Post on 12-May-2020
ARCHITECTURAL DRAWINGS
A
A
11
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
K
K
L
L
90 m²
Multi-purpose Hallfloor tiles
13 m²
Consulting Officefloor tiles
22
44
55
66
77
88
99
1010
1111
12 m²
Consulting Officefloor tiles
10 m²
Sick Bayfloor tiles
33
10 m²
In-takefloor tiles
10 m²
Screeningfloor tiles
10 m²
Cleaner Storefloor tiles
30 m²
Boardroomfloor carpet
29 m²
Staff/Kitchenfloor tiles
12 m²
Consulting Officefloor tiles
12 m²
Consulting Officefloor tiles
15 m²
Community Dev.Supr.floor tiles
38 m²
Com. Dev.Pract.floor tiles
51 m²
Circulation Areafloor tiles
12 m²
Quiet/Obser.floor tiles
15 m²
Group/Interviewfloor tiles
15 m²
Suprv.Social Workerfloor tiles
12 m²
Femalefloor tiles
9 m²
Malefloor tiles
10 m²
Malefloor tiles
13 m²
Femalefloor tiles
4 m²
Paraplegicfloor tiles
10 m²
Store Roomfloor tiles
10 m²
IT/Serverfloor tiles
10 m²
Print Roomfloor tiles
20 m²
Registryfloor tiles
10 m²
Archivefloor tiles
15 m²
Play Roomfloor tiles
10 m²
Store Roomfloor tiles
12 m²
Securityfloor tiles
12 m²
Consulting Officefloor tiles
12 m²
Consulting Officefloor tiles
12 m²
Consulting Officefloor tiles
12 m²
Consulting Officefloor tiles
25 m²
Admin Supp.floor tiles
19 m²
Head Of Facilitiesfloor tiles
25 m²
Meeting Areafloor tiles
15 m²
Meeting Areafloor tiles
6 m
²
Ba
tte
ry B
an
k R
Mfloor
tile
s
11 m²
Stationaryfloor tiles
1212
1313
1414
10 m²
Waiting Areafloor tiles
57 m²
Office Open planfloor tiles
71 m²
Circulation Areafloor tiles
52 m²
Office Open planfloor tiles
49 m²
Waiting Areafloor tiles
20 m²
Receptionfloor tiles
15 m²
Library/Computer Labfloor tiles
PLA
NT
ER
3105
4635
2115
3880
5550
3850
2030
4500
1730
4270
3160
3700
1655
44180
463019154515187598605230639025154515
48035
A200 -REV A
A200 -REV A
B200 -REV A
B200 -REV A
C201 -REV A
C201 -REV A
D201 -REV A
D201 -REV A
4 m²
Paraplegicfloor tiles
baby change
wc
whb
wh
bw
hb
ur
ur
wc
wc wc
whb
wc wc wc wc
whb whb whb
whb whbur
ur
wc
wc
wc
wc
wc
whb
whb
whb
E202 -REV A
E202 -REV A
280
2875
280
4240
345
1835
280
1965
115
1570
230
2690
230
2400
230
4700
230
5600
115
2360
115
2800
115
2800
115
2800
115
2800
345
D02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W03
W01 W01 W01 W01 W01 W01 W01 W01
W02 W02 W02 W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W01
W01
W01
W01
W01
W01
W01
W02W02W02W02
W02W02W02
W02
W02
W02
W02
W02
W02
28 m²
Patiofloor tiles
5 m²
Patiofloor tiles
3 m²
Patiofloor tiles
38 m²
Patiofloor tiles
37 m²
Patiofloor tiles
D02 D03 D04 D04
D03D03D03 D01
D04
D03
D03
D03
D05
D07
D06
D05
D07
D07
D07
D03
D01
D03
D03
D02
D12D09D08
D06
D06
D05D05
D07
D07
D07 D07 D07 D07
D09
D04
D04D03
D03
D12
D03
D01
D03
kitch
en
cabin
ets
to
deta
ils
serv
ice h
atc
h t
o
door
sch
edu
le
Refer to fixed joinery drawings for details on all vanities.
Refer to fixed joinery drawings for details on all vanities.
kitch
en
cabin
ets
to
deta
ils
AL05
AL10
AL02
AL03
AL01
AL04
AL08
AL09
AL12
AL07
AL07
AL07
AL07
AL07
AL07
AL07
AL06
AL11
D11
280
2875
230
4650
230
1590
280850115
2685
230
1585
230875230
2400
230
3620
230
1800
230
1985
230
3300
115
11500
280
1375
345
280
2875
280
6420
280
2000
230
1420
230
1585
230
3505
230
3620
230
4015
230
3300
115
11500
280
1375
345
280
2875
230
6470
280
1700
115
1835
230
9170
230
4015
230
2560
280945
345
1240
9545
280
1720
3435
6420
34720
44575
280 2800 230 2000 230 3745 230
400
280 3475 280 6110 230 5000 280 2750 115 2700 115 3900 2105 6085 345 4400 280
280 900 115 1785 230 2000 230 850115850115850115850 230 1590 280 8675 230 5000 280 9580 230 1645 230 6315 115 4400 280
280 2800 230 1255 230 1800 230 4280 280 8675 230 5000 280 9580 230 1645 230 4285 230 1800 115 4400 280
502581908075678563404035500549101185
48365
280
2875
230
4290
345
3000
115
2685
115
2700
115
2700
115
5765
115
2800
115
3470
115
3500
115
8670
345
280
2875
230
4290
345
1885
230885115
2685
115
2700
115
2700
115
5765
115
2800
115
3470
115
3500
115
5760
280
2630
345
280
10890
345
2270
230
5270
280
3735
115
1800
230
4270
230
5770
230
2930
230
3470
280
1375
345
7675
35180
1720
44575
2804400280158528042852801595230230023023002304520280500028061102802185280444511516352804400280
280 4400 115 6360 280 8575 280 5000 280 9580 230 1645 230 1700 115 2470 280 1750 115 4400 280
280 4400 115 1800 230 4330 280 2185 280 6110 280 5000 280 4520 230 2300 230 2300 230 1645 230 1800 230 925 230 1100 280 1750 115 4400 280
48365
500230
1500
230
9175
255
3620
230
1800
230
2400
230
1640
280
2475
115900230
2000
230900115900115900230
3470
280
1375
345
280
2875
230
7785
345
2270
230
5270
280
2820
230
685
115
1800
230
6000
280
1700
115
1835
230
1585
230
3505
230
3620
230
1800
230
1985
230
3300
115
11500
280
1375
345
10400
230
9170
230
1800
230
4775
280
2530
4285 230 1000 230 1200 230 770 230 2700 230 8675 230 14860 230 1645 230 2855 230 1200 230 1800 115 4400
139052304330230180023012552302800
reception desk to joinery details
secu
rity
cou
nte
r desk join
ery
deta
ils
steel shelving to details. ref. dwg no:
steel shelving to details. ref. dwg no:
steel shelving to details. ref. dwg no:
sin
k
58
m²
Cir
cu
lati
on
Are
afloor
tile
s
7675
500
2995
8115
10660
1845
11065
1720
N
8 m²
Baby changingfloor tiles
Concrete apron to fall away from building as per eng. details
Co
ncre
te a
pro
n t
o f
all
aw
ay f
rom
bu
ildin
g a
s p
er
eng
. d
eta
ils
Co
ncre
te a
pro
n t
o f
all
aw
ay f
rom
bu
ildin
g a
s p
er
eng
. d
eta
ils
Co
ncre
te a
pro
n t
o f
all
aw
ay f
rom
bu
ildin
g a
s p
er
eng
. d
eta
ils
Co
ncre
te a
pro
n t
o f
all
aw
ay f
rom
bu
ildin
g a
s p
er
eng
. d
eta
ils
Co
ncre
te a
pro
n t
o f
all
aw
ay f
rom
bu
ildin
g a
s p
er
eng
. d
eta
ils
Concrete apron to fall away from building as per eng. details
Concrete apron to fall away from building as per eng. details
Concrete apron to fall away from building as per eng. details
Concrete apron to fall away from building as per eng. details
Finishes as per finishing schedule
Finishes as per finishing schedule
Finishes as per finishing schedule
Finishes as per finishing schedule
Finishes as per finishing schedule
Finishes as per finishing schedule
Finishes as per finishing schedule
Finishes as per finishing schedule
Finishes as per finishing schedule
Finishes as per finishing schedule
Finishes as per finishing schedule
Finishes as per finishing schedule
Finishes as per finishing schedule
steel shelving to details. ref. dwg no:
steel shelving to details. ref. dwg no:
Finishes as per finishing schedule
Finishes as per finishing schedule
Finishes as per finishing schedule
Finishes as per finishing schedule
Lin
e o
f ro
of
abo
ve
Lin
e o
f ro
of
abo
ve
Lin
e o
f ro
of
abo
ve
Lin
e o
f ro
of
abo
ve
Lin
e o
f ro
of
abo
ve
Lin
e o
f ro
of
abo
ve
Lin
e o
f ro
of
abo
ve
Lin
e o
f ro
of
abo
ve
Lin
e o
f ro
of
abo
ve
Lin
e o
f ro
of
abo
ve
Line of roof above
Line of roof above
Line of roof above
Line of roof above
Line of roof above
be
am
@2
80
5 t
o
en
gin
ee
r's s
pec
beam above to engineer's spec
be
am
@2
80
5
to e
ng
inee
r's
sp
ec
beam above to engineer's spec
beam above to engineer's spec
be
am
ab
ove t
o e
ng
inee
r's s
pe
c
canopy above to engineer's spec
Concrete column as per engineers details
Concrete roof as per engineers details
Co
ncre
te r
oof
as p
er
en
gin
ee
rs d
eta
ils
Concrete roof as per engineers details
Glass Curtainwall system fixed to aluminiun column
Gla
ss C
urt
ain
wall
syste
m
fixe
d t
o a
lum
iniu
n c
olu
mn
AL13
AL14
Concrete column as per engineers details
beam @2805 to engineer's spec
beam @2805 to engineer's spec
NEW FIRE DOOR
beam above to engineer's spec
be
am
ab
ove
to e
ng
inee
r's
sp
ec
AL13
D08
FHR
D08
230 400230
ur
STEEL column as per engineers details
beam @2805 to engineer's
spec
2101 -
REV A
BABY CHANGE SPEC: Koala stainless steel clad surface mounted horizontal baby changing station with polyethylene interior. Full length steel-on-steel hinges with 11 gauge steel mounting bracket eliminating plastic wear points and providing superior child protection and durability. Gas spring mechanism ensures smooth open and close. Built-in liner cavity and two bag hooks. Includes child safety straps. Bed surface exclusively contains Microban® antimicrobial, reducing odor causing bacteria. ASTM compliant. Meets ADA requirements when mounted properly. Liner dispenser holds 15 liners. Constructed with 55% recycled materials; contributes to LEED certified building requirements.
D10
8675
6590
50x50x5mm Steel Tubing Screen Wall fixed to steel column @150mm c/c spacing, to
receive paint finish by specialist
2301200
D8
DB
D01NEW DUCT
1590
D01
1 : 100
GROUND FLOOR PLAN
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 100
2020/01/20 15:49:28
Designer
GROUND FLOOR PLAN
PROPOSED NEW OFFICES FORLIMPOPO DEPT. OF SOCIAL
DEVELOPMENTTSHILWAVHUSIKU SITE
100 - REV B
Author
Checker
18/KMS/102
B
29.1
1.20
19 1. 2 X NEW FIRE DOORS AT CIRCULATION AREA2. NEW GLASS DOUBLE DOOR AT GRID 103. NEW DUCT AT CIRCULATION AREA
LOWER ROOF LEVEL3060
ROOF PLAN5185
GROUND FLOOR PLAN0
FGHIJKL
3060
2400
3685
425046755185
6205
Archive Battery Bank RM Play Room Waiting Area Circulation Area
foundations to engs details and spec
waterproof membraneto engs details and spec
230mm thick Brickwall Type 6.2 including wall Type 6.5 with an external skin finish Type 7.4
Sheet Metal Roof Type 10. complete with all matching accessories to specialists on new roof structure to engineering details
Reinforced foundation walls to Structural Eng's details
Floor finish Type 5.2 including approved adhersive on cement
sand screed Type 4.3 on reinforced concrete slab to S.E details
Suspended Acoustic ceiling Type 9.4 refer to ceilinglayouts 400 series
Reinforced foundation walls to Structural Eng's details
foundations to engs details and spec
foundations to engs details and spec
foundations to engs details and spec
foundations to engs details and spec
Floor finish Type 5.2 including approved adhersive on cement
sand screed Type 4.3 on reinforced concrete slab to S.E details
Floor finish Type 5.2 including approved adhersive on cement
sand screed Type 4.3 on reinforced concrete slab to S.E details
Reinforced foundation walls to Structural Eng's details
waterproof membraneto engs details and spec
230mm thick Brickwall Type 6.2 including wall Type 6.5 with an external skin finish Type 7.4
230mm thick Brickwall Type 6.2including wall Type 6.5 with an external skin finish Type 7.4
Sheet Metal Roof Type 10. complete with all matching accessories to specialists on new roof structure to engineering details
Concrete roof slab Type 11 to Structural Engineering details.
LOWER ROOF LEVEL3060
ROOF PLAN5185
GROUND FLOOR PLAN0
ABCDE
2400
3060
3685
425046755185
6205
2805
255
Consulting OfficeOffice Open plan
250um polyethylene waterproofing membrane sheeting laid in accordance with
manufacturer's specification
230mm brick wall consisting of inner leaf stock brick and outer leaf face brick bedded in 6:1 cement mortar with birckforce every fourth course. Finished with 4:1 cement plaster, rhinoglide and paint (elsewhere specified) internally. Facebrick to be cleaned
Sheet Metal Roof Type 10. complete with all matching accessories to specialists on new roof structure to engineering details
Extra hard-baked clay bricks laid in strecher bond
with brickforce every second course and bedded
in 6:1 cement mortar
Floor finish Type 5.2 including approved adhersive on cement
sand screed Type 4.3 on reinforced concrete slab to S.E details
Suspended Acoustic ceiling Type 9.4 refer to ceiling
layouts 400 series
Reinforced foundation walls to Structural Eng's details Strip footings as per engineer's
design and specs Provide for the casting and testing of concrete test
cubes as per engineer's requirements
Suspended Acoustic ceiling Type 9.4 refer to ceiling
layouts 400 series
230mm brick wall consisting of inner leaf stock brick and outer leaf face brick bedded in 6:1 cement mortar with birckforce every fourth course. Finished with 4:1 cement plaster, rhinoglide and paint (elsewhere specified) internally. Facebrick to be cleaned
SA Pine Roof trusses as per engineers details and specifications installed onto 114x38 wall plate. Shop drawings to be submitted for approval.
Floor finish as per finishing schedule
Strip footings as per engineer's design and specs Provide for the
casting and testing of concrete test cubes as per engineer's requirements
Strip footings as per engineer's design and specs Provide for the
casting and testing of concrete test cubes as per engineer's requirements
Filling compacted in layers to engineer's specifications provide for
the testing of compaction
5.0
0°
Circulation Area
3.1
375um polyethylene DPC sheeting in appropriate strips laid in strict accordance with the manufacturer's specification under all walls at surface, slab level, and under window sills.
375um polyethylene DPC sheeting in appropriate strips laid in strict accordance with the manufacturer's specification under all walls at surface, slab level, and under window sills.
3.2
3.2 3.2
3.2
3.2
3.2
3.2
3.1 3.13.1
1.1 Earthworks and levels: All siteworks and levels according to civil engineers details.1.2 Paving 1:Approved 65mm interlocking pavers laid as per engineers details and specs
Construction Notes:
The following descriptions / specifications are to be read in conjunction with, and work executed in accordance with OW371 SPECIFICATION OF MATERIALS AND METHODS TO BE USED (as published by the Dept of Public Works October 1993 Edition)
2.1 Column FootingsColumn footing as per engineer's design and specs provide for the casting and testing of concrete test cubes as per engineer's requirements2.2 Concrete strip foundation footings:Strip footings as per engineer's design and specsProvide for the casting and testing of concrete test cubes as per engineer's requirements 2.3 Foundation walls: Extra hard-baked clay bricks laid in strecher bond with brickforce every second course and bedded in 6:1 cement mortar
3.1 Filling:Filling compacted in layers to engineer's specifications provide for the testing of compaction3.2 Insect poison:Applied to foundation trenches and filling in accordance with sabs 1164 / 1165 by specialist. a certificate of guarantee (covering 10 years) to be issued by applicator.
4.1 DPM:250um polyethylene waterproofing membrane sheeting laid in accordance with manufacturer's specification4.2 Surface Bed:125mm 15mpa Reinforced concrete surface bed cast in sections and cut through and casted around columns all in accordance with engineers details and specifications.4.3 Screed:3:1 Cement screed laid on clean surface: overall thickness of screed and floor finish: 25mm (see finishes: floor) where no finish, screed to be finished off smooth with a steel trowel.4.4 Concrete ApronConcrete apron as per engineers details and specifications.
5.1 Grano:40mm thick untinted Granolithic finish composed of one part cement, one part fine sand, two parts coarse sand and one part 5mm exposed granite particles, laid by specialist in panels not exceeding 10m2. including approved brass dividing strips, Floated with a steel trowel to perfectly smooth surface, free from bumps and scratches, and sealed with approved durable surface coat.5.2 Porcelain Tiles:600x600x8mm Full body matt porcelain floor tiles with 2mm joints on full tile cement bedding, in accordance with PW371-A and SANS 13006 group B1a water absorption equal or grater than 0.5%. Grout joints as per BS EN 13006 (PW371) 12.1 (p).
6mm wide movement joints to be observed with patent stainless steel expansion joint strips consisting of synthetic fibre inserts installed to manufacturer's instruction and as marked in the construction drawings.5.3 Porcelain Tiles:600x600x8mm Non-slip Full body exterior porcelain floor tiles with 2mm joints on full tile cement bedding, in accordance with PW371-A and SANS 13006 group B1a water absorption equal or grater than 0.5%. Grout joints as per BS EN 13006 (PW371) 12.1 (p). 6mm wide movement joints to be observed with patent stainless steel expansion joint strips consisting of synthetic fibre inserts installed to manufacturer's instruction and as marked in the construction drawings.
6.1 DPC:375um polyethylene DPC sheeting in appropriate strips laid in strict accordance with the manufacturer's specification under all walls at surface, slab level, and under window sills.6.2 Stock brick:Baked clay bricks in stretcher bond with brickforce every fourth course and bedded in 6:1 cement mortar.6.3 Facebrick Appproved FBX clay facebrick laid in common bond to comply with SABS 227 and forming part of structure.6.5 Internal PlasterWood float plaster to a minimum 12mm 4:1 mixture cement plaster applied to wall. maintain full length structural joints through the plaster and score plaster surfaces to be tiled
6.7 Exterior PlasterWood float plaster to a minimum 12mm 4:1 mixture cement plaster applied to wall. maintain full length structural joints through the plaster and score plaster surfaces to be tiled6.8 Pre-cast lintelsStandard pre-stressed concrete lintel bedded in mortar and extending not less than 225mm on either side of opening. where openings exceed 3000mm in width, 2x12mm reinforcing rods per course (for 230mm wall) and 3x12mm reinforcing rods per course (for 345mm wall) to be laid in 3:1 mortar every course for 4 courses above lintels.6.9 Interior window sills:15mm thick cement window sill firmly bedded in 4:1 cement mortar, slightly projecting 10mm from wall edge and to be tucked below the window frame.10.0 Exterior window sills:Brick-on-edge with wood float plaster to a minimum 12mm 4:1 mixture cement plaster with DPC laid under as per 6.1
7.1 Existing Facebrick Clean and seal the facebrick.Use bucket and brush face brick cleaning method. Clean face brick wall, remove all smudges, seal all holes with the mortar which matches the existing mortar on the wall. Care must be exercised in selecting the proper cleaning solution for the job by getting brick manufacturers' recommendation.
7.2 Exterior Paint:emulsion paint on universal undercoats to exterior new cement plaster (NW 140). Surface to be dry, sound and clean and cured for a minimum of 14 days, with a moisture content measured with a Doser Hygrometer (or equal), of BD 2 scale - 8% or less. apply one coat ofalkali-resistant primer SANS 1416, one coat universal undercoat SANS 681 with an over-coating time of 16 hours and finish with two coats matt, high-opacity finish "contract" emulsion paint SANS 1586 grade 4 with 2 hours drying time between coats, for a maintenance cycle of 7 years - inland environment. restrict paint to one manufacturer. complete paint systems - primer, undercoat and finishing coat to be recommended by same supplier. exterior quality to be used for exterior work 7.3 Interior Paint (PVA Acrylic):emulsion paint on universal undercoats to exterior new cement plaster. Surface to be dry, sound and clean and cured for a minimum of 14 days, with a moisture content measured with a Doser Hygrometer (or equal), of BD 2 scale -8% or less. apply one coat ofalkali-resistant primer SANS 1416, one coat universal undercoat SANS 681 with an over-coating time of 16 hours and finish with two coats matt, high-opacity finish "contract" emulsion paint SANS 1586 grade 4 with 2 hours drying time between coats, for a maintenance cycle of 7 years -inland environment. restrict paint to one manufacturer. complete paint systems - primer, undercoat and finishing coat to be recommended by same supplier. interior quality to be used for interior work
7.4 Textured plaster:12mm cement plaster to recieve MARMORAN strictly in accordance with manufacturer's specifications.7.5 Halfbody Porcelain Tiles:Half body 600x300mm porcelain tiles laid in true straight, vertical and horizontal 2mm joints, including patent stainless steel corner stirps; in approved tile bedding adhesive in accordance with PW 371-A 12.1 (n and o). Finish off joints with grout in accordance with PW 371-A 12.1 (p and q) and SANS 10107. Colour to architects' approval.7.6 Marble tiles:600x600x20mm marble tiles laid in true straight, vertical and horizontal butt jointed, including patent stainless steel corner stirps.; in approved tile bedding adhesive in accordance with PW 371-A 12.1 (n and o). Colour to architects' approval7.7 Skirting:600mm wide x 100mm high x 8mm thick matt porcelain tile to comply with SABS 1449 laid on approved adhesives and grout in strict compliance to manufacturers instructions and SABS specification. Complete with corner and top stainless steel trims. Colour to architects' approval.
8.1 ColumnsConcrete columns as per engineer details and specifications.8.2 Concrete Gutter600x340mm Concrete gutter as per engineers details and specifications.8.3 Concrete BeamConcrete beam as per engineers details and specifications8.4 Steel BeamSteel beam as per engineers details and specifications8.5 Steel ColumnSteel column as per engineers details and specifications
9.1 Ceiling type A (plasterboard)1200x2400x9.5mm gypsum tapered edged ceiling boards secured to 38x38mm pine brandering with Sharp Point Screws 35mm at maximum 150mm centres. Boards tightly butted together and installed with the longer side running perpendicular to the direction of brandering. The boards shall be installed with the shorter side joints staggered by at least 300mm and centered on ceiling framework. Boards shall be installed with printed side up and all joints to be taped and skimmed with 3mm patent lightweight plaster on the same day as boards have been erected and plaster shall be finished to smooth polished surface to ensure a smooth unblemished ceiling surface ceiling edged with coved cornice. Seal with a full coat of plaster primer and apply 2x coats of emulsion paint, in accordance with PW 371-A 9.1.2 (a-r) Joint strips to be installed in areas where ceiling is not plastered.
9.2 Ceiling type B (600x600 Vinyl)Biologically absorbable mineral wool ceiling
tiles, size 600x600x15mm thick with square edge and white vinyl finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions. 9.3 Ceiling type C (600x600 acoustic)Biologically absorbable mineral wool ceiling tiles, size 600x 600x15mm thick with square edge and white painted finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions.9.4 Ceiling type D (600x1200 acoustic)Biologically absorbable mineral wool ceiling tiles, size 600x1200x15mm thick with square edge and white painted finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions.
9.5 Ceiling type E (Concrete soffit)Underside of concrete slab to receive ripple paint Colour as per architect.9.6 Ceiling type F (Isoboard)12x7900x50mm isoboard high density thermal insulation boards with beveled and shiplap edges fixed to purling on the underside of the steel trusses9.7 Ceiling type G (Trap door)Trap door: Fibre cement 600x600x2mm with 38x38mm SA Pine surround and cross bracing to inside fit into 600x600mm frame constructed of 114x38 SA Pine fixed between trusses.
10.1 Trusses:Steel trusses per engineers design and specifications .10.2 Sheeting:Kliplok with chromadek finish roof sheets fixed to steel purlins per engineers design and specifications10.3 Flashings:Flashing as per manufacturer's details and specifications.10.4 Fascia:steel fascia in areas marked on the drawings as per manufacturer's details and specifications.10.5 Sheet Metal Gutters:Chromadek sheet metal gutter fixed to steel trusses in areas marked on drawings and according to manufactuers' details and specification.10.6 Downpipe 1:
∅100mm Sheet metal downpipe with chromadek finish, downpipe to be fixed to wall with brackets matching the down pipes. Colour to match sheeting.
10.7 Downpipe 2:
∅160mm Sheet metal downpipe with chromadek finish, downpipe to be fixed to wall with brackets matching the down pipes. Colour to match sheeting.10.8 CertificatesA certificate from the fixing contractor as well as a seperate certificate from the sheeting supplier must be submitted before final completion certificate will
11.1 Concrete slabConcrete slab as per structural engineers details and specifications.11.2 Screed:3:1 Cement Screed laid on clean surface with falls to fullbore outlets.11.3 Waterproofing:One layer of bitumen waterproofing membrane, with 75mm side laps and 100mm end laps and sealed to primed surface to falls and crossfalls by "torchfusion" . bitumen waterproofing to be applied on concrete which already has waterproof cement additives. Waterproofing to be installed by an approved manufacturer's contractor under a ten year guarantee.
7. Wall Finishes Cont.:7. Wall Finishes Cont.:
7. Wall Finishes:
6. Wall Construction:
5. Floor Finish Cont.: 8. Concrete/Steel Structure:
9. Ceiling:
9. Ceiling cont.: 9. Ceiling cont.:
10. Sheet Metal Roof:
10. Sheet Metal Roof cont.:
11. Concrete Roof:
5. Floor Finish:
4. Floor Construction:
3. Back Filling:
2. Foundations:
1. External Site works: 6. Wall Construction Cont.:
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 50
2019/10/16 11:58:44
Designer
SECTIONS AA AND BB
LDSD DESIGN PROTOTYPES
200 -REV A
Author
Checker
18/KMS/102
1 : 50
SECTION AA
1 : 50
SECTION BB
1.1 Earthworks and levels: All siteworks and levels according to civil engineers details.1.2 Paving 1:Approved 65mm interlocking pavers laid as per engineers details and specs
Construction Notes:
The following descriptions / specifications are to be read in conjunction with, and work executed in accordance with OW371 SPECIFICATION OF MATERIALS AND METHODS TO BE USED (as published by the Dept of Public Works October 1993 Edition)
2.1 Column FootingsColumn footing as per engineer's design and specs provide for the casting and testing of concrete test cubes as per engineer's requirements2.2 Concrete strip foundation footings:Strip footings as per engineer's design and specsProvide for the casting and testing of concrete test cubes as per engineer's requirements 2.3 Foundation walls: Extra hard-baked clay bricks laid in strecher bond with brickforce every second course and bedded in 6:1 cement mortar
3.1 Filling:Filling compacted in layers to engineer's specifications provide for the testing of compaction3.2 Insect poison:Applied to foundation trenches and filling in accordance with sabs 1164 / 1165 by specialist. a certificate of guarantee (covering 10 years) to be issued by applicator.
4.1 DPM:250um polyethylene waterproofing membrane sheeting laid in accordance with manufacturer's specification4.2 Surface Bed:125mm 15mpa Reinforced concrete surface bed cast in sections and cut through and casted around columns all in accordance with engineers details and specifications.4.3 Screed:3:1 Cement screed laid on clean surface: overall thickness of screed and floor finish: 25mm (see finishes: floor) where no finish, screed to be finished off smooth with a steel trowel.4.4 Concrete ApronConcrete apron as per engineers details and specifications.
5.1 Grano:40mm thick untinted Granolithic finish composed of one part cement, one part fine sand, two parts coarse sand and one part 5mm exposed granite particles, laid by specialist in panels not exceeding 10m2. including approved brass dividing strips, Floated with a steel trowel to perfectly smooth surface, free from bumps and scratches, and sealed with approved durable surface coat.5.2 Porcelain Tiles:600x600x8mm Full body matt porcelain floor tiles with 2mm joints on full tile cement bedding, in accordance with PW371-A and SANS 13006 group B1a water absorption equal or grater than 0.5%. Grout joints as per BS EN 13006 (PW371) 12.1 (p).
6mm wide movement joints to be observed with patent stainless steel expansion joint strips consisting of synthetic fibre inserts installed to manufacturer's instruction and as marked in the construction drawings.5.3 Porcelain Tiles:600x600x8mm Non-slip Full body exterior porcelain floor tiles with 2mm joints on full tile cement bedding, in accordance with PW371-A and SANS 13006 group B1a water absorption equal or grater than 0.5%. Grout joints as per BS EN 13006 (PW371) 12.1 (p). 6mm wide movement joints to be observed with patent stainless steel expansion joint strips consisting of synthetic fibre inserts installed to manufacturer's instruction and as marked in the construction drawings.
6.1 DPC:375um polyethylene DPC sheeting in appropriate strips laid in strict accordance with the manufacturer's specification under all walls at surface, slab level, and under window sills.6.2 Stock brick:Baked clay bricks in stretcher bond with brickforce every fourth course and bedded in 6:1 cement mortar.6.3 Facebrick Appproved FBX clay facebrick laid in common bond to comply with SABS 227 and forming part of structure.6.5 Internal PlasterWood float plaster to a minimum 12mm 4:1 mixture cement plaster applied to wall. maintain full length structural joints through the plaster and score plaster surfaces to be tiled
6.7 Exterior PlasterWood float plaster to a minimum 12mm 4:1 mixture cement plaster applied to wall. maintain full length structural joints through the plaster and score plaster surfaces to be tiled6.8 Pre-cast lintelsStandard pre-stressed concrete lintel bedded in mortar and extending not less than 225mm on either side of opening. where openings exceed 3000mm in width, 2x12mm reinforcing rods per course (for 230mm wall) and 3x12mm reinforcing rods per course (for 345mm wall) to be laid in 3:1 mortar every course for 4 courses above lintels.6.9 Interior window sills:15mm thick cement window sill firmly bedded in 4:1 cement mortar, slightly projecting 10mm from wall edge and to be tucked below the window frame.10.0 Exterior window sills:Brick-on-edge with wood float plaster to a minimum 12mm 4:1 mixture cement plaster with DPC laid under as per 6.1
7.1 Existing Facebrick Clean and seal the facebrick.Use bucket and brush face brick cleaning method. Clean face brick wall, remove all smudges, seal all holes with the mortar which matches the existing mortar on the wall. Care must be exercised in selecting the proper cleaning solution for the job by getting brick manufacturers' recommendation.
7.2 Exterior Paint:emulsion paint on universal undercoats to exterior new cement plaster (NW 140). Surface to be dry, sound and clean and cured for a minimum of 14 days, with a moisture content measured with a Doser Hygrometer (or equal), of BD 2 scale - 8% or less. apply one coat ofalkali-resistant primer SANS 1416, one coat universal undercoat SANS 681 with an over-coating time of 16 hours and finish with two coats matt, high-opacity finish "contract" emulsion paint SANS 1586 grade 4 with 2 hours drying time between coats, for a maintenance cycle of 7 years - inland environment. restrict paint to one manufacturer. complete paint systems - primer, undercoat and finishing coat to be recommended by same supplier. exterior quality to be used for exterior work 7.3 Interior Paint (PVA Acrylic):emulsion paint on universal undercoats to exterior new cement plaster. Surface to be dry, sound and clean and cured for a minimum of 14 days, with a moisture content measured with a Doser Hygrometer (or equal), of BD 2 scale -8% or less. apply one coat ofalkali-resistant primer SANS 1416, one coat universal undercoat SANS 681 with an over-coating time of 16 hours and finish with two coats matt, high-opacity finish "contract" emulsion paint SANS 1586 grade 4 with 2 hours drying time between coats, for a maintenance cycle of 7 years -inland environment. restrict paint to one manufacturer. complete paint systems - primer, undercoat and finishing coat to be recommended by same supplier. interior quality to be used for interior work
7.4 Textured plaster:12mm cement plaster to recieve MARMORAN strictly in accordance with manufacturer's specifications.7.5 Halfbody Porcelain Tiles:Half body 600x300mm porcelain tiles laid in true straight, vertical and horizontal 2mm joints, including patent stainless steel corner stirps; in approved tile bedding adhesive in accordance with PW 371-A 12.1 (n and o). Finish off joints with grout in accordance with PW 371-A 12.1 (p and q) and SANS 10107. Colour to architects' approval.7.6 Marble tiles:600x600x20mm marble tiles laid in true straight, vertical and horizontal butt jointed, including patent stainless steel corner stirps.; in approved tile bedding adhesive in accordance with PW 371-A 12.1 (n and o). Colour to architects' approval7.7 Skirting:600mm wide x 100mm high x 8mm thick matt porcelain tile to comply with SABS 1449 laid on approved adhesives and grout in strict compliance to manufacturers instructions and SABS specification. Complete with corner and top stainless steel trims. Colour to architects' approval.
8.1 ColumnsConcrete columns as per engineer details and specifications.8.2 Concrete Gutter600x340mm Concrete gutter as per engineers details and specifications.8.3 Concrete BeamConcrete beam as per engineers details and specifications8.4 Steel BeamSteel beam as per engineers details and specifications8.5 Steel ColumnSteel column as per engineers details and specifications
9.1 Ceiling type A (plasterboard)1200x2400x9.5mm gypsum tapered edged ceiling boards secured to 38x38mm pine brandering with Sharp Point Screws 35mm at maximum 150mm centres. Boards tightly butted together and installed with the longer side running perpendicular to the direction of brandering. The boards shall be installed with the shorter side joints staggered by at least 300mm and centered on ceiling framework. Boards shall be installed with printed side up and all joints to be taped and skimmed with 3mm patent lightweight plaster on the same day as boards have been erected and plaster shall be finished to smooth polished surface to ensure a smooth unblemished ceiling surface ceiling edged with coved cornice. Seal with a full coat of plaster primer and apply 2x coats of emulsion paint, in accordance with PW 371-A 9.1.2 (a-r) Joint strips to be installed in areas where ceiling is not plastered.
9.2 Ceiling type B (600x600 Vinyl)Biologically absorbable mineral wool ceiling
tiles, size 600x600x15mm thick with square edge and white vinyl finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions. 9.3 Ceiling type C (600x600 acoustic)Biologically absorbable mineral wool ceiling tiles, size 600x 600x15mm thick with square edge and white painted finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions.9.4 Ceiling type D (600x1200 acoustic)Biologically absorbable mineral wool ceiling tiles, size 600x1200x15mm thick with square edge and white painted finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions.
9.5 Ceiling type E (Concrete soffit)Underside of concrete slab to receive ripple paint Colour as per architect.9.6 Ceiling type F (Isoboard)12x7900x50mm isoboard high density thermal insulation boards with beveled and shiplap edges fixed to purling on the underside of the steel trusses9.7 Ceiling type G (Trap door)Trap door: Fibre cement 600x600x2mm with 38x38mm SA Pine surround and cross bracing to inside fit into 600x600mm frame constructed of 114x38 SA Pine fixed between trusses.
10.1 Trusses:Steel trusses per engineers design and specifications .10.2 Sheeting:Kliplok with chromadek finish roof sheets fixed to steel purlins per engineers design and specifications10.3 Flashings:Flashing as per manufacturer's details and specifications.10.4 Fascia:steel fascia in areas marked on the drawings as per manufacturer's details and specifications.10.5 Sheet Metal Gutters:Chromadek sheet metal gutter fixed to steel trusses in areas marked on drawings and according to manufactuers' details and specification.10.6 Downpipe 1:
∅100mm Sheet metal downpipe with chromadek finish, downpipe to be fixed to wall with brackets matching the down pipes. Colour to match sheeting.
10.7 Downpipe 2:
∅160mm Sheet metal downpipe with chromadek finish, downpipe to be fixed to wall with brackets matching the down pipes. Colour to match sheeting.10.8 CertificatesA certificate from the fixing contractor as well as a seperate certificate from the sheeting supplier must be submitted before final completion certificate will
11.1 Concrete slabConcrete slab as per structural engineers details and specifications.11.2 Screed:3:1 Cement Screed laid on clean surface with falls to fullbore outlets.11.3 Waterproofing:One layer of bitumen waterproofing membrane, with 75mm side laps and 100mm end laps and sealed to primed surface to falls and crossfalls by "torchfusion" . bitumen waterproofing to be applied on concrete which already has waterproof cement additives. Waterproofing to be installed by an approved manufacturer's contractor under a ten year guarantee.
7. Wall Finishes Cont.:7. Wall Finishes Cont.:
7. Wall Finishes:
6. Wall Construction:
5. Floor Finish Cont.: 8. Concrete/Steel Structure:
9. Ceiling:
9. Ceiling cont.: 9. Ceiling cont.:
10. Sheet Metal Roof:
10. Sheet Metal Roof cont.:
11. Concrete Roof:
5. Floor Finish:
4. Floor Construction:
3. Back Filling:
2. Foundations:
1. External Site works: 6. Wall Construction Cont.:
LOWER ROOF LEVEL3060
GROUND FLOOR PLAN0
5 6 7 8 9
UPPER ROOF PLAN4675
2400
3060
3685
425046755185
6205
Head Of Facilities Circulation Area Screening
foundations to engs details and spec
waterproof membraneto engs details and spec
230mm thick Brickwall Type 6.2 including wall Type 6.5 with an external skin finish Type 7.4
Sheet Metal Roof Type 10. complete with all matching accessories to specialists on new roof structure to engineering details
Reinforced foundation walls to Structural Eng's detailsFloor finish Type 5.2 including
approved adhersive on cement sand screed Type 4.3 on reinforced
concrete slab to S.E details
Suspended Acoustic ceiling Type 9.4 refer to ceilinglayouts 400 series
Reinforced foundation walls to Structural Eng's details
Floor finish Type 5.2 including approved adhersive on cement
sand screed Type 4.3 on reinforced concrete slab to S.E details
waterproof membraneto engs details and spec
230mm thick Brickwall Type 6.2 including wall Type 6.5 with an external skin finish Type 7.4
foundations to engs details and spec
foundations to engs details and spec
Suspended Acoustic ceiling Type 9.4 refer to ceilinglayouts 400 series
LOWER ROOF LEVEL3060
ROOF PLAN5185
GROUND FLOOR PLAN0
FGHIJK
UPPER ROOF PLAN4675
2400
3685
3060
425046755185
6205
Multi-purpose Hall
foundations to engs details and spec
waterproof membraneto engs details and spec
230mm thick Brickwall Type 6.2 including wall Type 6.5 with an external skin finish Type 7.4
Sheet Metal Roof Type 10. complete with all matching accessories to specialists on new roof structure to engineering details
Reinforced foundation walls to Structural Eng's details
Floor finish Type 5.2 including approved adhersive on cement
sand screed Type 4.3 on reinforced concrete slab to S.E details
Suspended Acoustic ceiling Type 9.4 refer to ceilinglayouts 400 series
Reinforced foundation walls to Structural Eng's details
foundations to engs details and spec
foundations to engs details and spec
conc upstand to engs details and spec
Concrete roof slab Type 11 to Structural Engineering details.
4mm fully torched waterproofing as specified laid on screeds laid
to falls to roof outlets as per engs layouts
3620
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 50
2019/10/16 11:58:46
Designer
SECTION CC AND DD
LDSD DESIGN PROTOTYPES
201 -REV A
Author
Checker
18/KMS/102
1 : 50
SECTION CC
1 : 50
SECTION DD
1.1 Earthworks and levels: All siteworks and levels according to civil engineers details.1.2 Paving 1:Approved 65mm interlocking pavers laid as per engineers details and specs
Construction Notes:
The following descriptions / specifications are to be read in conjunction with, and work executed in accordance with OW371 SPECIFICATION OF MATERIALS AND METHODS TO BE USED (as published by the Dept of Public Works October 1993 Edition)
2.1 Column FootingsColumn footing as per engineer's design and specs provide for the casting and testing of concrete test cubes as per engineer's requirements2.2 Concrete strip foundation footings:Strip footings as per engineer's design and specsProvide for the casting and testing of concrete test cubes as per engineer's requirements 2.3 Foundation walls: Extra hard-baked clay bricks laid in strecher bond with brickforce every second course and bedded in 6:1 cement mortar
3.1 Filling:Filling compacted in layers to engineer's specifications provide for the testing of compaction3.2 Insect poison:Applied to foundation trenches and filling in accordance with sabs 1164 / 1165 by specialist. a certificate of guarantee (covering 10 years) to be issued by applicator.
4.1 DPM:250um polyethylene waterproofing membrane sheeting laid in accordance with manufacturer's specification4.2 Surface Bed:125mm 15mpa Reinforced concrete surface bed cast in sections and cut through and casted around columns all in accordance with engineers details and specifications.4.3 Screed:3:1 Cement screed laid on clean surface: overall thickness of screed and floor finish: 25mm (see finishes: floor) where no finish, screed to be finished off smooth with a steel trowel.4.4 Concrete ApronConcrete apron as per engineers details and specifications.
5.1 Grano:40mm thick untinted Granolithic finish composed of one part cement, one part fine sand, two parts coarse sand and one part 5mm exposed granite particles, laid by specialist in panels not exceeding 10m2. including approved brass dividing strips, Floated with a steel trowel to perfectly smooth surface, free from bumps and scratches, and sealed with approved durable surface coat.5.2 Porcelain Tiles:600x600x8mm Full body matt porcelain floor tiles with 2mm joints on full tile cement bedding, in accordance with PW371-A and SANS 13006 group B1a water absorption equal or grater than 0.5%. Grout joints as per BS EN 13006 (PW371) 12.1 (p).
6mm wide movement joints to be observed with patent stainless steel expansion joint strips consisting of synthetic fibre inserts installed to manufacturer's instruction and as marked in the construction drawings.5.3 Porcelain Tiles:600x600x8mm Non-slip Full body exterior porcelain floor tiles with 2mm joints on full tile cement bedding, in accordance with PW371-A and SANS 13006 group B1a water absorption equal or grater than 0.5%. Grout joints as per BS EN 13006 (PW371) 12.1 (p). 6mm wide movement joints to be observed with patent stainless steel expansion joint strips consisting of synthetic fibre inserts installed to manufacturer's instruction and as marked in the construction drawings.
6.1 DPC:375um polyethylene DPC sheeting in appropriate strips laid in strict accordance with the manufacturer's specification under all walls at surface, slab level, and under window sills.6.2 Stock brick:Baked clay bricks in stretcher bond with brickforce every fourth course and bedded in 6:1 cement mortar.6.3 Facebrick Appproved FBX clay facebrick laid in common bond to comply with SABS 227 and forming part of structure.6.5 Internal PlasterWood float plaster to a minimum 12mm 4:1 mixture cement plaster applied to wall. maintain full length structural joints through the plaster and score plaster surfaces to be tiled
6.7 Exterior PlasterWood float plaster to a minimum 12mm 4:1 mixture cement plaster applied to wall. maintain full length structural joints through the plaster and score plaster surfaces to be tiled6.8 Pre-cast lintelsStandard pre-stressed concrete lintel bedded in mortar and extending not less than 225mm on either side of opening. where openings exceed 3000mm in width, 2x12mm reinforcing rods per course (for 230mm wall) and 3x12mm reinforcing rods per course (for 345mm wall) to be laid in 3:1 mortar every course for 4 courses above lintels.6.9 Interior window sills:15mm thick cement window sill firmly bedded in 4:1 cement mortar, slightly projecting 10mm from wall edge and to be tucked below the window frame.10.0 Exterior window sills:Brick-on-edge with wood float plaster to a minimum 12mm 4:1 mixture cement plaster with DPC laid under as per 6.1
7.1 Existing Facebrick Clean and seal the facebrick.Use bucket and brush face brick cleaning method. Clean face brick wall, remove all smudges, seal all holes with the mortar which matches the existing mortar on the wall. Care must be exercised in selecting the proper cleaning solution for the job by getting brick manufacturers' recommendation.
7.2 Exterior Paint:emulsion paint on universal undercoats to exterior new cement plaster (NW 140). Surface to be dry, sound and clean and cured for a minimum of 14 days, with a moisture content measured with a Doser Hygrometer (or equal), of BD 2 scale - 8% or less. apply one coat ofalkali-resistant primer SANS 1416, one coat universal undercoat SANS 681 with an over-coating time of 16 hours and finish with two coats matt, high-opacity finish "contract" emulsion paint SANS 1586 grade 4 with 2 hours drying time between coats, for a maintenance cycle of 7 years - inland environment. restrict paint to one manufacturer. complete paint systems - primer, undercoat and finishing coat to be recommended by same supplier. exterior quality to be used for exterior work 7.3 Interior Paint (PVA Acrylic):emulsion paint on universal undercoats to exterior new cement plaster. Surface to be dry, sound and clean and cured for a minimum of 14 days, with a moisture content measured with a Doser Hygrometer (or equal), of BD 2 scale -8% or less. apply one coat ofalkali-resistant primer SANS 1416, one coat universal undercoat SANS 681 with an over-coating time of 16 hours and finish with two coats matt, high-opacity finish "contract" emulsion paint SANS 1586 grade 4 with 2 hours drying time between coats, for a maintenance cycle of 7 years -inland environment. restrict paint to one manufacturer. complete paint systems - primer, undercoat and finishing coat to be recommended by same supplier. interior quality to be used for interior work
7.4 Textured plaster:12mm cement plaster to recieve MARMORAN strictly in accordance with manufacturer's specifications.7.5 Halfbody Porcelain Tiles:Half body 600x300mm porcelain tiles laid in true straight, vertical and horizontal 2mm joints, including patent stainless steel corner stirps; in approved tile bedding adhesive in accordance with PW 371-A 12.1 (n and o). Finish off joints with grout in accordance with PW 371-A 12.1 (p and q) and SANS 10107. Colour to architects' approval.7.6 Marble tiles:600x600x20mm marble tiles laid in true straight, vertical and horizontal butt jointed, including patent stainless steel corner stirps.; in approved tile bedding adhesive in accordance with PW 371-A 12.1 (n and o). Colour to architects' approval7.7 Skirting:600mm wide x 100mm high x 8mm thick matt porcelain tile to comply with SABS 1449 laid on approved adhesives and grout in strict compliance to manufacturers instructions and SABS specification. Complete with corner and top stainless steel trims. Colour to architects' approval.
8.1 ColumnsConcrete columns as per engineer details and specifications.8.2 Concrete Gutter600x340mm Concrete gutter as per engineers details and specifications.8.3 Concrete BeamConcrete beam as per engineers details and specifications8.4 Steel BeamSteel beam as per engineers details and specifications8.5 Steel ColumnSteel column as per engineers details and specifications
9.1 Ceiling type A (plasterboard)1200x2400x9.5mm gypsum tapered edged ceiling boards secured to 38x38mm pine brandering with Sharp Point Screws 35mm at maximum 150mm centres. Boards tightly butted together and installed with the longer side running perpendicular to the direction of brandering. The boards shall be installed with the shorter side joints staggered by at least 300mm and centered on ceiling framework. Boards shall be installed with printed side up and all joints to be taped and skimmed with 3mm patent lightweight plaster on the same day as boards have been erected and plaster shall be finished to smooth polished surface to ensure a smooth unblemished ceiling surface ceiling edged with coved cornice. Seal with a full coat of plaster primer and apply 2x coats of emulsion paint, in accordance with PW 371-A 9.1.2 (a-r) Joint strips to be installed in areas where ceiling is not plastered.
9.2 Ceiling type B (600x600 Vinyl)Biologically absorbable mineral wool ceiling
tiles, size 600x600x15mm thick with square edge and white vinyl finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions. 9.3 Ceiling type C (600x600 acoustic)Biologically absorbable mineral wool ceiling tiles, size 600x 600x15mm thick with square edge and white painted finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions.9.4 Ceiling type D (600x1200 acoustic)Biologically absorbable mineral wool ceiling tiles, size 600x1200x15mm thick with square edge and white painted finish, laid on fire rated exposed demountable suspension system, comprising powder coated main tees and cross tees at with main tees suspended by means of galvanised hangers at centres not exceeding 1200mm with ceiling perimeter finished with Perimeter L-trim, plugged and screwed at 200mm centres, and all installed to manufacturer's instructions.
9.5 Ceiling type E (Concrete soffit)Underside of concrete slab to receive ripple paint Colour as per architect.9.6 Ceiling type F (Isoboard)12x7900x50mm isoboard high density thermal insulation boards with beveled and shiplap edges fixed to purling on the underside of the steel trusses9.7 Ceiling type G (Trap door)Trap door: Fibre cement 600x600x2mm with 38x38mm SA Pine surround and cross bracing to inside fit into 600x600mm frame constructed of 114x38 SA Pine fixed between trusses.
10.1 Trusses:Steel trusses per engineers design and specifications .10.2 Sheeting:Kliplok with chromadek finish roof sheets fixed to steel purlins per engineers design and specifications10.3 Flashings:Flashing as per manufacturer's details and specifications.10.4 Fascia:steel fascia in areas marked on the drawings as per manufacturer's details and specifications.10.5 Sheet Metal Gutters:Chromadek sheet metal gutter fixed to steel trusses in areas marked on drawings and according to manufactuers' details and specification.10.6 Downpipe 1:
∅100mm Sheet metal downpipe with chromadek finish, downpipe to be fixed to wall with brackets matching the down pipes. Colour to match sheeting.
10.7 Downpipe 2:
∅160mm Sheet metal downpipe with chromadek finish, downpipe to be fixed to wall with brackets matching the down pipes. Colour to match sheeting.10.8 CertificatesA certificate from the fixing contractor as well as a seperate certificate from the sheeting supplier must be submitted before final completion certificate will
11.1 Concrete slabConcrete slab as per structural engineers details and specifications.11.2 Screed:3:1 Cement Screed laid on clean surface with falls to fullbore outlets.11.3 Waterproofing:One layer of bitumen waterproofing membrane, with 75mm side laps and 100mm end laps and sealed to primed surface to falls and crossfalls by "torchfusion" . bitumen waterproofing to be applied on concrete which already has waterproof cement additives. Waterproofing to be installed by an approved manufacturer's contractor under a ten year guarantee.
7. Wall Finishes Cont.:7. Wall Finishes Cont.:
7. Wall Finishes:
6. Wall Construction:
5. Floor Finish Cont.: 8. Concrete/Steel Structure:
9. Ceiling:
9. Ceiling cont.: 9. Ceiling cont.:
10. Sheet Metal Roof:
10. Sheet Metal Roof cont.:
11. Concrete Roof:
5. Floor Finish:
4. Floor Construction:
3. Back Filling:
2. Foundations:
1. External Site works: 6. Wall Construction Cont.:
LOWER ROOF LEVEL3060
GROUND FLOOR PLAN0
F G
H I J K L
Level 263685
UPPER ROOF PLAN4675
2400
3060
3685
425046755185
6205
Office Open plan Consulting OfficeCirculation Area
waterproof membraneto engs details and spec
230mm thick Brickwall Type 6.2 including wall Type 6.5 with an external skin finish Type 7.4
Sheet Metal Roof Type 10. complete with all matching accessories to specialists on new roof structure to engineering details
Reinforced foundation walls to Structural Eng's details
Floor finish Type 5.2 including approved adhersive on cement
sand screed Type 4.3 on reinforced concrete slab to S.E details
Suspended Acoustic ceiling Type 9.4 refer to ceilinglayouts 400 series
Reinforced foundation walls to Structural Eng's details
foundations to engs details and spec
foundations to engs details and spec
foundations to engs details and spec
Floor finish Type 5.2 including approved adhersive on cement
sand screed Type 4.3 on reinforced concrete slab to S.E details
waterproof membraneto engs details and spec
Suspended Acoustic ceiling Type 9.4 refer to ceilinglayouts 400 series
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 50
2019/10/16 11:58:47
Designer
SECTION EE
LDSD DESIGN PROTOTYPES
202 -REV A
Author
Checker
18/KMS/102
1 : 50
SECTION EE
LOWER ROOF LEVEL
3060
ROOF PLAN
5185
GROUND FLOOR PLAN
0
A B C D E
F G H I J K L
2400
3060
3685
4250
4675
51856205
5702 - REV A
LOWER ROOF LEVEL
3060
ROOF PLAN
5185
GROUND FLOOR PLAN
0
ABCDE
FGHIJKL
2400
3060
3685
4250
4675
51856205
5702 - REV A
LOWER ROOF LEVEL
3060
ROOF PLAN
5185
GROUND FLOOR PLAN
0
1 2 4 5 6 7 8 9 10 113 12 13 14
2400
3060
3685
425051856205 9
701 - REV A
LOWER ROOF LEVEL
3060
ROOF PLAN
5185
GROUND FLOOR PLAN
0
124567891011 3121314
2400
3060
3685
4250
4675
51856205 9
701 - REV A
1 : 100
NORTH ELEVATION
1 : 100
SOUTH ELEVATION
1 : 100
WEST ELEVATION
1 : 100
EAST ELEVATIONClient
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 100
2019/10/16 11:58:52
Designer
ELEVATION
LDSD DESIGN PROTOTYPES
300 -REV A
Author
Checker
18/KMS/102
9.3 CEILING TYPE C (ACOUSTIC)OWA SANDILE 600 x 1200 ( 15mm thk ) LAYING CEILING TILES ON A DONN EXPOSED GRID (T38) MAIN TEES AND T25 CROSS TEES WITH CAPPINGS OF PREPAINTED ALUMINIUM GRID SUSPENDED FROM CONCRETE SLAB OR TRUSSES WITH METAL HANGERS ALL AS PER MANUFACTURERS REQUIREMENTSCEILING EDGED WITH A PREPAINTED SHADOWLINE CORNICE
9.5 CEILING TYPE E UNDERSIDE OF CONCRETE SLAB TO RECEIVE RIPPLE PAINT COLOUR AS PER ARCHITECT.
CEILING LENGED:
9.1 CEILING TYPE A 9.5mm RHINO PLASTERBOARD TAPERED EDGED CEILING BOARDS SECURED TO A DONN SUSPENDED HIDDEN "T" STEEL GRID SYSTEM GRID SUSPENDED FROM CONCRETE SLAB WITH 25X25 METAL ANGLE HANGERS ALL AS PER MANUFACTURERS REQUIREMENTS BOARDS INSTALLED WITH PRINTED SIDE UP AND ALL JOINTS TO BE TAPED (RHINO TAPE) AND SCIMMED WITH RHINOLITE OR CRETESTONE PLASTER ALL DONE IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS TO ENSURE A SMOOTH UNBLEMISHED CEILING SURFACE CEILING EDGED WITH A PREPAINTED SHADOWLINE CORNICE
9.4 CEILING TYPE D OWA SANDILE 1200 x 600 ( 15mm thk ) LAYING CEILING TILES ON A DONN EXPOSED GRID (T38) MAIN TEES AND T25 CROSS TEES WITH CAPPINGS OF PREPAINTED ALUMINIUM GRID SUSPENDED FROM CONCRETE SLAB OR TRUSSES WITH METAL HANGERS ALL AS PER MANUFACTURERS REQUIREMENTSCEILING EDGED WITH A PREPAINTED SHADOWLINE CORNICE
9.9 CEILING TYPE F LAMINATED POLYISOCYANURATE CORE BOARD WITH A MINIMUM OF 34KG/M3, THICKNESS OF 40mm; FACED WITH WHITE MINERAL LAMINATED ON BOTH SIDES IN WIDTHS OF 1220mm. OVER PURLIN TRUSS INSTALLATION TO BE FIXED IN STRICT ACCORDINCE TO MITEK DESIGN DETAILS
9.4 CEILING TYPE B GYPREX FISSURED 600 x 600 (12.5 mm thk)LAYING CEILING TILES ON A DONN EXPOSED GRID (T38) WITH CAPPINGS OF PREPAINTED ALUMINIUM GRID SUSPENDED FROM CONCRETE SLAB OR TRUSSES WITH METAL HANGERS ALL AS PER MANUFACTURERS REQUIREMENTSCEILIND EDGED WITH A PREPAINTED SHADOWLINECORNICE
TYPE E
A
A
11
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
J
J
K
K
L
L
22
44
55
66
77
88
99
1010
1111
33
1212
1313
1414
A200 -REV A
A200 -REV A
B200 -REV A
B200 -REV A
C201 -REV A
C201 -REV A
D201 -REV A
D201 -REV A
E202 -REV A
E202 -REV A
+2700
+2700
+2700
TYPE D
+2700
+2700
+2700
+2700
+2700
+2700
TYPE D
+2700
TYPE D
+2700+2700
+2700+2700+2700
+2700
+2700
+2700
TYPE D
+2700
+2700
+2700
+2700
+2700
+2700
+2700
+2700
+2700
+2700
+2700 +2700
+2700
+2700
+2700
+2700
3105
4635
2115
3880
5550
3850
2030
4500
1730
4270
3160
3700
1655
44180
46301915451518759860523063902515456020304515
48035
+2
10
0
TY
PE
A
+2400
TYPE B
+2400
TYPE B
+2400
TYPE B
+2400 +2400
+2400
+2400
+2400
TYPE B
+2700
+2805
+2700
TYPE E
TYPE E
TYPE E
TYPE F
+2400
TYPE B
+2400
TYPE B
+2400
TYPE B
TYPE A
TYPE A
TY
PE
A
+3230
TYPE C
+2700
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE DTYPE D
TYPE DTYPE DTYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE D
TYPE DTYPE D TYPE D
TYPE D
TYPE E
TYPE A
TYPE D
+2805
TYPE A
TYPE EClient
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
As indicated
2019/11/03 14:29:34
Designer
GROUND FLOOR CEILING PLAN
LDSD DESIGN PROTOTYPES
400 - REV A
Author
Checker
18/KMS/102
1 : 100
GROUND FLOOR PLAN
J
J
K
K
L
L
1010
1111
Female
van
ity w
ash
han
d b
asin
ur
ur
wc
wc wc
whb
wc wc wc wc
vanity wash hand basin
SDSD
SD
Grab railTRH
TRH TRH TRH TRH
TRH
Male
Paraplegic
1200
70
1200
400
600
600280
50 1200
1200
70
D05
D07
D07
D06
D05
D07 D07 D07 D07
1
2
3
4
5
6
8
7
9
10
11
12
13
600
1570
2200
600
L
L
1010
wc
vanity whb
SD
TRH BABY CHANGING STATION
200 1200
600
590
D06
14
17
16
15
Baby changing
1400
600
L
vanity whb
Ceiling Type A
600 X 600mm skirting tiles to match Floor tiles
850
2100
2400
Male
300
600
200 X 600mm Porcelain wall tiles
GROUND FLOOR PLAN0
1011
vanity wash hand basin
850
2100 2400
Male mirror
soap dispenser
Ceiling Type A
300
600 X 600mm skirting tiles to match Floor tiles
200 X 600mm Porcelain wall tiles
wc
600
10 11
D05
ur urwc
TRH
600
2400
600 X 600mm skirting tiles to match Floor tiles
200 X 600mm Porcelain wall tiles
Male
GROUND FLOOR PLAN0
L
Level 232400
850
2100
2400
D07
ur vanity whb
600 X 600mm skirting tiles to match Floor tiles
600
200 X 600mm Porcelain wall tiles
Ceiling Type A
300
Male
L
wc
TRH
wc
600 X 600mm skirting tiles to match Floor tiles
200 X 600mm Porcelain wall tiles
TRH
W01 W01
Male 2400
600
11
Paraplegic
600 X 600mm skirting tiles to match Floor tiles
600
200 X 600mm Porcelain wall tiles
2400
wc
whb
TRH
Paraplegic WC Type S3.2
Ceiling Type 9.3
Internal wall finish Type 7.5
Soap Dispenser Type 6.5
Paraplegic wash-hand-basin set Type S2.2
Mirror Type 5.1
Floor finish Type 5.3
Side Grab Rail Type K4.9
Rear Grab Rail Type K4.8
mirror
SD
K
Paraplegic
W01 W01
wc
whb
600 X 600mm skirting tiles to match Floor tiles
600
200 X 600mm Porcelain wall tiles
2400
11
Paraplegic
600 X 600mm skirting tiles to match Floor tiles
600
200 X 600mm Porcelain wall tiles
2400
K
600
200 X 600mm Porcelain wall tiles
D06
600 X 600mm skirting tiles to match Floor tiles
Paraplegic
2400
1011
Female
wc
200 X 600mm Porcelain wall tiles
D05
600 X 600mm skirting tiles to match Floor tiles
2400
600
J
wc wc wc wc
W01 W01 W01 W01
TRH
2400
600 X 600mm skirting tiles to match Floor tiles
200 X 600mm Porcelain wall tiles
Female
600
10 11
Ceiling Type A
600 X 600mm skirting tiles to match Floor tiles
vanity whbTRH
wc
Female200 X 600mm Porcelain wall tiles
550
2100
2400
850
300
J
vanity wash hand basin
600
Ceiling Type A
mirror
Soap dispenser
2100
2400
200 X 600mm Porcelain wall tiles
600 X 600mm skirting tiles to match Floor tiles
Female
850
300
L
1100
Baby changing station @ 1100mm heightTRH
600 X 600mm skirting tiles to match Floor tiles
600
200 X 600mm Porcelain wall tiles
Baby changing
2400
Internal wall finish Type 7.5
Floor finish Type 5.3
Approved Baby change unit to specialists and conforming to latest SABS standards.
10
Baby changing station @ 1100mm height
200 X 600mm Porcelain wall tiles
600
600 X 600mm skirting tiles to match Floor tiles
2400
D06
Baby changing
L
Baby changingmirror
vanity whb
200 X 600mm Porcelain wall tiles
600 X 600mm skirting tiles to match Floor tiles
600
2400
300
850
Mirror Type 5.2
Soap Dispenser Type 6.5
Floor finish Type 5.3
Vanity wash-hand-basin Type S2.1
10
W03
wc
TRH
Soap dispenser
vanity whb
600 X 600mm skirting tiles to match Floor tiles
200 X 600mm Porcelain wall tiles
2400
Baby changing
600
300
850
1.1 Stainless Steel single end bowlStainless steel 1000x457mm inset single end bowl with recessed drainage ledge and folded edges. Bowl to be fitted to kitchen cupboard (cupboard elsewhere measured), Grade 304 (18/10) Stainless Steel sink to comply with SABS 906 fitted with: Approved hot and cold Sink mixer- wall type, chrome plated fixed Outlet, adjustable and supplied with suitable assesories in accordance to manufacturer’s specifications. Sink installation height = 900mm AFFL.
SANITARY SPECIFICATIONS:
The following descriptions / specifications are to be read in conjunction with, and work executed in accordance with OW371 SPECIFICATION OF MATERIALS AND METHODS TO BE USED (as published by the Dept of Public Works October 1993 Edition)
4.1 VANITY BASIN:490x310mm Under counter Basin without tap hole but with overflow complete with mounting kit
4.2 PARAPLEGIC BASIN:490mm Ceramic rectangular wall mounted basin with one taphole configuration and concealed brackets, including 12mm C.P. lever action pillar tap with ceramic disks.
4.3 510x405mm basin with tap hole and overflow and pedestal
2.1 Floor standing wash down close coupled dual flush toilet complete with toilet, cistern, push botton acuator, pan, seat, float value and flush valve
2.2 Ceramic Paraplegic semi-close coupled 90° outlet open rim washdown pan and matching 9 litre cistern complete with lid, fitments, and purpose made C.P. right side-flush lever, complete with purpose made thermoset seat and cover plate
2.3 Junior free standing wc floor standing wash down closw coulpeddual flush toilet cistern, push botton acuator, pan, seat, float value and flush valve
7.1 BASIN MIXER:Single lever basin mixer complete withpop-up waste, mounting kit, 1/2" female flexible inlets including alternative flow straighterfor low pressure installation
7.2 SINK MIXER:Wall type sink mixer complete with aerated swivel outlet and concealed connections
7.3 ELBOW ACTION MIXER:Medical pillar mixer with aerated swan neck swivel outlet
2. WC PAN: 4. BASIN AND TAPS1. SINK 5. MIRROR:
6.1 TOILET ROLL HOLDERstainless steel toilet roll holders, size 304x156x140,7mm deep for 2 rolls maximum 108mm diameter with spindle system and cylinder lock with standard key, plugged and screwed to the wall with stainless steel screws.
6.2 WASTE BIN 1stainless steel sanitary towel disposal bins, size 304 x 205 x 134mm deep with capacity of 6 litres, plugged and screwed to the wall with stainless steel screws.
6.3 WASTE BIN 2stainless steel recessed waste disposal bins, size 396 x 270 x 520mm high, capacity of 45 litres and cylinder lock with standard
6.4 PAPER TOWEL DINSPENSERstainless steel paper towel dispenser, size 300 x 270 x 340mm high with a capacity of 300-400 towels and cylinder lock with standard key, plugged and screwed to the wall with stainless steel screws.
6.5 SOAP DISPENSERstainless steel soap dispensers, size 304 x 100 x 134mm deep with a replaceable and refillable 1 litre container, cylinder lock with standard key, plugged and screwed to the wall with stainless steel screws.
6.6 AIR TOWELstainless steel automatic hands free hand dryer, size 284 x 202 x 248mm deep with 2 vandal proof lock screws and key wrench, plugged and screwed to the wall with stainless steel screws, 200 w motor connected to 230/240 volt power supply. with 5 year warranty.
6.7 GRAB RAIL (REAR)32mm diameter stainless steel rear grab rail, in satin finish complete with SS fixing screws and plastic wall plugs. Installed as per manufacturer’s instructions to latest SABS standards.
6.8 GRAB RAIL (SIDE)32mm diameter stainless steel 300x300x300mm right hand side grab rail, in satin finish complete with SS fixing screws and plastic wall plugs. Installed as per manufacturer’s instructions to latest SABS standards.
3.3 WALL HANG URINALBack entry urinal with intedral spreader and trap complete with urinal, outlet seal, inlet bung/seal, metal grating, hunger brackets and integral spreader
6mm Silver float glass copper backed mirrors with beveled edges, holed for and fixed with chromium plated dome capped mirror screws with bubber buffers to plugs in brick walls
5.1 600x1000mm MIRROR5.2 1200x1000mm MIRROR
3. URINAL: 6. OTHERS: 7. TAPS:
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 50
2019/10/16 11:58:58
Designer
WET AREAS
LDSD DESIGN PROTOTYPES
510 - REV 00
Author
Checker
18/KMS/102
1 : 50
PUBLIC ABLUTIONS
1 : 50
BABY CHANGING ROOM
1 : 50
Elevation 11 : 50
Elevation 21 : 50
Elevation 3
1 : 50
Elevation 41 : 50
Elevation 5 1 : 50
Elevation 6
1 : 50
Elevation 71 : 50
Elevation 81 : 50
Elevation 9
1 : 50
Elevation 101 : 50
Elevation 11
1 : 50
Elevation 121 : 50
Elevation 13
1 : 50
Elevation 141 : 50
Elevation 15
1 : 50
Elevation 16 1 : 50
Elevation 17
C
C
D
D
44
55
66
33
ur
ur
wc
wc
wc
wc
wc
whb
Female
Paraplegic
Male
Circulation Area
125
1200
1820
1200
600
600
280
1501800
vanity wash-hand-basin
SD
van
ity w
ash
-han
d-b
asin
SD
TRH
TRH
TRH
TRH
D07
D07
D07
D05
D06
D07D05
18
19
20
21
22
23
24
25
26
27
28
29
30
1500
600
600
1700
CD
Female
600 X 600mm skirting tiles to match Floor tiles
200 X 600mm Porcelain wall tiles Ceiling Type A
300
vanity whbTRH
wc
2100
2400
600
300
850
43
Female
Vanity wash hand basin
soap dispenser
mirror
300
300
600
Ceiling Type A
2100
2400
600 X 600mm skirting tiles to match Floor tiles
200 X 600mm Porcelain wall tiles
850
C D
Female
600
D05
wc
200 X 600mm Porcelain wall tiles
600 X 600mm skirting tiles to match Floor tiles
2400
4 3
Female200 X 600mm Porcelain wall tiles
wc wc wc
TRH TRH TRH
W01 W01 W01
2400
600 X 600mm skirting tiles to match Floor tile
600
D
Paraplegic
600
600 X 600mm skirting tiles to match Floor tile
2400
200 X 600mm Porcelain wall tiles
4
D06
Paraplegic
2400
200 X 600mm Porcelain wall tiles
600 X 600mm skirting tiles to match Floor tile
600
D
Paraplegic
600 X 600mm skirting tiles to match Floor tile
200 X 600mm Porcelain wall tiles
600
Grab rail
whb
wc
2400
4
W01 W01
Paraplegic
600wc
whb
2400
600 X 600mm skirting tiles to match Floor tile
200 X 600mm Porcelain wall tiles
Grab rail
D
2400
Male
wc
TRH
600 X 600mm skirting tiles to match Floor tiles
200 X 600mm Porcelain wall tiles
600
D
Male
D07 D05
2400
ur
200 X 600mm Porcelain wall tiles
600
600 X 600mm skirting tiles to match Floor tiles
5 6
Male
SD
vanity whb
2400
2100
300
600 X 600mm skirting tiles to match Floor tiles
200 X 600mm Porcelain wall tiles
300
850
600
D
Malemirror
300
Ceiling Type A
vanity wash hand basin
soap dispenser
ur
600 X 600mm skirting tiles to match Floor tiles
2100
2400
200 X 600mm Porcelain wall tiles
600
300
850
56
Male
wc
TRH
W01W01
ur ur
600 X 600mm skirting tiles to match Floor tiles
200 X 600mm Porcelain wall tiles
2400
600
K
K
L
L
99
10 m²
Archivefloor tiles
4285
2400
D09
A
D
C
B
KL
Archive
D09
01
01
02
02
04
03
03500
450
450
450
1914
9
Archive
01
01
02
02
02
04
03
03
500
450
450
450
K L
Archive
01
01
03
02
0203
03
02
04
1914
500
450
450
450
9
Archive
GENERAL NOTES:
01 TOPS:16mm THICK CHIPBOARD WITH LEADING EDGES. MELAMINE FINISH TO BOTH SIDES
02 BRACKETS:"SHELVIT" OR ANY OTHER APPROVED SYSTEM 03 ADJUSTABLE WALL
03 FIXING BRACKETS:"SHELVIT" OR ANY OTHER APPROVED SYSTEM, FIXED TO WALL AS PER MANUFACTURER'S SPECIFICATION
04 TOP RAIL:"SHELVIT" OR ANY OTHER APPROVED SYSTEM
NOTE: DESIGN MAY VARY ACCORDING TO DIFFERENT MANUFACTURER'S PRODUCTS
01
500
450
450
450
1914
02
01
02
04
03
03
1.1 Stainless Steel single end bowlStainless steel 1000x457mm inset single end bowl with recessed drainage ledge and folded edges. Bowl to be fitted to kitchen cupboard (cupboard elsewhere measured), Grade 304 (18/10) Stainless Steel sink to comply with SABS 906 fitted with: Approved hot and cold Sink mixer- wall type, chrome plated fixed Outlet, adjustable and supplied with suitable assesories in accordance to manufacturer’s specifications. Sink installation height = 900mm AFFL.
SANITARY SPECIFICATIONS:
The following descriptions / specifications are to be read in conjunction with, and work executed in accordance with OW371 SPECIFICATION OF MATERIALS AND METHODS TO BE USED (as published by the Dept of Public Works October 1993 Edition)
4.1 VANITY BASIN:490x310mm Under counter Basin without tap hole but with overflow complete with mounting kit
4.2 PARAPLEGIC BASIN:490mm Ceramic rectangular wall mounted basin with one taphole configuration and concealed brackets, including 12mm C.P. lever action pillar tap with ceramic disks.
4.3 510x405mm basin with tap hole and overflow and pedestal
2.1 Floor standing wash down close coupled dual flush toilet complete with toilet, cistern, push botton acuator, pan, seat, float value and flush valve
2.2 Ceramic Paraplegic semi-close coupled 90° outlet open rim washdown pan and matching 9 litre cistern complete with lid, fitments, and purpose made C.P. right side-flush lever, complete with purpose made thermoset seat and cover plate
2.3 Junior free standing wc floor standing wash down closw coulpeddual flush toilet cistern, push botton acuator, pan, seat, float value and flush valve
7.1 BASIN MIXER:Single lever basin mixer complete withpop-up waste, mounting kit, 1/2" female flexible inlets including alternative flow straighterfor low pressure installation
7.2 SINK MIXER:Wall type sink mixer complete with aerated swivel outlet and concealed connections
7.3 ELBOW ACTION MIXER:Medical pillar mixer with aerated swan neck swivel outlet
2. WC PAN: 4. BASIN AND TAPS1. SINK 5. MIRROR:
6.1 TOILET ROLL HOLDERstainless steel toilet roll holders, size 304x156x140,7mm deep for 2 rolls maximum 108mm diameter with spindle system and cylinder lock with standard key, plugged and screwed to the wall with stainless steel screws.
6.2 WASTE BIN 1stainless steel sanitary towel disposal bins, size 304 x 205 x 134mm deep with capacity of 6 litres, plugged and screwed to the wall with stainless steel screws.
6.3 WASTE BIN 2stainless steel recessed waste disposal bins, size 396 x 270 x 520mm high, capacity of 45 litres and cylinder lock with standard
6.4 PAPER TOWEL DINSPENSERstainless steel paper towel dispenser, size 300 x 270 x 340mm high with a capacity of 300-400 towels and cylinder lock with standard key, plugged and screwed to the wall with stainless steel screws.
6.5 SOAP DISPENSERstainless steel soap dispensers, size 304 x 100 x 134mm deep with a replaceable and refillable 1 litre container, cylinder lock with standard key, plugged and screwed to the wall with stainless steel screws.
6.6 AIR TOWELstainless steel automatic hands free hand dryer, size 284 x 202 x 248mm deep with 2 vandal proof lock screws and key wrench, plugged and screwed to the wall with stainless steel screws, 200 w motor connected to 230/240 volt power supply. with 5 year warranty.
6.7 GRAB RAIL (REAR)32mm diameter stainless steel rear grab rail, in satin finish complete with SS fixing screws and plastic wall plugs. Installed as per manufacturer’s instructions to latest SABS standards.
6.8 GRAB RAIL (SIDE)32mm diameter stainless steel 300x300x300mm right hand side grab rail, in satin finish complete with SS fixing screws and plastic wall plugs. Installed as per manufacturer’s instructions to latest SABS standards.
3.3 WALL HANG URINALBack entry urinal with intedral spreader and trap complete with urinal, outlet seal, inlet bung/seal, metal grating, hunger brackets and integral spreader
6mm Silver float glass copper backed mirrors with beveled edges, holed for and fixed with chromium plated dome capped mirror screws with bubber buffers to plugs in brick walls
5.1 600x1000mm MIRROR5.2 1200x1000mm MIRROR
3. URINAL: 6. OTHERS: 7. TAPS:
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 50
2019/10/16 11:59:03
Designer
WET AREAS/SHELVING
LDSD DESIGN PROTOTYPES
511 - REV 00
Author
Checker
18/KMS/102
1 : 50
STAFF ABLUTIONS
1 : 50
Elevation 181 : 50
Elevation 191 : 50
Elevation 20
1 : 50
Elevation 211 : 50
Elevation 221 : 50
Elevation 231 : 50
Elevation 24
1 : 50
Elevation 25 1 : 50
Elevation 261 : 50
Elevation 271 : 50
Elevation 281 : 50
Elevation 291 : 50
Elevation 30
1 : 50
ARCHIVE 1 : 50
Elevation A1 : 50
Elevation B1 : 50
Elevation C1 : 50
Elevation D
N
A
A
11
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
J
J
K
K
L
L
22
44
55
66
77
88
99
1010
1111
33
5°
RO
OF
PIT
CH
5°
RO
OF
PIT
CH
5°
RO
OF
PIT
CH
3° ROOF PITCH
3°
RO
OF
PIT
CH
5°
RO
OF
PIT
CH
5°
RO
OF
PIT
CH
3°
RO
OF
PIT
CH
5°
RO
OF
PIT
CH
3°
RO
OF
PIT
CH
1212
1313
1414
A200 -REV A
A200 -REV A
B200 -REV A
B200 -REV A
C201 -REV A
C201 -REV A
D201 -REV A
D201 -REV A
E202 -REV A
E202 -REV A
3105
4635
2115
3880
5550
3850
2030
4500
1730
4270
3160
3700
1655
44180
46301915451518759860523063902515456020304515
48035
5°
RO
OF
PIT
CH
NEW Concealed fix 0.55mm thick and 700mm cover width profile, colour to be confirmed, C.1.S finish with standard backing coat g550 interlocking roof sheeting. AZ100 spelter to both sides fixed to steel purlins as per engineer's specifications using clips, screw fixed to steel purlins secured with No. 10x16mm or 12x22mm wafer head self-tapping screws, all in accordance with manufacturer's recommendations and INSTALLED BY ACCREDITED INSTALLER.
1 : 100
ROOF PLAN
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 100
2019/10/16 11:59:08
Designer
ROOF PLAN
LDSD DESIGN PROTOTYPES
600 -REV 01
Author
Checker
18/KMS/102
A
A
11
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
J
J
K
K
L
L
22
44
55
66
77
88
99
1010
1111
33
1212
1313
1414
A200 -REV A
A200 -REV A
B200 -REV A
B200 -REV A
C201 -REV A
C201 -REV A
D201 -REV A
D201 -REV A
E202 -REV A
E202 -REV A
Multi-purpose HallConsulting Office
Consulting Office
Sick Bay
In-take Screening
Cleaner Store
30 m²
Boardroomfloor carpet
Staff/Kitchen
Consulting Office
Consulting Office
Community Dev.Supr.
Com. Dev.Pract.
Circulation Area
Quiet/Obser.
Group/Interview
Suprv.Social Worker
Female
Male
Male Female
Paraplegic
Store Room
IT/ServerPrint Room
Registry
ArchivePlay Room
Store Room
Security
Consulting Office
Consulting Office
Consulting Office
Consulting Office
Admin Supp.
Head Of Facilities
Meeting Area
Meeting Area
Battery Bank RM
Stationary
Waiting Area
Office Open plan
Circulation Area
Office Open plan
OUTDOOR SEATING
Waiting Area
Reception
Library/Computer Lab
PLA
NT
ER
3105
4635
2115
3880
5550
3850
2030
4500
1730
4270
3160
3700
1655
44180
46301915451518759860523063902515456020304515
48035
Paraplegic
wc
whb
wh
bw
hb
ur
ur
wc
wc wc
whb
wc wc wc wc
whb whb whb
whb whbur
ur
wc
wc
wc
wc
wc
whb
whb
whb
D02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W03
W01 W01 W01 W01 W01 W01 W01 W01
W02 W02 W02 W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W02
W01
W01
W01
W01
W01
W01
W01
W02W02W02W02
W02W02W02
W02
W02
W02
W02
W02
W02
Patio
PatioPatio
Patio
Patio
D02 D03 D04 D04
D03D03D03 D01
D04
D03
D03
D03
D05
D07
D06
D05
D07
D07
D07
D03
D01
D03
D03
D02
D12D09D08
D06
D06
D05D05
D07
D07
D07 D07 D07 D07
D09
D04 D04
D03
D03
D12
D03
D01
D03
AL05
AL10
AL02
AL03
AL01
AL04
AL04
AL08
AL09
AL12
AL07
AL07
AL07
AL07
AL07
AL07
AL07
AL06
AL11
D11
sin
k
Circu
latio
n A
rea
N
Baby changing
5.2 Porcelain Tiles (Interior):600x600x8mm interior Full body matt porcelain floor tiles with 2mm joints on full tile cement bedding.
5.3 Porcelain Tiles (Exterior):600x600x8mm Non-slip Full body exterior porcelain floor tiles with 2mm joints on full tile cement bedding.
TILE LEGEND:
5.4 Porcelain Tiles (Interior):300x600x8mm interior Full body matt porcelain floor tiles with 2mm joints on full tile cement bedding.
550
1200
400 1200
2851200
1200
550
400600
420
1800
600455
4001200
1200
370
4001200
1200
285
4001200
600
200
4001200
4001200
285
600
600445
600645
1200
85
600600
85
1285
1330 540 600 600
580600
400 1200
600505
400 1200
1200120
400 1200
465 1200
380
1200
1200 150
600
150
400 1200
365
1200
1501200
610
300
600
380600
5101800
1200155
600 480
415600
1800
2290
600530
1200
600600
1200290
300
1200
1001800
300
1200
2301200
300
1200
1200
140
535 600
1200
1551200
400 1200
600
330
400 1200
400 1200
1701200
155
1800
400 1800
210
1200
3431200
885
3651200
885
1205
2851200
1200
9701 - REV A
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 100
2019/10/16 11:59:11
Designer
TILE LAYOUT
LDSD DESIGN PROTOTYPES
650 - REV 00
Author
Checker
18/KMS/102
1 : 100
GROUND FLOOR TILE LAYOUT
2700
695 2190
2885
660
2400
1500104810481048104810481048
7785
3060
870 920 920 1560 920 920
6110
660
2400
3060
3060
2710
350
4300
2400
0
1590
2400
300
600
1800
920 920 920
2805
2760
WINDOW DESCRIPTION
WIN
DO
W S
CH
ED
UL
E
SC
AL
E 1
:50
FRAME PARTICULARS
GLAZING PARTICULARS
IRONMONGERY
W02
LOCATION OFFICESMALE / FEMALE /DISABLED ABLUTIONS
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
8.76mm THICK LAMINATED SAFETY GLASS IN ALL PANELS BELOW 900mm HEIGHT FROM FFL AND 6.38mm THICK GLASS IN ALL OTHER PANELS. GLAZING SHALL BE EXECUTED IN STRICT ACCORDANCE WITH THE NBR PART N SABS 10137 SABS 10400, SABS 1263 and AAAMSA SELECTION GUIDE for SAFETY.
ALL OPENABLE PANELS TO COME COMPLETE WITH PEG STAYS, HANDLES & LATCH STAYS
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
OBSCURED 8.76mm THICK LAMINATED SAFETY GLASS IN ALL PANELS BELOW 900mm HEIGHT FROM FFL AND 6.38mm THICK OBSCURED GLASS IN ALL OTHER PANELS. GLAZING SHALL BE EXECUTED IN STRICT ACCORDANCE WITH THE NBR PART N SABS 10137 SABS 10400, SABS 1263 and AAAMSA SELECTION GUIDE for SAFETY.
ALL OPENABLE PANELS TO COME COMPLETE WITH PEG STAYS, HANDLES & LATCH STAYS
1200
1200
2400
900600
900
1500
2400
W01
WINDOW DESCRIPTION
AL
UM
INIU
M S
CH
ED
UL
E
SC
AL
E 1
:50
FRAME PARTICULARS
GLAZING PARTICULARS
IRONMONGERY
AL02
LOCATION MULTI-PURPOSE HALLMAIN ENTRANCE
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.
NONE
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.
ALL OPENABLE PANELS TO COME COMPLETE WITH PEG STAYS, HANDLES & LATCH STAYS
AL01
WINDOW DESCRIPTION
AL
UM
INIU
M S
CH
ED
UL
E
SC
AL
E 1
:50
FRAME PARTICULARS
GLAZING PARTICULARS
IRONMONGERY
AL04
LOCATION RECEPTIONMULTI-PURPOSE HALL
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.
NONE
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.
NONE
AL03 AL05
PASSAGE
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.
NONE
AL06
OPEN PLAN OFFICES
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.
NONE
01
02 01 01
0115 49
01
W03
BABY CHANGE
1200
1200
2400
900
01
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
OBSCURED 8.76mm THICK LAMINATED SAFETY GLASS IN ALL PANELS BELOW 900mm HEIGHT FROM FFL AND 6.38mm THICK OBSCURED GLASS IN ALL OTHER PANELS. GLAZING SHALL BE EXECUTED IN STRICT ACCORDANCE WITH THE NBR PART N SABS 10137 SABS 10400, SABS 1263 and AAAMSA SELECTION GUIDE for SAFETY.
ALL OPENABLE PANELS TO COME COMPLETE WITH PEG STAYS, HANDLES & LATCH STAYS
HINGESDOORS TO BE HUNG ON 100mm ALUMINIUM BUTT HINGES 2 PAIRS PER DOOR
HINGESDOORS TO BE HUNG ON 100mm ALUMINIUM BUTT HINGES 2 PAIRS PER DOORDOORS TO BE HUNG ON 100mm ALUMINIUM BUTT HINGES 2 PAIRS
PER DOOR
ALL OPENABLE PANELS TO COME COMPLETE WITH PEG STAYS, HANDLES & LATCH STAYS
ALL OPENABLE PANELS TO COME COMPLETE WITH PEG STAYS, HANDLES & LATCH STAYS
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 50
2020/02/10 13:08:14
Designer
ALUMINIUM AND WINDOWSCHEDULE
PROPOSED NEW OFFICES FORLIMPOPO DEPT. OF SOCIAL
DEVELOPMENTTSHILWAVHUSIKU SITE
700 - REV B
Author
Checker
18/KMS/102
WINDOW DESCRIPTION
AL
UM
INIU
M S
CH
ED
UL
E
SC
AL
E 1
:50
FRAME PARTICULARS
GLAZING PARTICULARS
IRONMONGERY
AL08
LOCATION WAITING AREACONSULTING OFFICES
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
DOUBLE SAFETY GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THE MANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED IN CCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137
NONE
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
DOUBLE SAFETY GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THE MANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED IN CCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137
NONE
AL07 AL09
STAFF ENTRANCE
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.
NONE
AL10
PLAY ROOM
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
DOUBLE SAFETY GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THE MANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED IN CCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137
NONE
01 01 0107
AL11
PASSAGE
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
DOUBLE SAFETY GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THE ANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED IN ACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137
NONE
01
WINDOW DESCRIPTION
AL
UM
INIU
M S
CH
ED
UL
E
SC
AL
E 1
:50
FRAME PARTICULARS
GLAZING PARTICULARS
IRONMONGERY
LOCATION STAFF/KITCHEN
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.
NONE
AL12
01
AL13
PASSAGE
01
AL14 AL19
QUIET/OBSERVER ROOM
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
DOUBLE SAFETY GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THE ANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED IN ACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137
NONE
0101
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
LOW-E GLASS WITH ATC30 CH SR HPR (CHARCOAL) WINDOW FILM WITH 33% VISIBLE LIGHT TRANSMISSION, 36% TOTAL SOLAR ENERGY-REJECTION, 22% IR ENERGY REJECTION, 29% SELECTION IR REJECTION, >99% UTRAVIO-LET PROTECTION, 63% GLARE REJECTION, 6% VISIBLE LIGHT REFLECTION.
HINGES
NONE NONE
DOORS TO BE HUNG ON 100mm ALUMINIUM BUTT HINGES 2 PAIRS PER DOOR
DOORS TO BE HUNG ON 100mm ALUMINIUM BUTT HINGES 2 PAIRS PER DOOR DOORS TO BE HUNG ON 100mm ALUMINIUM BUTT HINGES 2 PAIRS PER DOOR NONE NONE
900 900 900
2400
2700
2400
750 1500 750
3000
735 1450
2185
2400
2700
876 876 876 876
3505
2400
1595
2400
EQ EQ EQ EQ EQ EQ EQ EQ
5000
8000
2700
10933
2720
2000
2230
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 50
2019/11/03 14:29:35
Designer
ALUMINIUM AND WINDOWSCHEDULE
LDSD DESIGN PROTOTYPES
701 - REV A
Author
Checker
18/KMS/102
WINDOW DESCRIPTION
AL
UM
INIU
M S
CH
ED
UL
E
SC
AL
E 1
:50
FRAME PARTICULARS
GLAZING PARTICULARS
IRONMONGERY
AL16
LOCATION OFFICE OPEN PLANOFFICE OPEN PLAN
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA(AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
ONE WAY VIEW LAMINATED GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THE MANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED IN ACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137
NONE
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
ONE WAY VIEW LAMINATED GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THEMANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED INACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137
NONE
AL15 AL17
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
ONE WAY VIEW LAMINATED GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THEMANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED INACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137
NONE
01 0101
WINDOW DESCRIPTION
AL
UM
INIU
M S
CH
ED
UL
E
SC
AL
E 1
:50
FRAME PARTICULARS
GLAZING PARTICULARS
IRONMONGERY
LOCATION MULTI-PURPOSE HALL
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
ONE WAY VIEW LAMINATED GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THEMANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED INACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137
NONE
AL18
01
MULTI-PURPOSE HALL
RECEPTION AREA
PURPOSE MADE FULLY GLAZED ALUMINIUM WINDOW WITH OPENABLE END PANELS MANUFACTURED ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA) COMPLETE WITH DOOR PANELS WITH FRAME PERIMETER CONTINUOSLY SEALED AGAINST SURROUNDING STRUCTURE WITH NON-PICKABLE EPOXY JOINT SEALANT TO COMPLY WITH SABS 110.
EXTRUDED ALUMINIUM SECTIONS FABRICATED IN ACCORDANCE WITH THE LATEST EDITION OF BS1474 AND ACCORDING TO THE MINIMUM REQUIREMENTS OF THE ASSOCIATION OF ARCHITECTURAL ALUMINIUM MANUFACTURERS OF SOUTH AFRICA (AAAMSA)FINISHED WITH POWDER COATING IN STRICT ACCORDANCE TO SABS 1578 ALL COATING QUALITY PROCEDURES MUST BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR TO ARCHITECT`S APPROVAL
ONE WAY VIEW LAMINATED GLASS, COMPLYING WITH SANS 1263 PART 1, 2 OR 3 WITH NAME OF THEMANUFACTURER PERMANENTLY MARKED ON EACH SHEET VISIBLE AFTER GLAZING, GLAZED INACCORDANCE WITH NBR N SCHEDULE 1 AND SABS 0137
NONE
AL20
03
8048
750
8475
1645
1201
7785
1424
961
5935
442
4300
1275
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 50
2019/11/03 14:29:35
Designer
ALUMINIUM AND WINDOWSCHEDULE
LDSD DESIGN PROTOTYPES
702 - REV A
Author
Checker
18/KMS/102
D01
FFL
DOOR DESCRIPTION
DO
OR
SC
HE
DU
LE
1
:50
FRAME PARTICULARS
IRONMONGERY
ALUMINIUM FRAMES PURPOSE MADE TO DIMENSIONS AS SHOWN. ALL ALUMINIUM SECTIONS TO BE OF EQUAL QUALITY AND MUST COMPLY TO AAAMSA SPECIFICATIONS AND WISPECO MANUFECTURING SPECIFICATIONS
APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.
DOOR FINISH
FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVED SYSTEM LIKE ALRODE COLOUR: COLOUR TO ARCHITECT`S APPROVAL
FRAME FINISH
FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVED SYSTEM LIKE ALRODE COLOUR:
POWDER COATED ALUMINIUM FRAME IN ACCORDANCE TO LATEST SABS STANDARDS. AND QUALITY PROCEDURES TO BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002.
GLAZING DOUBLE CLEAR SAFETY "GSA SMARTGLASS CLEARVUE" GLASS, GLAZED IN ACCORDANCE WITH NBF N SCHEDULE 1 AND SABS 0137.
HINGES 6nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES
D02
D08
D03 D04
LOCATION FIRE ESCAPE
ALUMINIUM FRAMES PURPOSE MADE TO DIMENSIONS AS SHOWN. ALL ALUMINIUM SECTIONS TO BE OF EQUAL QUALITY AND MUST COMPLY TO AAAMSA SPECIFICATIONS AND WISPECO MANUFECTURING SPECIFICATIONS
APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.
FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVED SYSTEM LIKE ALRODE COLOUR:
POWDER COATED ALUMINIUM FRAME IN ACCORDANCE TO LATEST SABS STANDARDS. AND QUALITY PROCEDURES TO BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR:
DOUBLE CLEAR SAFETY "GSA SMARTGLASS CLEARVUE" GLASS, GLAZED IN ACCORDANCE WITH NBF N SCHEDULE 1 AND SABS 0137.
6nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES
STAFF/KITCHEN, MULTIPURPOSE HALL AND BOARDROOM
FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVED SYSTEM LIKE ALRODE COLOUR:
ALUMINIUM FRAMES PURPOSE MADE TO DIMENSIONS AS SHOWN. ALL ALUMINIUM SECTIONS TO BE OF EQUAL QUALITY AND MUST COMPLY TO AAAMSA SPECIFICATIONS AND WISPECO MANUFECTURING SPECIFICATIONS
APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.
FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVED SYSTEM LIKE ALRODE COLOUR: BRONZE
POWDER COATED ALUMINIUM FRAME IN ACCORDANCE TO LATEST SABS STANDARDS. AND QUALITY PROCEDURES TO BE EXECUTED AND RECORDED IN ACCORDANCE WITH SABS ISO 9002. COLOUR: BRONZE
NONE
6nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES
FIRE/ DB CABINET
FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVED SYSTEM LIKE ALRODE COLOUR:
40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.
APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.
WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.
NONE
3nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES
OFFICES, MEETING ROOM, PLAYROOM
STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES
STORES, CLEANER , IT/SERVER, STATIONARY ROOM
40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.
APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.-ACTUAL SIZE OF 300X300 ALUMINIUM DOOR GRILL TO MECHANICAL ENGINEER DETAILS
WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.
NONE
3nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES
STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES
D05
FFL
DOOR DESCRIPTION
DO
OR
SC
HE
DU
LE
1
:50
FRAME PARTICULARS
IRONMONGERY
DOOR FINISH
FRAME FINISH
GLAZING
HINGES
D07D06
D09
LOCATION
MALE / FEMALE ENTRANCES, BABY CHANGING ROOM
TOILET CUBICLESPARAPLEGIC
SABS CATEGORY 2 STRONGROOM DOOR AND FRAME FINISHED WITH ZINC CHROMATE UNDERCOAT READY FOR FINAL COAT COMPLETE WITH CHROME FINISH FURNITURE TO SPECIALISTS. WALL OPENING SIZE TO BE 880x1940mm WITH OVERALL FRAME SIZE OF 1030x2010mm.
AS PER SUPPLIER
WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.
NONE
AS PER SUPPLIER
ARCHIVE
40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.
APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.-ACTUAL SIZE OF 300X300 ALUMINIUM DOOR GRILL TO MECHANICAL ENGINEER DETAILS
WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.
NONE
3nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES
STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES
40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.
APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.
WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.
NONE
3nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES
STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES
40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.
APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.-ACTUAL SIZE OF 300X300 ALUMINIUM DOOR GRILL TO MECHANICAL ENGINEER DETAILS
WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.
NONE
3nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES
STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES
1500
2400
2400
813 813 900
870
19702400
2400
2400
1500
1200
300
1000
1000
vertical grab rail
door handle
kick plate
PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.
PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.
WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.
PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.
PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.
PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.
813
2400
813
03 03
03
RH
LH
12
04
RH
LH
01
01
RH
LH
03
01
RH
LH
07
03
RH
LH
01
04
RH
LH
04
02
750
1500
2520
2250
STAFF/KITCHEN
TYPE
MATERIAL
FINISH
OPENING MECHANISM
FURNITURE
75mm X 1mm POWDER COATED STEEL SLATS, PERFORATED WITH 2mm HOLES
POWDER COATED STEEL SLATS
POWDER COATED - COLOR AS DULUX 30BB 53/012 OR SIMILAR APPROVED
MANUAL OPENING
STANDARD LOCK SYSTEM
01
D10
100kick plate
300
2400
2400
100mm under cut
D11
40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.
APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.
PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.
WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.
NONE
6nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES
STORE ROOM
STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES
1500
01
2400
D12
PLAY ROOM AND SICK ROOM
900
RH
LH
02
00
2400
40mm THICK INTERIOR GRADE FLUSH SEMI-SOLID CORE TIMBER SINGLE DOOR WITH 3mm THICK COMMERCIAL PLY ON BOTH SIDES WITH CONSOLIDATED EDGES FITTED AND COMPLYING WITH SABS 545.
APPROVED IRONMONGERY TO SPECIALISTS AND IN ACCORDANCE WITH LATEST SABS STANDARDS.
WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.
NONE
3nos. STAINLESS STEEL MEDIUM DUTY BUTT HINGES
STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES
PAINTED WITH ONE COAT UNIVERSAL UNDERCOAT AND FINISHED WITH TWO COATS EGGSHELL ENAMEL TO LATEST SABS STANDARD AND ALL IN ACCORDANCE WITH THE FINISHING SCHEDULE.
2400
2400
2400
3230
8675
MULTI-PURPOSE HALL 01
ACOUSTIC PANEL DOOR TO SUPPLIER SPECIFICATION
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 50
2019/11/03 14:29:36
Designer
DOOR SCHEDULE
LDSD DESIGN PROTOTYPES
703 - REV A
Author
Checker
18/KMS/102
1. FLOOR FINISHES 2. SKIRTINGS 3. WALL COVERINGS
1.1
PO
RC
ELA
IN T
ILE
S
1.2
PO
RC
ELA
IN T
ILE
S (
BO
RD
ER
)
1.3
PO
RC
ELA
IN T
ILE
S
1.4
PO
RC
ELA
IN T
ILE
S (
BO
RD
ER
)
1.5
ST
RE
TC
H C
AP
ET
(IN
FIL
L)
1.6
ST
RE
TC
H C
AP
ET
(B
OR
DE
R)
1.7
AC
CE
SS
FLO
OR
1.8
RE
SIL
IEN
T F
LO
OR
CO
VE
RIN
G
1.9
VIN
YL T
ILE
S
1.1
0 U
NT
INT
ED
ST
EE
L T
RO
WE
L G
RA
NO
LIT
H
2.1
PO
RC
ELA
IN T
ILE
S
2.2
140 x
19m
m M
ER
AN
TI
2.3
75x19m
m M
ER
AN
TI
2.4
PO
RC
ELA
IN T
ILE
S
2.5
ST
ON
E M
AT
T P
OR
CE
LA
IN T
ILE
S
2.6
GR
AN
O
3.1
PA
INT
3.2
PA
INT
3.3
PA
INT
3.4
PO
RC
ELA
IN T
ILE
S
3.5
TIM
BE
R C
LA
DD
ING
3.6
TIM
BE
R C
LA
DD
ING
3.7
ST
RE
TC
H C
AR
PE
T
3.5
DA
DO
RA
IL
SECURITY
RECEPTION
WAITING AREA
CIRCULATION 01
MULTI-PURPOSE HALL
STORE ROOM 01
FEMALE ABLUTION 01
MALE ABLUTION 02
PARAPLEGIC 01
BABY CHANGING ROOM
STORE ROOM 02
PLAY ROOM
STORE ROOM 03
STATIONARY
REGISTRY
ARCHIVE
ADMIN SUPPORT
SICK BAY
CONSULTINGOFFICE 01
CONSULTINGOFFICE 02
CONSULTINGOFFICE 03
OFFICE OPEN PLAN
MEETING AREA
WAITING AREA
STAFF/KITCHEN
BOARDROOM
HEAD OF FACILITY
PRINT ROOM
IT/SERVER
IN-TAKE
SCREENING
SUPERVISOR SOCIAL WORKER
CLEANER STORE
PARAPLEGIC 02
FEMALE ABLUTION 04
MALE ABLUTION 03
LIBRARY/COMPUTER LAB
COMMUNITY DEVELOPMENT PRACT.
COMMUNITY DEVELOPMENT SUPERVISOR
GROUP INTERVIEW
QUIET/OBSERVITION
MEETING AREA
CONSULTING OFFICE 05
CONSULTING OFFICE 06
OFFICE OPEN PLAN
CONSULTING OFFICE 07
CONSULTING OFFICE 08
CIRCULATION AREA 02
CIRCULATION AREA 03
GENERAL NOTES: FINISHES
1. FLOOR FINISHES
1.1 PORCELAIN TILE:600x600mm FULL BODY MATT NON-SLIP PORCELAIN TILES LAID TO TILE PATTERN, ON A SMOOTH, EVEN ANDDUST FREE SURFACEBED / SLAB WITH APPROVEDTILE ADJESIVENAME:CODE: SUPPLIER:
1.2 PORCELAIN TILE BORDER:300x300mm FULL BODY POLISHED PORCELAIN FLOOR TILES LAID ACC. TO TILE PATTERN, ON A SMOOTH, EVEN AND DUST FREE SURFACEBED / SLAB WITH APPROVED TILES ADHESIVENAME: CODE: SUPPLIER:
1.3 PORCELAIN TILES:600x600mm FULL BODY NON-SLIP STONE MATT PORCELAIN FLOOR TILES LAID ON A SMOOTH, EVEN AND DUST FREE SURFACE BED / SLAB WITH TILE JOINTS AT 5m c/c WITH APPROVED TILE ADHESIVE : NAME: CODE: SUPPLIER:
1.4 PORCELAIN TILE BORDER:300x300mm FULL BODY NON-SLIP STONE MATT PORCELAIN FLOOR TILES LAID ON A SMOOTH, EVEN AND DUST FREE SURFACE BED / SLAB WITH TILE JOINTS AT 5m c/c WITH APPROVED TILE ADHESIVE:NAME: CODE: SUPPLIER:
1.5 STRETCH CARPET (INFILL)STRETCH CARPET BORDER LAID ON A SMOOTH ON CLEAN AND DUST FREE SURFACERANGE: WESTMINISTERNAME: IRON STONEMANUFACTURER: NEXUS - BELGOTEX
1.6 STRETCH CARPET (BORDER)500mm WIDE STRETCH CARPET BORDER LAID ON A SMOOTH ON CLEAN AND DUST FREE SURFACERANGE: WESTMINISTERNAME: BLACK CITYMANUFACTURER: NEXUS - BELGOTEX
1.7 ACCESS FLOOR BY SPECIALIST
1.8 RESILIENT FLOOR COVERINGLINOLIUM HOMOGENEOUS FLOOR SHEETING 2,5mm THICK SINGLE LAYER ON JUTE BACKING ROLLS WITH WELDED JOINTS FIXED TO WELL FINISHED AND PROPERLY PREPARED SURFACE WITH SPECIAL ADHESIVE AS PER MANUFACTURER'S SPECIFICATION
1.9 VINYL TILES300x300x4mm THICK VINYL TILES LAID ACCORDING TOMANUFACTURER'S SPECIFICATION ON A SMOOTH, CLEANAND DUST-FREE SURFACERANGE: COLOUR: CODE: MANUFACTURER:
1.10 UNTINTED GRANOLITHUNTINTED GRANOLITH FINISH WITH SMOOTHTROWELLED FINISH
2. SKIRTINGS
2.1 PORCELAIN TILES:150x600mm PORCELAIN TILES LAID ACCORDING TO TILE PATTERN, JOINTS CONTINUOUS IN BOTH DIRECTIONS WITH ALUMINIUM EDGE STRIPSNAME: CODE:SUPPLIER:
2.2 MERANTI SKIRTING:140x19mm MOLDED MERANTI NAILED TO WALL AT 400mm C/C MAX. WITH 50mm STEEL NAILS. NAIL HEADS SUNK,HOLES FILLED AND FINISHED FLUSH, 19mm SA PINE1/4 ROUND NAILED TO SKIRTING WITH 25mm HEADLESSNAILS AT 300mm C/C MAX. NAIL HEADS SUNK, HOLESFILLED AND FINISHED FLUSH.
2.4 PORCELAIN TILES:600x600mm PORCELAIN TILES LAID ACCORDINGTO TILE PATTERN, JOINTS CONTINUOUS IN BOTH DIRECTIONS WITH ALUMINIUM EDGE STRIPNAME: CODE:SUPPLIER:
2.5 PORCELAIN TILES:150x600mm PORCELAIN TILES LAID ACCORDINGTO TILE PATTERN, JOINTS CONTINUOUS IN BOTH DIRECTIONS WITH ALUMINIUM EDGE STRIP NAME: CODE:SUPPLIER:
2.6 GRANO SKIRTING150mm HIGH MONOLITHIC UPWARD SLOPING CONCAVE GRANO SKIRTING
2.3 MERANTI SKIRTING:75x19mm MERANTI NAILED TO WALL AT 400mm C/CMAX. WITH 50mm STEEL NAILS. NAIL HEADS SUNK,HOLES FILLED AND FINISHED FLUSH, 19mm SA PINE1/4 ROUND NAILED TO SKIRTING WITH 25mm HEADLESSNAILS AT 300mm C/C MAX. NAIL HEADS SUNK, HOLESFILLED AND FINISHED FLUSH.
3. WALL COVERINGS
3.1 PAINT FINISH: MATT12mm SAND / CEMENT PLASTER WITH SMOOTH TROWELFINISH. TO RECEIVE PAINT FINISH 1 x HIGH HIDING POWER UNDERCOAT: SABS SPECIFICATION 681, GRADE 13 x EMULSION PAINT (INTERIOR): SABS SPECIFICATION 1586, GRADE 1COLOUR RANGE: CODE:
3.2 PAINT FINISH: MATT 12mm SAND / CEMENT PLASTER WITH SMOOTH TROWELFINISH. TO RECEIVE PAINT FINISH 1 x UTILITY GRADE UNDERCOAT: SABS SPECIFICATION 681, GRADE 23 x EMULSION PAINT (INTERIOR): SABS SPECIFICATION 1586, GRADE 1COLOUR RANGE: CODE:
3.3 PAINT FINISH: MATT12mm SAND / CEMENT PLASTER WITH TRUE TROWELFINISH. TO RECEIVE PAINT FINISH 1 x HIGH HIDING POWER UNDERCOAT: SABS SPECIFICATION 681, GRADE 13 x EMULSION PAINT (EXTERIOR): SABS SPECIFICATION 1586, GRADE 1COLOUR RANGE: CODE:
3.4 PORCELAIN TILE:300x600mm HALF BODY MATT NON-SLIP PORCELAIN TILES LAID TO TILE PATTERN, ON A SMOOTH, EVEN AND DUST FREE SURFACE WITH APPROVED TILE ADHESIVE WITH CORNER ALUMINIUM EDGE STRIPS AND HORIZONTALALUMINIUM STRIPS AT SPECIFIED INTERVALS NAME:CODE:VARYING SUPPLIER:
3.5 NON ACOUSTICAL TIMBER CLADDING TO DETAILS
3.6 ACOUSTICAL TIMBER CLADDING TO DETAILS
3.7 STRETCH CARPETSTRETCH CARPET BORDER LAID ON A SMOOTH ON CLEAN AND DUST FREE SURFACE FROM FFL. TO DADO RAILRANGE: NAME: MANUFACTURER:
3.8 DADO RAIL:PROFILED TIMBER RAIL ACCORDING TO PROFILE, FIXEDTO WALL AT 1m HIGH ON POSITIONS AS INDICATED ONDETAIL PLANS
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
1 : 50
2019/10/16 11:59:15
Designer
FINISHING SCHEDULE
LDSD DESIGN PROTOTYPES
800 - REV A
Author
Checker
18/KMS/102
A
A
B
B
C
C
2 2
3 3
8 m²
Officep.tiles
2 m²
WCp.tiles
6025
205
230 2600 230 1430
6230 3060 1430
460
3190
1700
715
4360
1615
6230 2830 2160 2230
IN
OUT
D1
D1
A
200 - REV 02
A
200 - REV 02
AL2
AL1
W1
Boom gates to suppliers
specification
1 1
4 4
6690
AL1
D1
D
D
E
E
10720
230
900
230
3000
230
4590
230
95
5700
205
230 2600 230 1200 230
1700
2890
4590
Pedestrian Gate
hwbwc
worktop
Refer to fixed joinery drawings for details
Boom gates to suppliers
specification
B
200 - REV 02
B
200 - REV 02
1700
3190
460
1700
A
A
B
B
C
C
2 2
3 3
6230 2830 2160 2230
715
4360
1615
A
200 - REV 02
A
200 - REV 02
1 1
4 4
6690
D
D
E
E
B
200 - REV 02
B
200 - REV 02
Roof Pitch 7.5°
NEW Concealed fix 0.55mm thick and 700mm cover width profile, colour to be confirmed, C.1.S finish with standard backing coat g550 interlocking roof sheeting. AZ100 spelter to both sides fixed to steel purlins as per engineer's specifications using clips, screw fixed to steel purlins secured with No. 10x16mm or 12x22mm wafer head self-tapping screws, all in accordance with manufacturer's recommendations and INSTALLED BY ACCREDITED INSTALLER.
13450
GROUND FLOOR LEVEL0
WALLPLATE2805
Window Level2125
2 31 4
2125
2805
GROUND FLOOR LEVEL0
WALLPLATE2805
Window Level2125
A B C
680
2125
D E
2400
GROUND FLOOR LEVEL0
WALLPLATE2805
Window Level2125
ABC
2125
680
DE
2400
2400
2805
GROUND FLOOR LEVEL0
WALLPLATE2805
Window Level2125
23
2125
680
14
D1
Lotus Amoretti Michaelangelo Collection 40mm thick Horizontal 813 meranti door with horizontal slats, size 813 x 2032mm high. Sand down timber surface to a fine smooth finish and apply two coats Lotus Sheen quality timber sealant prior to installation, all in accordance with themanufacturer's recommendations.
3
Plascon Cashmere to exterior new wood (NW 525).Surface to be dry, sound and clean. Wash knots and resinous areas with Lacquer Thinners (ILS 1) and coat with Woodcare Knot Seal (PK 2) and apply one coat of Plascon Woodcare Pretreatment (WWP 1), overcoated within 48 hours with a moisture content, measured with a Doser Hygrometer (or equivalent), of BD 2 scale (A1-A5) < 14% or less. Prime with one coat of Wood Primer (UC 2) with an overcoating time of 16 hours and finish with two coats of Cashmere (CAS) with 2 hours drying time between coats, for a maintenance cycle of 7 years in a C1 - inland environment.
STANDARD 1.2mm MILD STEEL DOUBLE REBATE PRESSED METAL FRAME COMPLYING WITH SABS 1129 COMPLETE WITH LUGS AND FIXTURES
WASHABLE ENAMEL PAINT FINISH COMPLYING WITH SABS 723 FOR PRIMER, SABS681 FOR UNDERCOAT AND SABS 630 TYPE 2 FOR FINISH COAT.
None
QUANTITY
DOOR LEAF
DOOR FINISH
FRAME TYPE
FRAME FINISH
GLAZING
DO
OR
SC
HE
DU
LE
1
:50
2115
813
W1 AL2 AL1
QUANTITY
WIN
DO
W
SC
HE
DU
LE
1:5
01 01 02
FRAME TYPE
GLAZING
ALUMINIUM FRAMES PURPOSE MADE TO DIMENSIONS AS SHOWN. ALL ALUMINIUM SECTIONS TO BE OF EQUAL QUALITY AND MUST COMPLY TO AAAMSA SPECIFICATIONS AND WISPECO MANUFECTURING SPECIFICATIONS
DOUBLE CLEAR SAFETY "GSA SmartGlass ClearVue" glass, glazed in accordance with NBR N schedule 1 and SABS 0137.
FRAME FINISH
FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVEDSYSTEM LIKE ALRODE COLOUR: BRONZE
ALUMINIUM FRAMES PURPOSE MADE TO DIMENSIONS AS SHOWN. ALL ALUMINIUM SECTIONS TO BE OF EQUAL QUALITY AND MUST COMPLY TO AAAMSA SPECIFICATIONS AND WISPECO MANUFECTURING SPECIFICATIONS
DOUBLE CLEAR SAFETY "GSA SmartGlass ClearVue" glass, glazed in accordance with NBR N schedule 1 and SABS 0137.
FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVEDSYSTEM LIKE ALRODE COLOUR: BRONZE
ALUMINIUM FRAMES PURPOSE MADE TO DIMENSIONS AS SHOWN. ALL ALUMINIUM SECTIONS TO BE OF EQUAL QUALITY AND MUST COMPLY TO AAAMSA SPECIFICATIONS AND WISPECO MANUFECTURING SPECIFICATIONS
DOUBLE CLEAR SAFETY "GSA SmartGlass ClearVue" glass, glazed in accordance with NBR N schedule 1 and SABS 0137.
FINISH TO FRAMES POWDER COATED MIN 25 MIKRON MUST BE APPLIED ACCORDING TO A PATENT AND SABS APPROVEDSYSTEM LIKE ALRODE COLOUR: BRONZE
900
600
2780
1560
1200
1560
SCALE 1 : 100
GROUND FLOOR LEVEL
Client
service
cad file name
REVIT 2016
designed
drawing title
drawing number
ref. no
scale drawn
checkeddate
type number
NO DATE AMENDMENT
82 Grimbeek Street, Founa Park, Polokwane, 0699Tel: (015) 590 0995 Cell: 072 661 2523
Email: admin@kmsarch.co.zaWebsite: www.kmsarch.co.za
POLOKWANE
Implementing Agent
ITE
MN
AM
EP
OS
ITIO
ND
AT
ES
IGN
AT
UR
E
1.
2.
3.
4.
DEPARTMENT APPROVAL
As indicated
2020/02/17 15:51:42
Designer
FLOOR PLAN, ROOF PLAN ANDELEVATIONS
LDSD DESIGN PROTOTYPES
100 - REV 02
Author
Checker
00000
notes in respect of sa standard code of practice for the application of the national building regulations, sans 10400
part d public safety· all balustrading to comply with dd2
part m stairways· dimensions of stairways to be in compliance with mm2· all balustrading to comply with mm3
part n glazing· all glazing to comply with sabs code n
part o lighting & ventilation· all areas to be artificially lit in compliance with oo6, offices & other habitable rooms min 35o lux, toilets min 160 lux· all designed by electrical consultant and in accordance with ohs act· natural ventilation of 5% of floor area· natural smoke ventilation of 1.5% of floor area· if required toilets to be mechanically ventilated by extraction to external at rate of 20l/s/fitment· all air conditioning will be designed by a professional engineer· and will be in accordance with nbs regulations
part p drainage· all joints to comply with pp2 & pp6· all sanitary fixtures to be in accordance with pp3 - pp5· all drainage to comply with the relevant portions of pp15, depending on type of system utilized
· all discharge & ventilating pipes to be installed in compliance with pp20· drains to be accessible in accordance with pp21· all sanitary fixtures to have traps in accordance with pp22· gully to comply with requirements of pp23· all drains to be laid in accordance with with pp24· all wet services are to be designed by a professional and registered engineer
part r stormwater disposal· sizes of roof valleys & gutters to comply with rr3· drains to be accessible in accordance with rr4· the stormwater disposal system shall be designed by a professional engineer
part s facilities for disabled persons· ramps to be provided in accordance with ss2· toilet facilities to be provided in accordance with ss5· parking bays to be provided in compliance with ss8· signage to comply with ss9part s facilities for disabled persons· ramps to be provided in accordance with ss2· toilet facilities to be provided in accordance with ss5· parking bays to be provided in compliance with ss8· signage to comply with ss9
part t fire protection· occupancy to comply with tt3· all materials to comply with tt5· all structural elements & components to comply with tt7· fire resistance of division seperating elements to comply with tt6· internal partitions and walls to comply with tt9· all openings to be protected in compliance with tt10· roof assemblies & coverings to comply with tt12· provision escape routes to comply with tt16· all exit doors to comply with tt17· all feeder & emergency routes to comply with tt18 & tt19· dimensions of components of escape routes to comply with tt20· width of escape routes to comply with tt21· reception area to comply with tt26· all access doors to emergency routes to be sabs class b 120 min rated doors fitted with self closers in compliance with tt10.4 & locks in compliance with tt19.9· all fire services are to be designed by a professional and registered fire consultant· all ceilings to comply with tt13· all floor coverings to comply with tt14· all wall finishes to comply with tt15· feeder routes to be provided in accordance with tt18· when partition layouts are designed - to be submitted under separate application· locks to escape & access doors to be fitted with knob/cylinder locks in compliance with tt19.9· ventilation to stairs to comply with tt24· all openings in floors to comply with tt26· signage to be provided in accordance with tt29, tt32, tt55,4 & tt55,5· emergency routes to be lit in accordance with tt30, designed by professional engineer & certificate issued on completion· water reticulation for fire fighting purposes to be comply with tt33· fire hose reels to be provided in accordance with tt34· hydrants to be provided in accordance with tt35· portable fire extinguishers to be provided in accordance with tt37 to the satisfaction of the chief fire officer
· any inaccessible concealed space with a max dimension of more than 5m to be fire stopped in accordance with tt39· service pipes, conduits & sleeves to comply with tt41· provision to be made for smoke ventilation and detection system designed in accordance with tt42, designed by professional engineer & certificate issued on completio· air conditioning system to be designed by professional engineer to comply with tt43 & certificate issued on completion· stairway to comply with tt23.6· parking to comply with tt51· no smoking signs to comply with tt44· sprinkler system to be designed by professional· engineer & certificate issued on completion
part u refuse disposal· refuse area to be constructed & provided with hose, bibtap & sump
water supply notes· existing municipal water conections to be used.· water pressure to be tested at existing fhr to determine if watertanks are required for fire hose reels.· all water supply pipes above ground with a diameter of 38mm or less are to be copper class 460/0. all pipes in chases to be spiral wrapped with kraftex building paper.· no pipes are to be installed below surface beds.· pipes in ground to be in upvc or hope installed to manufactures and sabs specification. all galvanised pipes used in ground shall be denso-protected in strict accordance with manufactures specification.
SCALE 1 : 100
ROOF PLAN
1 : 100EAST ELEVATION
1 : 100NORTH ELEVATION
1 : 100SOUTH ELEVATION 1 : 100
WEST ELEVATION
230
4 500
230
345 230 4 000 230
4 960
230
4 500
230
230
100
1 700
2 700
230
1 645
2 199
1 550
65
0
2 720
110
220
220
110
345 4 460
4 805
4 960
500 500 500 500 500 500
345 230 4 000 230
345 4 460
4 805
AA
concrete slab laid to a fall, details to eng's design
50mm concrete coping on bricks
4 brick course parapet wall
3
DIE
SE
L C
OU
PLE
D
PU
MP
A
SS
EM
BLY
ELE
CT
RIC
M
OT
OR
CO
UP
LE
D P
UM
P
AS
SE
MB
LY
PLAN
FRONT VIEW
3
DIESEL COUPLED PUMP
ASSEMBLY
ELECTRIC MOTOR
COUPLED PUMP
ASSEMBLY
ELECTRIC PUMP
CONTROLLER
DIESEL PUMP
CONTROLLER
JOCKEY PUMP
CONTROLLER
FUEL SUPPLY
LINE
PE
RF
OR
AT
ED
W
AL
L
DOOR GRILLE
DOOR GRILLE
50L Diesel
Fuel Tank
Ø110mm
Ø110mm
Ø 32mm
Ø65mm
Ø65mm
Ø110mm
Butterfly Valve
Check Valve
Ø110mm
Strainer
Butterfly Valve
Check Valve
Ø110mm Pipe
Connected to the
Lowest Point on
the Sectional Steel
Tank
ELECTRIC
DOMESTIC
WATER PUMP
Ø32mm Pipe
Connected to the
Upper Point on
the Sectional Steel
Tank
Ø32mm
Strainer
Butterfly Valve
Check Valve
Ø32mm
Ø32mm
AecbDbPipe (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipe (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipe (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipe (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipe (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipe (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70) AecbDbPipeFitting (AecbPipeBase70)
AecbDbMvPart (AecbBldSrv70)
AecbDbPipe (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbMvPart (AecbBldSrv70)
AecbDbMvPart (AecbBldSrv70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipe (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbMvPart (AecbBldSrv70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipe (AecbPipeBase70)
AecbDbPipe (AecbPipeBase70)
AecbDbMvPart (AecbBldSrv70)
AecbDbMvPart (AecbBldSrv70)
AecbDbPipe (AecbPipeBase70)
AecbDbPipe (AecbPipeBase70)
AecbDbPipe (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
AecbDbPipeFitting (AecbPipeBase70)
FLOOR PLAN
scale 1:50
Top of Concrete (+0.000)
Lintel Level (+2.135)
NGL
Pump details ref to
Mech Eng's specs
SECTION A-A
scale 1:50
Top of Concrete (+0.000)
Lintel Level (+2.135)
NGL
FRONT ELEVATION
scale 1:50
RIGHT SIDE ELEVATION
scale 1:50
Top of Concrete (+0.000)
Lintel Level (+2.135)
NGL
Roan Satin facebrick
BACK ELEVATION
scale 1:50
Top of Concrete (+0.000)
Lintel Level (+2.135)
NGL
LEFT SIDE ELEVATION
scale 1:50
Wall Height (+3.120)
Vents Base (+1.000)
Wall Height (+3.120)
Top of Concrete (+0.000)
Lintel Level (+2.135)
NGL
Roan Satin facebrick
Wall Height (+3.120)
Wall Height (+3.120)
Roan Satin facebrick
Roan Satin facebrick
Maize Travertine Maize Travertine
Maize Travertine Maize Travertine
Maize Travertine Maize Travertine
Maize Travertine Maize Travertine
Roan Satin facebrick
Roan Satin facebrick
Roan Satin facebrick
Wall Height (+3.120)
Roan Satin facebrick
Maize Travertine Maize Travertine
Maize Travertine Maize Travertine
Vents Base (+1.000)
Vents Base (+1.000)
Roan Satin facebrick
Roan Satin facebrick
Maize TravertineMaize Travertine
Slab Level (+2.720)
Slab Level (+2.720)
Slab Level (+2.720)
Slab Level (+2.720)
Slab Level (+2.720)
Top of Concrete (+0.000)
Lintel Level (+2.135)
NGL
Wall Height (+3.120)
Slab Level (+2.720)
Vumesa (Pty) Ltd
SIGNATURE DATE
1B Deodant Building
10 Pyne Street,
PINETOWN,
3610
Tell : 031 701 1038
Fax : 03 701 0963
DESIGNED
DRAWN
CHECKED
APPROVED
SCALE
PUMP ROOM & GENERATOR PLINTH
DRAWING REVISIONS
REV DATE DRAWN CHECKED DESCRIPTION
NOTE: Only signed drawing are considered
as issued drawings.