Post on 21-Jun-2020
www.novaestetyc.it
ABDOMEN
FirmingModelling (lipolysis)Stretch marks
FACE
Lifting effectAnti-wrinkle action Face contourredefinition
“Double chin”reduction
FACE - 4RFH
ResurfacingWrinklesAcneScar
“Barcode” wrinkles“Crow’s feet”
ARMS
FirmingModelling (lipolysis)Stretch marks
“Bat wings”
Your Med-Spa enhancer atTHE SERVICE OF BEAUTY
• RADIO4™ DYNAMIC QUADRIPOLAR RADIOFREQUENCY • FACE-BODY TREATMENTS• HAND-PIECE WITH INTEGRATED MOVEMENT SENSOR• PYROMETRIC SENSOR FOR A CONTINUOUS TEMPERATURE MONITORING• COMPLETELY PAINLESS AND COMFORTABLE TREATMENTS• IMMEDIATE AND VISIBLE RESULTS FROM THE FIRST SESSION• LONG LASTING EFFECTS
CONFIGURABLEMODULAR
BUTTOCKS
FirmingModelling (lipolysis)Stretch marks
“Saddlebags”
THIGHS
FirmingModelling (lipolysis)Stretch marks
KNEES
FirmingModelling (lipolysis)
HIPS
FirmingModelling (lipolysis)Stretch marks
“Love handles”
• Localized fat • Cellulite
• Lifting • Firming
• Wrinkles• Hyperpigmentations• Thickened Tissue
• Acne• Scars• Stretch marks
Dyn
amic
Qua
drip
olar
Tec
hEFFECTIVE SAFE INNOVATIVE
EPIDERMIS
DERMIS
HYPODERMIS
YOUR ALL-IN-ONE BEAUTY ENHANCER FOR FULL BODY TREATMENTS!
A platform that works through the combination of different technologies derived from the RADIO4™ Dynamic Quadripolar Technology.
Today the new beauty station is LIFT-SHAPE: a source of complete beauty with proven results. It contrasts the signs of aging, reduces localized fat and improves the P.E.F.S. condition.
YOUR MODULAR SYSTEM!Unique and completely manageable to suit your needs; it offers different configurations and the possibility to be updated and upgraded in time.
A VARIETY OF HANDPIECES FOR EVERY SPECIFIC TREATMENT:
DYNAMIC QUADRIPOLAR RADIOFREQUENCY
This technology, property of Novavision Group, is based on the Dynamic Quadripolar energy emission, which focuses the action on the targeted layer of the tissue - epidermis, dermis or hypodermis - by means of a self-guided system, thus reducing drastically the power usage compared to traditional devices and virtually eliminating the risk of burns. The skin is treated safely, comfortably and efficiently.
THE UNIVERSITY OF PAVIADEPARTMENT OF SURGICAL SCIENCEPLASTIC SURGERY SECTION
LIFT-SHAPE™ is supplied with medical-scientific protocols created in collaboration with:
40°
35°
30°
TEMPERATURE °C Thermal detection evidently shows the efficacy of the RADIO4™ technology, which focuses the action towards the point being worked on.
D y n a m i c Q u a d r i p o l a r Te c h
Small AreasHandle
Medium AreasHandle
Large AreasHandle
4RFHHandle
R E D E F I N E S - R E S U R F A C I N G - R E M O D E L S - B O D Y C O N T O U R I N G - F I R M I N G - L I F T I N G E F F E C T - M O D E L L I N G - T O N E - U P - S T R E T C H M A R K S - C E L L U L I T E
LIFT-SHAPE, with the use of the fractional handpiece, selectively vaporizes micro-areas of the epidermis, accelerating the physiological cellular turnover. Due to the skin resurfacing process, it is used to effectively treat thickened tissue, wrinkles, hyperpigmentations, acne, scars, stretch marks.
«NEW SKIN» EFFECT- FACE, NECK, NECKLINE WRINKLES- HYPERCHROMATIC SPOTS- ACNE- STRETCH MARKS AND SCARS
EPIDERMIS
INN
OVA
TIVE
TEC
HN
OLO
GY
Pins
Zona di riscaldamento e vaporizzazione cellule
Area preservata dal riscaldamento
4RFH PINS DIAGRAM Thermal camera image
Example of matrix detected with high definition camera
RADIOFREQUENCY FRACTIONAL HANDPIECE CONTINUOUS RESEARCH AND INNOVATION
Fractional RF hand-piece with 32 gold plated pins, each with 12 contact points, for a total of 384 µNeedles™
configurable by the software.Each pin has a calibrated pressure system to go beyond the Stratum Corneum.Removable and autoclavable handle tip for easy cleaning and maintenance.
BEFORE AFTER BEFORE AFTER
BLEMISH
NO. OF SESSIONS
“BARCODE” wrinkles
RESULTS AFTER 6 SESSIONS
FACE TREATMENT - 4RFH HANDLE
BLEMISH
NO. OF SESSIONS
ACNE
RESULTS AFTER 3 SESSIONS
FACE TREATMENT - ACNE
EP
ID
ER
MI
S
R E D E F I N E S - R E S U R F A C I N G - R E M O D E L S - B O D Y C O N T O U R I N G - F I R M I N G - L I F T I N G E F F E C T - M O D E L L I N G - T O N E - U P - S T R E T C H M A R K S - C E L L U L I T E
Cells heating and vaporisation zone
Area preserved from heat
Pins
DERMIS
The temperature increase in the dermis causes an immediate TIGHTENING EFFECT due to the “denaturation” of the existing collagen and elastin fibres, which become shorter and thicker. This is the start of the process which will stimulate the fibroblasts to produce more collagen and more elastin, for newly tightened and firmer tissue.
TOTAL BODY LIFTING AND FIRMING EFFECT - FACE, NECK, DÉCOLLETÉ- ARMS, HANDS, ABDOMEN, HIPS, BACK- BUTTOCKS AND SUBGLUTEUS, THIGHS AND INNER THIGHS, KNEES, ANKLES
BEFORE AFTER AFTERBEFORE
Example of temperature detected with high definition thermal camera
BLEMISH NECK WRINKLES
NO. OF SESSIONS RESULTS AFTER 8 SESSIONS
FACE TREATMENT - WRINKLES
BLEMISH
NO. OF SESSIONS
INNER THIGH
RESULTS AFTER 7 SESSIONS
BODY TREATMENT - CELLULITE FLAWS
VARIABLE RADIOFREQUENCYTHE VARIABILITY WHICH MAKES THE DIFFERENCE!The exclusive VRF™ technology, with its range of pre-set frequences, allows the energy to be focused deep in the skin, leaving the outer layer safe from any temperature increase that may be needed to achieve the desired results.Treating dermis and hypodermis in complete safety conditions is now possible with the combined synergy of the VRF and RADIO4™ technologies.
DE
RM
IS
R E D E F I N E S - R E S U R F A C I N G - R E M O D E L S - B O D Y C O N T O U R I N G - F I R M I N G - L I F T I N G E F F E C T - M O D E L L I N G - T O N E - U P - S T R E T C H M A R K S - C E L L U L I T E
The exclusive frequency variability of LIFT-SHAPE causes a volumetric and localized thermal increase in the hypodermis level, causing the exudation of Glycerol and Free Fatty Acids (FFA) from the adipocytes, which are thus reduced in volume.
LOCALIZED FATCELLULITEBODY CONTOURING- UNDER-CHIN, ARMS, BACK, ABDOMEN- HIPS, BUTTOCKS AND SUBGLUTEUS- THIGHS AND INNER THIGHS, KNEES
HYPODERMIS
RADIOFREQUENCY SAFELY SYSTEMSAFETY AND EFFICACY FIRSTThe RSS™, property of Novavision Group, enables the opera-tor to unleash the full potential of the LIFT-SHAPE in a safe and controlled manner. Actually each hand-piece is equipped with a movement sensor system, which allows the operator to work in total safety, preventing excessive stops or incorrect motions in order to avoid harmful administration of heat to the tissue. Besides the temperature detection system with pyrometric infrared sensors constantly monitors the progression to reach the optimal temperature level,while safeguarding the tissue from excessive increases. This safety feature can automatically shut-down the emission of energy should it detect any possible risk.
AFTERBEFORE
BLEMISH
NO. OF SESSIONS
ABDOMEN (MAN)
RESULTS AFTER 6 SESSIONS
BODY TREATMENT - ADIPOSE TISSUE
AFTERBEFORE
BLEMISH
NO. OF SESSIONS
ABDOMEN (WOMAN)
RESULTS AFTER 4 SESSIONS
BODY TREATMENT - ADIPOSE TISSUE
HY
PO
DE
RM
IS
COMBINED ACTIONFOR PERFECT EFFICACY!
R E D E F I N E S - R E S U R F A C I N G - R E M O D E L S - B O D Y C O N T O U R I N G - F I R M I N G - L I F T I N G E F F E C T - M O D E L L I N G - T O N E - U P - S T R E T C H M A R K S - C E L L U L I T E
TECHNICAL SPECIFICATIONS
DESCRIPTION SPECS
POWER SUPPLY 90 – 240Vac 50/60Hz - 150 VA
RF FREQUENCY 1 MHz dynamic quadripolar with VRF
POWER 25W
POWER ADJUSTMENT digital from 5% to 100%
DIMENSIONS L 57 x H 103,5 x W 48 cm
WEIGHT 21 Kg
All specs are subject to change without notice
20826 Misinto (MB) Milano - Italy - Via dei Guasti, 29 tel. +39 02 96720240 - fax +39 02 96720232info@novaestetyc.it
DB.PB.0551 R3
www.novaestetyc.it