Welcome to the 3-part series - NGS technology overview and applications
“Overview of NGS technologies and innovative NGS library prep methods”
Part 1: Introduction to next-generation sequencing (NGS) technology
Part 2: Innovative NGS library construction technology
Part 3: Advanced NGS library prep for challenging samples
Advanced NGS library prep for challenging samples
Sample to Insight
Legal disclaimer
• QIAGEN products shown here are intended for molecular biology
applications. These products are not intended for the diagnosis,
prevention or treatment of a disease.
• For up-to-date licensing information and product-specific
disclaimers, see the respective QIAGEN kit handbook or user
manual. QIAGEN kit handbooks and user manuals are available
at www.QIAGEN.com or can be requested from QIAGEN
Technical Services or your local distributor.
Advanced NGS library prep for challenging samples
Sample to Insight
Agenda
NGS library construction for challenging samples
Challenges
Technical solutions
Applications
Focus on cfDNA library construction
1
2
3
4
Advanced NGS library prep for challenging samples
Sample to Insight
Lower sequencing cost opens up NGS to more applications
Advanced NGS library prep for challenging samples
Sample to Insight
Advanced NGS library prep for challenging samples
NGS applications: is the only limit our imagination?
http://www.internationalgenome.org/http://www.uk10k.org/https://www.genomicsengland.co.uk/the-100000-genomes-project/https://www.icarbonx.com/en/https://www.technologyreview.com/s/534591/us-to-develop-dna-study-of-one-million-people/
More samples……
Sample to Insight
Advanced NGS library prep for challenging samples
NGS applications: is the only limit our imagination?
http://www.nasa.gov/mission_pages/station/research/news/dna_sequencinghttp://spaceflight101.com/iss/kelly-twins-study/http://www.nature.com/nrmicro/journal/v13/n7/full/nrmicro3509.htmlhttp://www.nature.com/nature/journal/vaop/ncurrent/full/nature19792.html
Different samples……
Sample to Insight
Demanding sequence information from challenging samples
Limitations in sample quantity and quality
Advanced NGS library prep for challenging samples
Sample to Insight
High genomic complexity of sub-nanogram samples
• 1 nanogram of DNA: • 1 ng/6 pg = ~350 human
haploid genomes
• Theoretical max unique sequence depth of ~350x
• 100 picogram of DNA: • >1000 bacterial cells
• ~15 human cells
• ~35 unique copies of the human haploid genome, in theory enough for 30x WGS
Standard low input NGS library prep 10–100 ng
Bacterium Mammalian cell
200 µl Blood
100 ng
10 ng
1 ng
0.1 ng
Typical Sample DNA
Many real-world samples still cannot meet NGS library prep kit requirements despite containing sufficient genomic complexity for many common analyses
ChIP-Seq, Ancient DNA,
LCM
cfDNA from 5 ml plasma
200 µl blood
Advanced NGS library prep for challenging samples
Sample to Insight
The challenge: as input decreases so does the fraction of useful data
Advanced NGS library prep for challenging samples
Challenging samples:
• Sample quantity
• Sample quality • Degradation • Modification
• Low sample-to-data conversion due to enzymatic inefficiency and loss during lab processing
• Lower than expected sequencing depth across challenging regions
• Low sequence data quality leading to lower % of mapped reads
• High % adapter contamination
Sample to Insight
Chemistry re-optimized for sub-nanogram samples
Advanced NGS library prep for challenging samples
QIAseq Ultralow Input Library Kits
Consistent conversion across a 10,000-fold input range
End polishing 25°C, 30 min65°C, 15 min
Ligation:25°C, 10 min
Cleanup
Minimal amplification
1 Tube
2 Reactions
70 Minutes
Up to 43 µl input volume to maximize dilute samples
Sample to Insight
QIAGEN Webinar 20160927
QIAseq Ultralow Input Library Kit: technical principles
End-polishing enzyme mix A unique mixture of 4 different enzymes for efficient end repair + A-addition in one reaction No interference with the ligation step
End-polishing buffer Balanced formulation for maximal activity of all 4 enzymes Additives that increase the effective concentration of the template DNA to ensure high rate of DNA:enzyme interactions even with minimal DNA input
Ligase High-purity DNA ligase, free of nuclease contamination
Ligation Buffer Additives to ensure high ligase activity by maintaining optimal conformation
Adapter Optimized adaptor modification and concentration to minimize adapter-dimer formation
Library amplification Proprietary high-fidelity PCR mix with minimal bias and high efficiency
Sample to Insight
QIAseq Ultralow Input Library Kit for as little as 10 –100 pg DNA
Advanced NGS library prep for challenging samples
• Ultra efficient enzymatic steps
• Minimal % adapter and even G/C coverage
• Ideal for samples limited in quantity and quality
• Flexible: optimized for sub-nanogram, but delivers excellent performance from 10 pg –100 ng +
Sample to Insight
Advanced NGS library prep for challenging samples
High quality library from low-input GIAB sample
High mapping rate, high conversion rate, high uniformity
Sample to Insight
Advanced NGS library prep for challenging samples
High SNP detection sensitivity and specificity from 1 ng GIAB
1 ng input GIAB DNA , SNP detection with WGS and WES
Sample to Insight
Sensitive mutation detection from minimal input amount
Advanced NGS library prep for challenging samples
Comprehensive coverage and high uniformity ensures sensitive mutation detection
cfDNA or FFPE reference20 ng each, Horizon Discovery
Library construction: QIAseq Ultralow Input Library Kit
(8 cycles PCR)
Target enrichment: xGen Pan Cancer Panel (IDT)
Post-capture amplification:
GeneRead Library Amp Kit
Sequencing: MiSeq®
Data analysis: CLC Biomedical Workbench
Sample to Insight
Advanced NGS library prep for challenging samples
Sensitive mutation detection from minimal input amount
Sensitive and accurate mutation detection with moderate sequencing depth
Sample to Insight
QIAseq UltraLow Input Library Kit for ChIP-seq
High correlation of normal vs. low input of ChIP DNA
6.9 ng ChIP DNA
0.69 ng ChIP DNA
Advanced NGS library prep for challenging samples
Sample to Insight
Advanced NGS library prep for challenging samples
Modified QIAseq Ultralow Input Libray Kit: protocol for WGBS library construction
Efficient WGBS library generation from bisulfite-treated DNA
*6 cycles of library PCR amplification
* For details see poster: Fast and Efficient Post-Bisulfite-Seq Library Construction with QIAseq Ultralow Input DNA Library Protocol on QIAGEN website
Sample to Insight
Advanced NGS library prep for challenging samples
Circulating cell-free DNA sequencing for NIPT and cancer detection
Sample to Insight
cfDNA sequencing: optimized sample and library preparation
Integrated workflow
cfDNA sample prep from plasma
End polishing
Adaptor ligation
Clean-up/adaptor removal
Library amplification PCR
NGS library
Based on gold standard QIAamp Technology
Based on QIAseq Ultralow Input Library Kit
Market-leading library amplification technology Optional depending on amount of starting material and intended application
PCR-free cfDNA library construction from 10 ng Input
Advanced NGS library prep for challenging samples
Sample to Insight
Advanced NGS library prep for challenging samples
Challenges in cell-free DNA library construction
Cell-free DNA poses special challenges for library construction
• Low amount of input DNA• 1-100 ng/ml plasma
• cfDNA amounts in plasma are highly variable • from person to person• different also depending on health status in the same person
• Small cfDNA size (majority ~170 bp)
Integrated sample and library prep protocols are required that work both with low-input DNA amount AND also with wide range of DNA input.
Sample to Insight
Robust performance over a broad range of input volumes
Evaluation of differernt plasma input volumes / cfDNA input in library prep
9.5 ng cfDNA from 5 ml plasma 5.7 ng cfDNA from 3 ml plasma
3.8ng cfDNA from 2ml plasma 1.9ng cfDNA from 1ml plasma
Library yield 139 nM in 25 µl Library yield 127 nM in 25 µl
Library yield 83 nM in 25 µl Library yield 59 nM in 25 µl
Advanced NGS library prep for challenging samples
Sample to Insight
Comparison of amplified vs. non-amplified cfDNA libraries
Library concentration from 10 ng cfDNA is sufficiently high for sequencing w/o amplification
8 PC
R cy
cles
Advanced NGS library prep for challenging samples
• 2 nM library concentration sufficient for whole genome sequencing
• For higher amounts of DNA libraries, PCR enrichment with limited number of cycles is required
Sample to Insight
Highly specifiic detection of trisomy 21 and 18
25
Highly specific and sensitive detection of trisomy 21 and 18 in NIPT reference samples
• NIPT reference samples (SeraCare SeraSeq™ Trisomy 21 and 18, 12% fetal cfDNA) were processed using the QIAseq cfDNA All-in-One Kit
• Coverage distributions of the two trisomy samples were normalized against each other
• Trisomy 21 and 18 clearly detectable from only 4-6 M reads
Overrepresented chr 18 in sample T18 (12%)
Overrepresented chr 21 in sample T21 (12%)
Sample to Insight
QIAseq cfDNA All-in-One Kits for the Ion Torrent™ platform
Advanced NGS library prep for challenging samples
cfDNA sample prep from plasma
End repair/adapter ligation/ nick repair(up to 56.5 µl cfDNA input)
Cleanup/adapter removal
Library amplification PCR
NGS library
1-step protocol 35 min
First one-step shot-gun library prep in market—QIAGEN Proprietary Technology .
Sample to Insight
Advanced NGS library prep for challenging samples
Donor #1
Donor #3
Donor #2
QIAseq cfDNA All-in-One Kits for the Ion Torrent platform
• Use 50 µl cfDNA sample in library prep
• Double size selection to generate libraries with narrow size distribution (optimized for Ion Torrent clonal amp)
Efficient construction of high quality DNA libraries
Sample to Insight
Performance comparison standard vs.1-step library prep protocol
QIAseq cfDNA All-in-One Kit: performance data for the Ion Torrent platform
2-step protocol
All-in-One protocol
Library yield
Libraries prepared from 5ng cfDNA
2-step protocol All-in-One protocol
Sequencing data: quality assessment
2-step protocol All-in-One protocol
No nucleotide bias at the beginning of reads
Comparable percentage of high quality bases
Advanced NGS library prep for challenging samples
Sample to Insight
Advanced NGS library prep for challenging samples
QIAseq NGS solutions
For more information, visit the QIAGEN website: www.qiagen.com/us/products/ngs/next-gen-sequencing/
Sample to Insight
Questions?
Thank you for attending!
All our solutions from Sample to Insight on:QIAGEN.com
Contact QIAGEN Technical ServiceCall: 1-800-426-8157 for US
Call: +49 2103-29-12400 EU
Email: techservice-na@QIAGEN.com
techservice-eu@QIAGEN.com
QIASeq.NGS@QIAGEN.com
QIAwebinars@QIAGEN.com
Advanced NGS library prep for challenging samples