2.3 Control valve schedule

Post on 16-Nov-2014

330 views 2 download

Transcript of 2.3 Control valve schedule

LEGENDNOTE 1 VALVE PORT NOTE 2 MATERIAL NOTE 3 ACTIONE : EQUAL PECENTAGE 1 : SUS304 C : CLOSE ON AIR FAILUREL : LINEAR 2 : SUS316 O : OPEN ON AIR FAILUREO : ON-OFF 3 : MONEL F : FREE ON AIR FAILURES : GLOBE TYPE 4 : NICKEL RO : OPEN WHEN SOLENOID

(SINGLE SEATED) 5 : STELLITED VALVE IS ENERGIZINGD : GLOBE TYPE 6 : CARBON STEEL RC : CLOSE WHEN SOLENOID

(DOUBLE OR CAGE) 7 : CAST IRON VALVE IS ENERGIZINGA : ANGLE TYPE 8 : HASTELLOYT : SAUNDERS TYPE 9 : GLASSX : BUTTERFLY TYPE 10 : TEFLONB : BALL TYPE 11 : BRONZEG : GATE TYPE 12 : SCS13EC : ECCENTRIC TYPE 13 : SCS316L NOTE 4 ACCESSORIESY : Y SHAPE TYPE 14 : SPECIAL REINFORCED TEFLON SEAT A : PNEUMATIC VALVE POSITIONERV : V BALL TYPE 15 : RUBBER B : ELECTRONIC VALVE POSITIONER(EX. PROOF TYPE)

16 : NEOPRENE F : AIR COOLING FINK : EXTENSION(FOR LOW TEMP.)H : WITH HAND WHEELT : BELLOWS SEALW(O) : LIMIT SWITCH FOR OPEN(EX. PROOF TYPE) W(C) : LIMIT SWITCH FOR CLOSE(EX. PROOF TYPE)R : SOLENOID VALVE(4 WAY OR 3 WAY EXPLOSION PROOF)

90,000 MTPY PVC PLANT IN VIETNAMTPC VINA PLASTIC & CHEMICAL CORP., LTD.

THAIPLASTIC AND CHEMICAL PUBLIC CO RAYONG FACTORYPROJECT TPC VINA LINE-2 PROJECT NAME CONTROL VALVE SCHEDULESCALE JOB NO.

B ### ISSUE FOR REVIEW Akachai K.Akachai K.Paisarn S. NONE EN07001A 7/8/2007 B.E.P ISSUE Akachai K.Akachai K.Paisarn S.DWG NO. SPX-30-A004REV. DATE DESCRIPTION DWG CHK. APP.

LEGEND

90,000 MTPY PVC PLANT IN VIETNAMTPC VINA PLASTIC & CHEMICAL CORP., LTD.

THAIPLASTIC AND CHEMICAL PUBLIC CO RAYONG FACTORY

TPC VINA LINE-2 PROJECT

CONTROL VALVE SCHEDULE

EN07001

SPX-30-A004 REV.B

Page 3 of 26

TPC VINA PLASTIC AND CHEMICAL CORP.,LTDCONTROL VALVE SCHEDULE

PVC LINE 2 PROJECT

TAG NO.

Data from file : PV4 Instrument R29 Operating Condition SpecificationPVC-4 LIQ Press. Nor.Rate Max.Rate Vapor Input Cv Size

Rating

Port Mat'l Action Acces- LineTag no. Service No. Fluid STM Up P Temp. L:kg/h L:kg/h Density M.W. Signal Cal. (inch) Type (Note 2) sories Size M'F'R

Or Stream S:kg/h S:kg/h (kg/m3) Visc. Select Body (Note 1) Body (Note 3) (Note 4) Spec.

GAS G:Nm3/h G:Nm3/h (C.P.) Port TrimFCV-316A/B-1 EA-301A/B 2 CW L 4 0.5 30 629000 700000 1000 1.0 I/P 1161 10 JIS X SCPH2 O B.H 10

INLET 3443 10 WAFER E 1 A1S

FCV-404 FCV-403 DA-401A/B/C 1 RVCM L 5.5 0.3 40 1712.49 1969 872 0.18 I/P 1 1/2 JIS E SCPH2 C B 2 M.SFEED 24 1 1/2 20K RF 2 B2J

FCV-501 DA-501 1 PS SLURRY 6.5 0.2 60 35,747 41,109 1100 1.95 I/P 102.3 3 ANSI EC A351CF8 C B 3 Y.KPS FEED 150 3 150 RF E SCS14 A3J

FCV-503 DA-501 1 LS S 7 1 164 1977 2,965 3.67 0.014 I/P 44.51 3 JIS S SCS13A C B 4 Y.Krecheck sizing INLET 115 3 10K RF E SUS316L A3K-H

FCV-511 FF-501 1 HW L 3.5 0.5 95 150000 264000 1000 I/P 486.9 8 JIS S A216WCB C B 8 M.SINLET 700 8 10K RF E SUS316 A1S-H

FCV-506A/B GF-501A/B 2 PS SLURRY 3 0.5 75 39674 45,626 1100 1.95 I/P 71.82 3 JIS EC SCS13A C B 3INLET 150 3 10K RF E SCS14 A1K-P

FCV-907 GA-9320A/B/C/D/E 1 CW L 4 0.5 30 400,000 400,000 1000 1.0 I/P 704.7 8 JIS 10K EC A216WCB C B.H 10 Y.KBY PASS 1000 8 WAFER E SCS14 A1S

LCV-201 LCV-201 FA-201 1 PW L 3 0.5 AMB 11,057 12,716 1000 1.0 I/P 2 1/2 JIS E 12 C B 4 M.SLNLET 81 2 1/2 10K RF 2 A20P

LCV-302 LCV-302 FA-303 TO 1 WW L 3.5 0.5 40 280 322 1000 1.0 I/P 1 JIS E SCPH2 C B.R 1 M.SFA-804 3 3/8 10K RF 2 A5S

LCV-303 FA-305 1 WW L 5 0.5 AMB 1,024 1,178 1000 1.0 I/P 1.95 1 ANSI S A216WCB C B 1 1/26.3 150 RF E SUS316L A5S

LCV-306 LCV-303 FA-308 1 IW L 6 0.5 AMB 12000 1000 1.0 I/P 2 JIS E 12 C A 2 M.S30 1 1/2 10K RF 2 A1S

LCV-305 FA-306 1 DPW L 4 0.5 70 26,720 30,728 977 0.66 I/P 51.32 4 ANSI S A216WCB C 499 3 150 RF E SUS316L A2P

LCV-307 GA-317 1 WW L 4 0.5 40 3,300 4,950 978 1 I/P 8.4 1 1/2 ANSI S A216WCB O B 3DELIVERY 30 1 1/2 150 RF E SUS316L A2P

LCV-401 LCV-401 GA-401 1 WW L 1.8 0.2 40 1,203 1,384 1000 1.0 I/P 1 JIS E 6 C B.R 1 M.STO FA-803 5.2 1/2 10K RF 2 A2S

LCV-402 LCV-402 GA-402 1 WW L 1.8 0.2 40 962 1,107 990 0.66 I/P 1 JIS E 6 C B 1 M.STO FA-803 5.2 1/2 10K RF 2 A2S

LCV-502 DA-501 1 PS L 6 0.5 101 38,824 44,647 1100 I/P 3 V C 3OUTLET E A1K-P

LCV-701 FA-703 1 HW L 4 0.5 90 5,273 6,064 980 I/P 10.37 1 1/2 ANSI S SCS13A C B 3OUTLET 30 1 1/2 150 RF E SUS316L A5S

LCV-801 LCV-802 GA-801 1 WW L 1.8 0.2 AMB 301.34 347 861.4 1.0 I/P 1 JIS E 6 C B 1 M.SOUTLET 1.5 1/4 10K RF 2 A2S

LCV-802 GA-802 1 WW L 5 0.4 40 502.9 578 1000 1 I/P 1.067 1 JIS S A216WCB C B 1 OUTLET 4 10K RF E SUS316L A1S

LCV-803 GA-803 1 WW L 5 0.4 40 503 578 1000 1 I/P 0.955 1 ANSI S A216WCB C B 1 1/2OUTLET 2.5 150 RF E SUS316L A5S

LCV-901 FB-901 1 IW L 6 0.5 32 20,000 30,000 1000 1 50.75 3 ANSI S A216WCB C B 4MAKE UP IW 99 3 150 RF E SUS316L A1S

PCV-101 GA-100A 1 PA G 7 AMB 1/4 ANSI C 1 AIR SUPPLY 1/4 150 RF A5X

PCV-102 GA-100C 1 PA G 7 AMB 1/4 ANSI C 1

(kg/cm2G) (OC)

(kg/cm2G)

Page 4 of 26

TPC VINA PLASTIC AND CHEMICAL CORP.,LTDCONTROL VALVE SCHEDULE

PVC LINE 2 PROJECT

TAG NO.

Data from file : PV4 Instrument R29 Operating Condition SpecificationPVC-4 LIQ Press. Nor.Rate Max.Rate Vapor Input Cv Size

Rating

Port Mat'l Action Acces- LineTag no. Service No. Fluid STM Up P Temp. L:kg/h L:kg/h Density M.W. Signal Cal. (inch) Type (Note 2) sories Size M'F'R

Or Stream S:kg/h S:kg/h (kg/m3) Visc. Select Body (Note 1) Body (Note 3) (Note 4) Spec.

GAS G:Nm3/h G:Nm3/h (C.P.) Port Trim

(kg/cm2G) (OC)

(kg/cm2G)AIR SUPPLY 1/4 150 RF A5X

PCV-103 GA-100B 1 PA G 7 AMB 1/4 ANSI C 1/2AIR SUPPLY 1/4 150 RF A1X

PCV-211 PCV-211 GA-201 1 PW L 6 1 AMB 3,745 4,306 1000 1.0 I/P 4 JIS E 12 C A 3 M.SBY-PASS 192 4 10K RF 2 A1K

PCV-213 PCV-213 GA-204A/B 1 DW L 18 16 AMB 4,768 5,483 1000 1.0 I/P 1 JIS E 12 C B 1 M.SBY-PASS 3 3/8 20K RF 2,5 B1K

PCV-302 GA-301 1 PS L 3 0.5 58 39,360 45,264 1100 I/P 72.62 4 ANSI EC SCS13A C B 6OUTLET 100 150 RF E SCS14 A1K

PCV-305 OUTLET 1 RVCM GAS 3 0.2 75 24,104 27,719 9.2 0.012 I/P 441.9 8 ANSI 150 EC A216WCB C B 8FA-304 kg/hr kg/hr 510 WAFER E SCS14 A9K

PCV-311 FA-311 1 IA G 7 AMB 1/2 ANSI C 1/21/2 150 RF A5X

PCV-315 FA-324 1 LN G 7 AMB 1/2 ANSI C 1 N2 SEAL 1/2 150 RF A5X

PCV-401 PCV-401 GB-401 1 RVCM G 290 mmHg 0.1 40 1,748 2,010 0.87 I/P 2 JIS E 6 C B 2 M.SBY-PASS 2 10K RF 2 A2S

PCV-402 PCV-402 GB-402 1 RVCM G 6.5 4.5 40 3,805 7,293 2.28 I/P 2 JIS E 6 C B 2 M.SBY-PASS 2 10K RF 2 A2S

PCV-403-1 PCV-403-1 EA-404 1 RW L 3.2 0.2 5 4,348 5,218 1025 1.0 I/P 1 1/2 JIS E 6 C B 1 1/2 M.SINLET 30 1 1/2 10K RF 2 A5S-C

PCV-403-2 PCV-403-2 EA-404 1 WG G 5.5 0.2 25 21 34 12.23 0.014 I/P 1 JIS E 6 C B 1 M.SOUTLET 0.4 1/8 10K RF 2 A2S

PCV-404 EA-403 1 CW L 4 0.5 30 212,000 227,000 1000 1.0 I/P 374.8 8 JIS S A216WCB C B 8INLET 700 8 10K RF E SUS316L A1S

PCV-502 PCV-506 EA-502 1 PS SLURRY 3 0.1 75 39,506 45,432 1100 1.95 I/P 2 1/2 JIS V-BALL 12 C V-BALL 2 1/2 K.MOUT LET 2 1/2 10K RF 12 A1K-P

PCV-801 PCV-802 GB-801 1 RVCM G -130 0.15 40 38.4 44 2.94 I/P 1 JIS E 6 C B 3 M.SBY-PASS mmHg 0.8 3/16 10K RF 2 A2S

PCV-802 FA-803 1 RVCM G 5.5 0.5 60 44.17 51 2.94 I/P 2.08 1 ANSI S A216WCB C B 2INLET 6.3 150 RF E SUS316L A9A

PCV-804-1 GB-801 1 RVCM GAS 0 0.1 35 37 60 1.16 I/P 8.51 1 1/2 JIS S A216WCB C B 3INLET 30 1 1/2 10K RF E SUS316L A2S

Page 5 of 26

TPC VINA PLASTIC AND CHEMICAL CORP.,LTDCONTROL VALVE SCHEDULE

PVC LINE 2 PROJECT

TAG NO.

Data from file : PV4 Instrument R29 Operating Condition SpecificationPVC-4 LIQ Press. Nor.Rate Max.Rate Vapor Input Cv Size

Rating

Port Mat'l Action Acces- LineTag no. Service No. Fluid STM Up P Temp. L:kg/h L:kg/h Density M.W. Signal Cal. (inch) Type (Note 2) sories Size M'F'R

Or Stream S:kg/h S:kg/h (kg/m3) Visc. Select Body (Note 1) Body (Note 3) (Note 4) Spec.

GAS G:Nm3/h G:Nm3/h (C.P.) Port Trim

(kg/cm2G) (OC)

(kg/cm2G)

PCV-804-2 GB-801 1 RVCM GAS 0 0.1 35 20 30 1.16 I/P 4.17 1 ANSI S A216WCB C B 1 INLET 10 1 150 RF E SUS316L A9A

TCV-301A/B-1 EA-303A/B 2 CW L 4 0.5 30 600,000 1000 1.0 I/P 10 JIS E 6 O B 10JACKET HEATER 8 10K RF 2 A1S

TCV-301A/B-2 EA-301A/B 2 CW L 4 0.5 30 462,000 1000 1.0 I/P 6 JIS E 6 O B 6INLET 6 10K RF 2 A5S

TCV-303A/B HCV-303A/B EA-303A/B 2 LS S 7 0.5 170 4,970 I/P 6 JIS E SCPH2 C B 6 M.SINLET 390 6 10K RF 2,5 Rx3 A2S-H

TCV-304 TCV-304 EA-302 1 CW L 4 0.5 30 61,000 1000 1.0 I/P 6 JIS E SCPH2 C B 5 M.SINLET 275 5 10K RF 2 A1S

TCV-401-1 EA-402 1 CWR L 4 0.5 30 50,000 1000 1.0 I/P 82.5 3 JIS S A216WCB O B 3OUTLET 125 3 10K RF E SUS316L A1S

TCV-401-2 FA-402 1 LS S 7 3 170 100 I/P 1.25 1 JIS S SCPH2 C B 1 INLET 4 10K RF E SUS316L A1S-H

Page 6 of 26

TPC VINA PLASTIC AND CHEMICAL CORP.,LTDCONTROL VALVE SCHEDULE

PVC LINE 2 PROJECT

TAG NO.

Data from file : PV4 Instrument R29 Operating Condition SpecificationPVC-4 LIQ Press. Nor.Rate Max.Rate Vapor Input Cv Size

Rating

Port Mat'l Action Acces- LineTag no. Service No. Fluid STM Up P Temp. L:kg/h L:kg/h Density M.W. Signal Cal. (inch) Type (Note 2) sories Size M'F'R

Or Stream S:kg/h S:kg/h (kg/m3) Visc. Select Body (Note 1) Body (Note 3) (Note 4) Spec.

GAS G:Nm3/h G:Nm3/h (C.P.) Port Trim

(kg/cm2G) (OC)

(kg/cm2G)TCV-502 EA-503 1 CWR L 4 0.5 30 150,000 175,000 1000 1.0 I/P 109.2 6 JIS S A216WCB C B 6 M.S

OUTLET 275 5 10K RF E SUS316L A1K

TCV-513 TCV-502 EA-505 1 LS S 7 0.5 170 830 4 I/P 2 1/2 JIS E SCPH2 C B.R 2 1/2 M.SINLET 81 2 1/2 10K RF 2,5 A1S-H

TCV-515 TCV-503 FA-505 1 LS S 7 5 170 40 4 I/P 1 JIS E 1 C 3/4 M.SINLET 1.5 1/4 10K RF 2,5 A3K-H

TCV-501 EA-501A/B 1 LS S 7 0.4 170 778 895 I/P 26.47 2 JIS S SCS13A C B 2INLET 50 2 10K RF E SUS316L A1K-H

TCV-702 TCV-701 FA-701 1 LS S 7 5 170 2,700 4 I/P 4 JIS E SCPH2 C B 4 M.SINLET 0 40 2 10K RF 2 A1S-H

TCV-801-1 EA-802 1 CWR L 4 0.5 30 10,000 1000 1.0 I/P 16.51 1 1/2 JIS S A216WCB O B 1 1/2 M.SOUTLET 30 1 1/2 10K RF E SUS316L A1S

TCV-801-2 TCV-801-2 FA-802 1 LS S 7 0.5 170 100 4 I/P 3/4 JIS E SCPH2 C B 1 M.SINLET 5.2 1/2 10K RF 2.5 A6S-H

HCV-303A/B DC-301A/B 2 RVCM GAS 3 0.2 75 24,104 27,719 9.2 0.012 I/P 441.1 8 ANSI S A216WCB C B 8TO FA-303 kg/hr kg/hr 700 8 150 RF E SUS316L A2S

HCV-503 GB-501 C 40SUCTION A2X

PCV-511 GB-503 C #1000SUCTION A2X-H

XSV-101 XSV-101 FA-111 1 PW L E/P 1 JIS B 12 C W(O).R 1 K.MINLET 1 10K RF 1,13 W(C) A1K

XSV-102 XSV-102 FA-111 1 CAT+ L E/P 1 JIS B 12 C W(O).R 1 K.MDISCHARGE PW 1 10K RF 1,13 W(C) A1K

XSV-103A/B XSV-103A/B GA-111 2 CAT+ L E/P 1 JIS B 12 C W(O).R 1 K.MDELIVERY PW 1 20K RF 1,13 W(C) B1K

XSV-105 XSV-105 GA-104 1 VCM L E/P 6 JIS B 12 C W(O).R 6 K.MDELIVERY 6 20K RF 12,14 W(C)H B1J

XSV-106 FSV-305 DC-301A/B 1 VCM L 5.3 0.5 34 13800 158700 884 0.21 E/P 6 JIS B 12 C W(O).R 6 K.MFEED 6 20K RF 12,14 W(C)A B1L

XSV-111 FA-111 1 AG2 L E/P 1 ANSI B CF8M F,RO W(O),R 1 AG- INLET 1 150 RF 316 SS W(C) A7K

XSV-301A/B XSV-301A/B DC-301A/B 2 DW L E/P 6 JIS B 12 C W(O)R 6 K.MFEED 6 20K RF 12,14 W(C)A A1K

Rx2XSV-302A/B XSV-302A/B DC-301A/B 2 VG G E/P 6 JIS B 12 C W(O)R 6 K.M

Page 7 of 26

TPC VINA PLASTIC AND CHEMICAL CORP.,LTDCONTROL VALVE SCHEDULE

PVC LINE 2 PROJECT

TAG NO.

Data from file : PV4 Instrument R29 Operating Condition SpecificationPVC-4 LIQ Press. Nor.Rate Max.Rate Vapor Input Cv Size

Rating

Port Mat'l Action Acces- LineTag no. Service No. Fluid STM Up P Temp. L:kg/h L:kg/h Density M.W. Signal Cal. (inch) Type (Note 2) sories Size M'F'R

Or Stream S:kg/h S:kg/h (kg/m3) Visc. Select Body (Note 1) Body (Note 3) (Note 4) Spec.

GAS G:Nm3/h G:Nm3/h (C.P.) Port Trim

(kg/cm2G) (OC)

(kg/cm2G)OUTLET 6 20K RF 12,14 W(C)A A1K

XSV-303A/B XSV-303A/B DC-301A/B 2 VCM L E/P 6 JIS B 12 C W(O)R 6 K.MFEED 6 20K RF 12,14 W(C)A B1L

XSV-304A/B XSV-304A/B DC-301A/B 2 AG19 L E/P 1 JIS B 1 C W(O)R 1 K.MFEED 1 20K RF 1,14 W(C)A A1K

XSV-305A/B XSV-305A/B DC-301A/B 2 AG-2 L E/P 1 JIS B 1 C W(O)R 1 1/2 K.MFEED 1 20K RF 1,14 W(C)A A1K

XSV-306A/B XSV-306A/B DC-301A/B 2 AG-3 L E/P 1 JIS B 1 C W(O)R 1 1/2 K.MFEED 1 20K RF 1,14 W(C)A A1K

XSV-307A/B XSV-307A/B DC-301A/B 2 AG-1 L E/P 1 JIS B 1 C W(O)R 1 1/2 K.MFEED 1 20K RF 1,14 W(C)A A1K

XSV-308A/B XSV-308A/B DC-301A/B 2 CAT L E/P 1 JIS B 1 C W(O)R 1 K.MFEED 1 20K RF 1,14 W(C)A B1K

XSV-309A/B DC2301A/B 2 AD-5 LIQ E/P 1 ANSI B CF8M F,RO W(O),R 1 FEED 1 300 RF 316 SS W(C) A7K-H

XSV-310A/B XSV-310A/B DC-301A/B 2 AD-3 L E/P 1 JIS B 1 C W(O)R 1 K.MFEED 1 20K RF 1,14 W(C)A A1K

XSV-311A/B XSV-311A/B DC-301A/B 2 R-VCM G E/P 8 JIS B 12 C W(O)R 1 K.MOUTLET 8 20K RF 12,14 W(C)H A2S

XSV-312A/B DC-301A/B 2 PW L E/P 2 ANSI B CF8M C W(O),R 2HEADER WASH 2 300 RF 316 SS W(C) A7K

XSV-313A/B DC-301A/B 2 PW L E/P 2 ANSI B CF8M C W(O),R 2HEADER WASH 2 150 RF 316 SS W(C) A7K

XSV-314A/B XSV-314A/B DC-301A/B 2 VCM G E/P 4 JIS B 12 C W(O)R 4 K.MEQ LINE 4 20K RF 12,14 W(C) B1L

XSV-315A/B XSV-315A/B DC-301A/B 2 AIR G E/P 3 JIS B 12 C W(O)R 3 K.MVENTILATION 3 20K RF 12,14 W(C) B1L

XSV-316A/B XSV-316A/B DC-301A/B 2 VG G E/P 6 JIS B 12 C W(O)R 6 K.MOUTLET 6 20K RF 12,14 W(C) B1L

XSV-317A/B XSV-317A/B AG-19 NOZZLE 2 PW L E/P 1 JIS B 1 C W(O)R 1 K.MFLUSHING 1 20K RF 1,14 W(C) B1L

XSV-318A/B XSV-318A/B DC-301A/B 2 PS.PW L E/P 10 JIS B 12 C W(O)R 8 K.MDISCHARGE 8 20K RF 1,13 W(C)H B1K

XSV-319A/B XSV-319A/B PRA-302A/B 2 VCM G E/P 1/2 JIS B 1 C W(O)R 1/2 K.MDETECT LINE 1/2 20K RF 1,14 W(C) B1L

XSV-320A/B DC-301A/B 2 WW LIQ E/P 8 ANSI B CF8M F,RO W(O),R 8DISCHARGE 8 300 RF 316 SS W(C) B1K

XSV-321A/B XSV-321A/B DC-301A/B 2 DW L E/P 1 JIS B 1 C W(O)R 1 K.MFLUSHING 1 20K RF 1,14 W(C) B1K

XSV-322A/B XSV-322A/B EA-303A/B 2 LS S E/P 6 JIS B SCPH C W(O)R 6 K.MINLET 6 10K RF 12,13 W(C) A2S-H

XSV-323A/B XSV-323A/B EA-301A/B 2 DW L E/P 1 JIS B 1 C W(O)R 1 K.MFEED 1 20K RF 1,14 W(C) B1K

XSV-324A/B XSV-324A/B EA-301A/B 2 R-VCM G E/P 1 JIS B 1 C W(O)R 1 K.MINERT 1 20K RF V W(C) A2S

Page 8 of 26

TPC VINA PLASTIC AND CHEMICAL CORP.,LTDCONTROL VALVE SCHEDULE

PVC LINE 2 PROJECT

TAG NO.

Data from file : PV4 Instrument R29 Operating Condition SpecificationPVC-4 LIQ Press. Nor.Rate Max.Rate Vapor Input Cv Size

Rating

Port Mat'l Action Acces- LineTag no. Service No. Fluid STM Up P Temp. L:kg/h L:kg/h Density M.W. Signal Cal. (inch) Type (Note 2) sories Size M'F'R

Or Stream S:kg/h S:kg/h (kg/m3) Visc. Select Body (Note 1) Body (Note 3) (Note 4) Spec.

GAS G:Nm3/h G:Nm3/h (C.P.) Port Trim

(kg/cm2G) (OC)

(kg/cm2G)

XSV-325A/B DC-301 2 DW L E/P 1 ANSI B CF8M F,RO W(O),R 1 DW MAIN 1 150 RF 316 SS W(C) B1K

XSV-326 FA-304 1 LS S E/P 3 ANSI B CF8M C W(O),R 33 150 RF 316 SS W(C) A6S-H

XSV-327 FA-304 1 PW L E/P 1 ANSI B CF8M C W(O),R 1 1 150 RF 316 SS W(C) A7K

XSV-328 FA-324 1 AFA L E/P 1 ANSI B CF8M C W(O),R 1 OUTLET 1 150 RF 316 SS W(C) A7K

XSV-329A/B CAT10 2 CAT10 LIQ E/P 3/4 ANSI B CF8M F,RO W(O),R 3/43/4 150 RF 316 SS W(C) A1A

XSV-330A/B CAT8 2 DW LIQ E/P 1/2 ANSI B CF8M F,RO W(O),R 1/21/2 300 RF 316 SS W(C) B6A

XSV-331A/B XSV-333A/B DC-301A/B 2 PS L E/P 8 JIS B 12 C W(O)R 8 K.MDISCHARGE AFA 8 20K RF 12,14 W(C) B1K

XSV-332A/B XSV-331A/B DC-301A/B 2 PS L E/P 8 JIS B 12 C W(O)R 8 K.MDISCHARGE 8 20K RF 12,14 W(C) B1K

XSV-333A/B XSV-332A/B DC-301A/B 2 PW L E/P 8 JIS B 12 C W(O)R 8 K.MRINSE WATER 8 20K RF 12,14 W(C) B1K

XSV-334A/B DC-301A/B 2 PW LIQ E/P 2 ANSI B CF8M F,RO W(O),R 22 150 RF 316 SS W(C) A7K

XSV-335 XSV-336 PW TO 1 PW L E/P 3 JIS B 12 C W(O)R 3 K.MDC-301A/B 3 20K RF 12,14 W(C) A1K

XSV-336 XSV-335 GA-308 1 PW L E/P 4 JIS B 12 C W(O)R 4 K.MDELIVERY 4 20K RF 12,14 W(C) A1K

XSV-337A/B DC-301A/B 2 CW L E/P 10 ANSI B CF8M C W(O),R 10JACKET 10 150 RF 316 SS W(C) A1S

XSV-339A/B DC-301A/B 2 VC GAS E/P 4 ANSI B CF8M C W(O),R 44 150 RF 316 SS W(C) A7K

XSV-343 FA-304 1 CAT-10 LIQ E/P 3/4 ANSI B CF8M C W(O),R 3/43/4 150 RF 316 SS W(C) A9A

XSV-341A/B-1 FA-302A/B 2 INH-3 LIQ E/P 1 ANSI B CF8M F,RO W(O),R 1 DELIVERY 1 150 RF 316 SS W(C) B2J-H

XSV-342A/B-1 DC-301A/B 2 INH-3 LIQ E/P 1 ANSI B CF8M F,RO W(O),R 1 TOP INLET 1 150 RF 316 SS W(C) B2J-H

XSV-343A/B-1 FA-302A/B 2 INH-3 LIQ E/P 3/4 ANSI B CF8M F,RO W(O),R 3/4PURGE 3/4 150 RF 316 SS W(C) B2J-H

XSV-341A/B-2 FA-302A/B 2 INH-3 LIQ E/P 1 ANSI B CF8M F,RO W(O),R 1 DELIVERY 1 300 RF 316 SS W(C) C1K

XSV-342A/B-2 DC-301A/B 2 INH-3 LIQ E/P 1 ANSI B CF8M F,RO W(O),R 1 TOP INLET 1 300 RF 316 SS W(C) C1K

XSV-343A/B-2 FA-302A/B 2 INH-3 LIQ E/P 3/4 ANSI B CF8M F,RO W(O),R 3/4PURGE 3/4 300 RF 316 SS W(C) C1K

XSV-349 EE-302 1 RCS-1 LIQ E/P 1 ANSI B CF8M C W(O),R 1 INLET 1 150 RF 316 SS W(C) A1K

Page 9 of 26

TPC VINA PLASTIC AND CHEMICAL CORP.,LTDCONTROL VALVE SCHEDULE

PVC LINE 2 PROJECT

TAG NO.

Data from file : PV4 Instrument R29 Operating Condition SpecificationPVC-4 LIQ Press. Nor.Rate Max.Rate Vapor Input Cv Size

Rating

Port Mat'l Action Acces- LineTag no. Service No. Fluid STM Up P Temp. L:kg/h L:kg/h Density M.W. Signal Cal. (inch) Type (Note 2) sories Size M'F'R

Or Stream S:kg/h S:kg/h (kg/m3) Visc. Select Body (Note 1) Body (Note 3) (Note 4) Spec.

GAS G:Nm3/h G:Nm3/h (C.P.) Port Trim

(kg/cm2G) (OC)

(kg/cm2G)XSV-350 INLET 1 MS STM E/P 1 1/2 ANSI B CF8M C W(O),R 1 1/2

FE-302 1 1/2 300 RF 316 SS W(C) B1S-H

XSV-348A/B EA-301A/B TOP 2 PW L E/P 2 ANSI B CF8M C W(O),R 2RINSE VALVE 2 300 RF 316 SS W(C) B1K

XSV-353A/B DC-301A/B SIDE 2 PW L E/P 2 ANSI B CF8M C W(O),R 2RINSE VALVE 2 300 RF 316 SS W(C) B1J

XSV-354A/B DC-301A/B SIDE 2 PW L E/P 2 ANSI B CF8M C W(O),R 2RINSE VALVE 2 300 RF 316 SS W(C) B1J

XSV-359A/B RCS-1 2 RCS-1 LIQ E/P 1 1/2 ANSI B CF8M C W(O),R 1 1/2TO DC-301A/B 1 1/2 300 RF 316 SS W(C) B1K-H

XSV-361 XSV-361 GB-301 1 VG G E/P 6 JIS B SCPH2 C W(O)R 6 K.MSUCTION 6 10K RF 12,13 W(C) A1S

XSV-362 XSV-362 EJECTOR 1 AIR G E/P 2 1/2 JIS B SCPH2 C W(O)R 2 1/2 K.M1SUCTION 2 1/2 10K RF 12,13 W(C) A1S

XSV-363 XSV-363 GB-301 1 IW G E/P 1 1/2 JIS B SCPH2 C W(O)R 1 1/2 K.MSEAL 1 1/2 10K RF 12,13 W(C) A1S

XSV-368A/B INLET 2 AFA L E/P 1 1/2 ANSI B CF8M C W(O),R 1 1/2DC-301A/B 1 1/2 300 RF 316 SS W(C) B1K-H

XSV-369A/B INLET 2 AFA L E/P 1 1/2 ANSI B CF8M C W(O),R 1 1/2DC-301A/B 1 1/2 300 RF 316 SS W(C) B1K-H

XSV-370A/B INLET 2 RCS-1 L E/P 1 1/2 ANSI B CF8M C W(O),R 1 1/2DC-301A/B 1 1/2 300 RF 316 SS W(C) B1K-H

XSV-371 XSV-371 FD-301 1 PW L E/P 3 JIS B 12 C W(O)R 3 K.MINLET 3 10K RF 12,13 W(C) A1K

XSV-372 XSV-372 GA-301 1 PW L E/P 1/2 JIS B SCH14 C W(O)R 1/2 K.MSEAL 1/2 10K RF SCS14,13 W(C) A1K

XSV-373 GA-301 1 PS SLUR E/P 6 ANSI B CF8M C W(O),R 6DISCHARGE RY 6 150 RF 316 SS W(C) A1K

XSV-374A/B DC-301A/B 2 DPW LIQ E/P 2 ANSI B CF8M C W(O),R 22 150 RF 316 SS W(C) A7K

XSV-375 FA-310 1 DPW L E/P 4 ANSI B CF8M C W(O),R 4INLET 4 150 RF 316 SS W(C) A7K

XSV-376 GA-301 1 PS SLUR E/P 6 ANSI B CF8M C W(O),R 6RY 6 150 RF 316 SS W(C) A7K

XSV-377 FA-310 1 PS SLURRY E/P 6 ANSI B CF8M C W(O),R 6INLET 6 150 RF 316 SS W(C) A9K

XSV-378 FA-310 1 EQ G E/P 4 ANSI B CF8M C W(O),R 44 150 RF 316 SS W(C) A9K

XSV-379 FA-304 1 LEQ GAS E/P 3 ANSI B CF8M F,RO W(O),R 33 150 RF 316 SS W(C) A9K

Rx2XSV-380 FA-304 1 LEQ GAS E/P 4 ANSI B CF8M F,RO W(O),R 4

4 150 RF 316 SS W(C) A9K

XSV-381 FA-304 1 PS SLUR E/P 6 ANSI B CF8M C W(O),R 6RY 6 150 RF 316 SS W(C) A7K

XSV-382 FA-304 1 RVCM GAS E/P 8 ANSI B CF8M C W(O),R 8

Page 10 of 26

TPC VINA PLASTIC AND CHEMICAL CORP.,LTDCONTROL VALVE SCHEDULE

PVC LINE 2 PROJECT

TAG NO.

Data from file : PV4 Instrument R29 Operating Condition SpecificationPVC-4 LIQ Press. Nor.Rate Max.Rate Vapor Input Cv Size

Rating

Port Mat'l Action Acces- LineTag no. Service No. Fluid STM Up P Temp. L:kg/h L:kg/h Density M.W. Signal Cal. (inch) Type (Note 2) sories Size M'F'R

Or Stream S:kg/h S:kg/h (kg/m3) Visc. Select Body (Note 1) Body (Note 3) (Note 4) Spec.

GAS G:Nm3/h G:Nm3/h (C.P.) Port Trim

(kg/cm2G) (OC)

(kg/cm2G)8 150 RF 316 SS W(C) A9K

XSV-383 RINSE 1 DPW LIQ E/P 2 ANSI B CF8M C W(O),R 2WATER 2 150 RF 316 SS W(C) A7K

XSV-384 FA-304 1 DW L E/P 1 ANSI B CF8M F,RO W(O),R 1 1 150 RF 316 SS W(C) B2J

XSV-385 FA-304 1 PS SLURRY E/P 8 ANSI B CF8M C W(O),R 8OUTLET 8 150 RF 316 SS W(C) A9K

XSV-386 FA-304 1 PW LIQ E/P 2 ANSI B 13 C W(O),R 22 150 RF CF8M W(C) A7K

316 SSXSV-387 FA-304 1 AD5 LIQ E/P 1 ANSI B CF8M C W(O),R 1

1 150 RF 316 SS W(C) A7K-H

XSV-388 FA-311 1 IA G E/P 1 ANSI B CF8M C W(O),R 1 1 150 RF 316 SS W(C) A5X

XSV-389 FA-311 1 IA G E/P 1 ANSI B CF8M C W(O),R 1 1 150 RF 316 SS W(C) A5X

XSV-390 FA-311 1 IA G E/P 1/2 ANSI B CF8M C W(O),R 1/2

1/2 150 RF 316 SS W(C) A5X

XSV-391A/B HCV-301A/B DC-301A/B 2 DW.VCM L P 8 JIS B 12 C W(O)H 8 K.MHEADER 8 20K RF 12,14 W(C) B1L

XSV-392A/B HCV-302A/B DC-301A/B 2 PW,VCM L P 8 JIS B 12 C W(O)H 8 K.MHEADER 8 20K RF 12,13 W(C) B1L

XSV-393 FA-310 1 PS SLURRY E/P 8 ANSI B CF8M F,RO W(O),R 8OUTLET 8 150 RF 316 SS W(C) A9K

XSV-394 GA-302 1 PS SLURRY E/P 8 ANSI B CF8M F,RO W(O),R 8INLET 8 150 RF 316 SS W(C) A9K

XSV-395 FD-302 1 PW L E/P 1 1/2 ANSI B CF8M C W(O),R 1 1/2INLET 1 1/2 150 RF 316 SS W(C) A7K

XSV-396 FD-302 1 VG G E/P 1 ANSI B CF8M C W(O),R 1 OUTLET 1 150 RF 316 SS W(C) A9A

XSV-397 FD-302 1 PS SLURRY E/P 6 ANSI B CF8M C W(O),R 6OUTLET 6 150 RF 316 SS W(C) A9K

XSV-398 GA-302 1 PW L E/P 1 ANSI B CF8M C W(O),R 1 SEAL WATER 1 150 RF 316 SS W(C) A7K

XSV-399 IA FROM 1 IA G E/P 1 ANSI B CF8M C W(O),R 1 FA-311 1 150 RF 316 SS W(C) A5K

XSV-401 XSV-401 EA-302 TO 1 RVCM G E/P 6 JIS B SCPH2 C W(O)R 6 K.MFA-403 6 10K RF 12,13 W(C) A2S

XSV-402 XSV-402 GB-402 1 RVCM G E/P 6 JIS B SCPH2 C W(O)R 6 K.MSUCTION 6 10K RF 12,13 W(C) A2S

XSV-403 XSV-403 GB-401 1 RVCM G E/P 6 JIS B SCPH2 C W(O)R 6 K.MSUCTION 6 10K RF 12,13 W(C) A2S

XSV-404 XSV-404 GB-402 1 RVCM G E/P 6 JIS B SCPH2 C W(O)R 6 K.MSUCTION 6 10K RF 12,13 W(C) A2S

XSV-415 GA-403A/B 1 RVCM L E/P 1 ANSI B CF8M F,RO W(O),R 1 DISCHARGE 1 300 RF 316 SS W(C) B1A

Page 11 of 26

TPC VINA PLASTIC AND CHEMICAL CORP.,LTDCONTROL VALVE SCHEDULE

PVC LINE 2 PROJECT

TAG NO.

Data from file : PV4 Instrument R29 Operating Condition SpecificationPVC-4 LIQ Press. Nor.Rate Max.Rate Vapor Input Cv Size

Rating

Port Mat'l Action Acces- LineTag no. Service No. Fluid STM Up P Temp. L:kg/h L:kg/h Density M.W. Signal Cal. (inch) Type (Note 2) sories Size M'F'R

Or Stream S:kg/h S:kg/h (kg/m3) Visc. Select Body (Note 1) Body (Note 3) (Note 4) Spec.

GAS G:Nm3/h G:Nm3/h (C.P.) Port Trim

(kg/cm2G) (OC)

(kg/cm2G)

XSV-416 EA-404 1 RVCM L E/P 1 ANSI B CF8M C W(O),R 1 1 150 RF 316 SS W(C) A9A

XSV-421 XSV-407 FA-407 1 INH-1 L E/P 1 JIS B SCPH2 C W(O)R 1 K.MINLET 1 10K RF 12,13 W(C) A2S

XSV-422 XSV-405 FA-407 1 INH-1 L E/P 1 JIS B SCPH2 C W(O)R 1 K.MINLET 1 10K RF 12,13 W(C) A7K

XSV-423 GA-403A/B 1 INH-1 L E/P 1 ANSI B CF8M C W(O),R 1 DISCHARGE 1 150 RF 316 SS W(C) A9A

XSV-424 FA-802 1 VG GAS E/P 1/2 ANSI B CF8M F,RO W(O),R 1/2INLET 1/2 150 RF 316 SS W(C) A7K

XSV-425 XSV-411 FA-403 1 RVCM GAS E/P 2 JIS B 6 C W(O).R 2 KITZBOTTOM 2 10K RF 1,15 W(C) A5S

XSV-426A/B/C XSV-408 DA-401A/B/C 3 RVCM GAS E/P 1 1/2 JIS B 6 C W(O).R 1 1/2 KITZXSV-409 1 1/2 10K RF 1,15 W(C) A2SXSV-410

XSV-427 XSV-413 DA-401A/B/C 1 PW LIQ E/P 1 ANSI B 6 C W(O).R 1 1/2 KITZBOTTOM 1 150 RF 1,15 W(C) A1S-H

XSV-430 VCM FROM 1 VCM L E/P 6 ANSI B CF8M C W(O),R 6GA-404A/B 6 300 RF 316 SS W(C) B1J-C

XSV-431 FA-404 1 VCS L E/P 2 ANSI B CF8M C W(O),R 2INLET 2 300 RF 316 SS W(C) B2J

XSV-433 GA-404A/B 1 VCS L E/P 2 ANSI B CF8M C W(O),R 2CIRCULATION 2 300 RF 316 SS W(C) B6A

XSV-501 FA-501B/C 1 PS SLURRY E/P 4 ANSI B CF8M F,RO W(O),R 44 150 RF 316 SS W(C) A3J

Rx2XSV-502 FA-501B/C 1 PS SLURRY E/P 4 ANSI B CF8M F,RO W(O),R 4

4 150 RF 316 SS W(C) A3JRx2

XSV-507A/B XSV-501A/B GF-501A/B 2 PS SLURRY E/P 2 1/2 JIS B 12 C W(O)R 3 K.MSUCTION 2 1/2 10K RF 1,13 W(C) A1K-P

XSV-509 FA-501B/C 1 PW LIQ E/P 1 ANSI B CF8M F,RO W(O),R 1 RETURN LINE 1 150 RF 316 SS W(C) A1K

XSV-511 EQ LINE 1 LEQ GAS E/P 3 ANSI B CF8M F,RO W(O),R 3TO FA-304 3 150 RF 316 SS W(C) A9K

XSV-513-1~4 LS INLET 4 LS STM E/P 1 ANSI B CF8M F,RO W(O),R 1 DA-501 1 150 RF 316 SS W(C) A3K-H

XSV-514 XSV-506 FD-505 TO 1 PW L E/P 1 JIS B 12 C W(O)R 1 K.MDA-501 1 10K RF 1,13 W(C) A7K

XSV-515B/C FA-501B/C 2 PW LIQ E/P 1 ANSI B CF8M F,RO W(O),R 1 AERATION RING 1 150 RF 316 SS W(C) A1K

XSV-516B/C FA-501B/C 2 AIR GAS E/P 4 ANSI B CF8M F,RO W(O),R 4AERATION RING 4 150 RF 316 SS W(C) A1K-P

XSV-517B/C FA-501B/C 2 LS STM E/P 2 ANSI B CF8M F,RO W(O),R 2AERATION RING 2 150 RF 316 SS W(C) A1K-H

XSV-518A FA-501A/B/C 1 PW LIQ E/P 2 ANSI B CF8M C W(O),R 22 150 RF 316 SS W(C) A7K

Page 12 of 26

TPC VINA PLASTIC AND CHEMICAL CORP.,LTDCONTROL VALVE SCHEDULE

PVC LINE 2 PROJECT

TAG NO.

Data from file : PV4 Instrument R29 Operating Condition SpecificationPVC-4 LIQ Press. Nor.Rate Max.Rate Vapor Input Cv Size

Rating

Port Mat'l Action Acces- LineTag no. Service No. Fluid STM Up P Temp. L:kg/h L:kg/h Density M.W. Signal Cal. (inch) Type (Note 2) sories Size M'F'R

Or Stream S:kg/h S:kg/h (kg/m3) Visc. Select Body (Note 1) Body (Note 3) (Note 4) Spec.

GAS G:Nm3/h G:Nm3/h (C.P.) Port Trim

(kg/cm2G) (OC)

(kg/cm2G)XSV-518B/C FA-501A/B/C 1 PW LIQ E/P 2 ANSI B CF8M C W(O),R 2

2 150 RF 316 SS W(C) A1K

XSV-520A/B XSV-507A/B GF-501A/B 2 PW L E/P 1 JIS B 12 C W(O)R 1 K.MSUCTION LINE 1 10K RF 1,13 W(C) A1K

XSV-521A/B GF-501A/B 2 PW LIQ E/P 1/2 ANSI B CF8M F,RO W(O),R 1/21/2 150 RF 316 SS W(C) A1K

XSV-524B/C XSV-502A/B FA-501B 1 PS SLURRY E/P 4 JIS B 12 C W(O)R 4 K.MBOTTOM 4 10K RF 1,13 W(C) A1K

XSV-525B/C XSV-503A/B FA-501A 1 PW L E/P 1 1/2 JIS B 12 C W(O)R 1 1/2 K.MBOTTOM LINE 1 1/2 10K RF 1,13 W(C) A1K

XSV-527 EA-501 1 PW LIQ E/P 2 ANSI B CF8M C W(O),R 22 150 RF 316 SS W(C) A7K

XSV-528 EA-501 1 PW LIQ E/P 2 ANSI B CF8M C W(O),R 22 150 RF 316 SS W(C) A7K

XSV-531 PW 1 PW LIQ E/P 1 ANSI B CF8M C W(O),R 1 FLUSHING 1 150 RF 316 SS W(C) A1K

XSV-808 XSV-801 GB-801 1 R-VCM GAS E/P 3 JIS B SCPH2 C W(O) R 3 K.MSUCTION 3 10K RF 1,13 W(C) A2S

XSV-801 FA-804 1 RVCM GAS E/P 1 ANSI B CF8M F,RO W(O),R 1 1 150 RF 316 SS W(C) A9A

XSV-802 BOTTOM 1 WW LIQ E/P 1 1/2 ANSI B CF8M F,RO W(O),R 1 1/2FA-804 1 1/2 150 RF 316 SS W(C) A5S

XSV-803 FA-802 1 RVCM GAS E/P 2 ANSI B CF8M F,RO W(O),R 2RVCM TO FA-403 2 150 RF 316 SS W(C) A9A

XSV-806 INLET 1 RVCM GAS E/P 3 ANSI B CF8M F,RO W(O),R 3GB-801 3 150 RF 316 SS W(C) A2S

EMV-102 XSV-104 FA-1105 1 VCM L E/P 8 JIS B 12 C W(O).R 8 K.MDIS CHARGE 8 10K RF 12,13 W(C)H A1L-C

PCV-910 LS 1 LS S 7 0.5 170 2.1 5.00 I/P 82.38 4 JIS S A216WCB C B 8MAIN Ton/hr Ton/hr 175 4 20K RF E SUS316L B1A-H

PCV-902 PCV-902 FF-501 1 LS S 7 5 176 100 4 1 JIS SCPH2 C 2TRACE 1 10K RF 2 A1S

HCV-504

Page 13 of 26

TPC VINA PLASTIC AND CHEMICAL CORP.,LTDCONTROL VALVE SCHEDULE

PVC LINE 2 PROJECT

TAG NO.

Data from file : PV4 Instrument R29 Operating Condition SpecificationPVC-4 LIQ Press. Nor.Rate Max.Rate Vapor Input Cv Size

Rating

Port Mat'l Action Acces- LineTag no. Service No. Fluid STM Up P Temp. L:kg/h L:kg/h Density M.W. Signal Cal. (inch) Type (Note 2) sories Size M'F'R

Or Stream S:kg/h S:kg/h (kg/m3) Visc. Select Body (Note 1) Body (Note 3) (Note 4) Spec.

GAS G:Nm3/h G:Nm3/h (C.P.) Port Trim

(kg/cm2G) (OC)

(kg/cm2G)

Page 14 of 26

References P&IDand/or balance

Remarks No.

D005,6CW Item 3,4

D010420

D012A###

D012A508

D013701

D012A526

D022Summary

D004###

D008405

D006A###

D016FA2308

D007###

D007###

D009407

D009410

D012A516

D018710

D019804

D019###

D019###

D022

PRESS. REGULATOR VALVE D001

PRESS. REGULATOR VALVE D002

Page 15 of 26

References P&IDand/or balance

Remarks No.

PRESS. REGULATOR VALVE D004A

D004###

D004###

D006A###

D006B###

PRESS. REGULATOR VALVE D006A

PRESS. REGULATOR VALVE D004A

D009412

D009414

SPLIT RANGE D010Data sheet

EA404SPLIT RANGE D010

416

D010EA2403

D012A526

D019803

D019###

SPLIT RANGE D019Copy from L-5

Page 16 of 26

References P&IDand/or balance

Remarks No.

SPLIT RANGE D019Copy from L-5

SPLIT RANGE D005,6EA230A/B

SPLIT RANGE D005,6EA2301A/B

D005,6EA2303A/B

D008EA2302

SPLIT RANGE D009EA2402

SPLIT RANGE D009FA2402

Page 17 of 26

References P&IDand/or balance

Remarks No.

D012AEA2503

D013EA2505

D014FD2502

D012EA2501A/B

D018FA2701

SPLIT RANGE D019EA2802

SPLIT RANGE D019FA2701

D005,6

D013

D013

D002

D002

D002

D003

D003106+422

D002

D005,6

D005,6

Page 18 of 26

References P&IDand/or balance

Remarks No.

D005,6

D005,6

D005,6

D005,6

D005,6

D005,6

D005,6

D005,6

D005,6

D005,6

D005,6

D005,6

D005,6

D005,6

5D2

D005,6

D005,6

D005,6

D005,6

D005,6

D005,6

D005,6

Page 19 of 26

References P&IDand/or balance

Remarks No.

D005,6

D006B

D006B

D004A

D005,6

D005,6

D005,6

D005,6

D005,6

D005,6

D007

D007

D005,6

D005,6

D006B

D005,6

D005,6

D005,6

D005,6

D005,6

D005,6

D004A

Page 20 of 26

References P&IDand/or balance

Remarks No.

D004A

D005,6

D005,6

D005,6

D004A

D015

D015

D015

D005,6

D005,6

D005,6

D006A

D006A

D006A

D005,6

D006B

D005,6

D006B

D006B

D006B

D006B

D006B

D006B

Page 21 of 26

References P&IDand/or balance

Remarks No.

D006B

D006B

D006B

D006B

D006B

D006A

D006A

D006A

D005,6

D005,6

D006B

D006B

D006B

D006B

D006B

D006B

D006A

D009

D009

D009

D009

D010

Page 22 of 26

References P&IDand/or balance

Remarks No.

D010

D009

D009

D010

D019

D010

D010

D010

D003

D010B

D010B

D012

D012

D012A

D012A

D011A

D012A

D012A

D012

D012

D012

D011A

Page 23 of 26

References P&IDand/or balance

Remarks No.

D012

D012A

D012A

D012

D012

D012A

D012A

D012

D019

D019

D019

D019

D019

D003

D001-1

SELF ACTUATED D001-1VALVE MODEL.481-S Copy from L-5

Page 24 of 26

References P&IDand/or balance

Remarks No.

VINA L-2 PVC-4 CAUSE NO. SIZE TYPE PRICE(THB)FCV-316A-1/2 FCV-316A-1/2 Obsolete 2 10 BUTTERFLY 500,000FCV-503 FCV-502 Open 92% 1 4 GLOBE 400,000FCV-506A/B HCV-501A/B Body leak 2 2 1/2 V-BALL 250,000LCV-803 LCV-803 Open > 100% 1 1 GLOBE 100,000PCV-404 TCV-402 Damage 1 8 GLOBE 800,000TCV-301A/B-1 TCV-301A/B-1 Obsolete 2 8 BUTTERFLY 450,000TCV-301A/B-2 TCV-301A/B-2 Obsolete 2 6 BUTTERFLY 450,000TCV-401-1 TCV-401-1 Damage 1 3 GLOBE 300,000TCV-401-2 TCV-401-2 Damage 1 1 GLOBE 100,000XSV-312A/B XSV-312A/B Expand pipe size 2 2 BALL 100,000XSV-313A/B XSV-313A/B Expand pipe size 2 2 BALL 100,000TCV-501 TCV-501 Open 95% 1 8 GLOBE 800,000FCV-511 FCV-504 Open > 100% 1 6 GLOBE 550,000

TOTAL 19

SpareXSV-111

XSV-309A/B

* รอ Update รายการซื้��อใหม่�ก บ ACK

AMOUNT1,000,000

400,000500,000100,000800,000900,000900,000300,000100,000200,000200,000800,000550,000

6,750,000