1+1 HSB SD FD Commissioning

Post on 29-Nov-2015

817 views 17 download

Tags:

Transcript of 1+1 HSB SD FD Commissioning

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Security Level:

www.huawei.com

1+1 HSB-FD-SD Commissioning

CONTENT

• Basic Knowledge• 1+1 HSB• 1+1 FD• 1+1 SD

HUAWEI TECHNOLOGIES CO., LTD. Page 3Huawei Confidential

Basic Knowledge• 1+1 Configuration

For RTN 620, the paired slots (slot5 and slot7) consist a 1+1 protection group; the paired slots (slot6 and slot8) consist another 1+1 protection group.

Slot 5 and slot 6 is main slot respectively.

For 1+1 HSB and SD application, It is only necessary to configure main IF board parameters.

For 1+1 FD application, It is necessary to configure main parameters and standby parameters respectively.

HUAWEI TECHNOLOGIES CO., LTD. Page 4Huawei Confidential

Basic Knowledge• Trigger Conditions of the automatic HSB switching

The IF connection cable is faulty.

MW_LOF

R_LOS

R_LOF

R_LOC

CONFIG_NOSUPPORT

IF_INPWR_ABN

RADIO_RSL_HIGH

RADIO_TSL_LOW

RADIO_TSL_HIGH

VOLT_LOS(IF Board)POWER_FAIL

The hardware of the ODU is faulty.

At the same priority.

The hardware of the IF board is faulty.

DescriptionSwitching Conditions

HUAWEI TECHNOLOGIES CO., LTD. Page 5Huawei Confidential

Basic Knowledge• Trigger Conditions of the automatic HSM switching

MW_BER_SD(IDU 605 2B/2F)B2_SD (IDU 620 SDH ) Low

B1_SD (IDU 620 PDH)

MediumMW_FECUNCOR

MW_LOF

R_LOS

R_LOFHigh

R_LOC

DescriptionSwitching Conditions

HUAWEI TECHNOLOGIES CO., LTD. Page 6Huawei Confidential

Basic Knowledge

Application

ODU port insertion loss, db max:3.8 (38G:4.0).

with equal attenuation in both channels

Symmetrical Hybrid Coupler (3dB)

Main ODU port insertion loss, dB max:1.8 (38G: 2.0);Standby ODU port insertion loss, dB max: 7.2 (38G:7.4)

with one main channel and one standby channel.

Asymmetrical Hybrid Coupler(6dB)

Receive PowerDescriptionCoupler Type

• Hybrid Coupler with Waveguide Interface

HUAWEI TECHNOLOGIES CO., LTD. Page 7Huawei Confidential

Basic Knowledge• Trigger Conditions and Antenna Aligning

Alarms R_LOF,R_LOS,MW_LOF are the microwave link alarm.

While aligning antennas, the microwave link is not stable, will create these alarms.

In order to finish antennas aligning quickly, for 1+1 application, we suggest turn off the standby IF ODU-PWR switch at first, after antenna aligning finishing, turn on the standby IF ODU-PWR.

HUAWEI TECHNOLOGIES CO., LTD. Page 8Huawei Confidential

Basic Knowledge

√√

102

2SD

_1/01Quantity of Hybrid Coupler

_1/21Quantity of Antenna

HSB/SD: main ODU type is same as standby.

22Quantity of ODU

—√√HSB Support

HSB/SD: Only configure main IF parameters.FD: Configure main and standby IF parameters respectively.

21Quantity of Frequency Channel

—√×HSM Support

NotesFDHSBItem

• 1+1 HSB/FD/SD Compare

CONTENT

• Basic Knowledge• 1+1 HSB• 1+1 FD• 1+1 SD

HUAWEI TECHNOLOGIES CO., LTD. Page 10Huawei Confidential

1+1 HSB Commissioning• 1+1 HSB Commissioning Steps

Link 1+1 Configure

ParametersConfigure

Turn off Standby IF ODU-PWR

SwitchAlign Antenna

Turn on Standby IF ODU-PWR

Switch

1+1 Switch State and Test

HUAWEI TECHNOLOGIES CO., LTD. Page 11Huawei Confidential

1+1 HSB Commissioning• Link 1+1 Configure

To Next Page

HUAWEI TECHNOLOGIES CO., LTD. Page 12Huawei Confidential

1+1 HSB Commissioning• Link 1+1 Configure

HUAWEI TECHNOLOGIES CO., LTD. Page 13Huawei Confidential

1+1 HSB Commissioning• IP Parameters Configure

For 1+1 HSB, only configure main IF board parameters.

HUAWEI TECHNOLOGIES CO., LTD. Page 14Huawei Confidential

1+1 HSB Commissioning• Query 1+1 HSB Switch State

Switch State

HUAWEI TECHNOLOGIES CO., LTD. Page 15Huawei Confidential

1+1 HSB Commissioning• 1+1 Switch Control

Right Click

CONTENT

• Basic Knowledge• 1+1 HSB• 1+1 FD• 1+1 SD

HUAWEI TECHNOLOGIES CO., LTD. Page 17Huawei Confidential

1+1 FD Commissioning

Link 1+1 Configure

ParametersConfigure

Turn off Standby IF ODU-PWR

SwitchAlign Antenna

Turn on Standby IF ODU-PWR

Switch

1+1 Switch State and Test

• 1+1 FD Commissioning Steps

HUAWEI TECHNOLOGIES CO., LTD. Page 18Huawei Confidential

1+1 FD Commissioning• Link 1+1 Configure

HUAWEI TECHNOLOGIES CO., LTD. Page 19Huawei Confidential

1+1 FD Commissioning• IF Parameters Configure

④⑤

⑥ ⑦

HUAWEI TECHNOLOGIES CO., LTD. Page 20Huawei Confidential

1+1 FD Commissioning• IF Parameters Configure

④⑤

⑥ ⑦

CONTENT

• Basic Knowledge• 1+1 HSB• 1+1 FD• 1+1 SD

HUAWEI TECHNOLOGIES CO., LTD. Page 22Huawei Confidential

1+1 SD Commissioning• 1+1 SD Commissioning Steps

Link 1+1 Configure

IF ParametersConfigure

Turn off Standby IF ODU-PWR

Switch

Align main Antenna

Turn on Standby IF ODU-PWR

Switch

Align Standby Antenna

HUAWEI TECHNOLOGIES CO., LTD. Page 23Huawei Confidential

1+1 SD Commissioning• 1+1 Link Configure

HUAWEI TECHNOLOGIES CO., LTD. Page 24Huawei Confidential

1+1 SD Commissioning• Parameters Configure

For 1+1 SD, only configure main IF board parameters.

HUAWEI TECHNOLOGIES CO., LTD. Page 25Huawei Confidential

1+1 SD CommissioningTurn off two side standby ODU's power, turn on two main ODU's power, firstly, align two main antennas.

√: ODU Power on.X: ODU Power off.

HUAWEI TECHNOLOGIES CO., LTD. Page 26Huawei Confidential

1+1 SD CommissioningTurn on local site standby ODU's power, keep opposite site main antenna fixed, align local standby antenna towards opposite main one.

√: ODU Power on.X: ODU Power off.

HUAWEI TECHNOLOGIES CO., LTD. Page 27Huawei Confidential

1+1 SD CommissioningTurn on opposite standby ODU's power, keep local main antenna fixed, align opposite standby antenna towards local main one.

√: ODU Power on.X: ODU Power off.

Thank youwww.huawei.com