3g Flexi Wcdma Flexi Multi Radio Bts Ppt

Post on 12-May-2017

379 views 65 download

Transcript of 3g Flexi Wcdma Flexi Multi Radio Bts Ppt

3G Flexi WCDMA BTS, Overview, Installation, Commissioning & Integration.

Nokia Siemens Networks Flexi WCDMA BTS OVERVIEW

New way to build your 3G network

• Fits Nokia UltraSite EDGE BTS cabinet – easier site acquisition

• Faster, more economic roll-out

• Modularity with OBSAI - the future proof multi-radio BTS architecture

• Up to 60% lower energy consumption

Fits practically anywhere

• Small size and light weight

• A few module types can meet all site needs

New level of environmental performance

• Less BTS sites required

• Superior energy efficiency

• Safe use of material

Wall installation Pole installation Pile/Floor installation

Multimode Nokia UltraSite

EDGE BTS & 19” rack Installation

Nokia Flexi WCDMA Base Station Revolutionary site concept

Wide Area high capacity WCDMA/HSPA BTS

in micro BTS size

• Up to 12 carriers, 6 sectors

• Typical 43W output power

• Remote channel capacity upgrade and HSPA activation

Modular structure enables flexible expansions

– Radio and System modules as building blocks

– Optional AC Power supply & back-up and Transmission Hub module

Optimized Antenna Line

• Integrated power feed and control for Mast Head Amplifier and Antenna Tilt

133mm (3U)

447mm (19” rack)

Less than 21kg

Outdoor –33 to + 55C, IP55

422/560 mm

2+2+2 BTS

Less than 63kg

Nokia Flexi WCDMA Base Station Small and Modular

Modular BTS, installation options

For indoor/outdoor use > IP 55

Installation options:

Floor

Wall, Multiple units on wall

Rack

Stand or pole

Cabinet

Feederless (RAS05.1: 190 m / later: 15km)

Nokia Flexi WCDMA BTS tackles site related costs

OPEX

• Power

• Site rent

• Remote capacity

provisioning

CAPEX

• Site implementation

• Site construction

• Transmission

• Antenna system

• Power system

How much can you save?

Air

conditioning

4 k€

Equipment

Room

8 k€

Shelter

14 k€

Antenna Line

1 - 30 k€

Nokia Flexi WCDMA BTS Improved BTS Site CAPEX and IMPEX

Shelter / equipment room can be avoided by outdoor BTS installation. Modular, small and light BTS minimizes also required civil work cost

Antenna line civil work and component cost can be minimized by locating BTS close to the antennas (maximizes also cell capacity)

In indoor installations additional air conditioning is not needed due to low power consumption

RF Module

Optional Front and

Back covers

Antenna 1Antenna 2

Antenna 4

Antenna 3

Antenna 1Antenna 2

Antenna 4

Antenna 3

External Interfaces of RF Module (Figure without the Casing)

RF Module Variants

RF Module variants supported in WN3.2

• FRGC: Flexi RF Module 2.1 GHz, Dual 50 W FRGD: Flexi RF Module 2.1 GHz, Single 50 W

• FRIA: Flexi RF Module 1.7/2.1 GHz, Dual 50 W FRIB: Flexi RF Module 1.7/2.1 GHz, Single 50 W

RF Module variants supported in WN3.3

• FRCA: Flexi RF Module 850 MHz, Dual 50 W FRCB: Flexi RF Module 850 MHz, Single 50 W

• FRDA: Flexi RF Module 900 MHz, Dual 50 W FRDB: Flexi RF Module 900 MHz, Single 50 W

• FREA: Flexi RF Module 1700 & 1800 MHz, Dual 50 W

FREB: Flexi RF Module 1700 & 1800 MHz, Single 50 W

• FRFA: Flexi RF Module 1900 MHz, Dual 50 W FRFB: Flexi RF Module 1900 MHz, Single 50 W

RF module Tx and Rx antenna connectors (WBTS5.0)

Ant 1 Ant 2

Tx and Rx Rx

Ant 1 Ant 2

Tx and Rx Rx

Ant 4 Ant 3

Tx and Rx Rx

FRxB/D Tx and Rx antenna connectors (Single PA = one pipe-PA)

FRxA/C Tx and Rx antenna connectors (Dual PA = two pipe-PA) Rx Rx Rx

Tx

&

Rx

Tx

&

Rx

Tx

&

Rx

Ant6 Ant5 Ant4 Ant3 Ant2 Ant1

FRxx Tx and Rx antenna connectors (Triple PA = three pipe-PA)

Flexi System Module + Transport sub-module

System module

FCM

TRS

SubModule

BB Extension I/F

SUM &

MUX

WSPC WSPC FSP

Control MCU

+ Clock gen.

EAC, Clock I/O, Eth

Power

Distribution

Assembly

Power supply module is responsible for the

distribution of 48VDC throughout the BTS

Transmission sub module

for termination of the

BTS transmission

Control and Clock generation unit and the EAC, clock I/O ethernet

distribution interface

Baseband Extension interface

to second system module

Summing and Multiplexing unit and up to three signal processing sub

assemblies (FSPA’s). The signal processing units are similar to the

WSPC unit

Three Optical Interface units for RF module interfacing

RF Mod

I/F

RF Mod

I/F

RF Mod

I/F

• Two hardware versions of the system module are available

•FSMA – has only one FSPA unit and a processing capacity of 64 channel elements

•FSMB – has three FSPA’s and a processing capacity of 192 channel elements

• The units are identical except that the extension module does not require the transmission module

• In extension mode only the baseband processing capacity of the extension module is used

System module - Release 2 • Core assembly (new parts in blue)

– 1xFCMD Clock & Control sub-assembly

– 1-3xFSPC BB sub-assembly

– Core mechanics sub-assembly

– 1xFPFB power sub-assembly

– 1xFAN sub-assembly (same as rel1)

– Connection cards (same as rel1 – except FPF-FCM connection card)

• 1xCasing: (same as rel1)

• 1xFTM: Transmission module (rel1 FTM is compatible)

– New FTM is developed for WBTS5.0 (not in SM2 program scope)

Three SM R2 variants supported:

• FSMC, 1 FSPC, 216 CE (WBTS5.0)

• FSMD, 2 FSPC, 432 CE (WBTS5.0)

• FSME, 3 FSPC, 648 CE (tentatively in WBTS5.0)

Compatibility

• FCMD, FSPC and core mechanics is not SM1 compatible

• SM1 re-used parts, FPFB and FTM is SM1 compatible

• SM2 is compatible with RFM1 and RFM2

• SM2 HW is LTE capable – same HW for LTE 1.0 SW release

System Module R2 (FSMC/D/E)

FSMC/D/E Y** and product contains

FCMD/FSPC

(FSMC/D/E X** old protos contain FCMC/FSPB)

FlexiTransport Overview

FTPB (RAS05.1)

FTEB (RAS05.1)

FTJA (RAS06)

FTOA (RAS05.1ED

FTIA (RAS05.1) FTFA (RAS05.1)

Module name Interfaces Availability Remarks

FTPB 8xE1/T1/JT1 RAS05.1 120/110/100Ω, RJ48c

FTEB 8xE1 coaxial RAS05.1 75Ω, SMB

FTOA 1xSTM1/OC3 RAS05.1 ED 1xSFP, LC equipped

FTFA 2xFlexbus RAS05.1 TNC

FTIA 4xE1/T1/JT1

2xFast Ethernet, 1xGE

RAS05.1

Ethernet supported in RAS06

Optional Gigabit Ethernet interface (SFP)

RJ48C, RJ45, SFP (LC)

FTJA 4xE1 coaxial

2xFast Ethernet, 1xGE RAS06

Optional Gigabit Ethernet interface (SFP)

SMB, RJ45, SFP (LC)

Transport Sub-modules

Flexi Power Module FPMA

Example configuration with:

1 x Flexi Power Module FPMA

• 3 Flexi Power AC/DC sub-modules FPAA (230VAC -> 48VDC)

• 1 Flexi Power Battery FPBA

+

-

48VDC

output to

BTS

AC input

cabling

to FPMA

AC feed to

FPAA

(3pcs)

OBSAI Interface

OBSAI Interface

Transmission Transport

OB

SA

I Inte

rfac

e

Nokia Flexi WCDMA Base Station Modularity is the key

Modularity with open OBSAI compatible interfaces enables Faster time to market Economies of scale Future proofness

Processing Base band

OBSAI Interface Radio RF

OBSAI Interface Co

ntro

l

Source: OBSAI

OBSAI reference architecture

OBSAI is multistandard (WCDMA/FDD, WCDMA/TDD, GSM/EDGE, …)

• RP1: Clocks & Synchronization + Ethernet (control/management)

• RP2: 100M or 1Gbit Ethernet (physically same as RP1 c/m)

• RP3: OBSAI specified protocol, 768/1536/3072Mbps ) serial bus 8B/10B encoded with embedded clock. Frame structure optimized for air interfaces

• 48V power supply for all blocks/units

System module

FP

F

FT

M

FS

P

FC

M

FC

M

FC

M

HW Unit comparison between platforms

RF modules:

• FRxy Flexi RF Module Dual 50 W

• FRxy Flexi RF Module Single 50 W • Frequency variant (x):

C = 850, D= 900, E =1700 or 1800, F = 1900, G=2100, I = 1700/2100

• Number of carriers per RF module (y): A = 2 carriers, dual 50W B = 1 carrier, single 50W C = 2 carriers, dual 50W / 2100 D = 1 carrier, single 50W / 2100

• WAFA/B/I/J/H/G/M/N/T/W

• WPAI/J/C/D/H/K/M, WMPA/C/M

• WTRB/C/D/G

• WICA, WOCA/C

• WFCA/B/C/D, WUCM/A/B

• Bias-T

System modules: Baseband units:

• FSMA System module 1 FSP

• FSMB System module 3 FSP

• WAMA, WSMB, WSCA, WSPC, WMCM, WPSE

Transmission sub-modules: Transmission units:

• FTOA, FTPB, FTEB, FTFA, FTIA, FTJA • AXUA/B, AXCC/D, IFUA, IFUC, IFUD, IFUE, IFUF

Nokia Flexi WCDMA BTS Nokia UltraSite/MetroSite(50) WCDMA BTS

Nokia Flexi WCDMA BTS Build Up by Modules

Optional Outdoor cabinet

BTS System

Module

Two PA RF Module

Two PA RF Module

Two PA RF Module

Optional

Extension System

Module (RAS05.1 ED)

AC-> DC BBU AC

(Optional)

SYSTEM MODULE:

- C-plane processing

+ centralised timing

- U-plane processing

+ multiplexing & summing

- Ethernet switching

- Transport processing

- External interfaces

- Power Distribution

RF MODULE:

- Modulator

- Channelizer

- Analog RF processig

- Power Amplifier

(integr.)

- Antenna filter (integr.)

Optical interfaces between

the modules

2x50 W RF Module

50 W RF Module

Sector 1

Sector 2

Sector 3

Site upgrade path to 2+2+2 (2nd of 2)

Cost Optimized Configuration COC (WN3.3)

30 W

PA TX

1

TX1 & RX1

Div RX1

1+1+1 @ 20 W

30 W

PA

Sector 1

30 W

PA TX

1

TX

3

Sector 2

Sector 3 TX1 & RX1

Div RX1

TX1 & RX1

Div RX1

50 W

PA

1+1+1 @ 40 W

40 W SW Licence

50 W

PA

50 W

PA

TX

2

TX

4

TX

2

2+2+2 @ 20 W

• 40W Power Licence +

• 2nd Carrier SW

Licence (RAS06)

• 1+1+1 @ 20/40 W

-> 2+2+2 @ 20 W

with minimum 3-sector RF Module

configuration

• 2 x 50 W RF Module

• 50 W RF Module

• the same RF cabling

• no site visits

• Tx/Rx Carrier Centre Frequency Spacing =

5MHz

BTS System

Module

50 W

PA TX

1

Carrier TX1

RX1

Div RX1 1+1+1 @ 40 W 50 W

PA

Div RX2

Carrier TX2

RX2

2+2+2 @ 40 W 40W Power License

TX

3

3+3+3 @ 2x20

1x40 W (WN5.0)

& TX3

& RX3

& RX3

TX

2

BTS System

Module

2x50 W RF Module

2x50W RF Module

2x50 W RF Module

Sector 1

Sector 2

Sector 3

Sector 1 (2 and 3 identical)

Capacity upgrade path to 4+4+4 (2nd of 2)

Upgrade Optimized Configuration UOC (WN5.0)

Optional BB Extension

System Module

• 1+1+1 @ 20/40 W

-> 2+2+2 @ 20/40 W

-> 3+3+3 @ 20 W

-> 4+4+4 @ 20 W

• with minimum 3-sector RF Module

configuration

• three 2 x 50 W RF Modules

• the same RF cabling

→ no site visits

• Tx/Rx Carriers 1…4 inside 20 MHz sub-

band

& RX4

& TX4

& RX4

4+4+4 @ 20 W

• 40W Power License

+

•2nd Carrier License

(WN5.0)

TX

4

Nokia Siemens Networks Flexi WCDMA BTS Installation

Objectives

After the completion of this chapter, the participant will be able to:

• Examine a Nokia Siemens Flexi WCDMA BTS for correct installation

Work Order

Handling the modules and unpacking the

delivery

Preparing the modules for installation

Installing the stand-alone BTS on the floor

Fixing adapter mechanics to plinth

Mounting the stand-alone BTS on the wall

Mounting the stand-alone BTS on the pole

Installing modules inside Nokia cabinet

Installing optional modules

Installing transmission sub-module

Grounding the BTS

Connecting external power feed

Handling the Modules and unpacking delivery

ESD ANTI-STATIC WRIST STRAPS SHOULD BE WORN WHEN HANDLING ANY UNIT WHICH DISPLAYS THE ESD

LOGO

When handling the modules, always use the antistatic wrist strap as shown in the Connecting the antistatic wrist strap figure below. The cabinet must be grounded, otherwise the antistatic wrist strap will not work. Refer to Grounding the BTS section.

After mounting the Plinth,

attach the site ground.

Handling the Modules and unpacking delivery

Unpack and check the delivery System Module

System Module

Front and Rear covers

External Cable Entry

Front and Rear covers

External Cable Entry RF Module

Unpack and check the delivery RF Module

Preparing the modules for installation Rear Cover

Fix the module back cover with two screws.

Preparing the modules for installation External Cable Entry

Fix the two external cable entries with

four screws.

Supported Configurations

Clearances

Anchoring the plinth on the floor

Without maintenance Space With maintenance Space

Recommended installation order

Check that the plinth is installed

correctly.

Actual stacking

configuration may vary

Installing modules on the floor

Installation example: modules on the floor

Fixing adapter mechanics to plinth

Adapter mechanics brackets are installed on the plinth in wall and pole installations

Mounting the stand-alone BTS on the wall

A plinth is required

for mounting the

modules on a wall

Check that the plinth

adapter mechanics

are installed as

instructed in Fixing

adapter mechanics

to plinth section.

Mounting a second plinth on the wall

Mounting the modules on a wall

One mounting plinth per two modules is

installed on a wall. Refer to

Mounting the plinth on a wall for plinth

installation instructions.

Mounting the stand-alone BTS on the pole

NOTE: There are different

lengths of bolts and places

for bolts in the bracket.

Mounting the plinth on a pole

Recommended module installation order

• Do not install more than

two modules per plinth

• The modules must be

installed with front panels

facing left or right. Do not

install modules so that the

front panels face up or

down.

Mounting the modules on the wall or pole

1 Tip

Line up the locating marks in

the module to help aligning

the holes with fixing studs.

4 Tip

Use the markings in the

module to help aligning the

holes with fixing studs.

Installing modules inside Nokia cabinet

690

1260

Front view

14U

14U

5U

5U

Flexi Outdoor Cabinet FCOA Flexi Indoor Cabinet FCIA

Installing optional modules

Flexi power module (FPMA) consists of connector blocks and four slots for

AC/ DC sub-module (FPAA) or battery sub-module (FPBA).

FPMA can include:

. two FPAAs and two FPBAs

. three FPAAs and one FPBA

. one FPAA and three FPBAs

. one FPAA and three free slots for expansion.

Grounding the BTS

When modules are installed inside a cabinet, separate module grounding is not required.

If the BTS has more than one plinth (for example in wall or pole installations), connect the main ground to one of the plinths and ground all the modules to that plinth.

Nokia Siemens Networks Flexi WCDMA BTS Commissioning & Integration

What should be do before Commissiong & integration? What should I have befor Commissioning?

Note

Note

Note

Note

Note

Note

Note

Note

Note

Note

Note

Note

Note

Note

Note

Note

Note

Note

Note

Note

Tests Calls