Post on 15-Mar-2021
STUDIO OFFICE
CD
06.10.201918-223-HOTCHKISS
JOHN HOTCHKISSCOMMERCIAL OFFICE
2290, 2294 OLDRANCH RDCOLORADO SPRINGS
FLOOR PLAN1/4" = 1'-0"1
DATE:
PHASE:
DRAWN BY:
AFFINITYENGINEERING
1887 E. Belleview Avenue,Suite 1100
Englewood, Colorado 80111Telephone: 303-228-2256
info@Affinity-Engineering.com
SHEET:
JOB NO:
A2.1
FLOOR PLAN & RCP
RLK
ROOF PLAN1/4" = 1'-0"2
REFLECTED CEILING PLAN1/4" = 1'-0"3
LEGEND
BUILDING PLANNOTES
KEYNOTES
LEGEND
C
DC
U
L
F/L
WS
ROOF VENTILATION
COP
C
B
D
2 5 6
E
31
A
4
SUITE 100 SUITE 150HALLWAY
LOBBY
MECH
LU/LA
MEN
WOMEN
JAN
CD
06.10.201918-223-HOTCHKISS
JOHN HOTCHKISSCOMMERCIAL OFFICE
2290, 2294 OLDRANCH RDCOLORADO SPRINGS
FIRST FLOOR PLAN1/4" = 1'-0"1
DATE:
PHASE:
DRAWN BY:
AFFINITYENGINEERING
1887 E. Belleview Avenue,Suite 1100
Englewood, Colorado 80111Telephone: 303-228-2256
info@Affinity-Engineering.com
SHEET:
JOB NO:
A2.2
FIRST FLOOR PLAN
RLK
LEGEND
BUILDING PLANNOTESKEYNOTES
COP
C
B
D
2 5 6
E
31
A
4
SUITE 200 SUITE 250
HALLWAY
MECH
LULA
UNISEX
JAN
DECKDECK
DECK
DECK
CD
06.10.201918-223-HOTCHKISS
JOHN HOTCHKISSCOMMERCIAL OFFICE
2290, 2294 OLDRANCH RDCOLORADO SPRINGS
SECOND FLOOR PLAN1/4" = 1'-0"1
DATE:
PHASE:
DRAWN BY:
AFFINITYENGINEERING
1887 E. Belleview Avenue,Suite 1100
Englewood, Colorado 80111Telephone: 303-228-2256
info@Affinity-Engineering.com
SHEET:
JOB NO:
A2.3
SECOND FLOOR PLAN
RLK
LEGEND
BUILDING PLANNOTESKEYNOTES
COP
C
B
D
2 5 6
E
31
A
4
CD
06.10.201918-223-HOTCHKISS
JOHN HOTCHKISSCOMMERCIAL OFFICE
2290, 2294 OLDRANCH RDCOLORADO SPRINGS
FIRST FLOOR REFLECTED CEILING PLAN1/4" = 1'-0"1
DATE:
PHASE:
DRAWN BY:
AFFINITYENGINEERING
1887 E. Belleview Avenue,Suite 1100
Englewood, Colorado 80111Telephone: 303-228-2256
info@Affinity-Engineering.com
SHEET:
JOB NO:
A2.4
FIRST FLOOR RCP
RLK
LEGEND
C
DC
U
L
F/L
WS
COP
C
B
D
2 5 6
E
31
A
4
CD
06.10.201918-223-HOTCHKISS
JOHN HOTCHKISSCOMMERCIAL OFFICE
2290, 2294 OLDRANCH RDCOLORADO SPRINGS
SECOND FLOOR REFLECTED CEILING PLAN1/4" = 1'-0"1
DATE:
PHASE:
DRAWN BY:
AFFINITYENGINEERING
1887 E. Belleview Avenue,Suite 1100
Englewood, Colorado 80111Telephone: 303-228-2256
info@Affinity-Engineering.com
SHEET:
JOB NO:
A2.5
SECOND FLOOR RCP
RLK
LEGEND
C
DC
U
L
F/L
WS
C
B
D
2 5 6
E
31
A
4
CD
06.10.201918-223-HOTCHKISS
JOHN HOTCHKISSCOMMERCIAL OFFICE
2290, 2294 OLDRANCH RDCOLORADO SPRINGS
ROOF PLAN1/4" = 1'-0"1
DATE:
PHASE:
DRAWN BY:
AFFINITYENGINEERING
1887 E. Belleview Avenue,Suite 1100
Englewood, Colorado 80111Telephone: 303-228-2256
info@Affinity-Engineering.com
SHEET:
JOB NO:
A2.6
ROOF PLAN
RLK
ROOF VENTILATION
ROOF PLAN NOTES