AIR COOLED PACKAGEDAIR CONDITIONERS
Suitable for
factories
Page 15,16
Page 6Page 13,14
Page 15,16
1
Page 5Page 11
Page 5Page 12
Nice, cool air in the factory or in the cafeteria
2
DUCT CONNECTION TYPE
FLOOR STANDING TYPEDIRECT AIR BLOW TYPE
3
AIR COOLED PACKAGED AIR CONDITIONERS
DUCT TYPE
RUR10NY1FDR10NY1
RUR10NY1FVGR10NV1
RUR10NY1FVPGR10NY1
Enhanced varieties of factory modification and optional accesories
Standard model
Factory modification
Auto restart
Floor Standing Type
Fac
tory
Mod
ifica
ion
Direct Air Blow
DuctConnection
Type
Duct Type
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Central control adaptor kit (external terminal for ON/OFF , abnormal)1 DAT107A55
Opt
ion
–
Modify wiring for central control adapter kit (DAT107A55) installation
Change fan motor and pulley
Discharge grill plenum chamber
Side discharge grillon discharge plenum chamber
Lower drain pan
Front suction high efficiency filter chamber
Suction grill for front suction high efficiency filter chamber
Fresh air inlet
Rear suction
Drain pump
BRC1C62LCD remote controller2
DCS601C51intelligent Touch Controller2
DCS302CA61Central remote controller2
DCS301B61Unified ON/OFF controller3
DST301BA61Schedule timer3
KRCS01-1Remote sensor (thermistor for suction air)3
BRC1NU64Remote controller
Remote sensor(Thermistor for suction air)
All fresh air application
Low outdoor temp.15ºC application and long pipe 70m application
Front suction base flange for front suction high efficiency filter chamber
Contact sales for more infomation
Note: 1Wiring modification is needed on floor stand model to connect with central control ADP kit.2Need to use central control adapter kit for option connection.3Central control adapter kit and LCD remote controller is necessary for option connection.
Equipped with scroll compressor for quiet operation
Smooth running, low vibration, low operating sound.
Quiet Operation
Outdoor unitSound level
59 dB
380V 415V
RUR05NY1
59 dB
60 dB
60 dBRUR06NY1
4
DurabilityHeat exchange fins provided with anti-corrosion treatmentTo achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
(Applies to all outdoor units)
(Applies to RUR05N/06N)
Previous 20HP outdoor unit
Installation space is saved thanks to a more compact outdoor unit. This also makes it easier to install.
Space savings
RUG10AUY1 X 2RUR20NY1
(20HP)
NEW
2,560mm690mm
1,240mm765mm
space savedcompared to
previous model
53%
Refrigerant pre charged for up to 7.5 metres
Design flexibilityDesigned for long refrigerant piping. 50 m maximum length and 30 m maximum level difference to cover medium- and large-scale building needs.
Outdoor unit roof installation possible for plenty of leeway.
Allowable refrigerant pipe length and level difference
Max. leveldifference
Pre-charged 1 Max. length
30 m7.5 m 50 m(Equivalent length 70 m)
Note: 1Additional refrigerant charging is required if the refrigerant pipe is longer than the indicated length.
4-direction piping affords more freedom of layoutPiping can be run from the front, bottom, right or rear surface according to how the unit is installed.
In case of RUR08–20N, piping can be drawn out in two directions-front, and under side.
Max. length
Max. level difference
RUR05NY1-20NY1
Easy operationDigital remote control comes standard with indoor unit.
Temperature setting is possible by button operation. The set temperature is conveniently displayed on the LED.
1453
6789
210
1
2
3
5
6
7
89
Note.1
Note.1
4
1 Power
3 Temperature setting
2 Temperature scale
4 Mode setting
5 Next setting
6 Fan indicator lamp
7 Cool indicator lamp
9 Compressor 1 indicator lamp
10 Temperature sensor
8 Compressor 2 indicator lamp
1 On/Off button
3 Temp. setting up
2 Fan button
4 Temp. setting down
5 Mode button
6 LED display
7 Compressor operation lamp.
8 Fan operation lamp.
9 Cool operation lamp.
Note.1 It cannot be used for FVPGR10–20NY1
(Standard accessory)Floor standing type
(optional accessory)Duct type
X X
X X
X X
X X
X X
X X
X X
X X
X X X XX X
X X
5
X X
X X X X
X X X XX X X X
X X X X
X X X X
X X
6
X X
X X
X X
X X
7
Fan Performance
8
9
Wiring and Piping
10
DIMENSIONS
DIMENSIONS
11
12
DIMENSIONS
13
14
DIMENSIONS
15
16
When there are obstructions on the inlet side and both lateral sides
When there are obstructions on both sides
When there is an obstruction only on the inlet side
When there are obstructions on both sides
When there is an obstruction on the inlet side
When there are obstructions on the inlet side and both lateral sides
An obstruction in the overhead space
An obstruction in the overhead space
An obstruction in the overhead space
An obstruction in the overhead space
An obstruction in the overhead space
17
or more
or more
or moreor more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more
or more or more
mm
mm
or more
or more
or more
or more
or more
or more
or more
or more or more
or moreor more
or more
or more
or more
or more
or more
or more
or more
or more or moreor more or more
or more or more
or more
or more
or more
or more
or more
or more or more
or more
or more or more
18