FACP
FSCU
VS
WF
FAA
DH
2E4.2
F FIRE ALARM PULL STATION. WALL MOUNTED WITH OPERABLEPART OF THE DEVICE AT 46" AFF.
FIRE ALARM SIGNAL, SPEAKER AND FLASHING LIGHT, 80" AFF TOTHE BOTTOM OF THE LINES. "C" DESIGNATION INDICATESCEILING MOUNTED.
FIRE ALARM STROBE LIGHT, 80" AFF TO THE BOTTOM OF THE LENS.
FIRE ALARM CONNECTION, HOOD EXTINGUISHING SYSTEM, SEEMECHANICAL DRAWINGS FOR LOCATION. INTERLOCK WITHSHUNT TRIP BREAKERS FOR EQUIPMENT UNDER HOOD.
FIRE ALARM REMOTE LCD ANNUNCIATOR PANEL. FLUSHRECESSED WALL MOUNTED.
FIRE ALARM DOOR HOLDER, WALL MOUNTED, CONSULTARCHITECTURAL DRAWINGS TO DETERMINE TYPE REQUIRED.PROVIDE POWER FROM NEAREST RECEPTACLE CIRCUIT ANDCONNECT TO FIRE ALARM SYSTEM.
TAMPER SWITCH, FURNISHED AND INSTALLED WITH SPRINKLERSYSTEM. INTERLOCK WITH FIRE ALARM SYSTEM BY ELECTRICAL.
FLOW SWITCH, FURNISHED AND INSTALLED WITH SPRINKLERSYSTEM. INTERLOCK WITH FIRE ALARM SYSTEM BY ELECTRICAL.
FIRE ALARM SMOKE DETECTOR, CEILING MOUNTED.
FIRE ALARM DUCT SMOKE DETECTOR LOCATED IN HVAC DUCT.
FIRE ALARM CONTROL PANEL, SURFACE WALL MOUNTED.
FIRE ALARM SIGNAL, HORN. 90" AFF TO THE TOP OF THE DEVICE.WEATHER PROOF.
FIRE ALARM HEAT DETECTOR, 135 DEG, OPERATION.
FIRE ALARM STROBE LIGHT, CEILING MOUNTED.
S
M
FIRE ALARM:
H
S WP
IC
AD
AC
S
2.
COORDINATE MOUNTING HEIGHTS, DEVICE LOCATIONS & POWER/CONTROL REQUIREMENTSWITH ARCHITECTURAL DRAWINGS AND SYSTEM INSTALLER.
INTRUSION DETECTION SYSTEM:
CONDUIT SLEEVE: NUMBER & SIZE, (2)-2" FOR ALL CLASSROOMS,(1)-2" FOR ALL OFFICES, UNO
CABLE TRAY: SIZE AS INDICATED, 18"W x 4"H TYP.
INTERCOM SPEAKER: WEATHERPROOF WALL MOUNTED AT 96"AFF.
MICROPHONE JACK: WALL MOUNTED AT 18" AFF, UNO.
PUSH BUTTON EMERGENCY CALL STATION: 46" AFF, UNO.
ADMINISTRATIVE DISPLAY PHONE: WALL MOUNT AT 46" AFF
INTRUSION SYSTEM: KEY-PAD, MOUNT 48"AFF
INTRUSION DETECTION DEVICE: WALL MTD.
ACCESS CONTROL SYSTEMS
SEE DETAIL 2/T3.0 FOR POWER, POWER DISCONNECT, LOWVOLTAGE CABLING, BOXES AND CONDUIT REQUIREMENTS.REFER TO ARCHITECTURAL PLANS AND DOOR SPECIFICATIONSFOR ADDITIONAL REQUIREMENTS.
INTERCOM SPEAKER: 2' X 2' SQUARE CEILING MOUNTED
COORDINATE MOUNTING HEIGHTS, DEVICE LOCATIONS & POWER/CONTROL REQUIREMENTSWITH ARCHITECTURAL DRAWINGS AND SYSTEM INSTALLER.
SPEAKER SYSTEM:
CABLING COMPONENTS:
THE CONTRACTOR SHALL PROVIDE ROUGH-IN FOR ALL DEVICES AND WIRING.ROUGH-IN REQUIREMENTS ARE SPECIFIED IN SECTION 261010. VERIFY ADJACENCYTO CORRESPONDING POWER RECEPTACLES. OTHER DEVICES WHOSE LOCATIONSARE NOT DEPENDENT ON RECEPTACLE PLACEMENT SHALL BE COORDINATED WITHSYSTEM INSTALLER.
WALL MTD. TELECOMMUNICATION JUNCTION BOX ANDCONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING
CEILING MTD. TELECOMMUNICATION JUNCTION BOX
WALL MTD. TELECOMMUNICATION JUNCTION BOX ANDCONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING
CEILING MTD. TELECOMMUNICATION JUNCTION BOX ANDCONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING
WALL MTD. TELECOMMUNICATION JUNCTION BOX ANDCONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING
ROUGH-IN FOR LOW VOLTAGE SYSTEMS:
KP
PC
XX-1
T
M
ABBREVIATIONS:
LEGEND:
LIGHTING FIXTURES: ELECTRICAL EQUIPMENT:
GENERAL NOTES:
BRANCH CIRCUITS:
CONDUCTOR COUNTS ARE SHOWN ON THE HOMERUNS ONLY. CONTRACTOR SHALLDETERMINE COUNTS FOR INTERMEDIATE RUNS BASED ON THE MANNER IN WHICH THECIRCUIT ELEMENTS ARE CONNECTED. REFER TO THE SPECIFICATION SECTIONS 262010,262080, & 26030 FOR SPECIAL REQUIREMENTS.
LA-1,3,5
SWITCH: MOTOR RATED, WITHOUT OVERLOAD PROTECTION
DISCONNECT SWITCH
DRY-TYPE TRANSFORMER
PANELBOARD: SURFACE MOUNTED
EQUIPMENT AS NOTED, SEE ABBREVIATIONS, THIS SHEET
PHOTOCELL: LOCATE UNDER EAVES, FACING NORTH,AVOID ANY OTHER OUTSIDE LIGHT SOURCE
BRANCH CIRCUIT: CONCEALED
BRANCH CIRCUIT: CONCEALED IN FLOOR SLAB
BRANCH CIRCUIT: EXPOSED
'HOMERUN' TO PANEL: NUMBER OF HASH MARKS INDICATESQUANTITY OF No. 12 AWG UNGROUNDED CONDUCTORS IN 3/4"RACEWAY. GROUNDED CONDUCTORS (NEUTRALS) ARE NOTSHOWN - ONE DEDICATED NEUTRAL IS REQUIRED FOR EACHUNGROUNDED CONDUCTOR INSTALLED, SEE SPECIFICATIONS.EACH CONDUCTOR SHALL BE MIN. No. 12 AWG UNLESS NOTEDOTHERWISE.
WHERE COMPLETE BRANCH CIRCUIT WIRING IS NOT SHOWN, PROVIDEACCORDING TO HOMERUNS SHOWN AND CORRESPONDING CIRCUIT NUMBERSADJACENT TO THE DEVICE OR FIXTURE. REFER TO THE SPECIFICATIONS FORTHE WIRING METHODS. BRANCH CIRCUIT RATINGS SHALL BE BASED ONOVERCURRENT DEVICE RATINGS SHOWN IN THE PANEL SCHEDULES.
REFER TO THE ELECTRICAL PANELBOARD SCHEDULES AND EQUIPMENTRATINGS & CONNECTIONS SCHEDULE FOR VOLTAGE, BRANCH CIRCUITSREQUIREMENTS, BREAKERS SIZES AND OTHER RELATED ELECTRICALEQUIPMENT TO BE PROVIDED AND/OR INSTALLED BY THE ELECTRICALCONTRACTOR.
A AMPERES
AFFABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AH AIR HANDLER
AIC AMPERAGE INTERRUPT CAPABILITY
ATU AIR TERMINAL UNIT
A/V AUDIO/VISUAL
AWG AMERICAN WIRE GAUGE
BFG BELOW FINISHED GRADE
B.E. BOTTOM EDGE
C. CONDUIT
CU CONDENSING UNIT
DAH DUCTLESS AIR HANDLER
DHP DUCTLESS HEAT PUMP
DACS DIGITAL ALARM COMMUNICATOR SYSTEM
DIA. DIAMETER
THE ELECTRICAL DRAWINGS ARE ONLY PART OF THE CONTRACT DOCUMENTS.THE CONTRACTOR SHALL REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONSFOR THEIR INTERRELATIONSHIP AND REQUIRED COORDINATION BETWEENDISCIPLINES.
SYMBOL WHERE SHOWN AT OR NEAR A ROOM INDICATES THATROOM IS SHOWN AS A TYPICAL LARGE SCALE. (2) INDICATESTHE DETAIL NUMBER AND (E4.2) INDICATES THE SHEET NUMBER.
ALL CONDUCTORS SHALL BE COPPER UNLESS NOTED WITH THE WORD"ALUMINUM" IN THE DESCRIPTION.
EACH DOOR SHALL HAVE ONE 3/4"C. FROM DOOR FRAME TO DOORCONTROLLER ENCLOSURE (ASSUME WITHIN 50' OF DOOR), ONE DEDICATED20A, 120 VOLT CIRCUIT TO SAME CONTROLLER ENCLOSURE.
PRIOR TO RUNNING ANY CONDUIT, COORDINATE LOCATIONS OF ALL WALLMOUNTED DEVICES WITH WALL MOUNTED ACOUSTICAL PANELS. SEEARCHITECTURAL DRAWINGS FOR SPACES IN WHICH WALL PANELS AREINSTALLED.
PRIOR TO RUNNING CONDUIT, COORDINATE LOCATIONS OF ALL WALLMOUNTED DEVICES WITH WALL MOUNTED SAFETY PADS IN GYMNASIUM.
1.
3.
4.
5.
6.
E.C.B. ENCLOSED CIRCUIT BREAKER
EF EXHAUST FAN
EH ELECTRIC HEATER
EMCS ENERGY MANAGEMENT CONTROL UNIT
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
G GROUND
GFI GROUND-FAULT INTERRUPTING
HP HORSE POWER
HRVU HEAT RECOVERY VENTILATING UNIT
HWCP HOT WATER CIRCULATING PUMP
KCMIL KILO CIRCULAR MIL
MAH MAKEUP AIR HEATER
MB MAIN BREAKER
MCA MINIMUM CIRCUIT AMPS
MIN MINIMUM
MOCP MAXIMUM OVERCURRENT PROTECTION
MTD MOUNTED
No. NUMBER
NEC NATIONAL ELECTRIC CODE
NTS NOT TO SCALE
PIV POST INDICATOR VALVE
RGS RIGID GALVANIZED STEEL
RTU ROOFTOP UNIT
SF SUPPLY FAN
SPD SURGE PROTECTION DEVICE
SWBD SWITCHBOARD
TGB TELECOMMUNICATIONS GROUND BUS
TMGB TELECOMMUNICATIONS MAIN GROUND BUS
TTW THROUGH-THE-WALL HEAT PUMP
TYP TYPICAL
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
V VOLTAGE
W WATTAGE
W/ WITH
WH WATER HEATER
WHP WALL-MOUNTED HEAT PUMP
WP WEATHER PROOF
XFMR TANSFORMER
SMOKE DAMPER, 120V, PROVIDE POWER CONNECTION AND ALLNEEDED SMOKE DETECTION AND CONTROL MODULES ASREQUIRED BY NFPA 72 FOR PROPER OPERATION.
SD
FIRE ALARM REMOTE VOICE EVACUATION MICROPHONE FLUSHRECESSED WALL MOUNTED.
MIC
S SPEAKER - SEE DRAWINGS AND SPECIFICATIONS FOR TYPE.
LA-1,3,5
'HOMERUN' TO PANEL FOR EQUIPMENT: SEE EQUIPMENTCONNECTION SCHEDULES FOR SIZE OF FEEDER AND NUMBEROF CONDUCTORS.
FIRE ALARM CARBON MONOXIDE DETECTOR, PROVIDE 120 VOLTCONNECTION TO NEAREST UNSWITCHED RECEPTACLE CIRCUIT.
UPPERCASE LETTER ADJACENT TO FIXTURE DENOTES DESIGNATION PER THELIGHTING FIXTURE SCHEDULE. LOWERCASE LETTER DENOTES SWITCHLEG. THERESPECTIVE SWITCH WILL HAVE THE SAME DESTINATIONS. NUMERAL DENOTESBRANCH CIRCUIT CONNECTION.
REFER TO THE FIXTURE SCHEDULE FOR THE SPECIFIC FIXTURE INFORMATION.
EMERGENCY FIXTURES SHALL HAVE FACTORY INSTALLED INTERNAL BATTERIES,PER SPECIFICATIONS.
OS
OS
OS
W
HD
C
RECEPTACLES:
NOMINAL MOUNTING HEIGHT OF RECEPTACLES SHALL BE 18" TO CENTER, UNO. IFAPPLICABLE, ADJUST SO DEVICE COVER IS IN THE CENTER OF MASONRY COURSENEAREST THAT HEIGHT. THE HEIGHT ESTABLISHED SHALL GOVERN FOR ALL BOXINSTALLATIONS, WHERE INSTALLED IN MASONRY OR FRAMED WALLS.
SWITCHES:
MOUNTING HEIGHT OF SWITCHES SHALL BE 46" NOMINAL, ADJUSTED IN THE SAMEMANNER AS SPECIFIED ABOVE, FOR RECEPTACLES. LOWERCASE LETTERINDICATES SWITCHLEG CONNECTION. THE RESPECTIVE FIXTURE(S) WILL HAVE THESAME DESIGNATION.
3
4
a
K
O
RECEPTACLE: SIMPLEX
RECEPTACLE: DUPLEX, TAMPER RESISTANT TYPE.
RECEPTACLE: GROUND-FAULT-INTERRUPTING, TAMPERRESISTANT TYPE.
IN-SLAB FLOOR BOX: SEE SPECIFICATIONS
RECEPTACLE: DRYER, 30 AMP, 120/250 VOLT
RECEPTACLE: SPECIAL PURPOSE , COORDINATE NEMARATING WITH SPECIFIED EQUIPMENT
ELECTRIC WATER COOLER POWER CONNECTION, GFI OUTLET
HAND DRYER POWER CONNECTION: COORDINATE MOUNTINGHEIGHT W/ ARCHITECTURAL ELEVATIONS SEE HAND DRYERINSTALLATION DETAIL.
RECEPTACLE FOR CLOCK (RECESSED) AND CLOCK;COORDINATE MOUNTING HEIGHT & LOCATION WITHARCHITECTURAL FLOOR PLAN AND ELEVATIONS
RECEPTACLE: QUADRUPLEX, CEILING MOUNTED
SWITCH: SINGLE-POLE
SWITCH: THREE-WAY TYPE
SWITCH: FOUR-WAY TYPE
SWITCH: SUBSCRIPT THAT INDICATES CORRESPONDINGFIXTURES THAT SWITCH CONTROLS
SWITCH: KEY-OPERATED
SWITCH: OVERRIDE
OCCUPANCY SENSOR, CEILING MOUNTED
OCCUPANCY SENSOR, CORNER MOUNTED
OCCUPANCY SENSOR, WALL MOUNTED
VS
VS
VS
VACANCY SENSOR, CEILING MOUNTED
VACANCY SENSOR, CORNER MOUNTED
VACANCY SENSOR, WALL MOUNTED
VSWITCH: LOW VOLTAGE OVERRIDE SWITCH FOR VACANCYSENSOR. WHERE MULTIPLE SUBSCRIPTS ARE INDICATED("ab" FOR EXAMPLE) PROVIDE A PUSHBUTTON FOR EACHCORRESPONDING GROUP OF FIXTURES TO BE CONTROLLED(2 BUTTON SWITCH FOR "ab" FOR EXAMPLE). THEPUSHBUTTONS SHALL BE MOUNTED UNDER A SINGLE GANGFACEPLATE.
D SWITCH: 0-10V DIMMER TYPE COMPATIBLE WITH DIMMINGROOM CONTROLLER.
OSHB
OCCUPANCY SENSOR, CEILING MOUNTED HIGHBAY TYPE
LIGHTING FIXTURE: LINEAR FLUORESCENT
NON-EMERGENCY
EMERGENCY/BATTERY BACKUP
LIGHTING FIXTURE: LINEAR FLUORESCENT
LIGHTING FIXTURE: LINEAR FLUORESCENT
LIGHTING FIXTURE: FLUORESCENT STRIP
LIGHTING FIXTURE: FLUORESCENT, WALL MTD.
DOWNLIGHT/SCONCE FIXTURE
EXIT LIGHT: UNIVERSAL MTD.
DIRECTIONAL FIXTURES: EMERGENCY TYPE
LIGHT TRACK: LENGTH AS SHOWN
DEVICE IDENTIFIER TAGS:
NUMERAL ADJACENT TO DEVICE DENOTES BRANCH CIRCUIT CONNECTION.IDENTIFIER TAGS ADJACENT TO DEVICES INDICATE:
MOUNT ABOVE COUNTERTOP OR BACKSPLASH, 9" ABOVEWORK SURFACE TO CENTER
MOUNT DEVICE AT HEIGHT INDICATED
PROVIDE WEATHER-PROOF COVER
C
XX"
WP
REFER TO ONE-LINE DIAGRAM AND EQUIPMENT CONNECTION SCHEDULE FORLOAD DATA USED AS THE BASIS OF DESIGN AND REQUIRED CONNECTIONS.VERIFY LOAD AND LOCATION WITH EQUIPMENT CUT-SHEETS AND INSTALLER.
FIRE ALARM SIGNAL, HORN AND FLASHING LIGHT, 80" AFF TO THEBOTTOM OF THE LINES. "C" DESIGNATION INDICATES CEILINGMOUNTED.
7.
8.
J
J
MISCELLANEOUS COMPONENTS:
JUNCTION BOX: MTD. ABOVE CEILING
JUNCTION BOX: WALL MTD.
STARTER / DISCONNECT SWITCH. SEE PLAN FOR SIZESEE SPECIFICATIONS FOR TYPE.
SCENE CONTROLLER.
RECEPTACLE: QUADRUPLEX, TAMPER RESISTANT TYPE.
0-10V DIMMING SYSTEM USED IN SPACES WITH ONEDIMMED LIGHTING LOAD. SEE 0-10V DIMMING WIRINGSCHEMATIC. DETAIL ON 6/E0.1.
0-10V DIMMING SYSTEM. SEE CAFETORIUMLIGHTING SCHEMATIC0-10V DIMMING, DETAIL 5/E0.1.
0-10V DIMMING SYSTEM USED IN SPACES WITH ONEDIMMED LIGHTING LOAD. SEE 0-10V DIMMING WIRINGSCHEMATIC. DETAIL 6/E0.1.
D1
D2
D3
CEILING MTD. TELECOMMUNICATION JUNCTION BOX ANDCONDUIT ROUGH-IN TO NEAREST ACCESSIBLE CEILING
T
PROFESSIONAL
NE ER
IGNE
SIGER
ERED
No. 26308
IGROEG
A
A
W
R.L
NERRA
W
WA
RN
ING
: C
ontra
ctor
s, s
ubco
ntra
ctor
s, v
endo
rs a
nd s
uppl
iers
are
adv
ised
that
the
cont
ract
doc
umen
ts c
onsi
st o
fA
rchi
tect
-rep
rodu
ced
prin
ted,
bou
nd a
nd n
umbe
red
spec
ifica
tions
, Arc
hite
ct-r
epro
duce
d pr
inte
d, b
ound
and
num
bere
dbl
ue- o
r bla
ck-li
ne p
rints
, add
enda
, pos
t-bid
add
enda
, and
cha
nge
orde
rs o
nly.
Doc
umen
ts re
prod
uced
by
parti
es o
ther
than
the
Arc
hite
ct, w
heth
er in
har
d co
py o
r in
elec
troni
c fo
rmat
, sha
ll no
t be
cons
ider
ed p
art o
f the
con
tract
doc
umen
ts a
nddo
not
sup
erse
de th
e pr
ovis
ions
of t
he c
ontra
ct d
ocum
ents
. T
he c
ontra
ctor
, sub
cont
ract
ors,
ven
dors
and
sup
plie
rs a
reso
lely
resp
onsi
ble
for v
erifi
catio
n th
at in
form
atio
n ut
ilize
d in
bid
ding
, dev
elop
men
t of s
hop
draw
ings
, and
con
stru
ctio
n of
the
faci
lity
are
iden
tical
to th
e co
ntra
ct d
ocum
ents
.
PROJECT NUMBER
PROJECT DATE
APPROVED BY
CHECKED BY
DRAWN BY
Copyright (c) 2008All Rights Reserved.
ISSUED FOR:
NOT VALID UNLESS SIGNED
JAM
ES
W.
BU
CK
LE
Y &
AS
SO
CIA
TE
S I
NC
. --
AR
CH
ITE
CT
SS
WA
INS
BO
RO
, A
LB
AN
Y,
RO
ME
, S
AV
AN
NA
H A
ND
AT
HE
NS
GE
OR
GIA
SHEET
NUMBER:
3/11
/201
6 11
:22:
35 A
ME
:\$A
CTI
VE
JO
BS
\Hav
en E
lem
enta
ry\2
0151
027E
LEC
-Hav
en-G
jc.rv
t
ELE
CT
RIC
AL L
EG
EN
D A
ND
SC
HE
DU
LE
S
HA
VE
N E
LE
ME
NT
AR
Y
03-11-2016
11415
WAL
WAL
GJC
FINAL
SA
VA
NN
AH
S
AV
AN
NA
H-C
HA
TH
AM
CO
UN
TY
PU
BLIC
SC
HO
OL S
YS
TE
M G
EO
RG
IAS
CH
OO
L C
OD
E: 625-0
131
E0.0
LIGHT FIXTURE SCHEDULE
TYPE DESCRIPTION LAMPS
MANUFACTURER /
SERIES FINISH MOUNTING NOTES
A1 2'X4' LENSED TROFFER WITH 0.125" MIN. #A12LENS AND FLUSH STEEL DOOR WITH MITEREDCORNERS.
LED: 4000 LUMEN,3500K
METALUX "GRLED" SERIES,LITHONIA,LUMAX, CREE
WHITE RECESSED NOTE 1, NOTE 6
A3 1'X4' LENSED TROFFER WITH 0.125" MIN. #A12LENS, AND FLUSH STEEL DOOR WITH MITEREDCORNERS.
LED: 2000 LUMEN,3500K
METALUX "GRLED" SERIES,LITHONIA,LUMAX, CREE
WHITE RECESSED NOTE 1, NOTE 6
A5 KITCHEN SEALED GASKETED 2'X4' LENSEDTROFFER WITH 0.125" MIN. #A12 LENS ANDFLUSH STEEL DOOR. PROVIDE GASKETINGBETWEEN LENS AND DOOR FRAME.
LED: 4000 LUMEN,3500K
METALUX "GRLED" SERIES,LITHONIA,LUMAX, CREE
WHITE RECESSED NOTE 6
B1 2'X4' VOLUMETRIC TROFFER WITH LINEARFACETED REFLECTOR AND REGRESSEDREFRACTIVE SYSTEM.
LED: 4000 LUMEN,3500K
METALUX "CRUZE" SERIES,LITHONIA, LUMAX, CREE
WHITE RECESSED NOTE 1, NOTE 6
B2 2'X4' VOLUMETRIC TROFFER WITH LINEARFACETED REFLECTOR AND REGRESSEDREFRACTIVE SYSTEM.
LED: 5000 LUMEN,3500K
METALUX "CRUZE" SERIES,LITHONIA, LUMAX, CREE
WHITE RECESSED NOTE 1, NOTE 6
C LED HIGHBAY WITH WIDE DISTRIBUTION ANDSEMI-DIFFUSE ACRYLIC SHIELDING ANDWIREGUARD.
LED: 18000LUMEN, 3500K
METALUX "HBLED" SERIESLITHONIA, LUMAX, H.E.WILLIAMS
WHITE CHAIN NOTE 1, NOTE 6
D NARROW (4" MAX) EXTRUDED ALUMINUM SLOTFIXTURE, CONTINUOUS FROSTED ACRYLICLENSE PROVIDE END PLATES AND CORNERCOMPANIONS FOR COMPLETE SEAMLESSINSTALLATION FOR LENGTH INDICATED,INCLUDING CORNERS.
LED: 1500LUMENS, 4000K
FOCAL POINT "SEEM 4",LEADALITE, MARK, NEORAY
WHITE FLANGE -CONTINUOUS
E STRIP FIXTURE, 4 FOOT LENGTH, WITH LENS. LED: 3000 LUMEN,3500K
LITHONIA "ZL" SERIES,METALUX, CREE, LUMAX,H.E. WILLIAMS
WHITE SURFACE NOTE 2
F DOWNLIGH, 6" APERTURE CLEAR SPECULARLOW IRIDECENT REFLECTOR
LED: 2000 LUMEN,3500K
HALO COMMERICIAL,"PD6V132" SERIES,LITHONIA, DAYBRITE,LIGHTOLIER, PRESCOLITE
WHITE TRIMRING
RECESSED 0-10V DIMMING
G 24" RECTANGULAR SURFACE MOUNT FIXTURE,CLEAR OPAL LENS, VANDAL RESISTANT.FIXTURE SHALL BE EQUIPPED DIMMABLEDRIVER.
LED: 2600 LUMEN,25 WATTS, 3500K
LUMINAIRE "SPC 8" SERIES,LITHONIA, METALUX,COLUMBIA, H.E. WILLIAMS
BLACK WALL - SURFACE
H ELEVATOR PIT LIGHT, CLEAR GLASS GLOBEWITH DIE CAST ALUMINUM GUARD.
1-42 WATT TTT,3500K
RIG-A-LITE "CVPW" SERIES,STONECO "VWXL" SERIES,EXCELINE "RLW" SERIES,DAYBRITE "VFSW" SERIES,BASELITE "W2" SERIES
EXPOSEDPARTS
CORROSIONRESISTANT
WALL
OA WALL MOUNTED, WEDGE SHAPE EXTERIORGRADE FIXTURE.
LED: 2000 LUMEN,3500K
LITHONIA "WST" SERIES,HUBBELL, McGRAW EDISON,BETA, PHILLIPS
BYARCHITECT
WALL - SURFACE PROVIDEFIXTURE WITH90 MINUTEBATTERY.
OB OPEN DOWNLIGHT, 6" APERTURE CLEARSPECULAR LOW IRIDECENT REFLECTOR, WETLOCATION LISTED.
LED: 2000 LUMEN,3500K
LITHONIA "LDN6" SERIES,HALO COMMERICIAL,DAYBRITE, LIGHTOLIER,PRESCOLITE
WHITE TRIMRING
RECESSED
OC BUILDING MOUNTED FLOOD LIGHT WITHMOUNTING BRACKET AND ASSOCIATEDHARDWARE. WIDE SYMETRIC FLOOD.
LED: 14,000LUMEN, 3500K
COOPER "NIGHT FALCON"SERIES, LITHONIA "D"SERIES, BETA, PHILLIPS
BYARCHITECT
WALL/VERTICALSURFACE
OD ROUND, CANOPY CEILING SURFACE MOUNTEDLED LIGHT, MAX 14" DIAMETER, 4" DEEP, OPALLENS.
LED: 2385 LUMEN,3500K
LUMINAIRE LED "ARV13"SERIES, LITHONIA, HUBBELL,McGRAW EDISON, PHILLIPS
BYARCHITECT
SURFACE
T1 TRACK LIGHT. SEE TRACK LIGHT DETAIL SHEETE0.2.
T2 7/8" METAL SNOOT, 12V, TRACK LIGHT HEADWITH STRAIGHT TRACK. DIRECT FEEDTRANSFORMER.
6 WATTDIMMABLE LED
MR16
BRUCK "CLAREO SPOT"SERIES, HALO, ARCHITRAK
MATTCHROME
SURFACE
W1 1'X4' FIXTURE, SURFACE MOUNT, LOW PROFILE,VANDLE RESISTANT. FIXTURE SHALL BEEQUIPPED WITH MOTION SENSOR.
LED: 5900 LUMEN,3500K
LUMINAIRE "TSL" SERIES,LITHONIA, METALUX,COLUMBIA, H.E. WILLIAMS
WHITE WALL - SURFACE
XA WALL MOUNT SINGLE/DOUBLE FACE EXITLIGHT, DIE CAST ALUMINUM, UNIVERSALMOUNTING, GREEN LETTERS - DIRECTION OFARROWS AS INDICATED
LED LITHONIA "LE" SERIES,BEGHELLI "LC1E" SERIES,DUAL LITE "CVD" SERIES,SURE-LIGHT "CX" SERIES
BRUSHEDSTAINLESS
UNIVERSAL 90 MINUTEBATTERY
XB CEILING MOUNTED SINGLE/DOUBLE FACE EXITLIGHT, DIE CAST ALUMINUM, UNIVERSALMOUNTING, GREEN LETTERS - DIRECTION OFARROWS AS INDICATED
LED LITHONIA "LE" SERIES,BEGHELLI "LC1E" SERIES,DUAL LITE "CVD" SERIES,SURE-LIGHT "CX" SERIES
BRUSHEDSTAINLESS
UNIVERSAL 90 MINUTEBATTERY
XEM 2 HEAD, WALL MOUNT EMERGENCY BATTERY WITH FIXTURE LITHONIA "ELM" SERIES,BEGHELLI, HUBBELL,SURE-LIGHT, DUAL-LIGHT
WHITE SURFACE 90 MINUTEBATTERY
LIGHT FIXTURE SCHEDULE NOTES:
1 GENERAL: REFER TO LIGHTING PLANS FOR BALLAST VOLTAGES ANDCONFIGURATION OF FIXTURES. FIXTURES INDICATED TO BE DIMMED SHALL BESUPPLIED WITH DIMMING BALLAST AND ALL ASSOCIATED 0-10 VOLT WIRING.SEE DETAILS ON SHEET E0.1.
2 FIXTURES SHALL BE MOUNTED SUSPENDED OR SURFACE, GIVING RIGHT OFWAY TO HVAC DUCT WORK AND/OR EQUIPMENT.
3 PROVIDE BACKBOX ON ALL FIXTURES OF THIS TYPE SO THAT FIXTURES WITHAND WITHOUT EMERGENCY BALLAST ARE AT THE SAME DEPTH.
4 GENERAL: COORINATE ALL MOUNTING OF FIXTURES (GRID/FLANGE) WITHARCHITECTURAL RCP.
5 FIXTURES SHALL BE SELECTED FROM THE FIXTURE SCHEDULE NOT ONLY BYCATALOG NUMBER BUT WITH CONSIDERATION TO MOUNTING, NUMBER ANDTYPE OF LAMPS, AND REFERENCED NOTES. THE FIRST FIXTURE INDICATEDFOR EACH TYPE WITH CATALOG NUMBER IS THE BASIS OF DESIGN FIXTURE,OTHER LISTED MANUFACTURERS PRODUCING AN EQUAL FIXTURE TO THEBASIS OF DESIGNFIXTURE MAY BE PROVIDED.
6 THIS LIGHT FIXTURE IS TO BE SUPPLIED BY THE OWNER, INSTALLED BY THECONTRACTOR.
.
.
.
W D
DN
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD FD
FDFD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FDFD
FD
FD
FDFD
FDFD
FD
FD
FD
FD
FD
FD
FDFD
FDFD
FD
FD
FD
FD
AC
AC
AC
AC
AC
ACAC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
KP
KP
PS
PS
KP
KP
KP
AC
ACACAC AC
AC
AC
AC
AC
AC
FINISHED CEILING3#12,1/2IN. FLEX
3#12, 1 / 2 IN. C
INTERIOR VIEW
1 IN. C.
1 IN. C.
MAKE ALL CONNECTIONS AND PROVIDE ALL ITEMS REQUIRED FORCOMPLETE OPERATING SYSTEM AS REQUIRED BY MANUFACTURER
ELECTRICDOORSTRIKE
INTERIOR VIEW
ELECTRICDOORSTRIKE
PUSH TOEXITBUTTONS
REQUESTTO EXITDETECTOR
REQUESTTO EXITDETECTOR
DOORS WITH ELECTRIC DOOR STRIKE
POWER SUPPLYAND CONTROLLER
(TYPICAL)
LOCATE AT RECEPTIONDESK COORDINATEEXACT LOCATION WITHARCHITECT
MOTOR RATEDSWITCH
1ST GRADE
1602
OFFICE
1204.1
KINDERGARTEN
1605
1ST GRADE
1601
2ND GRADE
1506
2ND GRADE
1507
1ST GRADE
1503
ART
1303
VEST
1303.1
CLOSET
1104.1
ELEC.
1113
VAULT
1111.1
RESTING
1109.1
T.
1104.3
2ND GRADE
1510
WOMEN
1502.1
MEN
1502.2
ELEC.
1600.6
JAN.
1600.2
KINDERGARTEN
1608
INFO SPEC
1107
VEST.
1104.2PRINCIPAL
1104
BOOK STOR.
1500.3
VEST
1502
TEACHER RESOURCE
1502.3
T.
1109.2
BOOK KEEPER
1105
CLINIC
1109
1ST GRADE
1501
EIP
1504
2ND GRADE
1505
2ND GRADE
1508
T.
1508.2
VEST.
1508.1
MECH
1500.4
T.
1508.3
T.
1504.2
VEST
1504.1
MECH
1500.2
T.
1504.3
MECH
1500.7
T.
1505.3
T.
1505.2
VEST.
1505.1
MECH
1500.5
T.
1501.3
T.
1501.2
VEST
1501.1
KINDERGARTEN
1606
1ST GRADE
1604
KINDERGARTEN
1603
KINDERGARTEN
1607
T.
1602.2
VEST.
1602.1
MECH
1600.8
T.
1602.3
T.
1606.2
VEST.
1606.1
MECH
1600.10
T.
1606.3
MECH
1600.1
T.
1601.3
T.
1601.2
VEST.
1601.1
MECH
1600.3
T.
1607.3
T.
1607.2
VEST.
1607.1
MECH.
1212
SPRINKLER/RISER
1211
ELEC
1213
GENERAL OFFICE
1101
DRY FOOD STORAGE
1205
MECH.
1117
ENTRY
1000
HALLWAY
1103.1
STUDENT RECEPTION
1103
WORKROOM
1111
COUNSELOR
1108
CONFERENCE
1203
LOCKERS
1208
TESTING
1110
SIS
1106
FREEZER
1209
COOLER
1207
SERVING
1202
KITCHEN
1204
ELEC
1400.2
PRE-K
1401
DATA
1400.4
CLO.
1404.1
MEN
1408
HALL
1200.1
CORRIDOR
1300
GIRLS
1306
CORRIDOR
1500CORRIDOR
1600
T.
1600.7
STORAGE
1500.11DATA
1500.1
ASSUMED PRIMARY STAFF ENTRYVERIFY WITH ARCHITECTPRIOR TO ROUGH IN
PROVIDE HINGEDTHERMOPLASTIC SHIELDCOMPATIBLE WITH KEYPADSTI-7511F OR EQUAL
E1.5
3J
MONUMENTAL STAIR
1001.3
MEN
1115.1
WOMEN
1115.2
VEST.
1115
STOR.
1301.1
STORAGE
1303.3
MECH
1300.1T.
1301.2
T.
1303.2
STAIR
2000.3
ENTRY
1001.2
JAN.
1300.6
VEST.
1401.1
T.
1401.2
STOR.
1409
STOR.
1407
PARENT RESOURCES
1302
T.
1208.1
T.
1100.1
JAN
1200.3
MECH
1400.1
T.
1403.2
GYM STOR.
1402.1
T.
1404.2
JAN.
1206.1
CAN WASH
1210
WOMEN
1410
VEST
1406
CORRIDOR
1001
STAGE
1201
CORRIDOR
1400
PRE-K
1403
BOYS
1304MUSIC
1301
CONF.
1102
VISITOR RECEPTION
1100
HALL
1206
OFFICE
1404
STORAGE
1200.4
ELEV.
1001.1
ATHLETICS
1402
STAIR
1500.9
STAIRS
1600.5
CAFETERIA
1200
@20' AFF@20' AFF
CRDPS
CR
DPSDPSDPS
CR CR
DPS
DPS
CR
CR
CR
DPS
DPS
DPS
DPS
CR
DPS
CR
DPS
DPS
DPS
CR
CR
B
B
CR
4
TO NEAREST 120 VOLT, 20 AMPUNSWITCHED RECEPTACLECIRCUIT
MOTOR RATEDSWITCH
3#12, 1 / 2 IN. C
INTERIOR VIEW
1 1
22
3
1/2" C. 1/2" C.
5 5
THIS DRAWING IS INTENDED TO INDICATE CONDUIT INFRASTRUCTUREREQUIREMENT ONLY. COORDINATE EXACT REQUIRED COMPONENTSWITH ARCHITECTURAL DOOR SPECIFICATIONS. PROVIDE ALL CONDUITAND BOXES FOR COMPLETE ACCESS CONTROL INSTALLATION.
3#12, 1/2"C.(FLEXIBLECONDUIT)
NOTES:1
2
4
(ACCESS CONTROL CONNECTIONS)
DOOR POSITION SWITCH.
CURRENT TRANSFER HINGE
POWER SUPPLY.
CARD READER.
DELAYED EGRESS SYSTEM - NORMALLY CLOSED FIRE ALARMRELAY REQUIRED, PLUGNPLAY. NORMALLY CLOSED FIRE ALARMRELAY REQUIRED FOR THE DELAYED EGRESS APPLICATION.
3
5
TO MDF/IDF
PROVIDE 12 CONDUCTOR20 GAUGE WIRE WITH THEFOLLOWING COLORS: BLACK,RED, WHITE, GREEN, ORANGE,BLUE, BROWN, YELLOW, PINK,GRAY, TAN AND VIOLET.
T
PROFESSIONAL
NE ER
IGNE
SIGER
ERED
No. 26308
IGROEG
A
A
W
R.L
NERRA
W
NORTH
WA
RN
ING
: C
ontra
ctor
s, s
ubco
ntra
ctor
s, v
endo
rs a
nd s
uppl
iers
are
adv
ised
that
the
cont
ract
doc
umen
ts c
onsi
st o
fA
rchi
tect
-rep
rodu
ced
prin
ted,
bou
nd a
nd n
umbe
red
spec
ifica
tions
, Arc
hite
ct-r
epro
duce
d pr
inte
d, b
ound
and
num
bere
dbl
ue- o
r bla
ck-li
ne p
rints
, add
enda
, pos
t-bid
add
enda
, and
cha
nge
orde
rs o
nly.
Doc
umen
ts re
prod
uced
by
parti
es o
ther
than
the
Arc
hite
ct, w
heth
er in
har
d co
py o
r in
elec
troni
c fo
rmat
, sha
ll no
t be
cons
ider
ed p
art o
f the
con
tract
doc
umen
ts a
nddo
not
sup
erse
de th
e pr
ovis
ions
of t
he c
ontra
ct d
ocum
ents
. T
he c
ontra
ctor
, sub
cont
ract
ors,
ven
dors
and
sup
plie
rs a
reso
lely
resp
onsi
ble
for v
erifi
catio
n th
at in
form
atio
n ut
ilize
d in
bid
ding
, dev
elop
men
t of s
hop
draw
ings
, and
con
stru
ctio
n of
the
faci
lity
are
iden
tical
to th
e co
ntra
ct d
ocum
ents
.
PROJECT NUMBER
PROJECT DATE
APPROVED BY
CHECKED BY
DRAWN BY
Copyright (c) 2008All Rights Reserved.
ISSUED FOR:
NOT VALID UNLESS SIGNED
JAM
ES
W.
BU
CK
LE
Y &
AS
SO
CIA
TE
S I
NC
. --
AR
CH
ITE
CT
SS
WA
INS
BO
RO
, A
LB
AN
Y,
RO
ME
, S
AV
AN
NA
H A
ND
AT
HE
NS
GE
OR
GIA
SHEET
NUMBER:
KEY PLAN - LEVEL 1 3/11
/201
6 11
:25:
42 A
ME
:\$A
CTI
VE
JO
BS
\Hav
en E
lem
enta
ry\2
0151
027E
LEC
-Hav
en-G
jc.rv
t
SE
CU
RIT
Y S
YS
TE
MS
PLA
N -
LE
VE
L 1
HA
VE
N E
LE
ME
NT
AR
Y
03-11-2016
11415
WAL
WAL
GJC
FINAL
SA
VA
NN
AH
S
AV
AN
NA
H-C
HA
TH
AM
CO
UN
TY
PU
BLIC
SC
HO
OL S
YS
TE
M G
EO
RG
IAS
CH
OO
L C
OD
E: 625-0
131
T3.0
SCALE: 1/16" = 1'-0"T3.0
1 SECURITY SYSTEMS - LEVEL 1
SCALE:NOT TO SCALET3.0
2 ACCESS CONTROL DOOR DETAIL
SCALE: 1/8" = 1'-0"T3.0
3 DOOR LOCK CONNECTIONS
GENERAL: WHERE DOOR ISLOCATED IN SPACE WITHCEILING ABOVE 10'-0" OR INSPACE WITH NON-ACCESSIBLE CEILING:POWER SUPPLY SHALL BELOCATED ON WALL ABOVENEAREST 10'-0" (ORLOWER) ACCESSIBLECEILING WHERE INDICATEDOR WITHIN 75' OF DOORBEING SERVED. LOCATIONSOF ALL POWER SUPPLIESSHALL BE NOTED ON AS-BUILT DRAWINGS.
CR
DPS DPS
.
FD FD
FD
FDFD
FD FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD FD
FD FD
FD
FD
FD
AC
DA
CS
INTRUSION ALARM
CONTROL PANEL
CLASSROOM
2502
3RD GRADE
2505
EIP
2501
5TH GRADE
2412
4TH GRADE
2406
5TH GRADE
2407
4TH GRADE
2403
WOMEN
2404.1
VEST.
2404
MEN
2404.2
TEACHER RESOURCE
2404.33RD GRADE
2508
CLOSET
2402.2
CONFERENCE
2402
ELEC.
2402.1
MECH
2500.2
4TH GRADE
2408
5TH GRADE
2410
5TH GRADE
2405
BOOK STOR.
2400.1
4TH GRADE
2401
T.
2410.2
VEST
2410.1
MECH
2400.4
T.
2410.3
T.
2406.2
VEST
2406.1
MECH
2400.2
T.
2406.3
MECH
2400.5
T.
2405.3
T.
2405.2
VEST.
2405.1
MECH
2400.3
T.
2401.3
T.
2401.2
VEST
2401.1
3RD GRADE
2504
GIFTED
2503
3RD GRADE
2507
T.
2502.2
VEST
2502.1
MECH
2500.4
T.
2502.3
MECH
2500.1
T.
2501.3
T.
2501.2
VEST
2501.1
MECH
2500.3
T.
2505.3
T.
2505.2
VEST
2505.1
3RD GRADE
2506
T.
2506.2
VEST
2506.1
T.
2506.3
MECH
2500.6
STAIR
2000.3
COMPUTER LAB
2112
HALLWAY
2000.1
TV BROADCAST
2116
WORKROOM
2104
PROF. INST.
RESOURCES
2105
ATHLETICS MEZZANINE
2220
DATA - MDF
2200.8
JAN.
2200.4
VEST.
2204
MECH
2200.5
JAN. OFF.
2200.10
CORRIDOR
2400 CORRIDOR
2500
CORRIDOR
2300
LEARNING
2103
ELEC.
2114
SCIENCE LAB
2208
AP
2212
SPED
2210
T.
2204.2
T.
2204.1
BEHAVIORAL
SPECIALIST
2205
MATH LAB
2203
WRITING LAB
2201
STORAGE
2407.1
STORAGE
2507.1
DATA
2300.1
MECH
2200.3
VEST.
2201.1
T.
2201.2
T.
2201.3
EQUIP.
2000.2
VEST.
2205.1
T.
2205.3
T.
2205.2
MECH
2204.3
LAB STOR.
2208.1
CORRIDOR
2000
CORRIDOR
2200
CR
OFFICE
2102
CLOSET
2102.1
EQ. STOR.
2106WOMEN
2108
MEN
2110
STORYTELLING
2101MEDIA CENTER
2100
ELEC.
2200.6
T
PROFESSIONAL
NE ER
IGNE
SIGER
ERED
No. 26308
IGROEG
A
A
W
R.L
NERRA
W
NORTH
WA
RN
ING
: C
ontra
ctor
s, s
ubco
ntra
ctor
s, v
endo
rs a
nd s
uppl
iers
are
adv
ised
that
the
cont
ract
doc
umen
ts c
onsi
st o
fA
rchi
tect
-rep
rodu
ced
prin
ted,
bou
nd a
nd n
umbe
red
spec
ifica
tions
, Arc
hite
ct-r
epro
duce
d pr
inte
d, b
ound
and
num
bere
dbl
ue- o
r bla
ck-li
ne p
rints
, add
enda
, pos
t-bid
add
enda
, and
cha
nge
orde
rs o
nly.
Doc
umen
ts re
prod
uced
by
parti
es o
ther
than
the
Arc
hite
ct, w
heth
er in
har
d co
py o
r in
elec
troni
c fo
rmat
, sha
ll no
t be
cons
ider
ed p
art o
f the
con
tract
doc
umen
ts a
nddo
not
sup
erse
de th
e pr
ovis
ions
of t
he c
ontra
ct d
ocum
ents
. T
he c
ontra
ctor
, sub
cont
ract
ors,
ven
dors
and
sup
plie
rs a
reso
lely
resp
onsi
ble
for v
erifi
catio
n th
at in
form
atio
n ut
ilize
d in
bid
ding
, dev
elop
men
t of s
hop
draw
ings
, and
con
stru
ctio
n of
the
faci
lity
are
iden
tical
to th
e co
ntra
ct d
ocum
ents
.
PROJECT NUMBER
PROJECT DATE
APPROVED BY
CHECKED BY
DRAWN BY
Copyright (c) 2008All Rights Reserved.
ISSUED FOR:
NOT VALID UNLESS SIGNED
JAM
ES
W.
BU
CK
LE
Y &
AS
SO
CIA
TE
S I
NC
. --
AR
CH
ITE
CT
SS
WA
INS
BO
RO
, A
LB
AN
Y,
RO
ME
, S
AV
AN
NA
H A
ND
AT
HE
NS
GE
OR
GIA
SHEET
NUMBER:
KEY PLAN - LEVEL 2 3/11
/201
6 11
:25:
52 A
ME
:\$A
CTI
VE
JO
BS
\Hav
en E
lem
enta
ry\2
0151
027E
LEC
-Hav
en-G
jc.rv
t
SE
CU
RIT
Y S
YS
TE
MS
PLA
N -
LE
VE
L 2
HA
VE
N E
LE
ME
NT
AR
Y
03-11-2016
11415
WAL
WAL
GJC
FINAL
SA
VA
NN
AH
S
AV
AN
NA
H-C
HA
TH
AM
CO
UN
TY
PU
BLIC
SC
HO
OL S
YS
TE
M G
EO
RG
IA
SC
HO
OL C
OD
E: 625-0
131
T3.1
SCALE: 1/16" = 1'-0"T3.1
1 SECURITY SYSTEMS - LEVEL 2