  • 31

    45

    2

    aFit closure flashingusing low profilefasteners. An air sealconsisting of anunbroken 6mm Øbead of gun-gradesealant is requiredbetween supportangle and floor

    bLine, level and fix drip flashing using low profile fasteners. Joints in the dripflashing to incorporate butt straps sealed with two runs of gun-grade sealant

    cApply an unbroken 6mm Ø bead of gun-grade sealant toprovide an air seal between back of panel and closure flashing

    dGalvanised angle & rail extensions to be installed to provide suitablebearing for fixing of panels on return elevation, by a steel fabricator

    fApply an unbroken 6mm Øbead of gun-grade sealant togalvanised angle ensuring itmeets the previously installedair seals

    gLocate first panel (P1)ensuring it is correctlypositioned lined and levelled

    hInstall min. 2 No. main

    fasteners through the malejoint at the top, intermediate

    and bottom locations

    Note: Some installations may requireadditional fasteners depending on windloadings/specifications. Check project

    specific details.

    iAt corner positions, throughfix countersunk fastenersat 500mm max. centresinto female panel joint

    Note: Fasteners to be suitably located toensure they are covered by external cornerflashing. Also applicable at door/window

    jamb abutments.

    eApply an unbroken 6mm Øbead of gun-grade sealant totop rail or internal flashing to

    provide an air seal

    jRun a gun-grade air seal across male jointensuring it meets previously installed air seal

    lLocate next panel (P2) into position

    ensuring that the factory applied weatherseal is compressed and that the AWP fillerremains in position. Ensure panel is linedand levelled correctly in line with adjacent

    panel install min. 2 No. main fastenersthrough the male joint at the top,intermediate and bottom locations

    mRepeat processes j to l to

    complete elevation

    nInstall site applied PIR insulationboard and gun applied fire rated

    canister insulation into female jointto fill the gap between panels

    (P1) and (P5) to ensurecontinuity of insulation

    oCut panel (P5) to size usingan evolution type circular saw,ensuring it meets the outside

    edge of (P1)

    Note: Do not use abrasive wheel cutter.All cutting should be done at ground level.

    pLocate panel (P5) in to position

    ensuring factory applied weather sealis compressed and AWP filler

    remains in position

    qAt corner positions, through fixcountersunk fasteners at 500mm

    max. centres in to panel (P5) at cutedge of panel

    Note: Fasteners to be suitably located to ensurethey are covered by external corner flashing.

    sApply 4mm Ø butyl sealant (site applied) to theexternal legs of the internal corner flashing, ensuresealant is positioned weather side of fasteners

    rApply 4mm Ø butyl sealant (site applied) to theback of the internal corner flashing, ensure sealantis positioned weather side of fastener. Fix internalcorner flashing with low profile stitching screws atmax. 450mm centre

    tFix external corner flashingwith low profile stitchingscrews at max. 450mm

    centres positioned as perdetail. Joints in the cornerflashing to incorporate buttstraps sealed with two runs

    of gun-grade sealant

    AWP filler beddedon silicone sealantat every horizontalpanel joint

    Run of gun-grade air sealacross male joint

    Stanchion

    Sheeting rail

    Optional internal closureflashing to mask insulation

    from view

    PIR insulation board

    Air seal - continuous beadof gun-grade sealant

    The gap betweenthe panel and the drip

    flashing needsto be 6mm minimum

    P1

    P1P5 P2

    P3P4

    P1 P2

    Benchmark Karrier Panelinsulated wall panel vertically laid

    Air seal - 6mm Øbead of gun-grade

    sealant, as per item l

    Note:The structure should be suitably designed to suitboth the Benchmark Karrier Panel insulated panel andBenchmark Ceramic Tile Façade System. Ensure steelwork issuitably lined, levelled and within tolerance.Visually check theinternal liner joint to ensure panels are joined fully.Check panel cover width module as works progress to ensure“creep” does not occur, particularly important when windowsare incorporated into the elevation.Joints need to be aligned correctly during installation toprevent the ‘saw tooth’ effect at the drip.Gun-grade sealant type – non-setting butyl sealant

    – silicone sealant.This is a generic Benchmark Karrier Panel wall installationguide and details may differ from project to project.Project specific construction details must be used. Pleasecontact Kingspan envirocare® technical services for furtherinformation on 0800 587 0090.

    Drip flashing50mm

    Verge flashing with150mm sealed butt straps

    Site applied PIRinsulation or gunapplied fire ratedcanisterinsulation

    20mm x 3mm butylrubber sealant

    Cleader angle by steel sub-contractor with air seal Vapourflex

    sealant applied at joints

    KS1000 LP insulatedroof panel

    Air seal - 8mm Øapprox. gun-grade

    sealant

    4mm Ø butylrubber sealant

    Air seal - 6mm Ø beadof gun-grade sealant

    Benchmark Karrier Panelinsulated wall panelvertically laid

    Verge flashing with150mm sealed butt straps

    Site applied PIRinsulation orgun applied firerated canisterinsulation

    20mm x 3mm butylrubber sealant

    Cleader angle by steel sub-contractor with air seal Vapourflex

    sealant applied at joints

    KS1000 LP insulatedroof panel

    Air seal - 8mm Øapprox. gun-grade

    sealant

    4mm Ø butylrubber sealant

    Air seal - 6mm Ø beadof gun-grade sealant

    Benchmark Karrier Panelvertically laid

    Air seal - 6mm beadof gun-grade sealant

    4mm Ø butylrubber sealant

    Low profile fastener

    External cornerflashing

    Inner cornerflashing

    Gun applied fire ratedcanister insulation

    Edge of verticalpanel site cut

    Galvanised angle

    Air seal - 6mm beadof gun-grade sealant

    4mm Ø butylrubber sealant

    Low profile fastener

    External cornerflashing

    Inner cornerflashing

    Gun applied fire ratedcanister insulation

    Edge of verticalpanel site cut

    Galvanised angle

    This installation guide should be read inconjunction with the ‘project specific’design drawings and method statements.Although this ‘installation guide’ is deemedto be correct at the time of publication,Kingspan Benchmark reserve the right toamend the information at any time in thefuture. Installation Guides are available forthe full range of Roof, Wall & FaçadeSystems.Tel: 01352 716100Fax: 01352 710161Email: info@kingspanbenchmark.com

    Benchmark Karrier PanelComponents

    6mm Ø

    Primary/MainFastener

    Gun-GradeSealant

    PIRInsulation

    ClosureFlashing

    AWP Filler

    4mm Ø 20 x 3mm

    Fire-ratedCanisterInsulation

    SiliconeSealant

    External CornerFlashing

    Internal CornerFlashing

    Counter SunkMain Fastener

    Drip Flashing

    Secondary/Stitching Screw

    Low ProfileFastener

    Closure flashing withlap joints air sealed

    Air seal - 6mm Ø beadof gun-grade sealant

    Direction of

    layDirect

    ion oflay

    Direction of lay

    Direction of

    lay

    Direction of lay

    Direction of

    lay

    kBed an AWP filler in silicone sealant at topof panel only, and run a gun-grade air sealacross male joint ensuring it meetspreviously installed air seal

    Note: Position of AWP filler at top of panel (parapet/bottomof window) needs to reflect project specific details in order toachieve airtightness performance.

    Run of gun-grade air sealacross male joint

    Air seal - Vapourflexsealant applied overjoints in supports

    Air seal - 6mm beadof gun-grade sealant

    Air seal - 6mm beadof gun-grade sealant

    4mm Ø butylrubber sealant

    AWP joint filler andgun-grade sealant

    Air seal - gun-grade sealantat male panel joint

    Air seal - gun-gradesealant at male

    panel joint

    Gun applied firerated canister

    insulation on site

    Drip flashing

    Stack Joint Detail

    Benchmark KarrierPanel insulated wallpanel vertically laid

    Benchmark Karrier Panelinsulated wall panel vertically laid

    Note: Care should be taken to ensure that the stack jointdetail does not coincide with a support rail position.

    Butyl RubberTape Sealants

    KARRIER PANELInsulatedWall Panel VerticallyLaid Installed On MultibeamPurlin & Rail System

    July 2010