0.27360
0.23740
0.23640
0.22590
0.19390
0.16820
0.15710
0.13800
0.13630
0.12490
A
100
135
165
205
205
225
260
315
335
355
370
385
385
420 465
480
520
530
555
kg
606
938
1.290
4.348
1.743
4.466
2.732
3.566
8.091
11.058
4.655
10.197
5.873
5.633 7.826
6.750
7.637
9.575
7.454
m
10,000
10,000
10,000
5,000
10,000
5,000
5,000
5,000
3,000
3,000
3,000
3,000
3,000
3,000 3,000
3,000
3,000
3,000
3,000
ActualAluminum Steel
Overall
Diameter
Approx
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
11/3710
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of galvanized steel and the outer layer or layers of aluminum.
Packing : Drum
Specification : SPLN 41-7
ACSR Aluminum Conductor Steel Reinforced
Cross Section Area No. / Diameter of Wires
Nominal
Al / St
mm²
240 / 40
265 / 35
300 / 50
305 / 40
340 / 30
380 / 50
385 / 35
435 / 55
450 / 40
490 / 65
495 / 35
510 / 45
550 / 70
560 / 50570 / 40
650 / 45
680 / 85
1,045/ 45
Steel
mm²
39.49
34.09
49.48
39.49
29.85
49.48
34.09
56.30
39.49
63.55
34.09
45.28
71.25
49.4839.49
45.28
85.95
45.38
Aluminum
mm²
243.05
263.66
304.26
304.62
339.29
381.70
386.04
434.29
448.71
490.28
494.36
510.54
549.65
561.70571.16
653.49
678.58
1,045.58
pcs / mm
26 / 3.45
24 / 3.74
26 / 3.86
54 / 2.68
48 / 3.00
54 / 3.00
48 / 3.20
54 / 3.20
48 / 3.45
54 / 3.40
45 / 3.74
48 / 3.68
54 / 3.60
48 / 3.86 45 / 4.02
45 / 4.30
54 / 4.00
72 / 4.30
pcs / mm
7 / 2.68
7 / 2.49
7 / 3.00
7 / 2.68
7 / 2.33
7 / 3.00
7 / 2.49
7 / 3.20
7 / 2.68
7 / 3.40
7 / 2.49
7 / 2.87
7 / 3.60
7 / 3.00 7 / 2.68
7 / 2.87
19 / 2.40
7 / 2.87
mm
21.90
22.40
24.50
24.10
25.00
27.00
26.70
28.80
28.70
30.60
29.90
30.70
32.40
32.2032.20
34.40
36.00
43.00
Weight
Approx
kg/km
985
998
1,233
1,155
1,174
1,448
1,344
1,647
1,553
1,856
1,636
1,761
2,085
1,9431,888
2,163
2,566
3,220
Ω /km
0.11830
0.10940
0.09497
0.09490
0.08525
0.07573
0.07493
0.06656
0.06446
0.05896
0.05846
0.05655
0.05259
0.051490.05060
0.04426
0.04260
0.02770
A
575
600
755
750
800
865
870
940
955
1,015
1,015
1,035
1,090
1,1001,110
1,205
1,245
1,600
kg
8,640
8,468
10,910
10,135
9,473
12,552
10,686
13,914
12,313
15,611
12,420
13,682
17,396
15,18813,897
15,856
21,044
22,201
m
2,000
2,000
2,000
2,000
2,000
2,000
2,000
1,500
1,500
1,500
1,500
1,500
1,000
1,5001,500
1,000
1,000
500
ActualAluminum Steel
Overall
Diameter
Approx
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
12/37
ACSR Aluminum Conductor Steel Reinforced
Specification : ASTM B232-69
11
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of galvanized steel and the outer layer or layers of aluminum.
Packing : Drum
Code
Name
Grouse
Petrel
Minorca
LeghornGuinea
Dotterel
Dorking
Brahma
Cochin
Turkey
Swan
Swanate
Sparrow
Sparate
Robin
Raven
Quail
Pigeon
Penguin
Waxwing
Partridge
Ostrich
Merlin
Linnet
Oriole
Aluminum Cross
Section Area
No. / Diameter
of Wires
AWG or
MCM
80.000
101.800
110.800
134.600159.000
176.900
190.800
203.200
211.300
6
4
4
2
2
1
1/0
2/0
3/0
4/0
266.800
266.800
300.000
336.400
336.400
336.400
mm2
40.54
51.56
56.16
68.2080.58
89.64
96.69
103.00
107.10
13.28
21.14
21.14
33.64
33.65
42.40
53.55
67.40
85.00
107.20
135.10
135.20
152.00
170.40
170.30
170.50
pcs/mm
8 / 2.54
12/ 2.34
12/ 2.44
12/ 2.6912/ 2.92
12/ 3.08
12/ 3.20
16/ 2.86
12/ 3.37
6 / 1.68
6 / 2.12
7 / 1.96
6 / 2.67
7 / 2.47
6 / 3.00
6 / 3.37
6 / 3.78
6 / 4.25
6 / 4.77
18/ 3.09
26/ 2.57
26/ 2.73
18/ 3.47
26/ 2.89
30/ 2.69
pcs/mm
1 / 4.24
7 / 2.34
7 / 2.44
7 / 2.697 / 2.92
7 / 3.08
7 / 3.20
19 / 2.48
7 / 3.37
1 / 1.68
1 / 2.12
1 / 2.61
1 / 2.67
1 / 3.30
1 / 3.00
1 / 3.37
1 / 3.78
1 / 4.25
1 / 4.77
1 / 3.09
7 / 2.00
7 / 2.12
1 / 3.47
7 / 2.25
7 / 2.69
Ω /km
0.71120
0.56190
0.51590
0.424800.35950
0.32320
0.29960
0.28130
0.27050
2.16030
1.35710
1.35710
0.85280
0.85260
0.67650
0.53570
0.42570
0.33750
0.26760
0.21340
0.21430
0.19060
0.16920
0.16920
0.17010
A
185
225
235
265295
315
335
355
355
90
125
125
165
165
190
220
255
295
340
390
395
425
450
455
460
kg
2,333
4,702
5,121
6,1857,268
7,837
8,453
12,920
9,363
537
845
1,077
1,296
1,647
1,612
1,974
2,375
2,995
3,778
3,088
5,133
5,765
3,896
6,378
7,893
m
5,000
5,000
5,000
5,0005,000
3,000
3,000
2,000
3,000
10,000
10,000
10,000
10,000
10,000
10,000
5,000
5,000
5,000
5,000
5,000
5,000
3,000
5,000
3,000
3,000
Weight
Approx.
kg/km
222
378
412
500591
657
709
1,006
785
54
85
100
137
159
172
217
273
344
434
432
548
615
544
689
785
mm
9.32
11.70
12.21
13.4514.62
15.42
16.02
18.14
16.86
5.04
6.36
6.53
8.01
8.24
9.00
10.11
11.34
12.75
14.31
15.45
16.28
17.28
17.35
18.31
18.83
Aluminum Steel
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
13/3712
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of galvanized steel and the outer layer or layers of aluminum.
Packing : Drum
Specification : ASTM B232-69
ACSR Aluminum Conductor Steel Reinforced
Code
Name
Chikadee
Brant
Ibis
Lark
Pelican
Flicker
Hawk
Hen
Osprey
Parakeet
Dove
Eagle
Peacock
SquabWood Duck
Teal
Kingbird
Rook
Grosbeak
Scoter
mm2
201.40
201.40
201.20
201.40
241.70
241.70
241.50
241.70
281.80
282.00
282.00
281.90
306.70
306.50306.60
306.60
322.30
322.30
322.30
322.20
pcs/mm
18/ 3.77
24/ 3.27
26/ 3.14
30/ 2.92
18/ 4.14
24/ 3.58
26/ 3.44
30/ 3.20
18/ 4.47
24/ 3.87
26/ 3.72
30 / 3.46
24/ 4.03
26 / 3.8730/ 3.61
30/ 3.61
18/ 4.78
24/ 4.14
26/ 3.97
30/ 3.70
pcs/mm
1 / 3.77
7 / 2.18
7 / 2.44
7 / 2.92
1 / 4.14
7 / 2.39
7 / 2.68
7 / 3.20
1 / 4.47
7 / 2.58
7 / 2.89
7 / 3.46
7 / 2.69
7 / 3.017 / 3.61
19 / 2.16
1 / 4.78
7 / 2.76
7 / 3.09
7 / 3.70
Weight
Approx.
kg/km
643
763
814
927
772
916
977
1,113
900
1,068
1,141
1,298
1,162
1,2401,411
1,400
1,029
1,220
1,304
1,483
mm
18.87
19.61
19.88
20.47
20.68
21.50
21.78
22.42
22.33
23.21
23.54
24.21
24.21
24.5425.25
25.25
23.88
24.82
25.15
25.90
kg
4,432
6,592
7,347
9,229
5,319
7,823
8,820
10,740
6,202
8,989
10,301
12,526
9,781
11,04313,132
13,620
7,093
10,273
11,408
13,801
m
5,000
3,000
3,000
3,000
3,000
3,000
2,000
2,000
3,000
2,000
2,000
2,000
2,000
2,0002,000
2,000
2,000
2,000
2,000
2,000
Ω /km
0.14310
0.14390
0.14400
0.14420
0.11930
0.11990
0.12000
0.12010
0.10230
0.10270
0.10270
0.10300
0.09446
0.094520.09472
0.09472
0.08945
0.08989
0.08989
0.09014
A
500
505
510
510
565
570
570
575
620
625
630
630
660
660665
665
675
680
685
690
Aluminum Cross
Section Area
No. / Diameter
of Wires
AWG or
MCM
397.500
397.500
397.500
397.500
477.000
477.000
477.000
477.000
556.500
556.500
556.500
556.500
605.000
605.000605.000
605.000
636.000
636.000
636.000
636.000
Aluminum Steel
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
14/3713
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of galvanized steel and the outer layer or layers of aluminum.
Packing : Drum
ACSR Aluminum Conductor Steel Reinforced
Specification : ASTM B232-69
Aluminum
Cross Section Area
No./Diameter of
Wires
Code
Name
Egret
Swift
Flamingo
Gannet
Stilt
Starling
Redwing
Tern
Coot
Condor
Cuckoo
Drake
Mallard
RuddyCanary
Catbird
Rail
Cardinal
Tanager
Ortolan
mm2
322.20
322.30
337.90
337.80
362.80
362.60
362.40
402.80
402.70
402.60
402.90
402.90
402.90
456.00456.00
483.40
483.30
483.40
523.50
523.30
AWG or
MCM
636.000
636.000
666.600
666.600
715.500
715.500
715.500
795.000
795.000
795.000
795.000
795.000
795.000
900.000900.000
954.000
954.000
954.000
1,033.50
1,033.50
Weight
Approx.
kg/km
1,472
959
1,279
1,366
1,374
1,467
1,654
1,335
1,199
1,524
1,525
1,630
1,840
1,5111,727
1,439
1,602
1,830
1,558
1,734
mm
25.90
23.63
25.40
25.76
26.32
26.70
27.45
27.01
26.42
27.73
27.74
28.13
28.95
28.7429.52
28.95
29.60
30.38
30.12
30.78
pcs/mm
19 / 2.22
1 / 3.38
7 / 2.82
7 / 3.16
7 / 2.92
7 / 3.28
19 / 2.35
7 / 2.25
1 / 3.77
7 / 3.08
7 / 3.08
7 / 3.45
19 / 2.48
7 / 2.407 / 3.28
1 / 4.14
7 / 2.47
7 / 3.38
1 / 4.30
7 / 2.57
pcs/mm
30 / 3.70
36 / 3.38
24 / 4.23
26 / 4.07
24 / 4.39
26 / 4.21
30 / 3.92
45 / 3.38
36 / 3.77
54 / 3.08
24 / 4.62
26 / 4.44
30 / 4.14
45 / 3.5954 / 3.28
36 / 4.14
45 / 3.70
54 / 3.38
36 / 4.30
45 / 3.85
Ω /km
0.09014
0.08945
0.08574
0.08577
0.07986
0.07990
0.08014
0.07193
0.07159
0.07196
0.07191
0.07191
0.07208
0.063530.06353
0.05964
0.05995
0.05993
0.05507
0.05536
A
690
675
700
705
735
735
740
775
775
780
785
785
790
840845
865
870
875
910
915
kg
14,326
6,169
10,770
11,955
11,563
12,837
15,686
9,920
7,445
12,682
12,636
14,262
17,458
11,14214,364
8,937
11,809
15,227
9,678
12,541
m
2,000
2,000
2,000
2,000
2,000
2,000
1,500
2,000
2,000
1,500
1,500
1,500
1,500
1,5001,500
2,000
1,500
1,500
1,500
1,500
Aluminum Steel
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
15/3714
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of galvanized steel and the outer layer or layers of aluminum.
Packing : Drum
ACSR Aluminum Conductor Steel Reinforced
Specification : ASTM B232-69
Aluminum
Cross Section Area
No./Diameter of
Wires
Code
Name
Curlew
Bluejay
FinchBunting
Grackle
Skylark
Bittern
Pheasant
Dipper
Martin
Bobolink
Plover
Nuthatch
Parrot
Lapwing
Falcon
Chukar
Bluebird
Kiwi
Thrasher
mm2
523.40
564.10
564.10604.30
604.10
644.70
644.10
644.40
684.50
684.70
724.60
725.20
765.20
764.60
805.80
805.50
902.20
1,092.30
1,097.80
1,170.90
AWG or
MCM
1,033.500
1,33.000
1,133.0001,92.500
1,192.500
1,272.000
1,272.000
1,272.000
1,351.500
1,351.500
1,431.000
1,431.000
1,510.500
1,510.500
1,590.000
1,590.000
1,780.000
2,156.000
2,167.000
2,312.000
Weight
Approx.
kg/km
1,982
1,869
2,1322,005
2,282
1,920
2,140
2,433
2,275
2,585
2,410
2,738
2,540
2,890
2,678
3,042
3,095
3,747
3,419
3,767
mm
31.62
31.96
32.8333.08
34.97
33.43
34.17
35.08
35.21
36.17
36.25
37.22
37.22
38.21
38.20
39.23
40.68
44.75
44.06
45.77
pcs/mm
7 / 3.51
7 / 2.66
19 / 2.197 / 2.76
19 / 2.27
1 / 4.78
7 / 2.85
19 / 2.34
7 / 2.93
19 / 2.41
7 / 3.02
19 / 2.48
7 / 3.10
19 / 2.55
7 / 3.18
19 / 2.62
19 / 2.22
19 / 2.44
7 / 2.94
19 / 2.07
pcs/mm
54/ 3.51
45/ 4.00
54/ 3.6545/ 4.14
54/ 3.77
36/ 4.78
45/ 4.27
54/ 3.90
45/ 4.40
54/ 4.02
45/ 4.53
54/ 4.14
45/ 4.65
54/ 4.25
45/ 4.78
54/ 4.36
84/ 3.70
84/ 4.07
72 / 4.41
76/ 4.43
Ω /km
0.05535
0.05136
0.051610.04793
0.04800
0.04472
0.04500
0.04500
0.04230
0.04230
0.04000
0.03990
0.03790
0.03790
0.03600
0.03600
003230
0.02670
0.02640
0.02490
A
920
960
9601,000
1,005
1,035
1,040
1,045
1,080
1,085
1,115
1,125
1,155
1,160
1,190
1,200
1,270
1,420
1,420
1,475
kg
16,488
13,522
17,77614,175
18,000
11,621
15,118
19,198
16,059
20,389
17,009
21,602
17,952
22,772
18,904
24,005
22,473
26,692
22,220
25,015
m
1,500
1,500
1,5001,000
1,000
1,500
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
Aluminum Steel
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
16/3715
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of galvanized steel and the outer layer or layers of thermal resistance alloy
aluminum.
Packing : Drum
T-ACSR Thermal Resistance-Aluminum Conductor Steel Reinforced
Specification : JEC 197
Cross Section Area No. / Diameter of Wires
Nominal
TAL
mm²
58
80
80
95
100
120
120
160
200
240
330
410
520
610680
680
810
1.160
1.520
Steel
mm²
9.62
13.85
21.24
15.90
26.42
32.17
29.08
37.17
46.24
56.30
52.83
67.35
67.35
79.3987.96
46.24
56.30
96.98
126.67
TAL
mm²
57.73
83.13
79.64
95.43
99.08
120.64
124.64
159.28
198.16
241.27
326.73
413.51
519.54
612.42678.58
684.24
814.30
1,163.77
1,520.03
pcs / mm
6 / 3.50
6 / 4.20
15/ 2.60
6 / 4.50
15/ 2.90
15/ 3.20
30 / 2.30
30 / 2.60
30 / 2.90
30 / 3.20
26 / 4.00
26 / 4.50
54 / 3.50
54 / 3.8054 / 4.00
45 / 4.40
45 / 4.80
84 / 4.20
84 / 4.80
pcs / mm
1 / 3.50
1 / 4.20
4 / 2.60
1 / 4.50
4 / 2.90
4 / 3.20
7 / 2.30
7 / 2.60
7 / 2.90
7 / 3.20
7 / 3.10
7 / 3.50
7 / 3.50
7 / 3.807 / 4.00
7 / 2.90
7 / 3.20
7 / 4.20
7 / 4.80
mm
10.50
12.60
13.00
13.50
14.50
16.00
16.10
18.20
20.30
22.40
25.30
28.50
31.50
34.2036.00
35.10
38.40
46.20
52.80
Weight
Approx
kg/km
234
336
386
386
480
585
574
734
912
1,111
1,320
1,674
1,969
2,3212,572
2,260
2,700
3,997
5,221
Ω /km
0.5050
0.3500
0.3680
0.3050
0.2960
0.2430
0.2370
0.1850
0.1490
0.1220
0.0901
0.0712
0.0567
0.04810.0434
0.0431
0.0362
0.0254
0.0195
A
375
480
470
525
545
620
630
745
860
980
1,190
1,390
1,610
1,7951,920
1,910
2,145
2,700
3,185
kg
1,980
2,770
3,810
3,180
4,740
5,550
5,460
6,980
8,680
10,170
10,940
13,900
15,590
18,38019,790
15,590
18,460
27,870
36,410
m
5,000
5,000
5,000
5,000
5,000
5,000
5,000
3,000
3,000
2,000
2,000
1,500
1,500
1,0001,000
1,000
1,000
500
500
Actual TAL Steel
Overall
Diameter
Approx
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
17/3716
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of aluminum clad steel and the outer layer or layers of aluminum.
Packing : Drum
Specification : DIN 48204
ACSR /AS Aluminum Conductor - Aluminum
Clad Steel Reinforced
Cross Section Area No. / Diameter of Wires
Nominal
Al / St
mm²
16 / 2.5
25 / 4
35 / 6
44 / 32
50 / 8
50 / 30
70 / 12
95 / 15
95 / 55
105 / 75
120 / 20
120 / 70
125 / 30
150 / 25
170 / 40
185 / 30
210 / 35
210 / 50
230 / 30
Steel
mm²
2.54
3.98
5.73
31.67
8.04
29.85
11.40
15.33
56.30
75.55
19.85
71.25
29.85
24.25
40.08
29.85
34.09
49.48
29.85
Aluminum
mm²
15.27
23.86
34.35
43.98
48.25
51.17
69.89
103.38
96.51
105.67
121.57
122.15
127.92
148.86
171.77
183.78
209.10
212.06
230.91
pcs / mm
6 / 1.80
6 / 2.25
6 / 2.70
14 / 2.00
6 / 3.20
12 / 2.33
26 / 1.85
26 / 2.25
12 / 3.20
14 / 3.10
26 / 2.44
12 / 3.60
30 / 2.33
26 / 2.70
30 / 2.70
26 / 3.00
26 / 3.20
30 / 3.00
24 / 3.50
pcs / mm
1 / 1.80
1 / 2.25
1 / 2.70
7 / 2.40
1 / 3.20
7 / 2.33
7 / 1.44
7 / 1.67
7 / 3.20
19 / 2.25
7 / 1.90
7 / 3.60
7 / 2.33
7 / 2.10
7 / 2.70
7 / 2.33
7 / 2.49
7 / 3.00
7 / 2.33
mm
5.40
6.75
8.10
11.20
9.60
11.65
11.72
14.01
16.00
17.75
15.46
18.00
16.31
17.10
18.90
18.99
20.27
21.00
20.99
Weight
Approx
kg/km
59
93
133
333
187
341
270
362
640
797
470
810
554
575
744
709
805
918
835
Ω /km
1.7790
1.1390
0.7906
0.5282
0.5629
0.4712
0.3915
0.2899
0.2498
0.2203
0.2250
0.1974
0.2093
0.1838
0.1559
0.1489
0.1308
0.1263
0.1197
A
105
135
170
230
210
245
270
325
365
400
380
425
400
430
480
495
535
550
565
kg
607
938
1,321
4,797
1,825
4,664
2,743
3,660
8,686
11,254
4,674
10,148
6,045
5,658
8,048
6,902
7,804
9,853
7,600
m
10,000
10,000
10,000
5,000
10,000
5,000
5,000
5,000
3,000
3,000
5,000
3,000
5,000
5,000
3,000
3,000
3,000
3,000
3,000
ActualAluminum Steel
Overall
Diameter
Approx
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
18/37
Specification : DIN 48204
17
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of aluminum clad steel and the outer layer or layers of aluminum.Packing : Drum
ACSR /AS Aluminum Conductor - Aluminum Clad Steel Reinforced
Cross Section AreaNo./ Diameter
of Wires
A1/St
mm2
240 / 40
265 / 35
300 / 50305 / 40
340 / 30
380 / 50
385 / 35
435 / 55
450 / 40
490 / 65
495 / 35
510 / 45
550 / 70
560 / 50
570 / 40
650 / 45
680 / 85
1.045 / 45
Aluminum
mm2
243,05
263,66
304,26304,62
339,29
381,70
386,04
434,29
448,71
490,28
494,36
510,54
549,65
561,70
571,16
653,49
678,58
1.045,58
Steel
mm2
39,49
34,09
49,4839,49
29,85
49,48
34,09
56,30
39,49
63,55
34,09
45,28
71,25
49,48
39,49
45,28
85,95
45,28
pcs/mm
7 / 2,68
7 / 2,49
7 / 3,00
7 / 2,68
7 / 2,33
7 / 3,00
7 / 2,49
7 / 3,20
7 / 2,68
7 / 3,40
7 / 2,49
7 / 2,87
7 / 3,60
7 / 3,00
7 / 2,68
7 / 2,87
19 / 2,40
7 / 2,87
pcs/mm
26 / 3,45
24 / 3,74
26 / 3,86
54 / 2,68
48 / 3,00
54 / 3,00
48 / 3,20
54 / 3,20
48 / 3,45
54 / 3,40
45 / 3,74
48 / 3,68
54 / 3,60
48 / 3,86
45 / 4,02
45 / 4,30
54 / 4,00
72 / 4,30
mm
21,84
22,43
24,4024,12
24,99
27,00
26,67
28,80
28,74
30,60
29,91
30,69
32,40
32,16
32,16
34,41
36,00
43,01
Weight
Approx.
kg/km
938
958
1.1701.108
1.140
1.388
1.298
1.578
1.508
1.780
1.598
1.710
1.995
1.880
1.823
2.110
2.454
3.207
Ω /km
0,1126
0,1048
0,0899
0,0909
0,0827
0,0725
0,0727
0,0638
0,0625
0,0565
0,0571
0,0549
0,0504
0,05000,0494
0,0432
0,0409
0,0274
A
590
615
680
670
710
725
770
840
845
905
898
915
970
970
975
1.060
1.100
1.390
kg
9.012
8.624
11.163
10.311
9.577
12.768
10.796
14.394
12.442
15.704
12.427
14.098
17.202
15.352
14.256
16.265
21.830
22.615
m
3.000
3.000
2.0002.000
2.000
2.000
2.000
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.000
1.000
500
ActualNominalAluminum Steel
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
19/3718
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of aluminum clad steel and the outer layer or layers of aluminum.
Packing : Drum
Specification : ASTM B 549
ACSR /AS Aluminum Conductor - Aluminum Clad Steel Reinforced
Aluminum
Cross Section Area
No./Diameter of
Wires
Code
Name
Grouse
Petrel
Minorca
Leghorn
Guinea
Dotterel
Dorking
Brahma
Cochin
Turkey
Swan
Swanate
Sparrow
Sparate
Robbin
Raven
Quail
Pigeon
Penguin
Waxwing
Partridge
Ostrich
Merlin
Linnet
Oriole
mm2
40,54
51,60
56,20
68,20
80,60
89,60
96,70
103,00
107,10
13,29
21,10
21,10
33,61
33,70
42,39
53,50
67,40
85,00
107,20
135,10
135,20
152,00
170,40
170,30
170,50
MCM
80,000
101,800
110,800
134,600
159,000
176,900
190,800
203,200
211,300
6
4
4
2
21
1/0
2/0
3/0
4/0
266,800
266,800
300,000
336,400
336,400
336,400
Weight
Approx.
kg/km
205
343
373
453
535
595
642
896
711
52
82
94
130
149
164
206
260
327
413
423
521
614
533
689
738
mm
9,32
11,70
12,21
13,45
14,62
15,42
16,02
18,14
16,86
5,04
6,35
6,54
8,02
8,25
9,00
10,11
11,35
12,74
14,31
15,45
16,30
17,28
17,35
18,29
18,83
pcs/mm
1 / 4,24
7 / 2,34
7 / 2,44
7 / 2,69
7 / 2,92
7 / 3,08
7 / 3,20
19 / 2,48
7 / 3,37
1 / 1,68
1 / 2,12
1 / 2,61
1 / 2,67
1 / 3,301 / 3,00
1 / 3,37
1 / 3,78
1 / 4,25
1 / 4,77
1 / 3,09
7 / 2,00
7 / 2,12
1 / 3,47
7 / 2,25
7 / 2,69
pcs/mm
8 / 2,54
12/ 2,34
12/ 2,44
12/ 2,69
12/ 2,92
12/ 3,08
12/ 3,20
16/ 2,86
12/ 3,37
6 / 1,68
6 / 2,12
7 / 1,96
6 / 2,67
7 / 2,476 / 3,00
6 / 3,37
6 / 3,78
6 / 4,25
6 / 4,77
18/ 3,09
26/ 2,57
26/ 2,73
18/ 3,47
26/ 2,89
30/ 2,69
Ω /km
0,63580
0,46850
0,43010
0,35440
0,29990
0,26980
0,25000
0,21590
0,22570
2,04280
1,28740
1,25130
0,80830
0,78440
0,64030
0,50770
0,40300
0,31950
0,25330
0,20940
0,20300
0,18060
0,16600
0,16120
0,15780
A
200
245
260
290
325
345
365
405
390
95
125
130
170
175195
225
260
305
350
395
405
435
455
470
480
kg
2.191
4.456
4.852
5.859
6.885
7.616
8.215
12.275
8.891
515
808
1.037
1.255
1.5911.561
1.914
2.301
2.854
3.480
3.063
4.909
5.513
3.833
6.096
7.605
m
5.000
5.000
5.000
5.000
5.000
5.000
3.000
3.000
3.000
10.000
10.000
10.000
10.000
10.000
10.000
10.000
10.000
5.000
5.000
5.000
5.000
5.000
5.000
3.000
3.000
AWG or Aluminum Steel
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
20/37
ACSR /AS Aluminum Conductor - Aluminum Clad Steel Reinforced
Specification : ASTM B549
19
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of aluminum clad steel and the outer layer or layers of aluminum.
Packing : Drum
Code
Name
Chikadee
Brant
Ibis
Lark
Pelican
Flicker
Hawk
Hen
Osprey
Parakeet
Dove
Eagle
Peacock
SquabWood Duck
Teal
Kingbird
Rook
Grosbeak
Scoter
Aluminum Cross
Section Area
No. / Diameter
of Wires
MCM
397,500
397,500
397,500
397,500
477,000
477,000
477,000
477,000
556,500
556,500
556,500
556,500
605,000
605,000605,000
605,000
636,000
636,000
636,000
636,000
mm2
201,40
201,40
201,20
201,40
241,70
241,70
241,50
241,70
281,80
282,00
282,00
281,90
306,70
306,30306,60
306,60
322,30
322,30
322,30
322,20
pcs/mm
18/ 3,77
24/ 3,27
26/ 3,14
30/ 2,92
18/ 4,14
24/ 3,58
26/ 3,44
30/ 3,20
18/ 4,47
24/ 3,87
26/ 3,72
30/ 3,46
24/ 4,03
26/ 3,8730/ 3,61
30/ 3,61
18/ 4,78
24/ 4,14
26/ 3,97
30/ 3,70
pcs/mm
1 / 3,77
7 / 2,18
7 / 2,44
7 / 2,92
1 / 4,14
7 / 2,39
7 / 2,68
7 / 3,20
1 / 4,47
7 / 2,58
7 / 2,89
7 / 3,46
7 / 2,69
7 / 3,017 / 3,61
19 / 2,16
1 / 4,78
7 / 2,76
7 / 3,09
7 / 3,70
Ω /km
0,14050
0,13780
0,13640
0,13360
0,11710
0,11480
0,11370
0,11130
0,10040
0,09840
0,09730
0,09540
0,09050
0,089600,08770
0,08790
0,08780
0,08610
0,08520
0,08350
A
505
515
520
530
570
580
585
595
625
640
645
655
675
680690
690
680
695
700
715
kg
4.359
6.327
7.109
8.889
5.185
7.596
8.535
10.552
5.993
8.724
9.968
12.088
9.493
10.67812.901
12.931
6.795
9.970
11.233
13.308
m
3.000
3.000
3.000
3.000
3.000
3.000
3.000
2.000
3.000
2.000
2.000
2.000
2.000
2.0002.000
2.000
2.000
2.000
2.000
2.000
Weight
Approx.
kg/km
630
732
775
871
756
878
930
1.045
881
1.024
1.086
1.219
1.114
1.1801.326
1.316
1.008
1.170
1.241
1.393
mm
18,87
19,61
19,88
20,47
20,70
21,49
21,78
22,42
22,33
23,21
23,54
24,21
24,21
24,5325,25
25,25
23,88
24,81
25,16
25,89
AWG or Aluminum Steel
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
21/3720
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of aluminum clad steel and the outer layer or layers of aluminum
Packing : Drum
Specification : ASTM B549
ACSR /AS Aluminum Conductor - Aluminum Clad Steel Reinforced
Code
Name
Egret
Swift
Flamingo
Gannet
Stilt
Starling
Redwing
Cuckoo
Drake
Coot
Tern
Condor
Mallard
RuddyCanary
Catbird
Rail
Cardinal
Tanager
Ortolan
Aluminum Cross
Section Area
No. / Diameter
of Wires
MCM
636,000
636,000
666,600
666,600
715,500
715,500
715,500
795,000
795,000
795,000
795,000
795,000
795,000
900,000900,000
954,000
954,000
954,000
1.033,500
1.033,500
mm2
322,20
322,30
337,90
337,80
362,80
362,60
362,40
402,90
402,90
402,70
402,80
402,60
402,90
456,00456,00
483,40
483,30
483,40
523,50
523,30
pcs/mm
30/ 3,70
36/ 3,38
24/ 4,23
26/ 4,07
24/ 4,39
26/ 4,21
30/ 3,92
24/ 4,62
26/ 4,44
36/ 3,77
45/ 3,38
54/ 3,08
30/ 4,14
45/ 3,5954/ 3,28
36/ 4,14
45/ 3,70
54/ 3,38
36/ 4,30
45/ 3,85
pcs/mm
19 / 2,22
1 / 3,38
7 / 2,82
7 / 3,16
7 / 2,92
7 / 3,28
19 / 2,35
7 / 3,08
7 / 3,45
1 / 3,77
7 / 2,25
7 / 3,08
19 / 2,48
7 / 2,407 / 3,28
1 / 4,14
7 / 2,47
7 / 3,38
1 / 4,30
7 / 2,57
Ω /km
0,08360
0,08860
0,08210
0,08130
0,07650
0,07570
0,07437
0,06887
0,06813
0,07092
0,07027
0,06892
0,06689
0,062070,06085
0,05908
0,05857
0,05740
0,05456
0,05409
A
715
675
715
725
750
755
770
800
805
780
785
800
820
850865
870
880
895
915
925
kg
13.601
6.221
10.453
11.772
11.222
12.444
15.107
12.462
13.825
7.372
9.637
12.509
16.813
10.91413.971
8.803
11.567
14.810
9.533
12.279
m
2.000
3.000
2.000
2.000
2.000
2.000
1.500
2.000
1.500
2.000
2.000
2.000
1.500
1.5001.500
2.000
1.500
1.500
1.500
1.500
Weight
Approx.
kg/km
1.384
949
1.227
1.301
1.317
1.396
1.555
1.463
1.552
1.185
1.301
1.462
1.730
1.4731.656
1.423
1.562
1.755
1.541
1.691
mm
25,89
23,63
25,40
25,75
26,32
26,69
27,45
27,74
28,13
26,42
27,01
27,73
28,95
28,7429,51
28,95
29,59
30,38
30,12
30,78
AWG or Aluminum Steel
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
22/3721
Specification : ASTM B 549
Code
Name
Curlew
Bluejay
FinchBunting
Grackle
Skylark
Bittern
Pheasant
Dipper
Martin
Bobolink
Plover
Nuthatch
Parrot
Lapwing
Falcon
Chuckar
Bluebird
Kiwi
Thrasher
Aluminum Cross
Section Area
No. / Diameter
of Wires
MCM
1,033.500
1,113.000
1,113.0001,192.500
1,192.500
1,272.000
1,272.000
1,272.000
1,351.500
1,351.500
1,431.000
1,431.000
1,510.500
1,510.500
1,590.000
1,590.000
1,780.000
2,156.000
2,167.000
2,312.000
mm2
523.40
564.10
564.10604.30
604.10
644.70
644.10
644.40
684.50
684.70
724.60
725.20
765.20
764.60
805.80
805.50
902.20
1,092.30
1,097.80
1,170.90
pcs/mm
54/ 3.51
45/ 4.00
54/ 3.6545/ 4.14
54/ 3.77
36/ 4.78
45/ 4.27
54/ 3.90
45/ 4.40
54/ 4.02
45/ 4.53
54/ 4.14
45/ 4.65
54/ 4.25
45/ 4.78
54/ 4.36
84/ 3.70
84/ 4.07
72/ 4.41
76/ 4.43
pcs/mm
7 / 3.51
7 / 2.66
19 / 2.197 / 2.76
19 / 2.27
1 / 4.78
7 / 2.85
19 / 2.34
7 / 2.93
19 / 2.41
7 / 3.02
19 / 2.48
7 / 3.10
19 / 2.55
7 / 3.18
19 / 2.62
19 / 2.22
19 / 2.44
7 / 2.94
19 / 2.07
Ω /km
0.05301
0.05018
0.049470.04684
0.04598
0.04430
0.04395
0.04310
0.04135
0.04057
0.03906
0.03830
0.03699
0.03633
0.03513
0.03448
0.03140
0.02593
0.02601
0.02441
A
940
970
9801,010
1,025
1,040
1,050
1,070
1,090
1,110
1,130
1,145
1,165
1,185
1,205
1,220
1,290
1,440
1,430
1,485
kg
15,804
13,240
17,07114,175
18,000
11,621
15,118
19,198
16,059
20,389
17,009
21,602
17,952
22,772
18,904
24,005
22,473
26,692
22,220
25,015
m
1,500
1,500
1,0001,000
1,000
1,500
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
Weight
Approx.
kg/km
1,901
1,823
2,0461,952
2,183
1,897
2,081
2,328
2,211
2,473
2,341
2,620
2,472
2,762
2,603
2,911
3,001
3,633
3,358
3,686
mm
31.62
31.96
32.8333.08
33.97
33.43
34.16
35.08
35.21
36.16
36.23
37.22
37.22
38.21
38.20
39.23
40.68
44.75
44.06
45.77
ACSR /AS Aluminum Conductor - Aluminum Clad Steel Reinforced
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of aluminum clad steel and the outer layer or layers of aluminum.
Packing : Drum
AWG or Aluminum Steel
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
23/3722
Specification : JEC 197
T-ACSR/AS Thermal Resistance - AluminumConductor Clad Steel Reinforced
Application : Used for overhead transmission lines.
Construction
Conductor : The center wire or wires of aluminum clad steel and the outer layer or layers of thermal resistance
aluminum alloy..
Packing : Drum
Cross Section Area No./ Diameterof Wires
TAL
mm2
58
80
80
95
100
120
120
160
200
240
330
410
520
610
680
680
810
1,160
1,520
TAL
mm2
57.73
83.13
79.64
95.43
99.08
120.64
124.64
159.28
198.16
241.27
326.73
413.51
519.54
612.42
678.58
684.24
814.30
1,163.77
1,520.03
Steel
mm2
9.62
13.85
21.24
15.90
26.42
32.17
29.08
37.17
46.24
56.30
52.83
67.35
67.35
79.39
87.96
46.24
56.30
96.98
126.67
pcs/mm
1 / 3.50
1 / 4.20
4 / 2.60
1 / 4.50
4 / 2.90
4 / 3.20
7 / 2.30
7 / 2.60
7 / 2.90
7 / 3.20
7 / 3.10
7 / 3.50
7 / 3.50
7 / 3.80
7 / 4.00
7 / 2.90
7 / 3.20
7 / 4.20
7 / 4.80
pcs/mm
6 / 3.50
6 / 4.20
15/ 2.60
6 / 4.50
15/ 2.90
15/ 3.20
30 / 2.30
30 / 2.60
30 / 2.90
30 / 3.20
26 / 4.00
26 / 4.50
54/ 3.50
54/ 3.80
54/ 4.00
45/ 4.40
45/ 4.80
84/ 4.20
84/ 4.80
mm
10.50
12.60
13.00
13.50
14.50
16.00
16.10
18.20
20.30
22.40
25.30
28.50
31.50
34.20
36.00
35.10
38.40
46.20
52.80
Weight
Approx.
kg/km
219
315
359
362
447
535
537
686
853
1,024
1,239
1,570
1,866
2,199
2,436
2,201
2,613
3,848
5,026
Ω /km
0.4736
0.3289
0.3380
0.2870
0.2717
0.2196
0.2190
0.1718
0.1381
0.1118
0.0847
0.0669
0.0535
0.0458
0.0415
0.0421
0.0352
0.0246
0.0188
A
390
495
495
540
570
655
655
770
890
1,025
1,225
1,435
1,655
1,840
1,960
1,930
2,170
2,740
3,230
kg
1,980
2,830
3,810
3,180
1,740
5,550
5,460
6,980
8,680
10,170
10,940
13,900
15,590
18,380
20,180
15,590
18,460
28,310
36,410
m
5,000
5,000
5,000
5,000
5,000
5,000
5,000
3,000
3,000
2,000
2,000
1,500
1,500
1,000
1,000
1,000
1,000
500
500
ActualNominal TAL Steel
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
24/3723
Application : Used for overhead transmission lines.
Construction
Conductor : The center wires of galvanized invar and the outer layers of super thermal resistance
aluminum alloy.
Packing : Drum
STACIR Super Thermal Resistance - Invar Reinforced
Specification : KEPCO
Cross Section Area No./ Diameterof Wires
mm2
120
160240
330
410
480
610
810
ST-AI
mm2
124.64
159.28241.27
326.73
413.51
483.84
612.42
814.30
Invar
mm2
29.08
37.1756.30
52.83
67.35
33.54
79.39
56.30
pcs/mm
7/ 2.30
7/ 2.607/ 3.20
7/ 3.10
7/ 3.50
7 /2.47
7/ 3.80
7/ 3.20
pcs/mm
30/ 2.30
30/ 2.6030/ 3.20
26/ 4.00
26/ 4.50
45/ 3.70
54/ 3.80
45/ 4.80
mm
16.10
18.2022.40
25.30
28.50
29.61
34.20
38.40
Weight
Approx.
kg/km
580
7401,122
1,330
1,687
1,611
2,336
2,712
Ω /km
0.23700
0.185000.12200
0.09040
0.07140
0.06070
0.04810
0.36300
A
746
8831,172
1,424
1,674
1,800
2,137
2,559
kg
4,890
6,1409,170
10,000
12,720
10,500
16,960
17,440
m
5,000
3,0003,000
2,000
2,000
1,500
1,500
1,500
ActualNominal ST - AI Invar
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
25/3724
Application : Used for overhead transmission lines.
Construction
Conductor : The center wires of aluminum clad invar and the outer layers of super thermal resistance
aluminum alloy.
Packing : Drum
STACIR/AW Super Thermal Resistance - AluminumClad Invar Reinforced
Specification : KEPCO
Cross Section Area No./ Diameterof Wires
mm2
160
240
280
330
410
480 (Rail)
480 (Cardinal)
mm2
159.28
241.27
281.07
326.73
413.51
483.84
484.53
AI - CladInvar
mm2
37.17
56.3040.08
52.83
67.35
33.54
62.81
pcs/mm
7 / 2.60
7 / 3.20
7 / 2.70
7 / 3.10
7 / 3.50
7 / 2.47
7 / 3.38
pcs/mm
30 / 2.60
30 / 3.20
26 / 3.71
26 / 4.00
26 / 4.50
45 / 3.70
54 / 3.38
mm
18.20
22.40
21.60
25.30
28.50
29.61
30.40
Weight
Approx.
kg/km
707
1,070
1,064
1,285
1,625
1,580
1,796
Ω /km
0.1745
0.1159
0.1015
0.0869
0.0686
0.0600
0.0591
A
909
1,203
1,280
1,452
1,708
1,812
1,846
kg
6,140
9,170
8,980
10,000
12,720
10,500
13,280
m
3,000
3,000
2,000
2,000
2,000
1,500
1,500
Actual
NominalST - AI
AluminumAI - Vlad
Invar
Overall
Diameter
Approx.
DC
Resistance
At 20ºC
Current
Rating
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
26/3725
Application : Used for overhead transmission lines.
Construction
Conductor : The center wires of galvanized steel and the outer layers of aluminum-zirconium.
Packing : Drum
ACCR Aluminum Conductor Composite Reinforced
Specification : ASTM B779
Linnet 336
Ibis 397
Hawk 477Dove 557
Grosbeak 636
Drake 795
Cardinal 954
Curlew 1033
Finch 1113
Pheasant 1272
Martin 1351
Falcon 1590
Cross Section
Area
No. / Diameter
of Wires
mm2
172
205
238291
323
418
490
525
566
642
676
808
mm2
200
239
277338
375
484
552
591
638
723
761
910
pcs/mm
26/2.90
26/3.20
26/3.4026/3.80
26/4.00
26/4.50
54/3.40
54/3.50
54/3.70
54/3.90
54/4.00
54/4.40
pcs/mm
7 /2.30
7 /2.50
7 /2.707 /2.90
7 /3.10
19/2.10
19/2.00
19/2.10
19/2.20
19/2.30
19/2.40
19/2.60
Ω /km
0.1596
0.1338
0.11530.0945
0.0851
0.0658
0.0572
0.0534
0.0495
0.0437
0.0415
0.0347
A
942
1,058
1,167
1,331
1,426
1,691
1,855
1,941
2,042
2,219
2,298
2,588
A
1,010
1,135
1,253
1,430
1,533
1,820
1,997
2,090
2,199
2,392
2,477
2,792
kgf
6,305
7,484
8,70910,478
11,612
14,606
15,059
16,148
17,418
19,505
20,548
24,313
m
5,000
3,000
3,0003,000
2,000
2,000
2,000
2,000
2,000
1,500
1,500
1,500
Weight
Approx.
kg/km
573
684
793967
1,073
1,384
1,576
1,687
1,820
2,063
2,172
2,596
mm
18.4
20.1
21.623.9
25.2
28.6
30.6
31.7
32.9
35.0
35.9
39.3
Current Rating
at
210ºC 240ºC
*
Code
NameAluminum Total Aluminum Steel
Overall
Diameter
DC
Resistance
At 20ºC
Rated
Ultimated
Strength
Standard
Length
8/18/2019 Bare & Twisted
27/3726
Application : Used for overhead power distribution and transmission lines.
Construction
Conductor : The central is a proprietary high strength carbon fiber composite core and around which are
aluminum wires.
Packing : Drum
ACCC / TW Aluminum Conductor Composite Core Trapezoidal Concentric-Lay-Stranded
Specification : ASTM B 857 ASTM B 609, Manufacturer Specification
Helsinki
Copenhagen
LisbonAmsterdam
Brussels
Stockholm
Warsaw
Dublin
Hamburg
Cross Section
Area
Nominal
No. of
Aluminum Wires
mm2
160
220
310360
415
460
510
520
550
pcs
16
16
16 20
20
20
22
22
22
Ω /km
0.1861
0.1279
0.08960.0769
0.0673
0.0612
0.0556
0.0541
0.0517
A
775
986
1,2501,386
1,515
1,616
1,723
1,756
1,806
kg
64.0
65.6
93.2110.6
122.1
141.1
142.3
166.4
143.2
m
2.000
2.000
2.0002.000
2.000
2.000
2.000
2.000
2.000
Weight
Approx.
kg/km
480
670
9571,113
1,275
1,406
1,539
1,559
1,646
Diameter
of
Conductor
mm
15.65
18.29
21.7823.55
25.14
26.40
27.72
28.15
28.62
Current
Carrying
Capacity
(A)
Rated
Ultimated
Strength
Standard
Length
DC
Resistance
At 20ºC
Code
Name
* Condition of Current Carrying Capacity Calculation
- Conductivity of Aluminium : 63%
- Ambient Temperature : 35ºC
- Wind Velocity : 0.6 m/s - Solar Radiation : 0.1 W/cm2
- Radiation Factor : 0.9
- Continous Operating Temperature : @ 175ºC
8/18/2019 Bare & Twisted
28/37
Specification : SPLN 41-10
27
Application : Used for overhead transmission and distribution.
Construction
Conductor : All Aluminum Alloy Conductor (AAAC), circular stranded according to SPLN 41-8
Insulation : Cross-linked Polyethylene (XLPE), complied with SPLN 41-9.
Packing : Drum
Note : (rm) Circular stranded
AAAC - S All Aluminum Alloy Conductor, XLPE Insulated
CONSTRUCTION
Cross - Section of Conductor mm2
Number of cores pcs
Diameter of Conductor (approx.) mm
Thickness of Insulation (nom.) mm
Overall Cable Diameter (approx.) mm
35 rm
7
7,5
3,0
13,5
50 rm
19
8,8
3,0
14,8
70 rm
19
11,3
3,0
17,3
95 rm
19
12,5
3,0
18,5
120 rm
19
13,8
3,0
19,8
150 rm
37
15,8
3,0
21,8
185 rm
37
17,5
3,0
26,3
240 rm
61
20.3
3.0
26.3
DELIVERY
Standard Delivery Length m
Drum Type (D)
Cable Weight (approx.) kg/km
1.000
09C
195
1.000
09C
268
1.000
11A
345
1.000
11A
407
1.000
15A
475
1.000
15A
593
1.000
15A
700
1.000
14B
893
MECHANICAL
Minimum Bending Radius mm
Breaking Strength kgf
243
980
266
1,300
311
2,150
333
2,660
356
3,220
392
4,190
423
5,175
473
6,910
ELECTRICAL
3,5/50,868
1.000
3,5/5
0,641
900
3,5/50,253
800
3,5/50,443
900
3,5/50,206
800
3,5/50,164
800
3,5/50,125
700
3,5/50,320
800
AC Voltage Test
Max. Conductor DC Resistance at 200C
Min. Insulation Resistance at 200C
kV/min
Ω /km
MΩ /km
CURRENT RATINGS
In Air167
150
200
180
275
246
315
282
356
319
423
378
484
432
586
523
A
A
at 300C
at 400C
SHORT CIRCUIT CURRENT
15,18
6,794,80
10,63
4,753,36
21,25
9,506,72
45,54
20,3614,40
28,84
12,909,12
56,16
25,1217,76
72,86
32,5823,04
36,43
16,2911,52
Max. Permissible
Short Circuit
Current For
0.1 Second
0.5 Second
1.0 Second
kA
kAkA
8/18/2019 Bare & Twisted
29/3728
CONVERSION TABLE
sq.mm sq.mm sq.mm
0,5 0,50 AWG20 [0.517]
0,75 0,75 19 [0.653]
18 [0.823]
17 [1.04]
1,25 16 [1.31]
1,5 15 [1.65]
2,0
2,5 14 [2.08]
13 [2.62]
3,5 12 [3.31]
4 11 [4.17]
10 [5.26]
5,5
6 9 [6.63]
8,0
10 8 [8.37]
7 [10.55]
14 6 [13.30]
25 5 [16.77]
22 4 [21.15]
35 3 [26.67]
50 38 2 [33.63]
1 [42.41]
60 1/0 [53.48]
70 2/0 [67.43]
95 3/0 [85.03]
100 4/0 [107.20]
120 MCM
150 150 250 [126.64]
185 300 [152.00]
200
240
250 400 [202.71]
300 500 [353.35]
350 600 [304.00]
400 400 700 [354.71]
500 500 800 [405.35]
600 1000 [506.71]
630
AWG or MCM
IEC JIS AMERICAN STANDARD
8/18/2019 Bare & Twisted
30/37
NF/NFA 2X Copper or Aluminum Conductor, XLPE0.6 / 1 kV Insulated
Specification : SPLN 42-10
29
Application : Used for secondary distribution and street lighting overhead low voltage power cable.
Construction
Conductor : annealed copper conductor, circular stranded according to SPLN 41-1
or aluminum conductor, circular stranded according to SPLN 41-1
Insulation : Cross-linked Polyethylene (XLPE), complied with SPLN 41-9.
Identification of core : rip core
Packing : Drum
Note : (rm) Circular stranded
CONSTRUCTION
No. of Core 2 4
Cross-Section of Conductor mm2
Diameter of Conductor (approx.) mm
Thickness of Insulation (nom.) mm
Overall Cable Diameter (approx.) mm
2 x 6 rm
3.2
1.2
11.1
4 x 6 rm
3.2
1.2
13.4
2 x 10 rm
4.1
1.2
12.9
2 x 16 rm
5.1
1.2
15.1
4 x 10 rm
4.1
1.2
15.5
4 x 16 rm
5.1
1.2
18.2
4 x 25 rm
6.4
1.4
22.2
4 x 35 rm
7.6
1.6
25.9
DELIVERY
Standard Delivery Length m
Drum Type (D)
Cable Weight Copper (approx.) kg/km
Aluminum (approx.) kg/km
1,000
09C
144
67
1,000
09C
224
97
1,000
09C
345
141
1,000
09C
288
135
1,000
09C
448
195
1,000
11A
690
283
1,000
15A
1,063
429
1,000
14B
1,481
594
MECHANICAL
Breaking Strength
Minimum Bending Radius
394
-
200
656
322
232
1051
515
272
788
-
241
1312
644
279
2102
1030
328
3284
1610
400
-
2250
466
kgf
kgf
mm
Copper
Aluminum
CURRENT RATINGS
In Air at 350C54
-
73
54
97
72
54
-
73
54
97
72
133
102
-
125
A
A
Copper
Aluminum
ELECTRICAL
Copper
Aluminum
Copper
Aluminum
3.5/5
3.08
4.61
1,500
1,500
3.5/5
1.83
3.08
1,200
1,200
3.5/5
1.83
3,08
1,200
1,200
3.5/5
1.15
1.91
1,100
1,100
3.5/5
1.15
1,91
1,100
1,100
3.5/5
1.727
1,20
1,100
1,100
3.5/5
0.524
0,868
1,000
1,000
3.5/5
3.084.61
1,500
1,500
AC Voltage Test
Max. Conductor
DC Resistance at 200C
Min.Insulation Resistance
kV/min
Ω /km
Ω /km
MΩ.km
MΩ.km
SHORT CIRCUIT CURRENT
2.69
1.82
1.20
0.81
0.85
0.58
4.49
3.04
2.01
1.36
1.42
0.96
4.49
3.04
2.01
1.36
1.42
0.96
7.18
4.86
3.21
2.17
2.27
1.54
7.18
4.86
3.21
2.17
2.27
1.54
11.23
7.59
5.02
3.39
3.55
2.40
15.72
10.63
7.03
4.75
4.97
3.36
2.69
1.82
1.20
0.81
0.85
0.58
Max. Permissible