560-287-DI-E-105

Post on 03-Oct-2015

7 views 4 download

description

560-287-DI-E-105

Transcript of 560-287-DI-E-105

  • - AUTO/MANUAL

    B11 B12

    B21 B22

    DI1

    DI2

    DI3

    DI4

    DI5

    DI6

    DIIL

    X22/1

    DGND1X22/9

    DGND2X22/10

    B11 B12B11 B12

    1

    7

    6

    4

    5

    8

    9

    12

    11

    10

    L1

    L2

    L3

    T1

    T2

    T3

    U2

    V2

    W2

    (U2)

    (V2)

    (W2)

    Sh

    KW

    KW

    U2

    V2

    W2

    (U2)

    (V2)

    (W2)

    (11)

    U1

    V1

    W1

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    27

    28

    29

    30

    31

    32

    33

    34

    35

    RDIO-01

    X22/2

    X22/3

    X22/4

    X22/5

    X22/6

    X22/11

    1,5

    EMERGENCYSTOP

    1,5

    SPARE

    EMERGENCYSTOP

    LOCAL CONTROL STATION

    (NOTE 2)

    3 Ph

    60 Hz

    INPUT

    OUTPUT

    NOTES:

    1

    2

    3

    4

    - EMERGENCY STOP

    - START VF- STOP VF

    - SET POINT SPEED ADJUST

    - LOCAL/REMOTE SELECTION

    - SPEED FEEDBACK

    - DRIVE READY- RUNNING- DRIVE FAULT- MOTOR CURRENT- MOTOR VOLTAGE

    - ENERGIZED

    TABLE N^1

    (8)

    B21 B22

    (4)

    (5)

    SELECTOR

    REMOTE

    SELECTOR

    LOCAL

    (8)

    (11)

    (4)

    SPARE33 34

    (N^)

    LEGEND

    : MC POWER TERMINAL

    : MOTOR POWER TERMINAL

    : INDICATE DESIGNATION NUMBER OF CONDUCTOR

    : TERMINAL IN DEVICE LOCATED IN THE FIELD

    : 24 Vdc & 120 Vac DIGITAL INPUT

    : VARIABLE FREQUENCY DRIVE TERMINAL

    380 V

    VARIABLE FREQUENCY DRIVE

    : 120 Vac DIGITAL OUTPUT

    CONTACTOR FILTERDISCONNECT

    SWITCH - CB

    CONTROL CIRCUIT

    1.- THE COMMUNICATION CABLE BETWEEN THE DRIVE AND THE PROJECT S PAS (PROCESS AUTOMATION SYSTEM) HAS CAPABILITY TO MONITOR AND CONTROL THE DRIVE SPEED.

    SIGNALS TO BE TRANSMITTED VIA SERIAL COMUNICATIONPROFIBUS DP TO PAS (PROCESS AUTOMATION SYSTEM)

    A.- SIGNALS FROM CONTROL SYSTEM PAS TO VF

    - PREDETERMINED SPEED

    B.- SIGNALS FROM VF TO CONTROL SYSTEM PAS

    C.- FROM LOCAL CONTROL STATION IN FIELD TO VF

    - SELECTOR LOCAL/REMOTE

    LOCREM

    X

    X(4)

    (5)

    SELECTOR

    C22C11

    C33

    LOCREM

    X

    X

    C22C11

    C33

    SELECTOR

    - RUNNING TIME

    FILTER

    AC DCLINK INVESTORCONVERTER

    FREQUENCY CONVERTERUNIT

    COMMUNICATIONUNIT

    PROFIBUS-DP

    1

    3

    5

    2

    4

    6

    1

    3

    5

    2

    4

    6

    K01Q0120A

    X21/2

    1

    R2

    3

    24Vdc X23/1

    X25/2

    X26/2

    X27/2

    X25/3

    X26/3

    X27/3

    X23/2

    GND0

    READY

    RUNNING

    FAULT

    X22/2

    X21/3

    X11/1

    X11/2

    X22/3

    DI1

    R01X80/4

    X80/3

    X80/1

    X80/2

    DRIVE

    SPARE

    RUNNING

    13 13 14 43 44 A1 A2K01

    R CSUP

    K01

    S05

    Q01

    K01

    15

    16

    (13)

    FROM 24 DCPOWER SUPPLY

    F02

    21

    22

    12

    11

    10

    6

    5

    F02A50A2A

    F0250A2A

    F02

    50A2A

    2 4

    1 3

    X11/0

    +24VdcX34/2

    GND

    X34/3

    X22/7

    X22/8

    +24Vdc

    +24Vdc

    G

    Y

    A1

    B1

    A2

    B2

    S

    PROFIBUS-DPCOMMUNICATION CABLE

    CONNECTED TO OTHER DEVICE IN MC(BY INSTRUMENTATION)

    AVAILABLE

    CDP 312RCONTROL PANEL

    X39/1

    PE PE PE

    AN

    AL

    OG

    IN

    PU

    T A

    ND

    OU

    TP

    UT

    A1

    B1

    A2

    B2

    S

    GREEN

    RED

    GREEN

    RED

    SHIELD

    X80

    12

    22

    15

    21

    13

    14

    16

    20

    X10.1

    10

    11

    (13)

    (5)

    (12)

    (-)(+)

    24 Vdc

    PE(PE)

    : MC TERMINAL

    (13)

    (12)

    Q01

    R02 (IMPULSE)

    20

    (12)

    14

    (8)(11)

    RP

    BA

    -01

    X21

    PE (PE)

    T1 (U2)

    T2 (V2)

    T3 (W2)

    SPARE7 8S05

    (BEHIND THE

    13

    14

    C NO

    AI

    2

    3

    AO

    LOCAL CONTROL STATION

    PE

    287CK110M1-LS

    287CK110M1-VF287CK110M1-LS

    287CK110M1-VF

    287CK110M1-VF

    BLUE DOOR )

    T02400/120V

    +/-5%;+/-2,5%200 VA

    TEST 1 2

    2.- CONNECTION DIRECTLY TO GROUNDING GRID ONLY IN HAZARDOUS AREAS.

    23-0

    7-2

    012

    q:\

    share

    d\r

    0534200\0

    2_eng_dw

    g\0

    7_ele

    \02_in

    t_app\d

    iagra

    mas e

    squem

    ati

    cos\5

    60-2

    87-D

    I-E

    -105.d

    gn

    11:5

    4:2

    9

    candiaf

    0

    TOROMOCHO PROJECT

    C-560PROJECT :REV

    MINERA CHINALCO PERU S.A.

    DRAWING N^:

    TITLE:

    REV.DRAW APPROVED BY

    FCT GBO GRO560-287-DI-E-105

    CLIENT/PROJECT:

    No

    RE

    VIS

    ION

    S

    DESCRIPTION

    0

    DATE

    ISSUED FOR CONSTRUCTION

    287CK110M1-C01

    287CK110M1-D01

    287CK110M1-M01

    17/07/12

    LV SCHEMATICS DIAGRAM287-CK-110-M1

    COOLER

    287-CK-110-M1

    287-CK-110-M1

    (NOTE 3)

    3.- LOCAL CONTROL STATION SHALL BE PROVIDED WITH SEPARATOR FOR DIFFERENT VOLTAGE LEVELS.

    280-MC-006A

    280-MC-006A

    ADM CALCINER MOLYBDIC OXIDE