CONTENTS
1. General Discription of Air Conditioner ...................................................................2
2. Refrigerant Cycle....................................................................................................9
3. Installation .............................................................................................................11
4. Window Type Room Air Conditioner....................................................................34
5. Split Type Room Air Conditioner..........................................................................48
6. Packaged Type Air Conditioner............................................................................90
7. Control And Electrionics Part .............................................................................100
8. Method Of Main quality Service.........................................................................123
9. The Others And References..............................................................................143
Contents
8/17/2019 AirCon Training Manual
2/175
2
1. GENERAL DISCRIPTION OF AIR CONDITIONER
1. TYPE OF AIR CONDITIONER
1-1. Classification according to funciton
Cooling
Cooling + Heating (Electric heater)
Cooling + Heatig (Heat pump)
1-2. Classification according to installation type
Window Window
Skinny
PTAC
Split SplitFloor
Multi
Ceiling
Duct
Convertible
Multi
8/17/2019 AirCon Training Manual
3/175
3
2. EXPLANATION OF TERMINOLOGY
1)Air Conditioning:
Keeping room air in an optimum condition, depending on the use or purpose. (Cooling, heating, humidity regulatiog,air cleaning, etc.)
2) Cooling (Heating) capacity:
Calorie which is able to be released (or added) per a unit time in room. It is expressed in Kcal/h, BTU/h, W or RT
3)Humidity
(1) Absolute humidity: The amount of vapor contained in the air. Generally it is equal to the amount of vapor by g unitcontained in 1m3 air, and is expressed in g/m3.
(2) Relative humidity: The ratio between the amount of vapor contained in the air and the maximum amount (theamout of saturated vapor) of vapor capable of containing at that temperature in %.
*Relative humidity= Actual vapor pressure/Saturated vapor pressure x 100= Actual vapor pressure of dew point temperature/saturated vapor pressure of dry-dulb temp.
x 100(3) Dew point temperature: The surface temperature which starts dewing on the surface when it is cooled in the air.
4) Heat
(1) Latent heat and sensible heat:Heat which causes a change in the state of a substance, with its temperature being constant, is called latent heatwhereas heat which changes the temperature of a substance is called sensible heat. Latent heat is expressed interms of calories needed to cause a change of state of a substance per 1 kg. The following equation shows that QKcal is needed to change state of a substance weight G Kg when the latent heat is L Kcal/kg. (Q=GL)
(2) Thermal flow1 Radiation : A phenomenon which termal energy as an electro-magnetic wave is transmitted directly from a
thermal source.2 Conduction : A phenomenon which transmits from high to low temperature when there is a temperature
difference partially in a substance.3 Convection : When the temperature of a fluid like gas or liquid changes by heat, the high temperature part
expands and thus the density drops to cause to be light whereas the low themperature part is tobe heavy. It means a phenomenon that heat is transmitted together when floating happens by the
weight difference of air.
Three states of a substance
8/17/2019 AirCon Training Manual
4/175
4
5) Quantity of heat
(1) Kcal: Adding or releasing heat to or from a substance changes its temperature. This change of temperature is inproportion the heat added or released This heat is called calorie which is expressed in Kcal or cal. 1 Kcal isequal to the amount of heat required to raise the 1˚C Temperature of 1kg water 4˚C.
(2) BTU: 1 BTU is equal to the amount of heat required to raise the 1˚F temperature of 1 lb water.•1 Kcal=3.968 BTU, 1 BTU=0.252 Kcal
6) Refrigerating Ton (RT):• 1 RT is equal to the capacity which makes 1 Ton water 0˚C into ice 0˚C in 24 hours. It is expressed in calorie
required to freeze water 1 Ton water 32˚F(200 lb) into ice 32˚F, and when using the solidification latent heat ofwater, 1RT is as follows
• 1 RT= 144BTU/lb x 200 lb/24hr = 12,000 BTU/lb = 3,024 Kcal/h = 3.517 KW
7)Pressure:
Pressure p is the normal (perpendicular) force exerted by a fluid per unit area against which the force is exerted.Absolute pressure is the measure of pressure above zero; gauge pressure is measured above existing atmosphericpressure. the unit used for pressure is newtons per square meter (N/m 2), also called a pascal (Pa). The newton is aunit of force. Standard atmospheric pressure is 101,325 Pa=101.3 kPa.
8) Specific heat:
The specific heat of a substance is the quantity of energy required to raise the temperature of a unit mass by 1 K.
9) Horse Power(Hp)
• 1 Hp = 0.75 KW = 645 Kcal/h, 1W = 086 Kcal/h
10) Conversion of unit
(1) Temperature conversion (˚C ˚F)• ˚F = 9/5˚C + 32, ˚C = 5/9(˚F-32)
(2) Area or volume conversion
• 1m
2
= 10.764 ft
2
, 1m
3
= 35.3165ft
3
(3) Weight conversion• 1Kg = 2.2 lb, 1 lb = 0.45 Kg
(4) Unit conversion table
Classification
1BTU/h
1Kcal/h
1W
1KJ
1Hp
1RT
BUT/h
1
3.968
3.413
0.948
2559
12000
Kcal/h
0.252
1
0.86
0.239
645
3024
W
0.293
1.163
1
0.278
750
3516
KJ
1.055
4.186
3.601
1
2700
12660
Hp
0.00039
0.00155
0.00133
0.00037
1
4.68
RT
0.000083
0.000329
0.000283
0.000079
0.212
1
8/17/2019 AirCon Training Manual
5/175
5
11) Compressor:
Absorb and compress the low pressure gasified refrigerant in evaporator and let it flow into condenser. At this time,the low pressure is to be kept in evaporator and the refrigerant gas flows into condenser as high pressure condition.The most economical condition of compressor for an proper operating is when the refrigerant gas absorbed intocompressor is in dry-saturated condition. The overly-heated suction gas may cause the mechanical ability ocompressor to be reduced and the cylinder clearance of compressor to be re-expanded, and as a result, therefrigerant may be used without its refrigerating effect. The types of compressor is Recipro. type, Rotary type, Scroll
type, Screw type, etc. and consists of cylinder, piston, vane, shaft, bearing, case and accumulator for structurereason.
12) Condenser:
The high temperature/high pressure refrigerant gas compressed by compressor is sucked into condenser andliquified by cooling. The condenser is cooled by the forced-convection of fan. The calorie emitted from condenser isequal to the sum of the heat absorbed in evaporator and the calorie used for compressor operationg.
13) Evaporator:
Absorb the heat from room air by forced-convectionThe liquid refrigerant in evaporator is evaporated by absorbing heat from room air and flowed into compressor as a
gasified state. The evaporating temperature of refrigerant is decided by pressure, which is decided by thetemperature of suction air and the wind flow, and the pressure in evaporator is normally 5Kg/cm2G and theevaporating temperature is 5~8˚C
14) Capillary (Expansion Valve):
Regulate the refrigerant flow into evaporator get, lower the pressure of refrigerant, and lead it into a liquid of lowtemperature and low pressure. The type of capillary is generally a thin and long copper tube of 0.6~2.0mm2 innerdiameter and 1~2m long. The resistance of tube causes to turn into a liquid of low pressure and low temperature.
15) Dryer:
Any moisture in refrigerating cycle may cause the compressor motor to be damaged or turn into an ice state it selfin the middle of cycle, which blocks the flow of refrigerant. Dryer is installed in a cycle for the purpose of removing
such moisture.There are two types of dryer; a liquid line dryer which is connected serially to the condenser outlet and a suction linedryer which is connected serially to the suction line, with a desiccative in dryer.The dryer is designed for uni-directional flowing of the refrigerant.
16) Strainer:
Strainer serves to remove foreign substances from refrigerant by a metal net pelt of fine grid or a glass wool beinginserted into metal vessel and refrigerant being passed through between the interval. The mounted position isbetween condenser and capillary expansion valve.
17) Service valve:
Service valve is used for vacuum working and refrigerant filling. Front seat is called a state which cap is opened andvalve is completely rotated clockwise and refrigerant stops flowing in that condition, whereas back seat is called astate which valve is totated completely counter-clockwise and refrigerant flows. In case of pressure measurementsor vacuum work form service valve, the back seat condition is changed into some fornt seat condition. Product isreleased in front seat condition, so the back seat by brake-in is not needed.
18) Motor:
Generates a rotating force by electric power and supply the driving force to fan and blower in both indoor andoutdoor of air conditioner.
8/17/2019 AirCon Training Manual
6/175
6
19) Fan:
Generates forced air flow. The forced air passes throngh heat-exchanger and blow out the heat (or give the heat onthe contrary) from heat-exchanger.A Fan can be classified by axial fan and radial fan. Generally we call axial fan (mostly propellar fan) as (Fan).
20) Blower (Cross Flow Fan: C.F.F):
A kind of Fan. It also generates forced air flow and air flows cross over axis of FanBlower is placed indoor unit, so a small size, high wind flow and low noise type is used.
21) Thermostat:
Sense the temperature of air or heat exchangers and controlls automatically room temperature by switchingcompressor on/off depending on temperature. Thermostat is used for a mechanical type model and thermistor for amicom type control method.
22) Capacitor:
Get shift the phase of input electricity for compressor or fan motor, which leads starting direction and torque to thecompressor motor or fan motor for aircon and make the operating efficiency better during operation.
23) Over load protector (O.L.P):A protective device of automatic retrip type which is placed in the compressor and trip(cut) off the power ofcompressor moto against the overheat and overcurrent of compressor.At this time, compressor stopps operating by power off and only fan is on work. Generally the trip temperature isaround 120°C and the return thmperature is around 90°C.
24) High pressure switch(H.P.S/W):
A protective device of automatic return type which protects compressor and the discharge pipes from overload bysensing the discharge pressure of compressor, working at an abnormal high temperature, and shutting off theelectric circuit. Generally the working pressure is around 28kg/cm2G and the return pressure is 23 kg/cm2G.
25) Accumulator:A kind of liquid refrigerant separator which prevents the liquid refrigerant getting into compressor and is installed inthe suction inlet of compressor.
26) Reversing valve (4 way valve):
Convert the flow of refrigerant upon cooling/heating switch-over, electrically power on when heating and off whencooling, be installed in outdoor, and have four connecting valves as shown in the name. The refrigerant passingthrough compressor always flows to a constant direction and is able to reverse-operate completely the refrigeratingcycle of both cooling and heating by a reversing valve. Consist of reversing valve and solenoid valve. The mainvalve in reversing valve uses a nylon resin which is deformed by heat 120˚C or over and thus causes valve not towork, so be cautious while operating or when welding.
27) Check valve:Prevent refrigerant from reverse flow in refrigerating cycle. It is installed in a place where it is necessary to preventthe reverse flow of refrigerant in a copper pipe. It has a mechanical structure and attached to the opposite of aheating capillary to expand the heating/cooling model by two speeds, and is constructed so as to flow throughcapillary in heating and through the check valve in cooling only.
28) Solenoid valve
Regulate the refrigerant flow by refrigerant on/off in cycle which refrigerant flows according as the valve operatesthrough a coil unit being powered on. Mainly it is used when reversing the 4 way valve of a cooling/heating model orconstruction each unit cycle of multi model.
8/17/2019 AirCon Training Manual
7/175
7
3. PRINCIPLE OF OPERATING AIR-CONDITIONER
1) Four elements of air conditioning
(1) Temperature:The dry-bulb temperature by cooling or heating room air.
(2) Humidity:
A comfortable humidity condition of room air is generally kept by the relative humidity of air, and the room air iscontrolled into a given relative humidity condition.
(3) The degree of purity:Remove dusts in the air, and keep smoke from exceeding the allowable degree of concentration.
(4) Air flow:To disperse properly the air regulated in temperature, humidity and the degree of purity into indoor, make anappropriate air flow and keep uniformaly the temperature/humidity condition of room unit.
•Satandard for feeling comfortable
2) Principle of cooling Air-Conditioner
• Sprinkling with water in summer cause to cool surroundings because water absorbs the heat of surroundings• Gasifying a liquid (R-22) which is easier to evaporate than water cooler because water evaporates at 100˚C under
1 atmosphere but freon gas (R-22) does a very low temperature of -40°C.• It is an Aircon that the principle is used for
(1) Elements of Aircon
ClassificationTemperature
Relative humidity
Air flow
Summer21 ~ 28˚C
30 ~ 30%
0.2m/s or less
Winter20 ~ 24˚C
30 ~ 60%
0.2m/s or less
Cooling
1 Compressor
2 Condensor
3 Evaporator
4 Expansion valve
Cooling + Heating(Heat pump)
1 Compressor
2 Condensor
3 Evaporator
4 Expansion valve
5 4Way valve
8/17/2019 AirCon Training Manual
8/175
8
• Heat pump: Convert the flow of refrigerant (freon
gas) upon Coooling/ Heating by 4way valve.
• In colling operation, the flow of freon gas is same
as above, (4Way valve:electrically power off)
• The flow of freon gas
1 2 3 4 5
• Heat pump: Convert the flow of refrigerant (freon
gas) upon Coooling/ Heating by 4way valve.
• In Heating operation, the flow of freon gas is
reverse-operate completely by 4 way valve.
(4way valve: electrically power ON)
• The flow of freon gass
1 2 3 4 5
Evaporator4
Condensor2
3
1
Room AirOutside Air
Compressor
Expansionvalve
Indoor Outdoor
CooledAir Hot discharged Air
Heat Exchanger(evaporator)
Heat Exchanger(Condensor)
2
3
4
1
5
Room Air
4Way valve
Cooled Air
Indoor Outdoor
Hot discharged Air
Outside Air
Compressor
Expansionvalve
Compressor
Heat Exchanger(Condensor)
Heat Exchanger(evaporator)
4
3
3
15
Room Air
4Way valve
Hot discharged Air
Indoor Outdoor
Cooled Air
Outside Air
Compressor
Expansionvalve
Compressor
(2) Principle of operating
• Cooling
1 The low pressure freon gas is compressed incompressor and flow into condensor.
2 In condensor freon gas emits the heat by forced-convection fan and liquified by cooling.
3 Liquid passed through the expansion valve is spoutedin evaporator.4 Liquid in evaporator absorbs the heat from room air by
forced-convection fan and flowed into compressor as agasified state.
5 This circulation repeats (1~4)
8/17/2019 AirCon Training Manual
9/175
9
2. REFRIGERANT CYCLE1. REFRIGERATING CYCLE
Service valve
Room Air Conditioner
(Cycle of refrigeration)
Service valve
8/17/2019 AirCon Training Manual
10/175
10
2. THE PRINCIPLE OF REFRIGERATING CYCLE
¡
fl
The role of each cycle
1) Compression:The gasified refrigerant evaporated is absorbed into compressor through the suction pipe, and the compressed by apiston in cylinder and turned into a gas of high temperature and high pressure which is able to be liquified in a roomtemperature.
2)Liquification:
The gas of high temperature and high pressure in compressor is cooled by air in condenser and liquified by acondensing heat.
3)Expansion:
With passing through the capillary tube, the high pressure refrigerant liquified in condenser turns into a low pressurecondition, which is easy to evaporate.
4)Evaporation:
The liquid refrigerant of low temperature and low pressure passed though the capillary tube absorbs the room air heatin evaporator and evaporates into a gas.
Low pressGas
Compression
(Mid. Temp)
Compressor
High PressGas
Liquification
(Hi. Temp)
Emission Cooledd Air
Hot discharged Air Absorbing
Condensor
High PressLiquid
Expansion
(Hi. Temp)
Capillary
Low pressLiquid
Evaporation
(Low. Temp)
Evaporator
Low pressGas
(Mid. Temp)
8/17/2019 AirCon Training Manual
11/175
11
3. INSTALLATION1. INSTALLATION PROCEDURE
Select the location
Check and Caution
OK
YES
YES
YES
YES
Set Return
Refrigerant pipe andDrain pipe connections
Wiring
Test running
Insulation and Final Work
Check and Caution
OK
Check and Caution
OK
Check and Caution
OK
YES
Check and Caution
END
OK
1. Check the piping hole2. Select the distance in pipe length3. Vaccum and Air pauge4. Decide the refregerant suplement refill5. Check the leakage
1. Check the power of Aircon2. Install a leakage braker3. Check the power capacity4. Check the location of earth
1. Check the power source2. Check the leakage
3. Check the pressure4. Check the running current
YES
Check and Caution
OK
1. Check the construction of drain part2. Check the insulation3. Check the operating of set4. Explain to customer
1. Check the Environment2. Check the capacity of transport
3. Decide after the customer’s agreement4. Check the power capacity
1. Caution of damage.2. Keep the minimun space for service.3. Check the accessory and tools
8/17/2019 AirCon Training Manual
12/175
12
2. TOOLS REQUIRED
2-1 Tools
Screw driver
Assembly, disassmbly
Core drill(diameter 70mm)
Wall through
Hand drill
Indoor istallationPlate fixing
Monkey spanner(300mm):2EA
Indoor/Outdoor pipeconnection
Ruler, knife
Ruler: Length &distance measurement.
Knife: Tape cutting
Torque wrench
Indoor/outdoorpipe connection
Gas leak detector& soup water
Leak inspection
Hook meter (for currentmeasuremement)
Current, voltage,resistance measurement
Thermometer
Temperaturemeasurement at Indoorsuction inlet/discharge
outlet.
Insulation resistancemeter
Insulation resistancemeasurement (Electric
shock prevention)
Hex. wrench (Largeside:4mm, 5mm)
Service valveoperating
Flare tool set
Pipe cutting, Burrremoval
2.2 Accessory
Connection cable
Indoor-Outdoorwire connection
Refrigerant pipe(forhigh/low pressure)
Refrigerant circuitconnection to
Indoor/Outdoor.
Winter cover
Outdoor protectionin a unusedseason
like winter
Putty
Chaging of wallthroughhole
anti-vibration rubber
Vibration absorptionof outdoor
Vinyl tape
Wire & pipe finishing
Band
Wire & pipefinishing
Remocon fixture
Remocon hanger
Adhesive
Finishing
Fixture clampingscrew
Remocon fixturefixing
Drain hose
Drainage
Remocon
Clamp meter
Clamp meter Thermometer
Drive torch Mega tester
8/17/2019 AirCon Training Manual
13/175
13
3. INSTALLATION
3-1. SELECTION OF THE BEST LOCATION
Decide installation place with the customer’s agreement.
3-1-1. Indoor unit installation place• Select a place where the circulation of suction air and discharge air will be so good that the room temperature is
uniform sufficiently considering air arrival distance during cooling.
• In selecting indoor unit installation place, select a place where can ensure the minimum space indicated by the productspecification for service and cooling efficiency.
• Avoid following place1) A place where there is a danger of inflammable gas leakage.2) A place where there is a danger of electromagnetic interference.-hospital, etc
1. Install where a side of electromagnetic wave radiation transmitter does not face the main body of unit directly.2. In order to avoid noise effect, keep more than 3-m minimum distance from the devices of transmitting
electromagnetic wave.3) A place where there is a lot of oil or steam. (kitchen, cooking place, machine plant)
If installed in this place, as oil contacts heat exchanger, there is a great possibility of a frost generation in a poorheat exchanger, a deformation and a damage of resin parts, and a corrosion of heat exchanger.
4) A place where there is a lot of moisture.Be easy to frost a product during cooling.
5) A place where organic material is used.6) A place where cannot hold the weight of the products.7) A place where is not easy to drain.8) A place where is difficult to acquire service space.
3-1-2. Outdoor unit installation place• In selecting outdoor unit installation place, select a place where can ensure the minimum space indicated by theproduct specification for service and cooling efficiency.
• Avoid following place1) A place where discharging air turns toward neighbor’s window.2) A place where operation sound of outdoor unit is transmitted to neighbor.
Take into consideration that there is no damage to neighbor in the bound of neighbor.3) A place where is difficult to acquire service space.4) A place where is not easy to discharge air.5) A place where there is a heat source near the outdoor unit.6) A place where a strong wind may blow straightly against outdoor unit.7) A place where sunlight shine the unit directly. (If so, an awning must be built separately.)8) A place where the wall of an apartment or a building is not stable. (If not stable, falling outdoor unit can damage
human life or property.)9) A place where salty air or phosphoricacid chloride gas can be reached.
3-1-3. Remote controller
A place where there is no obstacles-curtain, etc-to disturbs a signal transmission of remote controller.A place where there is no direct sunlight or heat source around it.A place where separate more than 1-m from TV, radio, wireless phone, luminescent light, etc.If the neon lamp is near the product, it may not operate for electromagnetic interference.Protect them from neon lamp.
Caution) Refer the installation manual before the installation, because there can be special articles for theproducts.
8/17/2019 AirCon Training Manual
14/175
14
3-2. SET RETURN
• Transportation Method1) Please convey indoor and outdoor unit to the installation place in packing state as possible.2) Please take care to convey indoor and outdoor unit with no shock.3) Please do not use service valve with the use of carriage.4) Please do not carry front of the indoor unit on the back.
Can be damaged and deformed the side of grill.
3-3. Refrigerant pipe and drain pipe connections
3-3-1. Refrigerant pipe connections
• Working procedurePipe design – pipe manufacture – pipe connection – air purge – gas leak check – additional refrigerant charge(In case of exceeding the standard pipe length, 5-m)
1. Precautions in pipe design
Refrigerant pipe design affects deeply the efficiency of airconditioner, and wrong pipe constructions can be a cause of
airconditioner’s failure.Please refer to attached management explanation and service manual in the main body of unit about standard pipespecification of airconditioner product classification, tolerance of pipe length, tolerance of high and low difference, andan amount of additional refrigerant, etc,
Keep in mind the followings on pipe connections indoor and outdoor unit.1) Please use pre-defined pipe diameter and thickness.2) Additional charge is required according to the excessive length.
Before the shipment, this airconditioner is filled with the rated amount of refrigerant including additional amountrequired for air purging, subject to 5m-pipe length.
3) Please select the best short distance in pipe length.4) Please reliably fix pipe support.5) Please install oil trap per 10m to observe gas in case of vertical axis piping.6) Please high and low difference between indoor and outdoor unit is slight as possible in order not to exceed
tolerance range.7) Please take a special care of pipe management to protect dust, moist, and scales by sealing the end of pipe with
cap or tape.8) Please seal the end of pipe when go through the passing parts of the wall etc. and work.9) Please take care of the end of the pipe not to touch ground when pipe is placed on the ground directly.10) After pipe manufacturing, Remove burrs in the downward of the pipe.
Aircon Classification
Air pauge amount
Split Type
50g
Package Type
200g
Band
CAP or VINYL Band CAP or VINYL
No touch!
Burr removal
Pipe
Dust and refuse will insert in the pipe Burr will insert in the pipe
8/17/2019 AirCon Training Manual
15/175
11) On raining day, please take a special care to pipe-work.12) Please not to install unnecessary trap in order to protect the staying of refrigerating oil, refrigerant inside of inlet
gas pipe. Avoid the way gloving figure in case of crossing the axis as ceil side. In case of shortage of refrigerantbe a cause of refrigerating oil.
13) In case of installing gas pipe horizontally, work downward slanted 1/250 (length 5m to 2mm downward) in the flowdirection in order to be easy for refrigerant to flow.
14) Please keep the temperature of the gas pipe necessarily.If you tie with liquid pipe to keep temperature, compressor efficiency will be low because gas pipe overheating isgreat.
15) Because outlet operation temperature is over 80˚C, insulate necessarily a place where men, animals, and plantscan contact.In case that water pipe is short, it may not insulate, but as flash phenomenon can be brought to externaltemperature, be desired to keep temperature.
16) Please work to install the bit necessarily in case that refrigerant pipe is under ground.Please install the copper panel or concrete cover on the bit not to be pressed on upper-side pipe.If bit is not installed, expansion and stress for temperature change may cause to cut or leak it.
17) Refrigerant pipe through part can be absorbing the change of temperature and vibration in order to preventrefrigerant leakage under the following picture.
15
Cover
FloorTube
Bit
(Work to install the bit) (Work to install the hanger)
Wall
Wire Vinyl tape
Gas pipe
Insulation material
Liquid pipe
Protection pin
Hanger
Sleeve
Wall
Pipe
axics
IndoorUnit
IndoorUnit
8/17/2019 AirCon Training Manual
16/175
2. Pipe manufacturingBefore manufacture indoor/outdoor refrigerant pipe, decide method of refrigerant pipe connection. Use the simpleand speedy method of flare connection in case that pipe diameter is less than 3/4”. And connection method in thebelow picture is a method to connect flare nut with flare too set.For pipe diameter more than 3/4”, to be desired to braze cross other copper pipe after enlarge the pipe.
1) Flare manufacturing
• Using tool
a. Please cut thepipe with pipe cutter.
b. Remove burrs from cut edges of pipes.Caution: If burrs are not removed, they may cause gas leakage.
If scales enter the pipe, they may cause a freezing malfunction.
c. Insert the flare nuts, flare the pipe
16
Inclined Surface damaged Cracked Uneven thickness
Pipe cutter Enlarger
Reamer
Pipe
Enlarger bar
Out Diameter
ø6.35mm
ø9.52mm
ø12.7mm
A(mm)
1.3
1.8
2.0
Nominal diameter
1/4”
3/8”
1/2”
5/8”3/4”
D
6.35
9.52
12.7
15.8819.05
A
8.3~8.7
12~12.4
15.4~15.8
18.6~1922.9~23.3
90˚ Slant Burr
8/17/2019 AirCon Training Manual
17/175
17
2) Brazing manufacturing
3) The methed of banding refrigerant pipe
• Refrigerant pipe use connection pipe.• Insulate reliably refrigerant pipe 2-pieces as form dew or it may cause a malfunction.
(Please use polyethylene with insulates plate.)• Hold the tubing with your two hands closely and then bend or stretch it slowly not to make any crack.• Keep in mind that the bending part should not be cracked, and make the radius® as long as possible.
(Over R 50mm)• In case of unfolding, roll with pressing the end of it. (Refer to the below picture)
4) Material of refrigerant pipeCopper tube or steel tube can use Freon refrigerant pipe, but at actual place considering work and durability, isusing copper non-connection tube widely.Air-conditioning phosphor deoxidization copper tube (C1220T-OL)
a
Capillary
1/4~3/8”
1/2~11/8”
b
0.05~0.1
0.1~0.15
0.15~0.2
c
10~15
6~10
10~20
(Units:mm)
6.35
0.8
1/4”
9.52
0.8
1/2”
12.7
0.8
1/2”
15.86
1.0
5/8”
19.05
1.2
3/4”
22.2
1.2
7/8”
25.4
1.2
1”
28.6
1.2
9/8”
31.8
1.5
5/4”
35
1.5
11/8”
Pipe diameter
Thickness
INCH
(Units:mm)
More than R50mm Press down
Rolling
8/17/2019 AirCon Training Manual
18/175
18
3. Pipe connection
If paste refrigerating oil on the contacting side of flare, there is an effect of protecting gas leakage.Align the center of the pipe, rotate and tighten the flare nut with fingers, and tighten the flare nut with torque wrench inthe below picture.
Caution) if fastened by excessive force, flare part become destroyed
Connection torque: using 30Cm-monkey spanner, fasteningwith 10Kg-force, toque is 300KgCm, the number ofmultiplication of distance and forceLiquid Side
Gas Side
Pipe Size
6.35
9.52
12.7
15.88
Torque(kg.m)
1.5~2.0
3.1~3.5
5.0~5.5
7.0~7.6
Liquid side
PipeUnion
Nut
Gas side
8/17/2019 AirCon Training Manual
19/175
19
4. Air purge
On pipe connection, discharging air in pipe is air purge, do purge air necessarily, because it may cause pressurerising, operating energy loss, compressor overheating, cooling efficiency drop.Before the shipment, our products are filled with the additional refrigerant for air purge. On installation, Air purges theindoor unit and pipe by using refrigerant of the outdoor unit.
Caution) open the valves coke till it cannot rotate by stopper.Fasten reliably the valve cap with tools of spanner, etc.Use 4mm L-wrench to close or open the valve coke.
Open the cap of the valve B & A
Check the leakage of pipe connection portion.
Open completely the stopper of the valve B & A.
Close the each valve cap.
Check the gas leakage.
Open the stopper of valve B by 45˚C, close the stopperafter 10sec.(At this time, tools using control the pipe,exclusive L-wrench.)
* Open needle cap of the valve A, by pressing needlevalve during 3 sec, discharge gas, and repeat 3 timesin this order.
• Close the connection tube portion, If no leakage,proceed *.
• If it is required to repair for gas leakage, afterdischarge the refrigerant gas and repair the part ofleakage, vacuum again and charge refrigerant.
Liquid
Outdoor unitGasside
flare nut
Stopper
Cap
Needle valve cap
Indoor Unit
Liquid side
Service valveat liquid side
Service valveat gas side
Outdoor Unit
Gas side
8/17/2019 AirCon Training Manual
20/175
20
• Work method of air purge according to pipe length.
Ref) As air purge amount is different from products, Refer to installation manual of the products.
1) Air purge-using refrigerant in the unit.Working order is the same as the above mentioned.
2) Air purge using vacuum pumpWorking order is the same as follows.First. Connect the pipe of indoor and outdoor units. (At this time service valve is all closed in gas side and liquid side.)Second. Vacuum pump operator till the gauge’s pressure is to –76CmHg.Third. after close1, wait during 3-4min and check that pressure gauge is changed.If that is changed, check connections part and prevent refrigerant leakage in advance.Fourth. Open completely gas side and liquid side service valve with hexagonal wrench.
Method
Air purge-using Refrigerant in the units
Air purge using vacuum pump
Air purge using refrigerant bombe
Condition
Length of pipe 10m
Length of pipe > 10m
Length of pipe > 10m
Amount of air pauge
200g
200g
200~500g
Lowpressure
Highpressure
Vaccum Pump
Outdoor Unit
Indoor Unit
Pressure guage
Open Close
Gas Side
Liquid Side
8/17/2019 AirCon Training Manual
21/175
21
3) Air purge using refrigerant bombeWorking order is the same as follows.First. Connect the pipe of indoor and outdoor units. (At this time service valve is all closed in gas side and liquidside.)At this time, connect loosely flare nut4. (Can rotate by fingers)Second. Open 1, 3 and discharge air in the tube. Transparent air comes out and white gas is started todischarge. After 3 seconds at that time, close1,2,3.
Third. Open completely gas side and liquid side service valve with hexagonal wrench.
Pressure guage
CloseOpen
Outdoor Unit
Indoor Unit
Gas Side
Liquid Side
Lowpressure
Highpressure
8/17/2019 AirCon Training Manual
22/175
22
5. Leak Inspection
Please check the leakage of the connection parts by using leak detector and soup water.
Indoor Uint connection
Outdoor Unit Connection
Leak Detector
8/17/2019 AirCon Training Manual
23/175
23
6. Additional refrigerant charging
When measure the pressure with lack of the refrigerant, measure the pressure with manifold gauge after connecting tovalve.In case that the pressure is less than the standard, add the refrigerant as the following method.If the refrigerant contains too excessive refrigerant, liquid refrigerant will down the product quality.
Preparation of manifold gauge• Check that three valves is attached properly.• Check that left side (low pressure), right side (high-
pressure) handle is closed completely.• Check that there is a pin at the end of low pressure hose.
(1) Connect the middle hose of the pressure gauge to gascylinder, open the Gas side service valve of the gascylinder. (At this time, do not turn gas cylinder over.)
In holding state, the low pressure becomes differentaccording to the ambient temperature of the outdoor unit.
(3) operate airconditioner in cooling mode(fan speed/strong)
(4) In case of lower pressure than that, turn overrefrigerant gas cylinder.
(5) Loose the low-pressure valve of the pressure gaugeduring 2-3sec. And close again and wait during 4-5sec.
(7) After close the refrigerant gas cylinder, remove thehose of the low-pressure side, and close the cap of the
valves in original state.
(6) Till the pressure become 4-5kg/cm2 , repeat (5) work.
In case of proper refrigerant, pressure is about to 0 at first,10min later the pressure is stable in 4-5kg/cm2 .(The pressure can be changed according to the roomtemperature and humidity.)
(2) Open the low-pressure sided valve of the pressuregauge, discharge air in the hose. After 2-3sec. releasethe low part cap of the Gas side service valve andconnect the low-pressure sided hose(blue) to this place.Close the low-pressure sided valve after full connection.
Lowpressure
ClosePin
Red
YellowBlueLiquid side
servicevalve
Gas Side
Outdoor unit
Pipe
Spindle
Hose of Low pressure
Construction of Gas side service valve
Connect to valve
Close
Highpressure
8/17/2019 AirCon Training Manual
24/175
24
Precautions in charging refrigerant
• Before connect the hose of the pressure gauge to airconditioner, work necessarily (1), (2).• Do not encloses a lot amount of the refrigerant at once.• As the above message is the explanation of additional injection of the refrigerant.
When charge first after repairing the refrigerant cycle, vacuum sufficiently inside of the airconditioner and then chargerefrigerant.
• When charge the additional refrigerant, after operate necessarily in cooling mode (strong).
• In case that that is not a cooling mode, the low-pressure side can be changed.)
• Charging Additional refrigerant per length
Model
DSB-070L
DSB-091L
DSB-121L
DSA-151L
DSB-181L
DP-130E
DP-130H
DP-150E
DP-171M
DP-170H
DP-200M
DP-310M
DH-400M
Quantity of
Heat
[kcal/h]
1,800
2,270
3,000
3,550
4,280
4,500
4,500
5,100
6,100
6,100
7,100
9,600
12,500
Reference
refrigerant
[g]
800
1000
1200
1250
1150
2000
2000
2200
2200
2200
2100
3600
3800
Name
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid PipeGas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Pipe
Diameter
(D)
12.7
6.35
12.7
6.3512.7
6.35
12.7
6.35
12.7
6.35
15.88
9.52
15.88
9.52
15.88
9.52
15.88
9.52
15.88
9.52
15.88
9.52
15.88
9.52
19.05
12.7
Length
(L)
5m
5m
5m
5m5m
5m
5m
5m
5m
5m
5m
5m
10m
10m
8m
8m
10m
10m
10m
10m
10m
10m
10m
10m
10m
10m
Increase
Decrease
Increase
DecreaseIncrease
Decrease
Increase
Decrease
Increase
Decrease
Increase
Decrease
Increase
Decrease
Increase
Decrease
Increase
Decrease
Increase
Decrease
Increase
Decrease
Increase
Decrease
Increase
Decrease
20g/m
-17g/m
20g/m
-17g/m20g/m
-17g/m
20g/m
-17g/m
20g/m
-17g/m
40g/m
-37g/m
40g/m
-37g/m
40g/m
-37g/m
40g/m
-37g/m
40g/m
-37g/m
40g/m
-37g/m
40g/m
-37g/m
80g/m
-77g/m
S p l i t R o o m A
i r c o n
P a c k a g e R o o m A
i r c o n
Added refrigerant
per length
8/17/2019 AirCon Training Manual
25/175
25
7. Vacuum Method
The purpose of vacuum is to remove air and moisture in the refrigerant system.It is important to vacuum in the system. Air and moisture in the system may cause Pressure-rising, operating energyloss, compressor deterioration and freezing.In case that there is no remaining refrigerant in the tube because of leakage and repairs, vacuum by opening the gasside and the liquid side service valve.After the pipe connection of indoor and outdoor, must vacuum the tube after close the liquid side and the gas side
service valve.If vacuum is made completely, start directly to charge refrigerant in order not to be intruded by open air.And in case that required to discharge refrigerant for after-service, discharge slowly and do vacuum in order not todischarge refrigerating oil of the compressor.
Low pressure High pressure
Pressure guage
Open Open
Indoor Unit
Gas Side
Liquid Sige
Compressor
Vaccum pump
Outdoor Unit
8/17/2019 AirCon Training Manual
26/175
26
8. Pump down
• In order to prevent discharging refrigerant in moving or repairing, gathering the refrigerant of indoor and pipe insideis pump down.
Operate airconditioner in cooling mode (compressor mustbe operated.)
(1) Disclose the caps of the liquid side service valve andthe gas side service valve.
(2) Rotate the spindle of the gas side service valve right-sided and closes completely by using L-wrench.
(3) About 2 min. later, rotate right-sided and closecompletely the spindle of the gas side service valve
(4) Stop the airconditioner
Do required works.
Liquid side service valve
Gas side service valve
Operation states of the service valve
1The closing state before the shipment 2the mid-state in suctioning air 3the opening state in normal operation
A-BA-C
Close
B-C Open
A-B Open
A-CB-C
Close
A-B-C Open
8/17/2019 AirCon Training Manual
27/175
3-3-2. Drain pipe (hose) connection
• Drain hose is necessarily slanted outdoors• Drain hose must be slanted downward in order for good flow of condensing water.
• Arrangement of the drain hose(Check as the following items about the drain hose.)1. Is drain hose downward of others through the hole?2. Isn’s drain hose higher than drain hole because of loosing the hose?
3. Does water come out when pour water into condensing water rest?
Caution) As condensing water can overflow in bad insulation of drain part and drain hose connection of theairconditioner, Make sure to insulate connection part necessarily.
• In case that extension hose (drain hose) is in the room, please insulate the exterior of the hose.
27
Indoor
Insulation
Outdoor
Hose extension pant
Indoor drain hose extension hose Hose(general purchase)
Hose is higherthan unit
The end of hoseis gettinginto water
The end ofhose is being
crooked.
The gab of theground is small
The end of hoseis being in a water
spout
The connectionpant of hose isbeing crooked
water
spout
less than
5m
Connection Cable
Indoor Pipe
Drain Hose
Indoor Unit
8/17/2019 AirCon Training Manual
28/175
28
3-4. Power supply and wiring construction
3-4-1. Precaution before the work
1) Check that source voltage is rated voltage.2) Check that power capacity is sufficient to operate the airconditioner.3) Have an individual power specialized for airconditioner.4) Equip a suitable leakage braker for power capacity.
5) Provide a circuit braker switch between power source and units.6) Do not cut and connect the power code, that is a great danger.7) Make sure it is not connected to ac power before wiring to protect from electric cause.
3-4-2.wiring of indoor and outdoor
1) On wiring of indoor and outdoor, match the number of terminal block and the terminal number of connection cable.2) Connection cable can be short as possible by using specified cables (components).3) If wiring of indoor and outdoor is not correct, it may cause the trouble.4) Refer to installation manual according to the characteristics of the product about the others.
3-4-3. Earth work1) method of earth work
• In case of using already established earth• In case of using exclusive earth terminal
• In case of using earth of a switch board
• In case of using extraordinary earth pipe
Cable using in installingaircon(more than 1.6mm2 ornominal surface area over2mm2)
Electrical resistance:below 100Ω(past equipment)
Switch board
Cable using in installingaircon(more than 1.6mm2 ornominal surface area over2mm2)
Electrical resistance:below 100Ω(past equipment)
Terminal for earth
Carbo pipe or copper pipe
Nominal surface area over 2mm2 viny/wire(blue) Press terminal (M4 screw)
copper wire
8/17/2019 AirCon Training Manual
29/175
29
2) Procedure of earth workPlease do earth work completely in orders as the following table.
Order
1
2
3
4
5
6
work
selection of earthlocation
Burying earth pipe
Arrange earth line
Check and examination
Connection of earthpipe and airconditioner
Never contact in a greatdanger of connectingthe earth line to thefollowing place
explanations
suitable place1.a place where be always moist.
2.mud is better than sand
unsuitable place1.a place where be underground
establishment (gas pipe, water pipe,inlet pipe, underground cable)
2.keep the space over 2m betweenearth for a lightening conductor andearth wire
In case of having a burial tools1.Bury the earth pipe on ground surface2.Bury over 20Cm deeper by using the
burial tools
in case of having no burial tools1. dig the hole as the figure and bury
the earth pipe2. bury wholly the earth pipe with clay
In case of extension of short earth line,adhere the insulation and wrap withtapeFix the earth line unscramble withstemple
Check that the earth resistance withearth ohmmeter is satisfied to thespecified value after installation work.
In case that the earth resistance is notthe standard value, can be the standardvalue by burying the earth pipe deeperor adding the earth pipe.
Connect reliably Earth line and earthterminal of outdoor unit.
TV antenna, gas pipe, aluminum sassy,flower base, water pipe ( earth usingwater pipe can be use as earth polar incase of less than 3% resistance, buttake an approval of water administer inadvance)
cautions
Avoid sand ground, pebble groundfor a high earth resistance
Do not use publicly the earth forphoneFix completely earth line in case ofburying where passers-by are a lot.
Use vinyl cable that thickness isdiameter 1.6mm orNominal surface area is over 2mm2 ,blue
In case of being unable to avoid,take an approval of specialist inadvance and then do it.
check reliablyconnection part
check reliably connection part
earth pipe earth pipe burialtool
8/17/2019 AirCon Training Manual
30/175
3-5. Test running
• Check that source voltage is correct to the rated value.
• Operate in cooling mode for more than 20min. and then measure the temperature of in/out air in the indoor unit of theroom , check that the difference of the temperature is more than 80˚C.
• Check that service valve (gas-liquid side) is open before test running.• Do not test run by pressing harshly electronic contacting device.• Check that vibration, leakage and shocking exist.• Check s place where operation is unstable or overheating.• Check whether there is an obstacle in air inlet of indoor and outdoor unit.
• Check that earth wire is fixed reliably.
30
8˚C
cheoked voltage is within ± 10% of therated voltage
Measure the difference of the temperature
Suction part discharging part
8/17/2019 AirCon Training Manual
31/175
31
3-6. Insulation and final construction
• Finish work correctly so that rain water do not come into the room
• Wrap the connection part with insulation plate.• Block strongly the hole of the wall.• Wrap from the bottom to the top with finishing tape.
• Take care that indoor and outdoor connection cable and power cable has not to be contacted gas side service valveand pipe without insulation plate.
1.Dragin hose has to be installed under the pipe, not to be loose for hose.-Before installation, check if drain hose is separated from the products.(When that is separated, water flow into the room, so fit into the product reliably.
2. Take care that pipes does not come out in the back of the indoor unit.3. In case there is a pipe (copper pipe) exposed in indoors, make dew and fall into the room, exposed pipe is
required to insulate sufficiently.4. In case of bending the pipe, bend it not to make any crank for copper pipe as big radius (more than 100mm)
as possible.
wrap from the bottom to the top by tape
drain hose
connnection pipe
connnection cable
band
insulation vinyl tape
• Wrap the connection part of the pipe with insulateplate,Tie tightly both ends to have no gap with two bands
8/17/2019 AirCon Training Manual
32/175
32
3-7. Checking and conveyance
• Check the following items after complete installation
• Please explain airconditioner function, cleaning the filter to customer.
Appearance checking items
There is vibration, noise, trembling, etc. is the indoor unit mounted securely?
Bad cooling does the gas leak?Are there any obstacles in air inlet of indoor and outdoor unit?
Water falling insulates the pipe sufficiently?Isn’t there the drain hose higher than the drain hole?Does condensing water flow smoothly?
Unstable operation are all cables compatible to the standard value?
Or overheating is the source voltage correct to the rated value?
Generation of electric leakage does the ground wire earth certainly?
8/17/2019 AirCon Training Manual
33/175
33
4.MOVING METHOD
• Refer to it on house moving and movement of the installation place.
1) Do pump down (refer to details of pump down)2) Disconnect the power cord.3) Disconnect connection cable from indoor and outdoor unit.4) Remove the flare nut for pipe connection from indoor unit.
At this time, wrap the pipe and tube of indoor unit with cap or vinyl envelope, etc so that scales do not enter it.5) Disconnect connection pipe from outdoor unit
At this time, wrap the pipe and tube of indoor unit with cap or vinyl envelope, etc so that scales do not enter it.6) To prevent middle part of connection tube from bending or cracking, wrap in the proper size, and then preserve
and move it with cables.7) Move indoor and outdoor unit to specified place.8) Dissolve the indoor plate from the wall, and then move the place to install.
About pressure of the refrigerant cycle.
• If an actual temperature is low, the pressure become low.
• If the amount of refrigerant is insufficient, the pressure become low.• Dust is attached to the filter of indoor unit, the pressure of the low pressure part become low for decreasing amount of
the wind• By blocking the air suction of outdoor unit, decreasing amount of the wind make an operation of OLP.
- In case of becoming low in low pressure part:evaporator an suction pipe is freezing.
- In case that the refrigerant is too much:If aircon operates in a low actual temperature, evaporator and suction pipe is freezing.
- In case that the refrigerant is too small: overheating compressor operates overload.
8/17/2019 AirCon Training Manual
34/175
34
4. WINDOW ROOM AIRCONDITIONER
1.GENERAL SPECIFICATIONS
ITEM
MODEL
DWB-070C DWB-091C DWB-121C
Function Cooling only
Power source V / Hz AC 220 ~ 240V / 50Hz
Cooling CapacityBtu/h 7,300 8,600 11,700
Kcal/h 1,840 2,170 2,950
Energy Efficiency RatioBtu/hw 9.67 9.30 9.92
Kcal/hw 2.44 2.35 2.49
DehumidificationPts/h 2.02 2.49 3.30
g/h 920 1,130 1,500
Electrical DataPower Input 755 925 1,180
Running Current 3.2 4.1 5.2
Compressor
Type Rotary
Model QB134PL12A QK164PN12C QK196PN13A
Capacitor 25µF/400VAC 30µF/400VAC 35µF/400VAC
Model A9525TS401 A9525TS602 A2925CA070(DMI)/OBM2501P2(OS)
Fan MotorCapacitor 2µF/400VAC 3µF/400VAC 5µF/400VAC
Indoor-Fan Blower-Fan
Outdoor-Fan Propeller-Fan
Refrigerant (R-22)Control Capillary
Charge Amount (g) 380 480 730
DimensionsUnit(W x H x D) 18.5(W)x14(H)x18.9(D)Inch / 470(W)x358(H)x480(D)mm
Packing(W x H x D) 21.3(W)x17.9(H)x21.7(D)Inch / 540(W)x455(H)x550(D)mm
Weight Net Weight (Kg) 63 lbs (28.5Kg) 65 lbs (29.5Kg) 90.2 lbs (39.8Kg)
Gross Weight (kg) 66 lbs (30Kg) 68 lbs (31Kg) 97.5 lbs (43Kg)
23.6(W)x14.9(H)x21.0(D)Inch600(W)x380(H)x535(D)mm
26.1(W)x18.1(H)x22.6(D)Inch663(W)x460(H)x573(D)mm
8/17/2019 AirCon Training Manual
35/175
35
2. MAJOR COMPONENTS
NO PART NAME
1 AIR FILTER
2 GRILL FRONT
3 CABINET
4 BLADE VERTICAL
5 KNOB THERMOSTAT
6 KNOB SELECTOR
NO PART NAME
7 BLADE HORIZENTAL
8 AIR VENT
9 FRAME GUIDE TOP
10 FRAME WINDOW KIT
11 SHUTTER WINDOW
• DWB-121C
• DWB-070C / DWB-091C
4
15
6
3
2
7
9
0
q
4
15
6
3
2
65
2
3
7
4
8
11
10
9
1 65
2
3
7
4
8
1
8/17/2019 AirCon Training Manual
36/175
36
3. WIRING DIAGRAM
COMP
F.M
R
C
O.L.P BR
RD
OR
OR
GY
GN
(Lo)
(Hi)
WH
CAPACITOR
BR
YW
BL
Hi-FAN
LO-FAN
LO-COOL
Hi-COOL
OFF
SELECTOR SWITCH
BK AC115V/60Hz
21
4
87
THERMOSTAT
F
S
C
H
(BL) (BR)
OFF
YEL
RED
GRY
BLU
BLUWHTYEL
L C
1 6
7 2
4
8
HIGHCOOL
MEDCOOL
LOWCOOL
LOWFAN
MEDFAN
FANMOTOR
COMP
SELECTOR SWITCH
THERMOSTATSWITCHO.L.P
CAPACITOR
H
GRN(GRN/YEL)
RED
BLK
WHT(BLU)
D L K ( B R N )
G R N ( G
R N / Y E L )
R
S
C
ORG
BLK(BRN)
CF
• DWB-121C
• DWB-070C / DWB-091C
8/17/2019 AirCon Training Manual
37/175
37
4. FUNCTION OF MAIN COMPONENTS
1. ROTARY SWITCH (SELECTOR)
Please refer to the part of selector in the chapter 9 (Wiring Diagram).The rotary switch (selector) controls the fan motor’s rotation speed, and has five positions.The function of the five position is as follow.
OFF: This po sition s tops all operations of the airconditioner.
HIGH COOL: This position provides the maximum airflow for rapid cooling, dehumidifying anddust removing operations.(Use this position on sultry summer days.)
LOW COOL: This position provides the minimum air flowfor quiet cooling, dehumidifying operations.(Use this position on suitable for night-time.)
HIGH FAN: This position provides the maximum air fiowalone fan operation without coolingoperation.
LOW FAN: This position provides the minimum air flowair flow alone fan operation without coolingoperation.
2. THERMOSTAT (TEMPERATURE CONTROL)
The Thermostat automatically starts and stops operation in order to keep the roomtemperature at a proper level, and this results in efficient use of power and economical
cooling.
Turn clockwise for a cooler room temperature.
Turn counter-clockwise for a warmer room temperature.
3. MOTORThe motor is used to rotate the indoor and outdoor fan so that the room air can be recirculated.
4. FAN
BLOWER FAN: The Blower draws hot air from the room through the Evaporator and then discharges it back into thecool air. It circulates the room air.
PROPELLER FAN: The propeller draws outdoor air through louvering and cools Condenser, and then blows the hotair out.
5. CAPACITORThe Capacitor enlarges the difference of phase between main coil and sub coil so that the Compressor and Fan Motorstarts well.
6. ACCUMULATORThe Accumulator blocks the unflow of liquid refrigerant and impurities into the Compressor.
SELECTOR
HIGH
COOL
HIGH
FAN
LOW
COOL
LOW
FAN
OFF
THERMOSTAT
COOLER
• DWB-070C / DWB-091C • DWB-121C
8/17/2019 AirCon Training Manual
38/175
38
5. TROUBLE SHOOTING GUIDE
TROUBLE SITUATION ANALYSIS CAUSE REMEDY
Fan motor and
compressor do not
run
Switch is in “cool”
position but the
compressor does not
run
1. Power failure
2.Power is supplied,
but the equipment
does not run
1. Not operating at all
2. Compressor
3. Frequent start and
stop
1) Power plug
2) Circuit breaker
1) receptacle
2)Operation switch
3) Cord or lead wire to
the switch
1) Compressor
2) Thermostat
3) Selector switch
4) O.L.P
5) Capacitor
1) Electricity
2) Room temperature
and outside
temperature
3) Compressor
4) O.L.P
5) Capacitor
1) Thermostat
2) Capacitor
3) O.L.P
1) Power failure
2) Circuit breaker is tripped
3) Power plug is not contacting
¡ Disconnection
¡ Mechanical failure of switch
1) Disconnection
2) Malfunction of contact
¡ Disconnection or burned-out
1) Failure
2) Malfunction
3) Knob is not set to the proper
setting
¡ Failure of malfunction of proper
setting
1) Disconnection
2) Malfunction of contact
¡ Lack of capacity¡ Disconnection
1) The voltage exceeded allowed
range (220V-240V)
2) Capacity of wire is not
sufficient
¡ Extremely high
¡ Burned-out
¡ Malfunction
¡ Lack of capacity
¡ Malfunction
¡ Lack of capacity
¡ Malfunction
¡ Consult your electric company
¡ In case of a breaker, turn it on
and off a few times
¡ Replace the power plug
¡ Repair or replace the
receptacle
¡ Replace the cord or lead wire
¡ Replace the compressor or
connection wire
¡ Replace
¡ Repair or replace
¡ Turn knob for cooler setting
¡ Repair or replace the swtting
¡ Repair
¡ Repair or replace
¡ Replace
¡ Repair
¡ Consult your electric company
¡ Check the capacity of wire
¡ Ventilate well and remove the
heat source
¡ Replace
¡ Replace
¡ Replace
¡ Replace
¡ Replace
¡ Replace
8/17/2019 AirCon Training Manual
39/175
39
TROUBLE SITUATION ANALYSIS CAUSE REMEDY
The compressor runs
but the motor doesn’trun
Both fan motor andcompressor are
running but cooling isbad
Vibration & Noise
Water leakage intoroom
Electric shock
(Leakage of current)
Not cooling at all
Insufficient cooling
1) Fan2) Fan motor3) Capacitor4) Fan motor circuit
Refrigerant system
1) Refrigerant system
2) Filter
3) Heat exchanger ofcondenser
1) Installation place
2) Fan
3) Fixing screws
4) Electriccomponents
¡ Installation condition
¡ Insulation of
components
¡ Blocked by others
¡ Disconnection or burned-outelectric cord
¡ Failure malfunction of contact
¡ Disconnection of malfunction ofcontact
1) Refrigerant system is choked
2) Compressor failure
3) Leakage of refrigerant gas
1) Refrigerant system is choked
2) Compressor failure
3) Leakage of refrigerant gas
4) Refrigerant charge is too high
¡ Clogged up with dust
1) Fin is cogged up with dust
2) The ventilation is not good
3) The unit is exposed to thesunlight
4) Other heat source is added inthe room
¡ Installation of the unit isimperfectly done
1) Fan is contacted withobstacles
2) Fixing bolt
¡ Have a screw loose
¡ Electrical noise
¡ The front is lower than rearside
1)Insulation defect of wiring and
lead wire
2) Leakgae of current due to thedew or rust
¡ Repair
¡ Replace the fan motor
¡ Replace
¡ Check the circuit
¡ Repair
¡ Repair
¡ Recharge refrigerant gas
¡ Check and repair refrigerantsystem
¡ Replace
¡ Check a part of Leakage andrepair
¡ Repair and recharge
¡ Clean the air fiter
¡ Clean the unit
¡ Shade the unit from the
sunlight¡ Remove the added heat
source
¡ Install the unit perfectly
¡ Remove obstacles
¡ Tighten the bolt
¡ Tighten the screw
¡ Exchange the components
¡ Make rear side of the unit lowerthan the front
¡ Check the unit’s Leakage of
current.
¡ Replace the defective parts orcomponents
8/17/2019 AirCon Training Manual
40/175
40
6. HOW TO DISASSEMBLE
1 Before service of 1. Stop the unit, remove the power cord from the receptacles.any part. 2. Move the unit to the safe location for the suitable work.
2 Ass’y Fan Motor 1. Remove Front Grill
- Fan Motor - Remove Filter Pre.
- Propeller Fan - Remove screw in Front Grill. (DWB-070C/091: 1 point, DWB-121C: 2 point)
- Blower Fan 2. Remove Cabinet from the unit.
- Remove screws from the unit’s sides.
(DWB-070C/091C: 8 point, DWB-121C: 2 point)
3. Remove holder scroll. (DWB-121C)4. Remove Scroll upper.
5. Remove Plate Scroll (DWB-070C/091C)
- Remove screws (3 point) from Plate Scroll’s sides.
6. Remove Ass’y Control Box
- Remove screws (DWB-070C/091C: 3point, DWB-121C: 4 point).
- Remove wires in the each components.
7. Remove wires in the Panel Housing.
8. Remove screws from Ass’y Fan Motor’s sides.
(DWB-070C/091C: 7 point, DWB-121C: 4 point)- Ass’y Fan Motor is assembly of Fan Motor, Propeller and Blower Fan,
Orifice and Panel Housing.
9. Lift the Ass’y Fan Motor from the unit.
10. Remove hex-nut (DWB-070C/091C: hex-nut 2 point, DWB-121C: CI:P Fan
2 point)from the shaft of Fan Motor.
11. Remove Propeller Fan from the shaft of Fan Motor.
12. Remove Blower Fan from the shaft of Fan Motor.
13. Remove Fan Motor from Panel Housing.
- Remove screws (4 point).
3 Ass’y Control Box 1. Same as the procedure 1 to 5 in the Item 2.
- Rotary Switch (selector)
- Thermostat
- Capacitor
- Power Cord
4 O.L.P 1. Same as the procedure 1 to 2 in the Item 2.
2. Remove Terminal Cover from Compressor.- Remove hex-nut (1 point).
Please refer to the chapter (Exploded diagram and parts list).
8/17/2019 AirCon Training Manual
41/175
41
7. EXPLODED DIAGRAM AND PARTS LIST.
DWB-070C, DWB-091C PARTS LIST
NO. CODE COMPONENTS Q’TY SPECIFICATION REMARK
1 3100300700 PAN BASE 1 PP+T30% or PP+CACL3(40%)
2 3106002400 COMP BOLT 3 M8XP1.25XL57
3 3106600400 SCROLL LOWER 1 EPS
4 2221040001 SEALING PUTTY 0.05 GRAY (PGE000901)JOINT SEALER
53100049100 COMPRESSOR 1 QB134PL12A, 220V-50HZ DWB-070C
3100049400 COMPRESSOR 1 QB164PN12C, 220V-50HZ DWB-091C
6 – GROMMET 3 EPDM 45
7 7400208411 WASHER PLAIN 3 M8(ID8..4XOD22XT1.6)
8 7392801211 NUT LOCK 3 M8XP1.25 (RIGHT SCREW)
9
3100029400 ASS’Y CONDENSOR 1 2RX1CX17S DWB-070C
3100049700 ASS’Y CONDENSOR 1 3RX2CX17S DWB-091C
10 7112401611 SCREW TAPPING 2 T1 TRS 4X16 MFZN
113104414400 PIPE COND IN 1 C1220T-OL. OD7.94XT0.7 DWB-070C
3100049800 PIPE COND IN 1 C1220T-OL. OD7.94XT0.7 DWB-091C
12 3100034310 ASS’Y PIPE CAPILLARY 1 DWB-070C
133104414610 PIPE CAPILLARY 1 C1220T-0, ID1.6XL1,100 DWB-070C
3104401400 PIPE CAPILLARY 1 C1220T-0, ID1.0XL400X2 DWB-091C
143100029300 ASS’Y EVAPORATOR 1 2RX2CX12S DWB-070C
3100049600 ASS’Y EVAPORATOR 1 3RX2CX13S DWB-091C
15
3100034500 ASS’Y PIPE EVA OUT 1 DWC-070C DWB-070C
310005000 ASS’Y PIPE EVA OUT 1 DWC-091C DWB-091C
16 3100034400 ASS’Y PIPE EVA IN 1 DWC-070C / DWC-091C
17 3100034600 ASS’Y PIPE SUCTION 1 DW-070C
18 7112401611 SCREW TAPPING 2 T1 TRS 4X16 MFZN
193108003300 MOTOR FAN 1 A9525TS401, 220V-50Hz DWB-070C
3108003500 MOTOR FAN 1 A9525TS602, 220V-50Hz DWB-091C
20 3104201500 PANEL HOUSING 1 SGCC Z-27
21 3101402400 COVER ORIFICE 1 PP
22 7S432X4081 SCREW TAPTITE 4 TT3 TRS 4X8 SE MFZN
23 7122401211 SCREW TAPPING 3 T2S TRS 4X12 MFZN
24 3101801820 FAN BLOWER 1 ABS Ø8
25 3106000600 WASHER PLAIN 1 M6(ID6.4XOD19.8XT1.6)
26 3106000500 NUT HEX(R) 1 M6(RIGHT SCREW)
27 3101801910 FAN PROPELLER 1 ABS+GF20% Ø8
28 3106000600 WASHER PLAIN 1 M6(ID6.4XOD19.8XT1.6)
29 3106000400 NUT HEX(L) 1 M6(LEFT SCREW)
30 3100700600 BUSHING GUIDE 1 NBR(HS 60˚±5˚)
31 3103800400 LOCK TWIST STANDOFF 3 DASTL-3NA
32 3100700900 BUSHING HOUSING 1 NBR(HS 60˚±5˚)
33 3100504000 BOX CONTROL 1 SGCC T0.8X332X270P REGULLAR-SP.
34 5S10503100 S/W ROTARY 1 DAESUNG SRB 315-4-7D, 5-STEP
35 7001400611 SCREW MACHINE 4 M/C PAN 4X6 MFZN
36 5SM0101600 THERMOSTAT AS 1 PFA 602D-06B
8/17/2019 AirCon Training Manual
42/175
42
NO. CODE COMPONENTS Q’TY SPECIFICATION REMARK
373109502100 CAPACITOR 1 2/25µF, 370/400VAC DWB-070C
3106900900 CAPACITOR 1 3/30µF, 400VAC DWB-091C
38 3101201600 CLAMP CAPACITOR 1 SGCC T0.8X113XCOIL REGULLAR-SP.
39 7S432X4081 SCREW TAPTITE 1 TT3 TRS SE 4X8 MFZN
40 3101396120 POWER CORD 1 KKP-550A(AUSTRIA, ARGENTINA)
41 7S432X4081 SCREW TAPTITE 1 TT3 TRS SE 4X8 MFZN
42 7S432X4081 SCREW TAPTITE 1 TT3 TRS SE 4X8 MFZN
433103524300 LABEL CIRCUIT 1 P.E T0.05 DWB-070C
3103524400 LABEL CIRCUIT 1 P.E T0.05 DWB-091C
44 3100701100 BUSHING COVER 0.4 DACB-008(L=300)
45 3102702100 HARNESS ROTARY S/W 1 AWG-16UL(BR)
46 3108502900 SEAL CONTROL BOX 1 F-US, 258X264XT5(D/G)
47 3102702000 HARNESS COMP ASSY 1 AWG-16, UL(BR/RD/OR)
48 — OVER LOAD PROTECT 1 MRA12012-12003 DWB-070C
OVER LOAD PROTECT 1 MRA98776-12026 DWB-091C
49 — GASKET 1 SILICON
50 — COVER TERMINAL 1 PC
51 — NUT(HEXAGON GLANGE) 1 HEXACON FLANGE
52 3108502700 SEAL EVA TOP 1 F-US, 350X40XT5
53 3104504800 PLATE SCROLL 1 PP+T30
54 3108503800 SEAL SCROLL 1 F-US, 115X60XT5(D/G)
55 7122401211 SCREW TAPPING 3 T2S TRS 4X12 MFZN
56 3106600300 SCROLL UPPER 1 EPS
57 3108502800 SEAL COND TOP 1 F-US, 400X30XT10
58 3100034900 CABINET ASSY 1 DW-070(STOP WELDING)
59 3100603400 BRACKET CABINET 1 DW-070
60 3104505600 PLATE WINDOW TOP 1 SECC T1.2X82.5X466.5(GY-258D)
61 7S432X4081 SCREW TAPTITE 3 TT3 TRS SE 4X8 MFZN
62 3108503100 SEAL CABINET TOP 1 F-US+F-PE(470X155XT10/2)
63 3108503200 SEAL CABINET SIDE(L) 1 F-US(310X90XT5)
64 3108503400 SEAL CABINET SIDE(R) 1 F-US(310X155XT5)
65 3108503000 SEAL CABINET FLANGE 1 F-US(540X10XT5)
66 7112401211 SCREW TAPPING 6 T1 TRS M4X12 POLY/WAS MFNI
67 3102401900 GRILLE FRONT 1 ABS
68 3108503700 SEAL FRONT(C) 2 F-US(80X20XT30)
69 3108503500 SEAL FRONT(A) 1 F-US(600X20XT10)
70 3108503600 SEAL FRONT(B) 1 F-US(420X20XT10)
71 3106501100 BLADE 2 PP
72 3101600400 DECO FRONT 1 PC T0.4
73 7122401211 SCREW TAPPING 1 T2S TRS 4X12 MFZN
74 3100035200 ASS’Y KNOB 2 DW-070
75 3101901800 FILTER PRE 1 ABS+MESH#32
8/17/2019 AirCon Training Manual
43/175
43
DWB-070C EXPLODED DIAGRAM
8/17/2019 AirCon Training Manual
44/175
44
DWB-091C EXPLODED DIAGRAM
8/17/2019 AirCon Training Manual
45/175
45
DWB-121C PART LIST
No. CODE COMPONENTS Q’TY SPECIFICATION REMARK
1 3102402400 GRILL FRONT 1 HIPS
2 3103400700 KNOB 2 HIPS
3 3101600600 DECORATE FRONT 1 PC FILM
4 3101902100 FILTER PRE 1 HIPS
5 3106501800 BLADE VERTICAL 1 HIPS
6 3106501700 BLADE HORIZENTAL 2 PP
7 3108503600 SEAL GRILLE 1 F–US
8 3108100900 PAN BASE 1 SGCC T1.0
9 3107400800 ASS’Y EVAPORATOR 1 350X330.2(ø9.52 2R2C) DWC-121C/CS(ONLY)
10 3104421100 PIPE EVA IN 1 C1220T–O OD9.52 DWC-121C/CS(ONLY)
11 3100063600 PIPE EVA OUT AS 1 C1220T–O OD9.52 DWC-121C/CS(ONLY)
12 3104421700 PIPE EVA OUT 1 1 C1220T–O OD9.52 DWC-121C/CS(ONLY)
13 3104423100 PIPE SUNCTION 1 C1220T–O OD12.7 DWC-121C/CS(ONLY)
14 3100061600 PIPE CAPILLARY AS 1 C1220T–O ID1.6 L800 DWC-121C/CS(ONLY)
3100061610 PIPE CAPILLARY AS 1 C1220T–O DWA-150C/CS(ONLY)
15 3107101190 COMP AS 1 LG–QK164CN12DWC-121C/CS(ONLY)
– COMP AS 1 LG–QJ196KC23 DWA-150C/CS(ONLY)
16 3104425800 PIPE DISCHARGE 1 C1220T–O OD7.94 DWC-121C/CS(ONLY)
17 3100063500 PIPE COND OUT AS 1 C1220T–O OD7 DWC-121C/CS(ONLY)
18 3100063400 PIPE COND IN AS 1 C1220T–O OD7 DWC-121C/CS(ONLY)
19 3106800300 ASS’Y CONDESOR 1 515X341.5 (ø7 3R2C) DWC-121C/CS(ONLY)
3106800310 ASS’Y CONDESOR 1 515X341.5 (ø7 3R2C) DWA-150C/CS(ONLY)
19-1 3108504300 SEAL COND TOP 1 F–US DWC-121C/CS(ONLY)
20 3101202800 CLIP FAN 2 SK-5
21 3101802600 PAN BLOWER1 ABS
22 3101404100 COVER MOTOR 1 EPS
23 3104202000 PANEL HOUSING 1 SGCC T1.024 3102000500 FIXTURE RUBBER 1 NBR
24-1 3100000010 BUSHING GUIDE 1 NBR
25 3108005100 MOTOR FAN 1 DAEWOO MOTOR (AM 12DWD11) DWA-150C/CS(ONLY)
26 7007501211 SCREW HEX 4 SX12MFZN
27 3101802700 FAN PROPELLER 1 ABS + GF20%
28 3102201100 WINDOW KIT FRAME(L) 1 HIPS
29 3102201000 WINDOW KIT FRAME(R) 1 HIPS
30 3100604200 PLATE WINDOW TOP 1 SGCC T1.2
31 3100801400 CABINET AS 1 SGCC T0.8
32 3100604300 BRACKET WINDOW LOWER 2 SGCC T0.8
33 3100604500 BRACKET SILL 2 SGCC T1.6
8/17/2019 AirCon Training Manual
46/175
46
No. CODE COMPONENTS Q’TY SPECIFICATION REMARK
34 3106600600 SCROLL LOWER 1 EPS
35 3103700100 LEVER VENT 1 PP
36 3103700100 WASHER VENT 1 PP
37 3104600100 RING VENT 1 NBR
38 3107000100 CLIP THERMO 1 ABS
39 5SM0101700 THERMOSTAT AS 1 PFA 602GF
40 5S10405100 SWITCH ROTARY 1 SR6B41610D
41 3101300600 POWER CORD 1 MP 231 250V/10A
42 3109503300 CAPACITOR 1 400VAC 5/35µF
43 3101201600 CLAMP CAPACITOR 1 SGCC T0.8
44 3966031000 MOTOR SWING 1 200/220V 50/60Hz
45 3100508500 BOX CONTROL 1 SGCC T0.8
46 3106600500 SCROLL UPPER 1 EPS
47 3103002800 HOLDER SCROLL 2 SGCC
48 3104409300 PIPE RUBBER BUTYL 1 –
49 3102708800 HANESS COMP AS 1 UL1015–16,BLK,RED,WHT
50 3103200500 CAP DRAIN 1 ABS
8/17/2019 AirCon Training Manual
47/175
47
DWB-121C EXPLODED DIAGRAM
8/17/2019 AirCon Training Manual
48/175
48
5. SPLIT ROOM AIRCON
MODELDSB-070L DSB-070LH DSB-091L DSB-091LH
ITEM
Function Cooling Cooling & Heating Cooling Cooling & Heating
Class T T T T
Power AC 220~ 240V/ 50Hz AC 220~ 240V/ 50Hz AC 220~ 240V/ 50Hz AC 220~ 240V/ 50Hz
CapacityW 2,051 2,051 / 2,051 2,637 2,637 / 2,637
Btu/h 7,000 7,000 / 7,000 9,000 9,000 / 9,000
Dehumidification l/h 0.89 0.89 1.15 1.15
Running Current A 2.9 3 / 3.2 4.2 4.0 / 4.2
Power Input W 680 676 / 693 920 910 / 940
Starting Current A 18 18 21 24
Type Rotary Rotary Rotary Rotary
Model QB 125PL 12B QB 134PL 12B QBB090A001 QK 164PN12F RBB100A001 QK 185PN13B
Capacitor 25µF / 370VAC 25µF / 400VAC 25µF / 370VAC 30µF / 370VAC 30µF / 450VAC 35µF / 400VAC
Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Type Cross flow fan Propeller fan Cross flow fan Propeller fan Cross flow fan Propeller fan Cross flow fan Propeller fan
Capacitor 1.0µF 400VAC 1.8µF 400V 1.0µF 400VAC 1.8µF 400V 1.0µF 400VAC 1.8µF 400V 1.0µF 400VAC 1.8µF 400V
Motor Model Number IC-8417DWKF5A IC-9625DWLF5A IC-8417DWKF5A IC-9625DWLF5A IC-8417DWKF5A IC-9630DWLF5A IC-8417DWKF5A IC-9630DWLF5A
Control Capillary Capillary Capillary Capillary
Charge Q'ty g 800 900 1,000 1,150
Type Flare Flare Flare Flare
OD(Liquid/Suction) in(mm) 1/4 (6.35) 1/2 (12.7) 1/4 (6.35) 1/2 (12.7) 1/4 (6.35) 1/2 (12.7) 1/4 (6.35) 1/2 (12.7)
Dimensions (W x H x D) mm 750x245x174 654x549x256 750x245x174 654x549x256 750x245x174 654x549x256 750x245x174 654x549x256
Net Weight kg 7.0 34 7.0 34 7.0 34 7.0 34
ElectricalData
Compressor
FanMotor
Refrigerant(R-22)
Connection
1.GENERAL SPECIFICATIONS
8/17/2019 AirCon Training Manual
49/175
49
MODELDSB-121L DSB-121LH DSA-151L DSA-181L DSB-181L DSB-181LH
ITEM
Function Cooling Cooling & Heating Cooling Cooling Heating
Class T T T
Power AC 220~ 240V/ 50Hz AC 208~ 230V, 60Hz AC 208~230V, 60Hz AC 220~240V, 50Hz AC 220~ 240V/ 50Hz
CapacityW 3,507 3,654 / 3,946 4,300 5,100 5,100 5,110 5,400
Btu/h 12,000 12,500 / 13,500 15,500 17,500 17,500 15,500 18,500
Dehumidification l/h 1.53 1.6 1.98 2.3 2.3 2.2
Running Current A 5.7 7.0 / 6.5 6.6 8.3 9.8 10.8 11.5
Power Input W 1.250 1,500 / 1,410 1,450 1,785 1,950 2,050 2,230
Starting Current A 34 37 42 44 46
Type Rotary Rotary Rotary Recipro Rotary
Model RCB120A001 RCB150A001 RCA150A001 ECB185211A CRDQ-0200-PFJ 2JS350D6BA02
Capacitor 25µF / 400VAC 35µF / 400VAC 30µF / 400VAC 35µF / 370VAC
Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Type Cross flow fan Propeller fan Cross flow fan Propeller Fan Cross flow fan Propeller fan
Capacitor 1.0µF 400VAC 3.5µF 400V 1.2µF 400VAC 1.2µF 450VAC 3µF 370VAC
Motor Model Number IC-8428DWKG7C IC-9430DWLC5B IC-9425DWKH6A IC-9425DWKH6A IC-9425DWKC5A IC-9425DWKC5A AM12DPD04
Control Capillary Capillary Capillary
Charge Q'ty g 1,300 1,060 1,250 1,450 1,150 1,320
Type Flare Flare Flare
OD(Liquid/Suction) in(mm) 1/4 (6.35) 1/2 (12.7) 1/4 (6.35) 1/4 (6.35) 1/2 (12.7)
Dimensions (W x H x D) mm925x285x194 1,035x322x205 (Indoor)
1,035x322x205 800x615x277
800x615x277 (Outdoor)
Net Weight kg 9.7 34 43 44 55.8 12.1 51.9
ElectricalData
Compressor
FanMotor
Refrigerant(R-22)
Connection
666x552x264(Before)
654x549x256(After)
8/17/2019 AirCon Training Manual
50/175
50
750
Plate Mounting
REMOCON
Connecting Pipe
Grille Insert
245
REMOTE CONTROLLER
Frame Grille
Body
Plate Mounting
174
2. STRUCTURE & PARTS OF NAME
1) OUTLINE DIAGRAM OF INDOOR UNIT
¡ DSB-070L/LH, DSB-091L/LH
REMOCON
Filter - L Filter - R
Grille Insert
Frame Grille
Body
Plate Mounting
Connecting Pipe
Plate Mounting406
194
2 8 5
925
R EMO TEC O N TR O LLER
¡ DSB-121L/LH
1035
205
322
453
¿‹ Æ˘˜ ˙`
”fi `⁄˘̇
`⁄„«…–‚fi‚ ̃
‰˙‡»– ‚Ø– ‚–
‰˙‡»– ‚ ˆ…
¡ DSA-151L/DSA-181L/DSB-181L
8/17/2019 AirCon Training Manual
51/175
51
256
549
654
2) OUTLINE DIAGRAM OF OUTDOOR UNIT
¡ DSB-070L/LH, DSB-091L/LH, DSB-121L/LH
277
367
615
800
¡ DSA-151L/DSA-181L/DSB-181L/DSB-181LH
Inlet
Inlet
Outlet
Outlet
Foot
Foot Cushion
Handle
Cabinet Side Panel Top Guide Support
Service Valve
Cabinet Front
InletInlet
Outlet
Foot
Handle
Panel Top
Cabinet
Service Valve
DischargeGrille
8/17/2019 AirCon Training Manual
52/175
52
REMOTECONTROLLER
Electrostatic Filter
Deodorizing Filter
Air Inlet
Remote ControllerReceiver
Power Plug
Remote Controller
Fan Direction(Up, Down)
Air Outlet
Antibacterial Filter
Lamp
3) STRUCTURE & PARTS OF NAME
(1) INDOOR UNIT
¡ DSB-070L/LH, DSB-091L/LH
Remote Control Signal Receiver
This place is the part to receive the signal if itreceive the signal, you can hear the signal “beep.“beep. beep.”
There is a switch panel at inside of FrontPanel. At the time of operating, open theFront Panel.
Emergency switch can be used when the remotecontroller is lost or Testing.
Remote switch is usually used by remotecontroller.
Indoor Unit Display Switch Panel
Timer (Yellow)Lights during the time
reservation mode.
Quick (Red)
ON (Red)
Lights when the
operation is going on.
Air clean (Green)
EMR. REMOCON
8/17/2019 AirCon Training Manual
53/175
53
¡ DSB-121L/LH
Power Plug
, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Electrostatic Filter Deodorizing FilterAir Inlet
AntibacterialFilter
Air Outlet Fan Direction(Up, Down)
Remote Controller
RemoteControllerReceiver
Lamp
R E M O T E C O N T R O L L E R
Remote Control Signal ReceiverThis place is the part to receive the signal if it receive thesignal, you can hear the signal "beep, beep".
Timer (Yellow)Lights during the timereservation mode.
ON (Red)Lights when theoperation isgoing on.
There is a switch panel at inside of FrontPanel. At the time of operating, open theFront Panel.
Air clean (Green) Quick(Red)
EMERGENCY REMOTE
Remote switch is usally used by RemoteController.
Emergency switch can be used when the remotecontroller is lost or testing.
Indoor Unit Display Switch Panel
ON AIR CLEAN QUICK TIMER
8/17/2019 AirCon Training Manual
54/175
54
¡ DSA-151L, DSA-181L, DSB-181L/LH
Indoor Cover
Electrostatic FilterRemoves dust
particles from the air.
(Option Filter)
Deodorizing Filter
Removes bad
smells from the air.(Option Filter)
Emergency/Remote SwitchSlide to select
the desired position.
IndicatorsIndicate the
AC setting.
Remote Sensor
Power Plug
Air CleaningFiltersRemoves dust
and prohibitsgerms.
AIR OUT
Air In
Sensor Wire
Fan Direction(Up/Down)
Fan Direction(Left/Right)
O N O F F
E N T E R C
A N C E L
T I M E R
R E S E T F
A N D I R
.
F A N S
P E E D
M O D E
S L E E
P
O N / O F
F
T E M P
.
LCD Remote Controller
Remote Control Signal Receiver
This place is the part to receive the signal if it receivethe signal, you can hear the signal “beep. beep”.
There is a switch panel at inside of Front Panel.
At the time of operating, open the Front Panel.
Emergency switch can be used when the remotecontroller is lost or Testing.
Remote switch is usually used by remote controller.
Indoor Unit Display Switch Panel
ON (Red)
Lights when the
operation is going on.
Air clean (Green)
Timer (Yellow)
Lights during the time
reservation mode.
Quick (Red)Lights during the
time Quick
Mode.
Timer
Quick
Airclean
ON
EMERGENCY REMOTE
8/17/2019 AirCon Training Manual
55/175
55
Air Inlet (Side Back)
Connection Wire
Connecting Pipe
Drain Hose
Air Outlet
¡ DSA-151L, DSA-181L, DSB-181L/LH
(2) OUTDOOR UNIT
¡ DSB-070L/LH, DSB-091L/LH, DSB-151L/LH
AIR IN
AIR OUT
AC Cover
Remove cover to access the AC connectionfrom this unit to the indoor unit.
Connection Wire
Drain Hose
COPPER TUBING
Service ValvesThe indoor and outdoorunits are connected bycopper tubes which areconnected here.
Grounding ScrewGround the unit here.
Ground Wire (Not supplied)
8/17/2019 AirCon Training Manual
56/175
56
MODE
SLEEP
ON/OFF
TIMER
ENTER/ CANCEL
FAN SPEED
TURBO/MILD
Display
Displays information
pertaining to unit.
TURBO/MILD
Press to be colder the unit.
TIMER ENTER/CANCEL Button
Press to enter a timer setting or
to cancel timer setting
TIMER ON/OFF Button
Press to set the unit of or on time.
(0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8,
10, 12, 16, 20, 24hr)
MODE Button
Press to cycle through the modes
(Auto/Quick/Cooling/Fan/Dry)
SLEEP Button
Press to set the unit for
the sleep mode.
FAN DIR. Button
Press to select up/down
direction for fan.
FAN DIR. Button
Press to select left/right
direction for fan.
ON/OFF Button
Press to turn the unit
on or off.
TEMPERATURE Buttons
Press to raise or lower
the desired temperature.FAN SPEED Button
Press to select the fan speed
(High " ", Middle " ",
Low " ").
COVERSlide down to access most
of the remote buttons.
Slide down further to
access the battery
compartment.
AUTO
FAN DIR.
FAN DIR.
(3) EACH BUTTON OF REMOCON
8/17/2019 AirCon Training Manual
57/175
57
MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier)Lights to indicate the mode selected.
TIMER Indicators (Include sleep)Lights to indicate the timer function mode.
TEMPERATURE & RESERVATION TIME lndicatorLights to indicate the temperature or time.
FAN DIRECTION IndicatorsLights to indicate thefan direction.
NATURAL IndicatorLights to indicate thespeeds simulating a loreeze.
FAN IndicatorsLights to indicatethe fan speed.
AUTO
MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier/Heat)Lights to indicate the mode selected.
TIMER Indicators (Include sleep)Lights to indicate the timer function mode.
TEMPERATURE & RESERVATION TIME lndicatorLights to indicate the temperature or time.
FAN DIRECTION IndicatorsLights to indicate thefan direction.
NATURAL IndicatorLights to indicate thespeeds simulating a loreeze.
FAN IndicatorsLights to indicatethe fan speed.
AUTO
(4) REMOTE CONTROLLER DISPLAY
¡ DSB-070L, DSB-091L, DSB-121L
¡ DSB-070LH, DSB-091LH, DSB-121LH
MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier)Lights to indicate the mode selected.
TIMER Indicators (Include sleep)Lights to indicate the timer function mode.
TEMPERATURE & RESERVATION TIME lndicatorsLights to indicate th