Post on 29-Nov-2015
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Security Level:
www.huawei.com
1+1 HSB-FD-SD Commissioning
CONTENT
• Basic Knowledge• 1+1 HSB• 1+1 FD• 1+1 SD
HUAWEI TECHNOLOGIES CO., LTD. Page 3Huawei Confidential
Basic Knowledge• 1+1 Configuration
For RTN 620, the paired slots (slot5 and slot7) consist a 1+1 protection group; the paired slots (slot6 and slot8) consist another 1+1 protection group.
Slot 5 and slot 6 is main slot respectively.
For 1+1 HSB and SD application, It is only necessary to configure main IF board parameters.
For 1+1 FD application, It is necessary to configure main parameters and standby parameters respectively.
HUAWEI TECHNOLOGIES CO., LTD. Page 4Huawei Confidential
Basic Knowledge• Trigger Conditions of the automatic HSB switching
The IF connection cable is faulty.
MW_LOF
R_LOS
R_LOF
R_LOC
CONFIG_NOSUPPORT
IF_INPWR_ABN
RADIO_RSL_HIGH
RADIO_TSL_LOW
RADIO_TSL_HIGH
VOLT_LOS(IF Board)POWER_FAIL
The hardware of the ODU is faulty.
At the same priority.
The hardware of the IF board is faulty.
DescriptionSwitching Conditions
HUAWEI TECHNOLOGIES CO., LTD. Page 5Huawei Confidential
Basic Knowledge• Trigger Conditions of the automatic HSM switching
MW_BER_SD(IDU 605 2B/2F)B2_SD (IDU 620 SDH ) Low
B1_SD (IDU 620 PDH)
MediumMW_FECUNCOR
MW_LOF
R_LOS
R_LOFHigh
R_LOC
DescriptionSwitching Conditions
HUAWEI TECHNOLOGIES CO., LTD. Page 6Huawei Confidential
Basic Knowledge
Application
ODU port insertion loss, db max:3.8 (38G:4.0).
with equal attenuation in both channels
Symmetrical Hybrid Coupler (3dB)
Main ODU port insertion loss, dB max:1.8 (38G: 2.0);Standby ODU port insertion loss, dB max: 7.2 (38G:7.4)
with one main channel and one standby channel.
Asymmetrical Hybrid Coupler(6dB)
Receive PowerDescriptionCoupler Type
• Hybrid Coupler with Waveguide Interface
HUAWEI TECHNOLOGIES CO., LTD. Page 7Huawei Confidential
Basic Knowledge• Trigger Conditions and Antenna Aligning
Alarms R_LOF,R_LOS,MW_LOF are the microwave link alarm.
While aligning antennas, the microwave link is not stable, will create these alarms.
In order to finish antennas aligning quickly, for 1+1 application, we suggest turn off the standby IF ODU-PWR switch at first, after antenna aligning finishing, turn on the standby IF ODU-PWR.
HUAWEI TECHNOLOGIES CO., LTD. Page 8Huawei Confidential
Basic Knowledge
√√
102
2SD
_1/01Quantity of Hybrid Coupler
_1/21Quantity of Antenna
HSB/SD: main ODU type is same as standby.
22Quantity of ODU
—√√HSB Support
HSB/SD: Only configure main IF parameters.FD: Configure main and standby IF parameters respectively.
21Quantity of Frequency Channel
—√×HSM Support
NotesFDHSBItem
• 1+1 HSB/FD/SD Compare
CONTENT
• Basic Knowledge• 1+1 HSB• 1+1 FD• 1+1 SD
HUAWEI TECHNOLOGIES CO., LTD. Page 10Huawei Confidential
1+1 HSB Commissioning• 1+1 HSB Commissioning Steps
Link 1+1 Configure
ParametersConfigure
Turn off Standby IF ODU-PWR
SwitchAlign Antenna
Turn on Standby IF ODU-PWR
Switch
1+1 Switch State and Test
HUAWEI TECHNOLOGIES CO., LTD. Page 11Huawei Confidential
1+1 HSB Commissioning• Link 1+1 Configure
To Next Page
①
②
③
④
HUAWEI TECHNOLOGIES CO., LTD. Page 12Huawei Confidential
1+1 HSB Commissioning• Link 1+1 Configure
HUAWEI TECHNOLOGIES CO., LTD. Page 13Huawei Confidential
1+1 HSB Commissioning• IP Parameters Configure
①
②
③
④
⑤
For 1+1 HSB, only configure main IF board parameters.
HUAWEI TECHNOLOGIES CO., LTD. Page 14Huawei Confidential
1+1 HSB Commissioning• Query 1+1 HSB Switch State
①
②
④
③
Switch State
HUAWEI TECHNOLOGIES CO., LTD. Page 15Huawei Confidential
1+1 HSB Commissioning• 1+1 Switch Control
①
②
④
③
Right Click
CONTENT
• Basic Knowledge• 1+1 HSB• 1+1 FD• 1+1 SD
HUAWEI TECHNOLOGIES CO., LTD. Page 17Huawei Confidential
1+1 FD Commissioning
Link 1+1 Configure
ParametersConfigure
Turn off Standby IF ODU-PWR
SwitchAlign Antenna
Turn on Standby IF ODU-PWR
Switch
1+1 Switch State and Test
• 1+1 FD Commissioning Steps
HUAWEI TECHNOLOGIES CO., LTD. Page 18Huawei Confidential
1+1 FD Commissioning• Link 1+1 Configure
HUAWEI TECHNOLOGIES CO., LTD. Page 19Huawei Confidential
1+1 FD Commissioning• IF Parameters Configure
①
②
③
④⑤
⑥ ⑦
⑧
HUAWEI TECHNOLOGIES CO., LTD. Page 20Huawei Confidential
1+1 FD Commissioning• IF Parameters Configure
①
②
④⑤
⑥ ⑦
⑧
③
CONTENT
• Basic Knowledge• 1+1 HSB• 1+1 FD• 1+1 SD
HUAWEI TECHNOLOGIES CO., LTD. Page 22Huawei Confidential
1+1 SD Commissioning• 1+1 SD Commissioning Steps
Link 1+1 Configure
IF ParametersConfigure
Turn off Standby IF ODU-PWR
Switch
Align main Antenna
Turn on Standby IF ODU-PWR
Switch
Align Standby Antenna
HUAWEI TECHNOLOGIES CO., LTD. Page 23Huawei Confidential
1+1 SD Commissioning• 1+1 Link Configure
HUAWEI TECHNOLOGIES CO., LTD. Page 24Huawei Confidential
1+1 SD Commissioning• Parameters Configure
①
②
③
④
⑤
For 1+1 SD, only configure main IF board parameters.
HUAWEI TECHNOLOGIES CO., LTD. Page 25Huawei Confidential
1+1 SD CommissioningTurn off two side standby ODU's power, turn on two main ODU's power, firstly, align two main antennas.
√: ODU Power on.X: ODU Power off.
HUAWEI TECHNOLOGIES CO., LTD. Page 26Huawei Confidential
1+1 SD CommissioningTurn on local site standby ODU's power, keep opposite site main antenna fixed, align local standby antenna towards opposite main one.
√: ODU Power on.X: ODU Power off.
HUAWEI TECHNOLOGIES CO., LTD. Page 27Huawei Confidential
1+1 SD CommissioningTurn on opposite standby ODU's power, keep local main antenna fixed, align opposite standby antenna towards local main one.
√: ODU Power on.X: ODU Power off.
Thank youwww.huawei.com